Web monitoring tool (UTY-AMGX) Copyrights 2010 Fujitsu General Limited, Sales Division, All rights reserved.

Similar documents
setting manual VRF System UTY-ASGX Ver. 1.0 Please read the LICENSE AGREEMENT in the manual first

Trend Micro Core Protection Module 10.6 SP1 System Requirements

Installation Guidelines Ujjwala KYC Offline Application. By:

WEB MONITORING TOOL for VRF System

Professional Edition. Hardware Requirements

intelligent Touch Manager

Perceptive TransForm. Technical Specifications. Version: 8.x Compatible with ImageNow 6.5.x to 6.7.x and Perceptive Content 7.x

AttAcc Systems Installation

IDIS Solution Suite. Streaming Service. Software Manual. Powered by

Autodesk Revit Structure 2012 System Requirements and Recommendations. Minimum: Entry-level configuration. Operating System Microsoft Windows 7 32-bit

WEB MONITORING TOOL for VRF System

EasyMP Monitor Operation Guide Ver.4.31

EasyMP Monitor Operation Guide Ver.4.31

Touch pen Management Tool OPERATION MANUAL

2016 inn In ovatint SYSTEM novatint version 3 REQUIREMENTS System Requirements D ate :

IBM SPSS Text Analytics for Surveys

IDIS Discovery. Operation Manual. Powered by

INIT USER S MANUAL (1)

Installing and Setting Up the Snap-on EPC. Rev.1.10 (10 Oct 2013) PN EN

EMP Monitor Operation Guide V4.30

Installing and Setting Up the Snap-on EPC. Rev.1.6 (12 Apr 2012) PN EN

2 Line Monitoring

EasyMP Monitor Operation Guide Ver.4.52

Dino-Lite Handheld Digital Microscope AM413T. User s Manual

Visual Nexus Version 4.0

USB-VGA DISPLAY ADAPTER USER MANUAL

MINIMUM HARDWARE AND OS SPECIFICATIONS File Stream Document Management Software - System Requirements for V4.2

EasyMP Monitor Operation Guide Ver.4.54

How to register your user account and ECL Comfort 310 controller to the ECL Portal

Programmable Logic Controller

RightNow May 08 Workstation Specifications

System Requirements. SuccessMaker 3

TOUCH DISPLAY DOWNLOADER OPERATION MANUAL

BLUETOOTH 2.0 MINI USB ADAPTER. Quick Start Guide TABEL OF CONTENTS

Technical Specifications and Hardware Requirements

TOSHIBA Label Printer. BCP Setting Tool Operation Manual

LCD MONITOR TOUCH PEN UTILITY OPERATION MANUAL. Version 1.0

SuccessMaker Learning Management System System Requirements v1.0

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

The PanasonicVRF Driver

Microsoft SQL Server 2012

IDIS Solution Suite. Video Wall Service. Software Manual. Powered by


This section explains the operating environment for updating the firmware.

A+ Exam Cram 2. Copyright 2003 by Que Publishing. International Standard Book Number: Warning and Disclaimer

Dyna Doctor Installation Manual

The Monitoring Software of Chigo CMV DC Inverter Instruction Manual

IDIS Discovery. Operation Manual. Powered by

User s Manual. EXTERNAL 4 BAY USB3.0 & esata ENCLOSURE SY-ENC50104

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

INST.NO. INE-919. DI5000 Setting Software

TEMPERATURE DOCUMENTATION with KIRSCH-DATANET

Installation Service. 1.0 Executive Summary. Factory Trained Technician Train Customer Support Staff On Basic Operation Of The Equipment

MaestroLink Basic. AirScout airflow meters into any network switch and allow MaestroLink to scan the network and self-populate the equipment.

Questions and Answers

ACT! by Sage Corporate Edition 2010 System Requirements

Nevco Message Center Installation Manual Retain this manual in your permanent file. 08/27/ Rev. C

1 Act! Premium v17 System Requirements

Intel Platform Administration Technology Quick Start Guide

Owner s Manual RBC-AX32U(W)-E RBC-AX32U(WS)-E AIR CONDITIONER (SPLIT TYPE) Wireless remote controller kit. Model name: English.

Fle F xs le y xs s y C s on C tr on oller

INSTALLATION INSTRUCTION FOR ESAM APPLICATION

Symantec Backup Exec System Recovery

User s Manual. Home CR-H408 4-Bay Portable RAID Tower EXTERNAL 4 BAY SATA RAID USB3.0 & esata ENCLOSURE

GP-N100 Utility Software Manual

User s Manual. Home CR-H458 4-Bay Portable RAID Tower EXTERNAL 4 BAY SATA RAID USB3.0 & esata ENCLOSURE

Digital Viewer II TM Digital Microscope User s Manual

Novo Interactive Tools Installation Guide

Web Server (IIS) Requirements

Pocket Quick Reference Guide On the TOSHIBA

CDR DICOM Quick Start Guide

Government Center PVTC Technical Requirements

Sage ACT! PRO 2011 System Requirements

DFW (D&M Firmware Writer)

Pocket Quick. Reference Guide. On the TOSHIBA RBC-AMS51E. Remote Controller

RightNow August 08 Workstation Specifications

Profox Companies Ltd; Navisworks, Navistools & services

Government Center PVTC Technical Requirements

Unity Loader V2.3 Readme

Homeschool Enrichment. The System Unit: Processing & Memory

Vmware VCP-101V. Infrastructure with ESX Server and VirtualCenter. Download Full Version :

U-DAC8. User Manual 8-CHANNEL HIGH-RESOLUTION USB DAC

The following table lists minimum hardware requirements and recommendations for your SolarWinds Patch Manager system.

Installation Guide and Release Notes

Quick Install Manual

GV-Center V2 INTRODUCTION GV CENTER V2 VS. GV CENTER V2 PRO

ViewTi Scalable Digital Microscope

Central Controller G-50A/GB-50 Web Browser Operation Manual (For Managers)

Remote Backup Software. User Manual

IMC Intelligent Analysis Report v7.1 (E0301P02) Copyright (c) 2015 Hewlett-Packard Development Company, L.P. and its licensors.

Development of Small Capacity UPS, "SANUPS 001 ASC"

Smart HUB - HUB to expand one Master Controller s RS-485 port to 8 RS-485 ports - Use 12VDC power

Blood Glucose Management Software User manual Name: DiaLife Mini

Facility Management Station

About Us. Our Story. To l l F r e e Product Color Codes

Minimum Hardware and OS Specifications

Design Simulator. Ver Model replacement function. Copyright(C) 2017 Fujitsu General Limited. All rights reserved.

Aaronia GPS-Logger Software. Users Guide

EasyMP Monitor Operation Guide Ver.4.52

EX700i Print Server/Integrated Fiery Color Server. Welcome

Transcription:

Web monitoring tool (UTY-AMGX) 1

Product feature Difference of UTY-AMGX and UTY-ASGX Main feature Update version for Web monitoring tool 2

Difference of UTY-AMGX or UTY-ASGX Background Model Web Monitoring Tool UTY-AMGX Service Tool UTY-ASGX Main Role of Tools Check the operating status of the VRF System tool 3

Difference of UTY-AMGX or UTY-ASGX Operating place Web Monitoring Tool UTY-AMGX VRF system building Service Tool UTY-ASGX VRF system building Monitoring site VRF system site VRF system site Remote monitoring Monitored at monitoring site + Monitoring at VRF system site Inspection at VRF system site 4

Difference of UTY-AMGX or UTY-ASGX Main User Dealer / Distributor SE/Service staff Web Monitoring Tool UTY-AMGX FGL / Sales company Engineer / Service staff Service Tool UTY-ASGX Service company Service staff Maintenance section (Local) Manager Building maintenance company SE / Service staff Service company Service staff Service staff 5

Difference of UTY-AMGX or UTY-ASGX Usage depending on process Web Monitoring Tool UTY-AMGX VRF system site Monitoring site Service Tool UTY-ASGX VRF system site Commissioning Delivery Monitoring Trouble Maintenance 6

Difference of UTY-AMGX or UTY-ASGX Function comparison table Item Service tool Web monitoring tool VRF system site Monitoring site Interchangeability of equipment Indication of equipment list Operation control Indication of refrigerant circuit diagram Commissioning tool Monitoring of equipment information Monitoring of sensor data Storage and CSV output of operating history (sensor data) Indication of trend graph Printing of trend graph Monitoring and screen display of abnormalities E-mail automatic transmission of abnormalities Setting for user level 7

Difference of UTY-AMGX or UTY-ASGX Comparison table (New Function) Item Service tool Web monitoring tool VRF system side Monitoring side Network Topology Analysis Remote Setting Clock Setting Software Version Display Time Guard Forced Cancellation of Central Control Function Model Name Writer Data Memory Recording before Abnormality Summary Web monitoring tool Web monitoring tool can analyze the cause of failure by tracking the history of operation remotely when a failure such as error is generated, so that it can respond to the service rapidly. 8

Main feature On-site & Off-site Monitoring & Analysis Error message for E-mail Support 4 VRF network system 9

Main feature : On-site & Off-site -Trouble shooting is performed by monitoring each unit remotely on monitoring site. - Monitoring site computer is not required to install special software, requires only general web browser. - Operation status can be checked and analyzed to detect on monitoring site. 10

Main feature : Monitoring & Analysis - Operation status and various sensor information can be monitored and checked real time in the form of list, refrigerant circuit diagram, and graphs as well. - The monitoring data in a remote side can be optionally downloaded. And, this data can be displayed in off-line mode of the service tool. 11

Main feature : Error message for E-mail -Error notification can be automatically transmitted to several locations using the internet. E-mail E-mail Service staff Internet Error Sales company 12

Main feature : Support 4 VRF network system - PC USB adaptor (max. 4 adaptors per PC) permit control and monitoring of up to 1600 units. Suitable for large-scale buildings or hotels. 13

Update version for UTY-AMGX Additional new 6 functions Update version Correspond to OS 14

Update version for UTY-AMGX Additional new 6 functions - Network Topology Analysis (VRF system site only) Make a topological display of units connected to VRF network system by segments. (Objects for display : indoor units, outdoor units, signal amplifier, controller) Error 15

Update version for UTY-AMGX - Remote setting (VRF system site only) Function setting of indoor units, which is configured by remote controller, can be set up remotely. - Indoor unit address cannot be changed. - Outdoor unit cannot be available. Function No.11 0 1 16

Update version for UTY-AMGX - Clock setting (VRF system site only) The clock of each VRF system device (remote controller, etc) can be set remotely with setting of time and date. 17

Update version for UTY-AMGX - Software version display (VRF system site only) Display software version of indoor units, outdoor units, etc.. Software version E V Software version E V 18

Update version for UTY-AMGX - Time guard Save operational time (each 10 hours) of indoor units and outdoor units in CSV format. <Main object parts> Indoor units : Total time of indoor units` power distribution, Total time of fan operation Outdoor units : Total time of outdoor units` power distribution Total time of inverter compressors` cooling operation Total time of inverter compressors` heating operation Total time of constant rate compressors` operation 19

Update version for UTY-AMGX - Forced cancellation of central control function (VRF system site only) Forced cancellation of central control functions which indoor units keep (prohibiting remote controllers, high and low limits of set temp.). This function should be used as backup when controller units such as system controller are broken. 20

Update version for UTY-AMGX Update version Applicable model New release model Version Ver. 1.0 Ver. 1.1 Correspond to OS Model name Applicable version New release version OS* CPU Microsoft Windows 2000 professional SP4 Windows XP Professional SP2 or later Windows Vista Home Premium, Business Intel Pentium / Celeron, AMD Athlon / Duron 1GHz or higher Microsoft Windows XP Professional SP3 or later Windows Vista Home Premium, Business Windows 7 Professional Memory 1GB or more 1GB or more * 64-bit version of Windows are not supported. Intel Pentium / Celeron, AMD Athlon / Duron 1GHz or higher 21