AS-Interface. In Thirty Days

Similar documents
Universal Control Platform for Pneumatic Valves Facilitates System-wide Compatibility

Siemens Digitalized Production Cell Boosts Auto Parts Manufacturing by 20% siemens.com/global/en/home/products/automation

Flash Decisions: Which Solution is Right for You?

Maximizing Efficiency. In Data Centers

Solve Compliance, Integration & Process Challenges Using Rich Data From Your Instrumentation

Challenges of Multivendor Systems in Implementation of IIoT-ready PLCs. ISA/Honeywell Webinar 10 November 2016

PARALLELING GENERATOR SET SYSTEMS AND DESIGN. Don Dentino Senior Strategy Consultant for Product Definition Caterpillar Inc.

Flash Decisions: Which Solution is Right for You?

Integrating IO-Link Devices into CIP Networks

Power+ Family Products. P+ Family Products: Seth Davis- Global Marketing Manager

Products for DeviceNet

Profibus and Modbus: a comparison

At Miele, Beckhoff bus terminals represent the corner points of remote automation

Industrial Automation

Your Global Automation Partner. Elevating Ethernet Intelligence: Implementing Ethernet Technology in Industrial Applications. White Paper - W1004

Website Designs Australia

S. Zellinsky / J. Piriou Application Marketing

Perfect Balance of Public and Private Cloud

RED HAT ENTERPRISE LINUX. STANDARDIZE & SAVE.

Printed in U.S.A., Copyright Penton Media, Inc. All rights reserved. Machine Design (ISSN ) is published semimonthly by Penton Media,

How Emerson s I/O on Demand Is Changing the Automation Infrastructure

How to choose an Industrial Automation Controller: White Paper, Title Page WHITE PAPER. How to choose an Industrial Automation Controller

Boost your productivity. by upgrading your Modicon Compact 984

Your Global Automation Partner. The Full Range for Industrial Ethernet

Products for DeviceNet

Control strategies for web handling

INDUSTRIAL POWER GROUP DEPT.OF ELECTRICAL ENGINEERING NIT CALICUT

ORACLE DEPLOYMENT DECISION GUIDE: COMPARING YOUR DEPLOYMENT OPTIONS

MULTIPLE PROTOCOLS FOR VALVE ACTUATOR CONNECTIVITY

Connecting Motion Control in the Factory Implementing Communication Protocols

ELEVATING ETHERNET INTELLIGENCE:

(Controller Area Network)

SUCCESS STORY HÄAGEN-DAZS JAPAN HÄAGEN-DAZS JAPAN DRAMATICALLY IMPROVES USER EXPERIENCE AND PRODUCTIVITY WITH NVIDIA GRID

Understanding Office 365: Is A Cloud Based Solution Right For Your Business?

Making the case for SD-WAN

SMART INSTRUMENTS, FIELDBUS, ETHERNET AND INDUSTRIAL WIRELESS.

Choosing the Right. Ethernet Solution. How to Make the Best Choice for Your Business

Fieldbus technology An Overview

Having communication issues? Model 6 intelligent Motor Control Centers communicate on all platforms. Make the most of your energy SM

Background Brief. The need to foster the IXPs ecosystem in the Arab region

ADVANCED SCADA CONTROL SYSTEMS

What is SCADA? What is Telemetry? What is Data Acquisition? Differences between SCADA and DCS? Components of SCADA. Field Instrumentation

Curtin University School of Design. Internet Usability Design 391. Chapter 1 Introduction to Usability Design. By Joel Day

Motion and Logic in the Drive Helps Drive Down Automation Costs

FIeldbus. Sense it! Connect it! Bus it! Solve it! /03

Side-by-Side Comparison: Agilent N5700 System DC Source and Xantrex XFR DC Power Supply

Real-Time Ethernet in Mobile Automation

The Allen-Bradley PowerFlex Family of AC Drives

GET CLOUD EMPOWERED. SEE HOW THE CLOUD CAN TRANSFORM YOUR BUSINESS.

and Emerging Instrument Technologies

DeviceNet of Things Use Cases, Value Proposition and Status of Specification. John Caspers Rockwell Automation. February 22, 2017

iopro Mirrored IO System

Subject: Top-Paying IT Certificates for 2015 (And Our New Courses)

Networks. In this lesson we will discuss: What do Networks do?

JUMO mtron T. Measuring, Control, and Automation System. Features. Brief description. Systembus LAN. Data Sheet Page 1/12. Com1.

Find Hidden Budget Dollars with PDF Software. How making a software switch can improve your bottom line

Future has begun - IO-Link Application stories

SmartStruxure Lite Solution Get control. Get efficient. Get value. Integrated small- to medium-sized building management

A quick guide to... Split-Testing

Dual Module VCT. 5. Lexan Enclosure is Water & Corrosion Proof Contaminants will not affect the module as long as terminal strip is not immersed.

PRODUCT INFORMATION. DeviceNet Triple Play Digital Communications Board. SA Actuator with AUMA Matic Motor Controls

in Berlin (Germany) Sponsored by Motorola Semiconductor NEC Electronics (Europe) Siemens Semiconductors Organized by

BUSINESS 478. Section D400 CASE SYNOPSIS FOR: SAMSUNG

HPE Nimble Storage Partner Sales Guide

Welding Automation OEM Grows Business With More Flexible Machine Design. Mavrix Welding Automation. New Berlin, Wisconsin

Exploring Cloud. Is moving your phone system to the cloud right for your business?

^2 Accessory 55E DeviceNet Option

Disaster Recovery Is A Business Strategy

Bringing OpenStack to the Enterprise. An enterprise-class solution ensures you get the required performance, reliability, and security

Why Converged Infrastructure?

PRODUCT INFORMATION. AUMA Actuators, Inc. Pittsburgh PA USA. Triple Play Digital Communications Board DeviceNet / Modbus CDN455

The Economic Benefits of a Cooperative Control Wireless LAN Architecture

4 Hidden Budget-Killing PDF Software Pitfalls. And how to avoid them

iscsi Unified Network Storage Increases the Cost-effectiveness of the Distributed Information Value Chain

plc operation Topics: The computer structure of a PLC The sanity check, input, output and logic scans Status and memory types 686 CPU

HART COMMUNICATION. A Digital Upgrade For Existing Plants

Industrial Ethernet Made Simple

5 Things Small Businesses Need to Know About Disaster Recovery

The Future of CAN / CANopen and the Industrial Ethernet Challenge by Wilfried Voss, President esd electronics, Inc USA

Why Converged Infrastructure?

WHOLESALE HOSTED CENTREX

expertise beyond controls Vanguard Series 5

Industrial Fieldbus Technologies: Understanding the basics and simplifying your decision

PROFIBUS and Integrated Safety architectures in Ex areas

Secret CPA Superhero

White Paper Integrating Wireless Communications and Controls Into Lighting Fixtures

Need high availability in performance in your PLC? Modicon Premium Hot Standby PLC by Schneider Electric. Make the most of your energy SM

Designing Next Generation Test Systems An In-Depth Developers Guide

Sales Presentation Case 2018 Dell EMC

Ruchiman Priatna (Control Technology) Freelance The easy-to-use distributed control system

PROGRAMMABLE LOGIC CONTROLLER

Industrial Ethernet Comparison for Motion Control Applications

DeviceNet - CIP on CAN Technology

The data quality trends report

DeviceMaster UP Modbus Controller to Controller Communication

Key questions to ask before commissioning any web designer to build your website.

Dell EMC Hyper-Converged Infrastructure

4-20 ma Transmitter vs. Machine Saver s VTBNet

Remote monitoring in open water

Up and Running Software The Development Process

Transcription:

AS-Interface In Thirty Days 1

AS-Interface In Thirty Days Introduction Replacing simple sensors and actuators with AS-Interface (AS-i) sensors and actuators is one of the hottest trends in automation today, and for good reason. AS-i, already a worldwide de facto standard for simple I/O networking, is quickly becoming a US standard too. Its potential to cost-effectively replace the rat s nest of wires that permeates most industrial sites is tremendously appealing across many industries. Of the available low-level sensor/actuator replacement networks, AS-i offers the highest performance at the least cost. Due to its roots as a Siemens network, AS-i already enjoys the enthusiastic support of the Industrial Automation community in Europe. Now many automation vendors in the US are becoming attracted to its high speed, power on bus, simplicity of operation, and insulation displacement wiring system. With Control Engineers increasingly more comfortable with a stratified networking system, AS-i is the perfect solution for the lowest level in the network architecture, those simple, low -level sensors and actuators that consume the majority of installation, startup, and ongoing troubleshooting expenses. Quite frankly, with the growth of AS-i networking, for many automation vendors it is now a mistake to not support AS-i. Important Questions Once you decide that your products must support AS-i, the big question becomes how can I get it done and get it done quickly? Do you have excess Engineering resources to commit to the project? Can your existing opportunities and customers for AS-i be put off until next year? Is your engineering staff intimately familiar with the technology? Are they experienced in the somewhat complex minefield of device-id selection? Do you have the PLCs, tools and physical resources to thoroughly test an AS-i solution? If you re having difficulty with any of these issues, then this paper is written for you. It details the technical information you need to know and gives you practical steps for adding AS-i to your existing product in the next 30 Days. Overview AS-interface is an intelligent cabling system designed to replace the discrete wires that link a Programmable Controller with sensors and actuators. AS-i provides a single cable system that is fast, easy-to-wire, and easy-to-operate. Built for the simplest types of devices, AS-i is a Master-Slave system where a single AS-i Master can exchange I/O data with up to 62 AS-i Slave devices. Each Slave can transfer up to four inputs and four outputs on a bus cycle. AS-i is a standard hardware and software bus system that brings the reality of truly open systems to the lowest level of the automation business. Your customers are not just asking for connectivity at all levels of the control system, they absolutely expect and require it. Over 11,000,000 AS-i devices are now deployed worldwide. If you aren t already in this game, your competitors may already be a step ahead of you. For specific information about AS-i, see Table 1. 2 2

Table 1 A Technical Summary of AS-i Maximum Number of Nodes 31 in traditional systems, 62 in V2.1 Number of I/O Points Maximum Cable Length Power Medium Wiring Technology Topology Typical Data Rate Error Detection Configuration Addressing Master-Slave Operation Hot Swap of Slave Devices Multiple Master Operation Troubleshooting PLC Programming Discrete Device Support Analog Device Support 248 I/O points (4In, 4Out per node) in V1.0, 434 (8In, 3Out per node) in V2.1 100m without repeaters, 300m with repeaters 24VDC Unshielded 2 wire cable for both power and data Insulation displacement for speed and ease of installation. Tree Structure All 31 nodes can be interrogated in 5msec. 10 msec for 62 node systems. The AS-i master automatically detects invalid slave transmissions and schedules repeats Slaves are automatically configured with a Slave Address by the Master or a Programming Tool. Masters can interrogate the network to identify connected slaves or receive an external list of slave addresses. Each slave gets a specific address set by the AS-i Master or Programming Tool A Master polls each slave sequentially and awaits a response. Supported Not Supported AS-i Masters automatically monitor system voltage levels and slave operation and report this data to the controller. No special knowledge of AS-i bus or device structure is required to program a PLC to use AS-i bus data. AS-i data is simply remote IO data to the PLC. Supported Limited support in V1 and V2.1 using multiple bus cycles (12-bit analog across five bus cycles) 3 3

Advantages The first attraction to AS-i is its low cost. Cost savings are typically 15% to 40% of other bus systems using traditional cabling methods. Plus, the ongoing additional benefits of a bus system ensure enhanced operation and improved maintenance which reduce life cycle costs while improving product quality because of better performance and less downtime. Second, the speed of AS-i attracts a lot of attention. Connected slaves are polled in turn by the AS-i Master. A V1 network (31 devices) provides a maximum response time of 5mS per I/O point. In practice, most systems have fewer than 31 devices and the cycle times can be significantly shorter. The newer, extended AS-i bus with 62 devices provides a maximum response time of 10msec per I/O point, still much faster than the data acquisition and logic scans of most Programmable Controller systems. Third, AS-i is inherently deterministic and repeatable. Transmissions between the master and slave are predefined and cyclic. The time to set an output is calculable with great accuracy. And there are other attractions to AS-i including a simplicity not found in any other industrial network, device power right on the network cable, and no need for Master or Slave Programming. There are no system parameters to set and devices are configured simply by identifying their device ID to the AS-i Master. AS-i is a very important technology, not only because it addresses the lowest level of a control system architecture, but also because it is backed by Siemens, the worldwide leader in Industrial Control. This gives it an automatic advantage in the marketplace. AS-i will be successful for many of the same reasons that systems like DeviceNet have been successful; strong momentum and the backing of a vendor with a huge installed base. Competition AS-i cannot be compared to Sensor bus networks like DeviceNet, Profibus, and Interbus-s. All these bus systems are more costly, support more generic communications, provide advanced diagnostic functionality, and are highly configurable. These systems support very sophisticated, intelligent devices with tremendous data capabilities. Devices like drive systems, HMIs, barcode readers and the like couldn t find a home on AS-Interface. How to implement AS-i quickly & effectively Once you ve made a decision to add AS-i connectivity, you have a number of ways to proceed. The choices vary in timeto-market, supportability, resource requirements and price. 1. Use an off-the-shelf Serial Gateway An off-the-shelf serial gateway is the least economical approach with the fastest time-to-market. To implement a serial gateway, your product must support a common serial communication protocol like Modbus, DF/1, or even dumb ASCII. Data from your product will transfer to the gateway at serial baud rates (1200-19200). Other than time-to-market (typically a week or two), there are few real advantages to this approach and many negatives. Gateways require an additional footprint, they can be costly, they are generally overkill for a simple device, and the gateway vendor appears as the AS-i device owner. This option is only attractive if you expect low volume requests for AS-i connectivity. 2. Use an AS-i PCB If your device uses standard signals, an AS-i PCB that accepts your signals and places them on the bus is an alternative solution for quick time-to-market projects. Built to your exact footprint and I/O requirements, a custom solution is relatively fast and requires almost none of your resources. Custom solutions offer you the latest in capabilities while giving you absolute control of your development, network presentation, and implementation. This approach is great for medium volume applications (i.e. a few hundred units per year). Real Time Automation supplies PCBs of this kind. The advantages to this approach are relative low cost and tight system operation. Disadvantages include the cost of one-time tooling and NRE. 4 4

3. Do-It-Yourself The most costly, lengthy, and risky approach is to form an internal effort to build it yourself. While this is admittedly what you d expect to hear from a company whose business is selling custom networking hardware and software, the facts still speak for themselves. Like most bus implementations there are nuances to the AS-i specification that are not readily discernable. For example, the specification provides some very ambiguous language describing how to pick the device ID. A Few More Considerations Another important consideration is testing and certification. Do you have the tools and resources to test, troubleshoot and, certify your AS-i implementation? A key to selecting a vendor to get AS-i in 30 days is to make sure that your vendor has all the right tools and can assist you with troubleshooting, locating adequate test tools, and the certifying your device. You must consider documentation. There are standard documentation formats for network devices. Your customers will expect your products to follow these standards. To get to market in 30 days, documentation issues need to be addressed early in the process. You must consider certification. Many customers simply will not purchase products unless they have passed a certification test. It s not uncommon for products to be sent back to the lab a second or third time before they finally pass. If RTA does an AS-I implementation for your product, you are guaranteed first time success. You must consider Maintenance and Support. There are keys to success for any new technology. There will be inevitable corrections and revisions to the initial specifications. How you deal with these changes matters a great deal. Real Time Automation Guarantees Your Success. Few people in the automation have the guts to guarantee anything, but Real Time Automation guarantees that your product will be ready for AS-i in 30 days or less, or you only pay half. What to do next Call or Email John Rinaldi, OEM Sales Manager, at (414) 453-5100 / jsr@rtaautomation.com and ask for an AS-i Project Application. John will be happy to discuss your specific requirements and deadlines, and discuss any aspect of AS-i that you may still be unclear about. The RTA team looks forward to serving you as you tackle one of the most important new technologies in today s automation business. Don t let a shaky economy, protocol confusion, or fear of the unknown keep you from participating in new project opportunities! AS-i can be an important part of your product success story. 5 5