FUTURLED3 TRAFFIC SIGNAL MODULES THE STANDARD FOR HIGHEST OPTICAL PERFORMANCE

Similar documents
The new Photonic F1 LED light source has set a further milestone in the development of modern cold light sources.

LED light engines ready2apply

LED light engines ready2apply. Module SLA DC G2 50mm SNC Modules SLA ESSENCE

LED unit. Selection diagram LED COLOUR white LED red LED green LED blue LED orange LED INDICATION MODE CONNECTIONS MOUNTING TYPE

FLIPLED TUBE. The intelligent LED tube

Vaya Tube, White & Mono (On-Off)

PD 60 PIXEL DOT User s Manual & Installation Guide

Electrical connection

Enhancing Business Performance

XB7EV07BP round pilot light Ø 22 - clear - integral LED - 24 V - screw clamp terminals

Energetic diffuse reflection light scanner. Dimensioned drawing

LED light engines ready2apply. Module SLA DC G2 50mm SNC Modules SLA ESSENCE

EXTENDED DATASHEET: BUBO LED TUBE

Indoor/ outdoor projector MINI-PROJECTOR-02 3LED VISIBLE Ufo-02

S 180 OPTICAL AND AUDIBLE MODULAR DEVICES. This is our idea that lead us to create and engineering this modular lamp. MODULAR CONFIGURATION

LED Driver Compact fixed output

PHASED OUT. LED light engines ready2apply. Engine SLA ready2apply phase-cut SNC Engine SLA ESSENCE

IRMA MATRIX Release 2

Descriptions. The Hyper Red source color devices are made with Low power consumption.

Luminous patterns - panels

PHOENIX CONTACT Features

1. Housing, Mounting and Accessories Electrical Installation Optical features Control...8. H: Tender text...

Designed to make your job easier MSA 2.0 and MSA 2.1 Electrofusion Units

Liner Shield AC XB CW

LED LINEAR ALLROUND GEN. 3

>dawn FC OUTDOOR USE

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

AC modules LED linear / area. Engine LLE AC G1 24mm SNC Module LLE ESSENCE

Adaptable Full-Color LED DMX Luminaire

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

F-LED 255 (WIDE BEAM)

Lighting Controls and Connectivity DALI sensors. MSensor G3 SFI 30 PIR 10DPI WH Multi-sensor

SPEC NO: DSAE9407 REV NO: V.6B DATE: JAN/19/2015 PAGE: 1 OF 6 APPROVED: WYNEC CHECKED:

Process displays For current and voltage

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

AIAS. Technical description

LED Driver Compact fixed output

HAZARDOUS AREA PTZ IP NETWORK CAMERA

Eco IndustryLine Single-module functional lighting

Leica KL200 LED / Leica L2

Design meets Technology

A&E Specifications Rev AV AV10255AMIR-H 10-Megapixel/1080p Dual Mode H.264 Day/Night IP MegaDome

XUSL4E14F046N XUSL type 4 - Finger protection - Std sensing range - Hp = 460 mm, R=14mm

HandRail 930XX LED Safety Luminaires for Escape Route Lighting

15-06 Morlot Avenue, Fair Lawn, NJ USA Tel: (201) Fax: (201) LED SERIES DMX TUBE LED RGB DMX TUBE

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

SafeSite LED Stainless Steel Linear - ATEX / IECEx for Indoor and Outdoor Industrial Applications

Monochrome Tube CW. 995mm x 17mm x 20mm 39.2 x 0.67 x Outdoor (IP66), suitable for coastal environments

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Liner Shield AC XB RGB

SPEC NO: DSAM4545 REV NO: V.2B DATE: MAR/29/2013 PAGE: 1 OF 6 APPROVED: WYNEC CHECKED:

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

SPEC NO: DSAJ9211 REV NO: V.6B DATE: SEP/06/2014 PAGE: 1 OF 7 APPROVED: WYNEC CHECKED:

Dimensions. Model Number. Indicators/operating means. Features. Electrical connection. Product information OQT150-R100-2EP-IO-V31-L

ProfiLux LED 350/01. Illumination. LED Technology (white) Innovation made by OASE NEW

Remote I/O Unit with Connectors for Light Curtain CC-Link Safety System. panasonic.net/id/pidsx/global

SmartBalance recessed combining performance with smart design

SPEC NO: DSAD1051 REV NO: V.14B DATE: APR/07/2015 PAGE: 1 OF 5 APPROVED: WYNEC CHECKED:

Description. Kingbright

SPEC NO: DSAF1085 REV NO: V.8A DATE: FEB/04/2015 PAGE: 1 OF 5 APPROVED: WYNEC CHECKED:

SPEC NO: DSAO1259 REV NO: V.1A DATE: JAN/24/2015 PAGE: 1 OF 5 APPROVED: WYNEC CHECKED:

STEP-PS/1AC/24DC/1.75

Retro-reflective photoelectric sensors with polarisation filter. Dimensioned drawing. Electrical connection

Description. Kingbright

XUSL4E14F121N XUSL type 4 - Finger protection - Std sensing range - Hp = 1210mm, R=14mm

9i Full Matrix Display Radar Driver Feedback Sign

AC modules LED compact

QL Induction Lighting Systems

Shield AC Extend XB RGB

CF /BF SERIES CAMERAS

XUSL4E2BB051L XUSL type 4 - Body protection - Long sensing range 510 mm

3.0mmx1.0 mm RIGHT ANGLE SMD CHIP LED LAMP. Features. Description. Package Dimensions. Part Number: APA3010SRCPRV-GX.

The most sustainable lighting solution. QL 85W Induction Lighting System

SUBJECT TO CHANGE WITHOUT NOTICE

Description. Kingbright

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

SCHOTT EasyLED Series

DVI Dual Link Extender via MPO Fiber Self-EDID Programming Up to 500m in one Multimode Fiber

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Cleanroom LED CR250B uniform, reliable, value-for-money solution

Kuhnke Technical Data. Contact Details

Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer

Absolute Encoders Multiturn

Tunable White LED linear / area. Module QLE G2 PREMIUM QLE PREMIUM

ABL1REM Main. Rated power in W. Power supply output current V. <= 100 Aat 230 V AC. 2.5 Aat 240 V

ABL8MEM12020 regulated SMPS - 1 or 2-phase V AC - 12 V - 2 A

DigiPot Software Configuration Menu

AL SERIES. AL Series - 75 Watts. Key Features & Benefits: Technical Specifications: Additional Options: ESL. Reference Guide WATTS GENERATION COLOR

ABL8REM24030 regulated SMPS - 1 or 2-phase V AC - 24 V - 3 A

QUINT-PS AC/24DC/10

Product specifications

The device is distinguished by low power consumption, a long service life and robust construction.

QUINT-PS/ 1AC/24DC/ 5

LED Driver Compact fixed output

RoHS. High shaft load capacity. Shock / vibration resistant

Transcription:

FUTURLED3 TRAFFIC SIGNAL MODULES THE STANDARD FOR HIGHEST OPTICAL PERFORMANCE With more than 2,500,000 FUTURLED3 units sold, SWARCO FUTURIT impressively underscores its outstanding position and know-how in LED signalling technology. Over 10 years of experience in the development and manufacture of LED-based signals allow us to offer highly reliable, state-of-the-art products. The central light source combined with the dual lens system enables a brilliant and very uniform signal display. KEY BENEFITS no LED dots visible, very uniform signal glow central light source highest anti-phantom performance (class 5) lowest power consumption and brilliant light output all products traceable by serial number custom-made masks allow any symbol display life cycle > 5 years optimum heat balance reduces degradation to a minimum automatic light compensation in case of diode failure proven technology diing function available VDE-compliant FUTURLED3 modules available also available with clear lens modules compliant to local norms available (UK, South Africa) optical monitoring available compatible with standard-conforming signal head housings SWARCO FUTURIT 2012 01.02.2012 1 / 9

TECHNICAL DETAILS 230V Diameter 100 210 300 Luminous intensity Not applicable red > 200 cd amber > 200 cd green > 200 cd red > 400 cd amber > 400 cd green > 400 cd Optical performance Not applicable B2/1, W B3/1, N Colour red 613.5-631 nm, amber 585-597 nm, green 498.5-508 nm, white 5000 7000 K Uniformity of Luminance LED type Phantom light class Not applicable High Flux Not applicable better than 1 : 2.5 Class 5 Power Factor > 0,9 Operating Voltage bright mode/died mode Frequency 196 265 V / n.a. 45 55 Hz 196 265 V / 160 V 180 V (light output is reduced to app. 50 % of normal level if the input voltage is decreased) SWARCO FUTURIT 2012 01.02.2012 2 / 9

Power consumption: typically bright mode / died mode red 5 W / n.a. amber 5 W / n.a. green 5 W / n.a. white 5 W / n.a. red 8 W / 4 W amber 8 W / 4 W green 9 W / 4.5 W white 9 W / 4.5 W EMC acc. EN 50293 Cable Ambient temperature range 2 x 0.75 ²; 1 m Class A, B, C Protection Class Safety Class II acc. to EN 60598 Tightness IP 65 acc. to EN 60598 Impact resistance Class IR3; acc. to EN 60598-1 Material of lens / housing UV-stabilized polycarbonate Weight < 0.25 kg < 1.0 kg < 1.5 kg Dimensions (incl. front lens) Ø 108 x 72 Ø 210 x 117 Ø 300 x 149 SWARCO FUTURIT 2012 01.02.2012 3 / 9

TECHNICAL DETAILS 12V / 24V Diameter Ø 210 Ø 300 Ø 210 Ø 300 Luminous intensity red > 200 cd amber > 200 cd green > 200 cd red > 400 cd amber > 400 cd green > 400 cd red > 200 cd amber > 200 cd green > 200 cd red > 400 cd amber > 400 cd green > 400 cd Optical performance Colour Uniformity of Luminance LED type B2/1, W B3/1, N B2/1, W B3/1, N red 613.5-631 nm amber 585-597 nm green 498.5-508 nm white 5000 7000 K better than 1 : 2.5 High Flux Phantom light class Class 4 Power Factor > 0,9 Operating Voltage bright mode/died mode 12V DC (+10%; - 15%) 12V DC (+10%; - 15%) 24V AC/DC (+10%; - 15%) 24V AC/DC (+10%; - 15%) Frequency - - 24V AC: 50 Hz (+/- 5%) 24V AC: 50 Hz (+/- 5%) SWARCO FUTURIT 2012 01.02.2012 4 / 9

Power consumption: typically bright mode / died red 4 W amber 4 W green 4 W white 4 W red 4 W amber 4 W green 4 W white 4 W red 12 W amber 12 W green 12 W white 12 W red 12 W amber 12 W green 12 W white 12 W EMC acc. EN 50293 Cable Ambient temperature range acc. to EN1236 2 x 0.75 ²; 1 m Class A, B, C Protection Class Safety Class II acc. to EN 60598 Tightness IP 65 acc. to EN 60598 Impact resistance Class IR3; acc. to EN 60598-1 Material of lens / housing UV-stabilized polycarbonate Weight < 1.0 kg < 1.5 kg < 1.0 kg < 1.5 kg Dimensions (incl. front lens) Ø 210 x 117 Ø 300 x 149 Ø 210 x 117 Ø 300 x 149 SWARCO FUTURIT 2012 01.02.2012 5 / 9

TECHNICAL DETAILS 40V / 42V Diameter 100 210 300 Luminous intensity Not applicable red > 200 cd amber > 200 cd green > 200 cd red > 400 cd amber > 400 cd green > 400 cd Optical performance Colour Uniformity of Luminance LED type Not applicable B2/1, W B3/1, N red 613.5-631 nm amber 585-597 nm green 498.5-508 nm white 5000 7000 K Not applicable better than 1 : 2.5 High Flux Phantom light class Not applicable Class 5 Power Factor > 0,9 Operating Voltage bright mode 40V AC (+25 %; - 15%) - OCIT 40V AC (+25 %; - 15%) - OCIT 42V AC 36V - 50V AC) - ASTRIN Class II died mode not available 31 V AC (+10%; -15%) - ASTRIN Klasse II Frequency 50 Hz (+/- 10%) SWARCO FUTURIT 2012 01.02.2012 6 / 9

Power consumption: typically bright mode / died mode red, amber, green, white 5 W / n.a. According to OCIT-/ASTRIN Cl. II-specifications EMC acc. EN 50293 Cable Ambient temperature range 2 x 0.75 ²; 1 m Class A, B, C Protection Class Safety Class II acc. to EN 60598 Tightness IP 65 acc. to EN 60598 Impact resistance Class IR3; acc. to EN 60598-1 Material of lens / housing UV-stabilized polycarbonate Weight < 0.25 kg < 1.0 kg < 1.5 kg Dimensions (incl. front lens) Ø 106 x 72 Ø 210 x 117 Ø 300 x 149 SWARCO FUTURIT 2012 01.02.2012 7 / 9

PICTURES SWARCO FUTURIT 2012 01.02.2012 8 / 9

YOUR CONTACT APM PRO sp. z o.o. ul. Barska 70, 43-300 Bielsko-Biała, Polska t. +48 33 815 77 38 f. +48 33 822 81 48 apm@apm.pl www.apm.pl SWARCO SWARCO FUTURIT 2012 01.02.2012 9 / 9