AS-i Safety Output Module, IP20

Similar documents
AS-i Safety Output Module with Diagnostic Slave, 1 EDM input, 3I and 2O

Digital Modules AS-i in IP20, 22,5 mm

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

Analog Modules AS-i, IP67, M12

AS-i Safety Input Modules (M12), IP67

Active Distributors AS-i Safety, Active Distributors AS-i

Encoder signal/ Sensor signal. Number of monitored axes. sine/cosine, SSI, TTL (1) up to 2 independent axes. sine/cosine. up to 2 independent axes

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

AS-i 3.0 PROFINET-Gateways with integrated Safety Monitor

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

AS-i 3.0 Sercos Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Active Distributors ASi Safety, IP67

AS-i Safety Analog Input Module, IP20

AS-i 3.0 motor module

Digital Modules AS-i, IP67, M12

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor

Analog Modules AS-i IP65, M12

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 Motor modules

AS-i 3.0 motor modules

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i Safety Relay Output Module with Diagnostic Slave

AS-i 3.0 EtherCAT Gateways with integrated Safety Monitor

PCB AS-i modules, board based solutions

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i Safety Relay Output Module with Diagnostic Slave

System manual AS-i safety monitor AC041S /00 05/2013

AS-Interface I/O Module

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC /00 07/2017

Original operating instructions Safety relay with relay outputs G1501S / / 2016

XPSMCMDO Digital output pairs expansion modules with screw term

Operating instructions. Switching amplifier DN0210 DN / / 2015

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident-No

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Compact Coded Magnetic Safety Interlock Switch and Control Units

VersaPoint I/O Module

RSTI-EP Slice I/O. Digital Output Module

VersaMax IP I/O Module

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

XPSMCMMX inputs 2 output pairs expansion module with screw term

GS202 Encoder Switch

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident no

E-STOP relays, safety gate monitors

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

Installation Instructions Temperature transmitter TAA /00 06/2011

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches

Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015

Safety control unit B1 / B1. for 2 to 16 machine safety sensors. Use. Types. + PLd according to EN ISO

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Line Coupler, MDRC LK/S 3.1, GH Q R0001

Operating instructions valve control box AS-i

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Solid State Remote Power Controller E /627

AS-i Safety. Two-wire bus system.

General Data. Ambient Conditions - Operating temperature: -25 C C - Storage temperature: -40 C C - Humidity: up to 95%, non-condensing

E-STOP relays, safety gate monitors

Communications & Networking

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

SIMOCODE 3UF Motor Management and Control Devices

Operating instructions. Speed monitor D / / 2014

Operating instructions Diagnostic electronics for vibration sensors VSE002 / VXE002 / VXE003 VYE001 / VYE002 / VYE003 / VYE /01 05/2015

SITOP in the SIMATIC Design

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016

Making Hazardous Operations Safe and Productive

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC

LXM28AU07M3X motion servo drive - Lexium 28 - single and three phase V W

PSR UC/ESAM4/3X1/1X2/B

Can be configured in the PNOZmulti Configurator Semiconductor outputs: or 4 safety outputs in accordance with EN 954-1, Cat. 3

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

ISO SINAMICS G110D FAQ

Pluto AS-i Safety. Simplify construction of systems! Provides a flexible system! Allows easy expansion of the system!

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

Phone: Fax: Web: -

The SMART Non-contact Safety Sensor SRF With an innovative diagnostic system

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

Binary output and supervision 520CSD01 Data sheet

SMARTSCAN INFORMATION

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

CONFIGURABLE SAFETY RELAYS

Non-Contact Safety System CES-AZ

PSR DC/ESP4/2X1/1X2

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

02/11/2015

Transcription:

a AS-i Safety Output Module Safe outputs and standard inputs in one module Protection category IP20 Figure Housing Inputs digital Outputs Safety, SIL3, cat.4 Input voltage (sensor supply) 1 Output voltage (actuator supply) 2 AS-i connection 3 AS-i address 4 Article no. 6x COMBICON 1- circuits, x fast electronic safe outputs out of AUX out of AUX clamps depending on number of circuits BWU236 1 Input voltage (sensor supply): inputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, inputs shall not be connected to earth or to external potential. 2 Output voltage (actuator supply): outputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, outputs shall not be connected to earth or to external potential. 3 AS-i connection: the connection to AS-i as well to AUX (auxiliary 24 V power) is made via yellow resp. black AS-i profile cable with piercing technology or via M12 socket (in IP20 via clamps). 4 AS-i Address: AB Slave (max. 62 AB Slaves/AS-i network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/AS-i network), mixed use allowed (upon request, slaves are available with specific AS- Slave profiles). www.bihl-wiedemann.de We reserve the right to change any data Mannheim, 16.12.16 page 1

Article no. BWU236 Connection Connection COMBICON plug Length of connector cable unlimited 1 AS-i Profile 1 loop resistance 150 Ω configuration slave: S-7.A.5 4I/4O slaves: S-7.A.7 diagnostics slaves: S-7.A.E depending on configuration Addresses Required Master profile M4 Since AS-i specification 3.0 Operating voltage 1 31,6 V Max. current consumption 200 ma AUX Voltage 20 30 V (PELV) Max. current consumption A Inputs Number digital inputs Power supply out of AUX Input level U<5 V (low) U>15 V (high) Outputs Number circuits 1- circuits, configurable Number x fast electronic safe outputs Power supply out of AUX Max. output current 2 A per output, = max. A (see table Derating for output current ) Test pulse if output is switched on: minimum distance between two test pulses: 250 ms, pulse length 1 ms Display LED ASI (green) AS-i power LED FAULT/FLT (red) AS-i error LEDs I1 In (yellow) state of inputs I1 I4 LEDs SO1 SOn (yellow) state of safe outputs SO1 SO LED ALARM PLC reports alarm LED AUX (red) on: 24 V DC AUX on off: no 24 V DC AUX Environment Applied standards EN 62026-2:2013 EN 6150:2010 EN 62061:2005/A1:2013 EN ISO 13 49-1:200/AC:2009 Operating altitude max. 2000 m Ambient temperature 0 C +55 C Storage temperature -25 C +5 C Housing plastic, din-rail mounting Tolerable loading referring to humidity according to EN 61131-2 Protection category EN 60529 IP20 Voltage of insulation 500 V Weight 270 g Dimensions (W / H / D) in mm 22,5 / 99 / 114 page 2 Mannheim, 16.12.16 We reserve the right to change any data www.bihl-wiedemann.de

Derating for output current Installation with mounting distance 3 cm left/right I max. [A] 6 >50 mm >30 mm >30 mm T amb [ C] 0 40 55 Installation without mounting distance I max. [A] >50 mm 6 5 0 35 45 55 Diagnostic slave 1- (depending on number of circuits) setting of in- and outputs AS-i output AS-i input O0 P1=1 P1=0 I0 Diagnostic not used 1: output controlled by safety 0: inhibits output on irrespective of safety (see table ( Diagnostic (device colors") ) O1 not used I1 O2 not used I2 O3 inexistent I3 P2=0 P2=1 1: feedback for user: safety on 0: feedback for user: safety off In 1 Peripheral fault indicates unavailable AUX or overload on the outputs 1 state of the assigned input. T amb [ C] Release conditions Standard I/O slaves Standard I/O slaves Slave 1 Slave 2 P0 = 0 D n-1 =0 P0 = 1 D n-1 =1 P0 = 0 D n-1 =0 P0 = 1 D n-1 =1 Diagnostic slaves Slave 1 4s P1 = 1 P1 = 0 O0 = 0 O0 = 1 off off off off off Slave 5 s P1 = 1 P1 = 0 O0 = 0 O0 = 1 off off off off off www.bihl-wiedemann.de We reserve the right to change any data Mannheim, 16.12.16 page 3

Diagnostic (device colors) Value Color Description State change LED SO1 SO 0 green output on on 1 green flashing 2 yellow restart inhibit auxiliary signal 2 1 Hz 3 yellow flashing 4 red output off off 5 red flashing waiting for "reset of error condition" auxiliary signal 1 Hz 6 gray internal error, such as "fatal error" only via "Power On" on device all LEDs flashing 7 green/yellow output d, but not switched on switching-on by setting of O0 off Programming instructions diagnostic slave (bit setting) P1 P1=1 safety output controlled by safety only P1=0 safety output controlled by safety and O0=1 P2 P2=1 input In 1 at AS-i bit I3 P2=0 feedback for user: on s P0, P3: not used 1 state of the assigned input. 4I/4O slave Programming 4I/4O slaves (bit setting) AS-i output AS-i output Slave 1 Slave 2 Slave 1 Slave 2 O0 SO1 SO5 I0 I1 I5 O1 SO2 SO6 I1 I2 I6 O2 SO3 SO7 I2 I3 I7 O3 SO4 SO I3 I4 I Programming instructions 4I/4O slave (bit setting) P0 P0=1 safety output controlled by safety and output bit = 1 P0=0 safety output controlled by safety only s P1, P2,P3: not used Configuration slave Programming hints AS-i output AS-i input O0, communication CTT2 I0, not used O1 I1 O2, LED ALARM I2, communication CTT2 O3 not used I3 Peripheral fault indicates unavailable AUX. page 4 Mannheim, 16.12.16 We reserve the right to change any data www.bihl-wiedemann.de

BWU236 Clamps Description I1 In digital inputs SO1 SOn safe outputs AS-i+, AS-i- connection to the AS-i bus AUX+ ext.in supply voltage out of external 24 V, positive pole AUX- ext.in supply voltage of external 24 V, negative pole ASI ALARM Diagnostics (device colors) Value Color Description State change LED SOn 0 green output on on 1 green flashing 2 yellow restart inhibit auxiliary signal 2 1 Hz 3 yellow flashing 4 red output off off 5 red flashing waiting for "reset of error condition" or AUX missing auxiliary signal 1 or connect AUX Hz 6 gray internal error, such as "fatal error" only via "Power ON" on device all LEDs flashing 7 green/yellow output d, but not switched on switching-on by setting of O0 off Block diagram F-Logik (F-Logic) Freigabe (Release) Freigabe (Release) Eingänge (Inputs) I 1 In Ausgang (Output) SO1 Ausgang (Output) SOn AS-i + AS-i - AS-i As long as the F-logic has - by means of the safe AS-i output slaves- d, the physical outputs can be switched via the data bits of the 4I/4O slaves via standard control. If the is omitted, the physical outputs will be switched off safely. All physical outputs can be d jointly by a safe AS-i output slave. However, it is also possible to install one safe AS-i output slave for each single physical output. Each intermediate setting is possible, e.g. one safe AS-i output slave for 2 physical outputs. www.bihl-wiedemann.de We reserve the right to change any data Mannheim, 16.12.16 page 5