DeltaV SIS Conditioning Components

Similar documents
DeltaV SIS TMConditioning Components

DeltaV Bulk Power Supplies

DeltaV Bulk Power Supplies

DeltaV M-series I/O Subsystem Horizontal Carriers

DeltaV VerticalPlus I/O Subsystem Carriers

S-series Mass Connection Solutions

M-series Intrinsically Safe I/O

S-series Horizontal Carriers

S-series Foundation Fieldbus I/O

Introduction. Delivers four ports to provide increased input/ output per card. Takes advantage of all smart device capabilities

S-series Sequence of Events Card

DeltaV SIS TM. Logic Solver. DeltaV SIS Logic Solver. Introduction. DeltaV SIS Product Data Sheet. World s first smart SIS Logic Solver

S-Series DeltaV Controller Interface for PROVOX I/O

M-series Profibus DP Series 2 Plus Interface Card

DeltaV Electronic Marshalling for Migrations

S-series DeviceNet Interface Card

DeltaV SQ Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy-to-use. Field proven architecture

M-series Foundation Fieldbus I/O

DeltaV MQ Controller. Introduction. Benefits. Increases productivity. Easy to use. Has the flexibility to meet your needs. Increases productivity

M-series I/O Subsystem Horizontal Carriers

DeltaV SX Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy to use. Field proven architecture

M-series MQ Controller

DeltaV MX Controller. Introduction. Benefits. Right-sized controllers. Easy to use. Has the flexibility to meet your needs

S-series H1 I/O Card with Integrated Power

M-series Traditional I/O

M-series MX Controller

S-series Horizontal Carriers

M-series DeltaV Controller Interface for PROVOX I/O

M-series Profibus DP Series 2 Plus Interface Card

DeltaV PK Controller. Benefits. Introduction. Powerful Standalone. Easily Integrated. Fast process control applications

M-series DC to DC Power Supply

DeltaV SX Controller. DeltaV SX Controller. Introduction. DeltaV Product Data Sheet. Scalable controllers. Quick Assembly.

S-series Sequence of Events Card

S-series Electronic Marshalling for Migrations

DeltaV SD Plus Controller

S-series DeviceNet Interface Card

DeltaV Ethernet I/O Card

DeltaV M-series Traditional I/O

DeltaV M-series Traditional I/O

S-series Profibus DP Interface Card

Ethernet I/O Card. Ethernet I/O Card. Introduction. DeltaV Product Data Sheet. Easy to use. Powerful integration solution. Modular, flexible packaging

DeltaV S-series Traditional I/O

M-series DeltaV Controller Interface for RS3 I/O

S-series Electronic Marshalling

M-series Serial Interface Series 2

DeltaV M-series Traditional I/O

S-series Ethernet I/O Card

M-series Virtual I/O Module 2

DeltaV Electronic Marshalling

DeltaV Wireless I/O Card

S-series Serial Interface

DeltaV Control Network Hardware

M-series MQ Controller

Introduction. DeltaV Product Data Sheet February 2016 Page 1. M-series MX Controller. Right-sized controllers. Easy to use

CSI 6300 SIS Overview

S-series Electronic Marshalling

S-series Serial Interface

S-series Virtual I/O Module 2

DeltaV Safety Instrumented System (SIS) with Electronic Marshalling

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

CTO CSLS CHARM Cabinets

Model Number Structure

S-series Virtual I/O Module 2

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Valve and Case Expansion Monitor Specifications

CompactBlock Guard I/O EtherNet/IP Safety Modules

DeltaV Controller Firewall

M-series Virtual I/O Module 2

S-series Electronic Marshalling

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

SITOP 3-phase 24 V DC, 20 to 40 A

RSTI-EP Slice I/O. Digital Output Module

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

DeltaV Virtual IO Module Network Gateway

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

DeltaV SIS with Electronic Marshalling - Virtual Simulation

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Model Number Structure

S-series IS Electronic Marshalling

DeltaV IS Electronic Marshalling

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704, EP GFK-2960B November 2017

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

3500/33 16-Channel Relay Module Bently Nevada* Asset Condition Monitoring

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

Wireless Field Data Backhaul

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

MSR178DP. Description. Features. Specifications

Transcription:

DeltaV SIS Process Safety System DeltaV SIS Conditioning Components The DeltaV SIS conditioning components allow you to use the DeltaV SIS system with a variety of different field signal requirements. Enables diagnostics of field wiring all the way to a discrete-input end device Provides diagnostics of field wiring all the way to a discrete-output end device with high inductance Allows for higher current and voltage ratings for discrete outputs Delivers higher voltage ratings for discrete inputs Enables non-incendive discrete outputs Introduction In most cases, DeltaV SIS will connect to either 4-20 ma analog signal devices or discrete I/O devices rated at up to 500 ma per channel. However, there will be some output signals that require higher currents and in some applications non-incendive outputs are required. For applications that simply need high current, the DeltaV solution offers the SIS Relay module. For applications where the current to the final device needs to be limited for non-incendive ratings, there is the current limiter module. Using the RC compensator module ensures that the monitoring of field wiring is performed correctly when using inductive loads. Using the SLS End of Line module ensures that monitoring of field wiring is performed correctly when using discrete switches.

Benefits Enables diagnostics of field wiring all the way to a discreteinput end device: Many safety systems monitor the field wiring from their I/O modules. If the I/O channel is connected to a contact, then the monitoring requires a series and parallel resistor at the contact in order to function. The SLS End of Line Resistance Module allows DeltaV SIS automatic testing of field wiring to work with field contacts. Provides diagnostics of field wiring all the way to a discrete-output end device with high inductance: Many safety systems monitor the field wiring from their I/O modules. However, if the I/O channel is connected to an inductive load, such as a relay or solenoid, then the monitoring may give a false indication when the load is de-energized due to inductive kickback. The R-C Compensator Module allows DeltaV SIS automatic testing of field wiring to work with inductive loads. Enables non-incendive discrete outputs: Many safety systems applications are deployed with non-incendive I/O. The SIS Current Limiter Module allows the DO to be energy-limited to meet the requirements of a non-incendive installation. Product Description SIS Relay Module The SIS Relay module can be used with DeltaV SIS to switch up to 2.5A at 250V AC for safety applications. It opens contacts for field power when de-energized. The SIS Relay module contains three relays from different manufacturers. A relay coil is energized for all three relays in normal operation. If a demand occurs, the SLS removes the power from the coil for all three relays at the same time. Each relay can be proof-tested in the field. Allows for higher voltage ratings for discrete inputs: For applications that require higher voltage inputs than the DeltaV SIS system natively supports, an external relay is often required. The Voltage Monitor meets the requirements for suitability for SIL 3 applications with testability in situ. Delivers higher current and voltage ratings for discrete outputs: For applications that require switching higher current than the DeltaV SIS system natively supports or for switching higher voltages, a safety relay is often required. However, the safety relay needs to be proof tested at some interval as determined by the SIL requirement. The SIS Relay meets the requirements for suitability for SIL 3 applications with testability in situ. SIS Relay Module. SIS Relay Module Input Power Rating 70.0 ma @24V DC ± 20% Relay current rating Mounting Functional Safety Certification 2.5 A @ 250V AC 2.5 A @ 30V DC Horizontal or vertical Din rail Height 100.0 mm (4 in.) Width 22.5 mm (0.9 in.) Depth 114.0 mm (4.5 in.) IEC 61508 SIL3 Class I Div. 2 GP A,B,C,D HAZ. LOC. TEMP. Rating T4 Ta=70 ~ C ATEX II 3 G EEx nc IIC NEMKO 02ATEX431U See Page 8 for SIS Conditioning Components Common www.emerson.com/deltavsis 2

SIS Voltage Monitor The Voltage Monitor can be used with the DeltaV SIS system to drive a Logic Solver s Discrete Input channel or a DeltaV Series 2 DI Dry Contact channel based on the output of the Safety Relay module. The Voltage Monitor has the following connections: Four-pin connections for connecting input to DC or AC power sources Four-pin connections for connecting outputs to two SLS DI channels Four-pin connections for connecting outputs to two DI, Dry Contact SIS Voltage Monitor Input Power Rating 6 ma @ 24V DC ± 20% 15 ma @ 120/230V AC Mounting Horizontal or vertical DIN rail Functional Safety Certification Height 100.0 mm (4 in.) Width 22.5 mm (0.9 in.) Depth 114.0 mm (4.5 in.) IEC 61508 SIL3 Class I Div. 2 GP A,B,C,D HAZ. LOC. TEMP. Rating T4 Ta=70 ~ C ATEX II 3 G EEx na IIC NEMKO 02ATEX431U See Page 8 for SIS Conditioning Components Common SIS Voltage Monitor. www.emerson.com/deltavsis 3

SIS Current Limiter The SIS Current Limiter limits the current from the SLS Discrete Output channels to levels below the ignition curves for Class 1 Div 2 and Zone 2 installations. Field wiring from the Current Limiter output to the field can be removed and reconnected under power. The SLS Current Limiter has the following connections: Four-pin connections for input from the SLS DO channels Four-pin connections for output to energy-limited loads SIS Current Limiter Module Input Power Rating (from SLS DO Channels) Output Power Output Current Range Output Current Limit Threshold Mounting 17 to 29V DC; 22V DC nominal 28.8V DC (max) 0-100 ma (max) 100 ma (min); 120 ma (max) Horizontal DIN rail Height 100.0 mm (4 in.) Width 22.5 mm (0.9 in.) Depth 114.0 mm (4.5 in.) Class I Div. 2 GP A,B,C,D HAZ. LOC. TEMP. Rating T4 Ta=70 ~ C ATEX II 3 G EEx nl IIC T4 NEMKO 02ATEX431U See Page 8 for SIS Conditioning Components Common SIS Current Limiter. www.emerson.com/deltavsis 4

RC Compensator Module When using line monitoring on outputs that are driving inductive loads greater than or equal to 0.8 Henry in simplex or 0.3 Henry in redundant, an RC compensator may be required. The RC compensator module is sized at 3.3 kω and 0.47 μf for simplex and 2.7 kω and 0.22 μf for redundant. This module can be used for simplex and redundant applications. RC Compensator H 2.31 cm (0.91 in.) W 3.48 cm (1.37 in.) Depth 1.7 cm (.67 in.) Class I Div. 2 GP A,B,C,D HAZ. LOC. TEMP. Rating T4 Ta=70 ~ C ATEX II 3 G EEx na II C NEMKO 02ATEX431U See Page 8 for SIS Conditioning Components Common RC Compensator Module. www.emerson.com/deltavsis 5

End of Line Resistance Module The Discrete Input channel on the SLS1508 and some LS DI CHARMs have line fault detection for detecting open or short circuits in field wiring. The End of Line Resistance Module provides a 12 KΩ resistor in parallel (allows the open circuit detection) and a 2.4 KΩ resistor in series (allows short circuit detection) to provide the appropriate resistance for line fault detection. This module connects to the Discrete Input channel on the SLS1508 or to LS DI CHARM types that support fault detection and to a field contact. End of Line Resistance Module H 2.31 cm (0.91 in.) W 3.48 cm (1.37 in.) Depth 1.7 cm (.67 in.) Class I Div. 2 GP A, B, C, D HAZ. LOC. TEMP. Rating T4 Ta=70 ~ C ATEX II 3 G EEx na II C NEMKO 02ATEX431U See Page 8 for SIS Conditioning Components Common End of Line Resistance Module. www.emerson.com/deltavsis 6

System Compatibility SIS Conditioning Components Common Common Environmental For SIS Conditioning Components Category Storage Temperature Operating Temperature* Relative Humidity -40 to 85 C (-40 to 185 F) -40 to 70 C (-40 to 158 F) -40 to 60 C (-40 to 140 F) for vertical mounted SIS Relay Module and Voltage Monitor 5 to 95%, non-condensing Airborne Contaminants Protection Rating IP 20 ISA-S71.04-1985 Airborne Contaminants Class G3 Conformal Coating Certifications Shock Vibration European EMC Directive per EN61326-1, Criterion A NAMUR NE21 EMC Requirements Low Voltage Directive IEC 61010-1 CSA C22.2 No. 1010.1 10 g ½-sine wave for 11 ms 1 mm peak-to-peak from 5 to 16 Hz; 0.5 g from 16 to 150 Hz *Operating any electronics at the higher end of its temperature range for long periods of time will shorten its expected lifetime, see Effects of Heat and Airflow Inside an Enclosure White Paper for more information. Ordering Information Description SIS Relay Single Channel SIS Voltage Monitor Dual Channel SIS Current Limiter Quad Channel RC Compensator Module, Box Of 10 SIS End Of Line Resistance Module, Box Of 10 Model Number VS6907 VS6906 VS6908 VS6905 VS6904 Prerequisites DeltaV v8.3 software or later. www.emerson.com/deltavsis 7

Emerson North America, Latin America: +1 800 833 8314 or +1 512 832 3774 Asia Pacific: +65 6777 8211 Europe, Middle East: +41 41 768 6111 www.emerson.com/deltavsis 2017, Emerson. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. The DeltaV logo is a mark of one of the Emerson family of companies. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.