Datasheet Romod I/O Modules SL

Similar documents
BQ & BQ370-01N MODBUS ANALOG INPUT DEVICE USER MANUAL

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

LLR-MOD Modbus Light Level and Occupancy Sensor

Kinco PLC Training. Kinco Automation

AC500-eCo: your PLC from ABB Unique scalable concept, optimal costs... Change for more!

BECKHOFF DNP3 Slave Driver User Manual

MOD-RI Room Interface Modules with Modbus

USER MANUAL Z-8NTC 8 CHANNELS NTC TEMPERATURE SENSOR CONVERTER WITH USB / RS485 PORT AND MODBUS RTU PROTOCOL

Ilija Zivadinovic, Martin Wichary, Juergen Schilder, Thorsten Reibel, Stefan Grosse

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

How to set-up and read MOBBUS

UNIVERSAL CURRENT CONVERTER

FNL Modbus TCP Interface

SMARTbox IO Agent User Guide. Cloud Fieldbus PSSYSTEC GMBH HEINBERGSTR NEUSÄSS

Application guide ACS355 and AC500-eCo.

This command can be used for reading the current value of one or several input channels, according to the table below.

Warranty. Warning. Copyright. Contact Us

Softstarters. Type PSTX Fieldbus communication, Anybus Modbus TCP. 1SFC132087M0201 March SFC132087M0201 1

Softstarters. Type PSTX Fieldbus communication, Fieldbus Plug Modbus RTU

SCC Inc. LMV5 Series. Installation Instructions. Document No. LV February 12, 2018

AC500-eCo: your PLC from ABB Unique scalable concept, optimal costs... Change for more!

MU110-6U. Analog output module 6 channel. User guide

IPEmotion_PlugIn_BECKHOFF_V01_05_00

TR600 with RS485 Appendix 1

Modbus Server - M-Bus (EN ) Gateway for the integration of M-BUS meters with Modbus RTU and TCP based control systems.

ICP DAS DeviceNet Total solutions

Getting Started with your D3000M Series Module

ABB Modbus RTU Driver for JMobile

APPLICATION NOTES. Advanced Graphical Interface - AGI Internal PLC (CODESYS V3) SHENDONG

Instrumentation PPS Series Videographic Data Recorders. PPS Series Videographic Data Recorders. Now with Touch Screen Technology!

Beckhoff PlugIn. August V

DCON Utility Pro User s Manual Version 1.1, May 2015

Manual BrainCube Connect with Modbus Master

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

User Manual APAX Software Manual

RXTH DUAL ROOM SENSOR / SWITCH

IP67 IP20. Controllers Open Flexible Compact SPEEDWAY. Programmable. Fieldbus Couplers. Programmable. Fieldbus Controllers

ScadaFlex I/O Toolbox

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

LoRaWAN Wzzard Utility Quick Guide. v /11/1

Multifunction controller GHM-ONE MSR9696H. Multifunction controller. Features. ... professional Instruments M ADE IN GERMANY

Using the WAGO AS-i Module with the SMLC. 9/13/2007 Using the WAGO AS-i Module with the SMLC 1

USER S MANUAL. Gateway DLMS-MODBUS for ITRON/ACTARIS SL7000 with RS232 P/N: GW-DLMS-232-SL7. Edition 2.0

4511 MODBUS RTU. Configuration Manual. Universal transmitter. No. 4114MCM100(1402)

TER-MOD Active Room Temperature Sensors (Controllers) with Modbus

Features and Benefits. Certifications

Connect the UMC100.3 to an Allen-Bradley PLC over EtherNet/IP using the EIU32.0

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

iologik R1200 Series User s Manual

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

SC168MBM 16x8 Characters MODBUS MASTER LCD

PROGRAMMING INSTRUCTIONS

KERN YKI-02 Version /2016 GB

MDC 700 Series User Manual

Internal PLC (CODESYS) User Manual

Installation and Operation Manual. INTEGRA BTU Meter System

Softstarters. Type PSTX Fieldbus communication, Fieldbus Plug Modbus RTU. 1SFC132092M0201 June SFC132092M0201 1

RHR-MOD Combined Room Temperature and Humidity Sensors (Controllers) with Modbus

Your Global Automation Partner. Startup. Getting Started Guide

Modbus Protocol For FTS/FTM 3x&8x

IL ETH BK DI8 DO4 2TX-PAC: IP ASSIGNMENT & WATCHDOG

4511 MODBUS RTU. Configuration Manual. Universal transmitter. No. 4114MCM101(1445) For 4511 devices from ser. no:

THM501 PT100 MODBUS TEMPERATURE TRANSMITTER

iopro Mirrored IO System

Analyze IT AO2000 Modbus and AO-MDDE. Technical Information 30/ EN Rev. 1

iologik R1200 Series User s Manual

I/O Module. Modbus Manual DMB Series.

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

PLC PL User Manual

Copyright: December 2017 Nidec Issue: E

Pen Drive USB Datalogger!

iologik R1200 Series User s Manual

INTELLIGENT I/O MODULE

WRTU Client User Manual. Date: 29 May, 2014 Document Revision: 1.05

CDR Room CO 2 and Temperature Sensor with Modbus

DNP3 Communications Protocol

ezeio Controller and the 2400-A16 input expansion.

Features and Benefits. Certifications

19.Configure HMI as a MODBUS Server

115S Serial I/O Module User Manual

USER MANUAL. Modbus IHP24-A IHP24-AF IHP24-B IHP24-BF IHP24-F IHP24-I 1/26

display, 4 buttons, Modbus -RTU gateway for connection of Modbus -RTU resolution 0,1 C and resistance up to 6553,5

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

DL-10. User Manual. RS-485 Remote Temperature and Humidity. English Ver. 1.0, Jul. 2017

4511 MODBUS RTU. Configuration Manual. Universal transmitter. No. 4116MCM101(1445) For 4511 devices from ser. no:

WHERE THE FUTURE MEETS THE PRESENT. Datascan. solo Network Based Data Acquisition System

Product name: CPU Firmware Release Information Product type: AC500 PLC

KERN YKI-02 Version /2014 GB

Gateway MODBUS-to-Opentherm MB-OTG Technical manual. Revision 1 SETECNA. Rel. Date 1 14/09/2016. Page: 1 di 10. Rev /09/2016

How to Configure DeviceNet with Anybus Configuration Manager (ACM) for DeviceNet APPLICATION NOTE DRAFT

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

ioselect Z-NET Z-SG Bridge Input Isolating I/O Module

A NEW DATA LOGGER Stand alone. Secure. Fast.

Modbus Communication Tool. User manual

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V.

Revision. Decentralized Drive and Application Control MOVIPRO ADC with PROFINET interface * _1017*

Connection Procedure of WAGO CANopen Bus Coupler and Pro-face AGP-3****-CA1M/LT. Instruction Manual. Version1.1 (

4511 MODBUS RTU. Configuration Manual. Universal trip amplifier. No. 4131MCM100(1402)

Modbus User Manual APPLIED MOTION PRODUCTS, INC. Modbus is a registered trademark of Schneider Electric, licensed to the Modbus Organization, Inc.

SmartAir Master. The intelligent compressed air management system Developed by Compair to save your customers money

Transcription:

Datasheet Romod I/O Modules SL This library allows you to use Romod I/O devices from the manufacturer Romutec (www.romutec.de) via RS485 COM-Port on supported CODESYS PLC runtimes. The devices can be easily added to the device tree. The configuration of module specific parameters is done under the device parameters tab, without any programming requirements. All input/output variables can be mapped in the I/O-Mapping section. Without purchasing a license (just download) Romod I/O Modules SL runs for 30 minutes without functional limitations and disconnects automatically (demo). Product Description This library allows you to use the Romod I/O modules 16DI, 8DO, 8DO-R, 4DO-R, 8AI and 8AO with supported CODESYS PLC runtimes. It requires a RS485 COM-Port interface and also a Modbus license (mostly included). The devices can be added to the device tree and also be extended with various romod modules. Variables can be mapped to the program under the I/O-Mapping Tab. All output modules are local override/indication devices, the state can be monitored and changed. If the device is local overrided/indicated, then it will be shown under the device tree. There is also a parameter settings window for each module. Different settings as slave-address, Bus-Timeout, send command or cycle request time can be configured under this section. Many specific I/O extended settings are also available for example: Negation, two-point-function, limiter, damped function etc. The analog input module allows you to select sensors as PT1000/100, Ni 1000, NTC 10k, etc. The Romod-Master device is required for configuring the physical hardware COM-Port. Common serial settings can be configured there. The Hardware modules can be decentral installed (for example in electrical distribution boards). Supported bus cable length for the devices is up to 3937 feet (based on the environmental conditions). Each device address is configurable with dip switches. Serial communication settings as baudrate don t need to be configured, because the devices are supporting Autobauding. This feature is decreasing the fault-rate and also the installation time out of the field. Please note: The modules don t support real-time requirements. Range of Functions General Functions Outputs are head on optimized Cycle request time settable for each input module SafeState: Analog and digital state on bus error (Timeout configurable) Module commands can be sent by bus control (for example factory reset). Request of romod module ID and module firmware Optimized Bus-Watchdog in case of slave interruption 16DI Module Each digital input can be negated under the parameter window Input detection also on delayed bus request Pfänder GmbH Bachstr. 15 74585 Rot am See Germany

CODESYS Inspiring Automation Solutions 2/6 Datasheet Romod I/O Modules SL 8DO and 8 DO-R Module Each digital output can be negated under the parameter window Shows dip switch position: (A)uto (O)ff (O)n 4DO-R Module Each digital output can be negated under the parameter window Configurable press time for hardware button Switching delay between the outputs can be setted Shows dip switch position: (A)uto (O)ff (O)n Reset automatic mode from bus control Manual mode can be disabled 8AI Module Input configuration selectable based on sensor/function and deposited curve: - 0..10 Volt - Widerstand 0..5 kohm - Widerstand 0..10 kohm - PT100/PT1000 - Ni1000 - Ni1000 Landis+Gyr - KTY 81-110 - KTY 81-210 - NTC 20k - NTC 10k Configurable delta value (request only on change between the delta value) Integrated two-point-function Offsetvalue (sensor value correction) Integreated limiter with min and max area. In case of exceeding/falling below the analog value can be get the value as configured, for example: Input, minimum, maxium, replaced value or last value. Also the error flag will be setted to true. Integrated filter with built-in time constant In the I/O section the raw value and the processed value is shown. 4AO Module Configurable Change-Area Safestate for output value in percentage Shows dip switch position with poti value

CODESYS Inspiring Automation Solutions 3/6 Datasheet Romod I/O Modules SL Screenshots Hardware I/O Modules Modules

CODESYS Inspiring Automation Solutions 4/6 Datasheet Romod I/O Modules SL Parameters e.g. AI AI input configuration two-point-function Offset Limiter Damped function I/O Mapping

CODESYS Inspiring Automation Solutions 5/6 Datasheet Romod I/O Modules SL Romod state mode

CODESYS Inspiring Automation Solutions 6/6 Datasheet Romod I/O Modules SL General Information Supplier Support Product Pfänder GmbH Bachstr. 15 74585 Rot am See Germany support@pfaender.de Romod I/O Modules SL Order Number 2312000001 Sales Scope of Delivery CODESYS Store store.codesys.com Romod I/O Modules SL Library Device Descriptions Documentation included in library manager Hardware documentation Romod_Doku_DE.pdf System Requirements and Restrictions Programming System Target System Supported Platforms / Devices CODESYS Development System V3.5.10.0 CODESYS Control V3.5.10.0 Tested devices: CODESYS Control Win V3, Raspberry Pi, Notice: Use the project Device Reader to find out the supported features of your device. Device Reader is available for free in the CODESYS Store. Additional Requirements Restrictions RS485 COM-Port (also possible with USB Com-Port adapter), Modbus RTU License The modules don t support real-time requirements. Maximum number of 30 romod slaves for each Romod-Master device. Licensing License activation optional on CODESYS Runtime Key or CODESYS Soft Key. Demomode for 30 minutes. License per runtime device necessary. Required Accessory Romod I/O modules from the the manufacturer Romutec (www.romutec.de)