PowerXL PC Tools Eaton Corporation. All rights reserved.

Similar documents
Power Xpert C445 Motor Management Relay Cheat Sheets

DC1 Series 1 Hour Product Overview Eaton Corporation. All rights reserved.

Power Xpert incontrol One Installer Release Note

Chapter GSoft2 Getting Started

Chapter 5: Communications 5 1 SR55 Communications Overview 5 2

Serial Connection of HC900 Hybrid Controller to 900CS Control Station

LB/FB8X09* / LB/FB8X05*

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual

FI303DTM - Device Type Manager

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

MODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE

This is the procedure to use the Clone module as a serial converter: To enable communication you must set the following parameters in the drive.

Instructions. Modbus RTU Card (WSIQ-COM-MB)

Operating a Power Xpert C445 Global Motor Management Relay with a Rockwell PLC via Ethernet/IP

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng

Hamilton HDM and DTM Quick-Guide

PMEUCM Hardware. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

PowerXL DG1 Redundant Drive Application

MGate MB3000 Modbus Gateway User s Manual

DC1 Series 10 min Product Overview Eaton Corporation. All rights reserved.

Ethernet Modbus X80 Gateway Device Type Manager

How-To. Modbus-TCP communication between CelciuX and NJ. History

DCON Utility Pro User s Manual Version 1.1, May 2015

HDM and DTM Quick-Guide

Copyright: December 2017 Nidec Issue: E

Overall Description. Generated by D.J.Withenshaw Date 05/09/2007 Revision A. (Name) only. Page 1 of 7

Universal Serial/PROFIBUS DP Gateway GT200-DP-RS User Manual V6.1 SST Automation

MGate MB3000 Modbus Gateway User Manual

Micro-Modular Programmable Controller

1. Introduction. 2. Installation INSTALLATION INSTRUCTIONS: MCD USB MODULE

Reno A & E, 4655 Aircenter Circle, Reno, NV (775) Release Date: February 5, 2008 All Reno A&E monitors. All versions of RaeComM.

Ethernet HMi RAC and Gateway Setup Instructions Rev. 09

Smart HUB - HUB to expand one Master Controller s RS-485 port to 8 RS-485 ports - Use 12VDC power

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

E2 Modbus RTU Register Map Revision History Version Comments Author Date 1.02 Previous version PAE 11/06/ Revised to new format PAE 09/03/09

CAS IKS Gateway (Modbus RTU/TCP and HTML) Manual

User Manual A08. User Manual

User Module. DF1 Ethernet APPLICATION NOTE

Installation and Programming Manual

DUCM Hardware. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series

Optional Accessories 6 2

Field Procedure For Installation Of A WEB/SNMP Card For enotify

Please refer to application note AN00129 for further details on HCP2 configuration in ABB motion control products.

Webinar Organizers. Ryan Shea. Bruce McDuffee. Joe Ryan. Webinar Moderator. Applications Specialist. Product Manager. Precision Digital Corporation

Control Techniques Variable-Speed Drive (VSD) Interface to E2 v and Above

FY400DTM - Device Type Manager

1. Introduction. 2. Installation MODBUS INTERFACE

Manual# Installation Manual SDU 410. Safety Shutdown Unit

Power Xpert Meter 2000 Gateway Card Kit

Hello Angles... A First Use Guide to the SOLAR Product Series: RS485 Interface with ModBus RTU Communication Protocol.

AP-ENBD User Manual V0.2

ENMAT Premium Data Logger User Manual

Chapter 1. Introduction. Additional Documentation

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

Cover. MATWorX Installation Guide NWA ISSUE 2.1

FBP FieldBusPlug. Technical Manual. USB to FBP UTF21-FBP UTF21-FBP DTM V

IntesisBox Modbus Server Fidelio IP

C-more Micro-Graphic Panel Accessories

1.4 MConfig PC software can be optionally used to upload/download configuration settings to the VRU Pro using RS-485 communication.

DATRAN XL4 RTU Modbus Interface

ETHERNET/MFC 010 Technical Datasheet

CPU module for zone 2 Series 9442/35

Manual BrainCube Connect with Modbus Master

Optidrive Applications Support Library

Installation and Programming Manual. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

APPENDIX B SERIAL I/O MODULE INSTALLATION / OPERATION WHEN USING T&D VER. 5.2 OR 5.3

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

Motors Automation Energy Transmission & Distribution Coatings. Profibus DP SRW 01. User s Manual

Step 1: Choose the Appropriate CPU Step 2: Make the Connections

Installation and Programming Manual

E2 Modbus RTU Register Map

IntesisBox MAPS. Configuration & monitoring software of IntesisBox KNX series. User's manual Issue Date: 06/17 r1.0 eng

EQ7000. User Manual. Rev 1.00

M2500 Engine Controller Configuration Manual

User Manual. Thermo Scientific Orion

Ethernet/IP Module. User Manual. Contents

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

Training Sales Support

H704-42(H)(E), H704-42/1(H)(E)

Operation manual. DeviceControl NomadLink Network Control and Monitoring Software. Rev Item no. OM-DC

DATEXEL LLC. Introducing DEV 9K Version2 with converting four Modbus Flow meters to 4-20 ma. Start-up.

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

ATL20 ATL30 Automatic transfer switch controller

SMART RELAY SRW 01 V4.0X

Select Family: MicroLogix 1100 or 1400 Controller

ENGINEERING TOMORROW. User Guide. BACnet MS/TP Communication with MBS UBR-01 Router. VLT HVAC Drive FC 102 VACON 100 HVAC. vlt-drives.danfoss.

AWLaunch. Software Manual. Version 1.2 Last Revised April 27, 2009

CodeLoader. Users Guide. P/N: Rev: OCT04

A12B DNP 3.0 SERIAL & ETHERNET (TCP/IP) SCADA INTERFACE

IP Office Technical Tip

Intech Micro 2400-A16-SD

General Specifications. P2-SCM Serial Communications

SCD Live SPEED TECH A/S

FRENIC Visual Customizer

Manual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel

P-Bus Gateway Firmware

Transcription:

PowerXL PC Tools 101 2012 Eaton Corporation. All rights reserved.

Agenda Power Xpert InControl Overview Connecting Parameter Editing Power Xpert InControl Firmware Upgrade Tool Overview Configuring Loading Processors 2

Part 1: PowerXpert incontrol Overview 2012 Eaton Corporation. All rights reserved.

Power Xpert incontrol An Eaton developed FDT/DTM device configuration and control tool assisting in streamlining network commissioning over fieldbus communication systems. Customer Value: Standardized Configuration interface Remote parameter download and upload abilities Monitoring and data logging capabilities Device parameter backup files available Compatible Products: PowerXL DG1 Drives C445 Overload Relay Planned future intergration of other Eaton product platforms Competitive Products: Industry standard software allowing integration of non- Eaton devices 4

FDT & DTM Software Concept FDT program can be related to Internet Explorer which is the underlying program which opens / interacts with different web pages DTM programs can be related to individual web pages which can load multiple pages from different organizations in Internet Explorer 5

Software Framework Underlying software based on industry standard coding requirements called a field device tool (FDT) framework Base generic framework provided and maintained by FDT Group (www.fdtgroup.org) Provides common software interface for multiple products and over a variety of communication protocols 6

Software Structure Three main navigation and configuration sections of software Network View displays status of devices with quick access to configuration interfaces DTM Interface Windows device-specific information including parameterization, monitoring, and control screens Device Catalog library of device software available for loading onto the network 7

Network View Provides visual structure of network hierarchy Quick access to device configuration, integration, and advanced functions Device status color-coded to allow quick network status Online / offline / Status determines available configuration & control abilities 8

Device Catalog Used to add devices to new or existing network Displays all DTMs loaded on host computer 1-Click catalog updater simplifies updating process of DTM programs 9

DTM Configuration Interface Monitor, parameterize, or control networked devices Multiple interfaces / devices can be opened simultaneously Device network and operational status displayed on window status bars Common layout / structure across device manufactures based on FDT Standards 10

Standard Functionality Provides Live Monitor Mode Search Supports Multiple Languages Provides Detailed Parameter Descriptions Provides Detailed Fault History 11

Device Status Bar Control Place: Local or Remote Device control location Can configure parameters in either mode Device Status: Ready / Not Ready Indicates if device is ready without faults Control Place Motor Direction Device Status Run Status Fault Status Event Analyzer Trigger Device Run Status: Run / Run (Stop) Indicates state of device Fault / Warning Status: Fault / Warning/No Fault Indicates if fault or warning is active 12

Network Status Bar Device Network Status Indicates devices connection status to software Disturbed Communication timeout has occurred Locked / Unlocked Data Set Indicates if parameters can be edited and saved to device Sync Status Network Status Send/Receive Data Status Locked Status Sync Status Parameter Value Status Data set synced with device status Parameter Value Status Edited parameter Device time out Value out of Range 13

Part 2: Device Connection PowerXL DG1 2012 Eaton Corporation. All rights reserved.

RJ-45 Ethernet Connection (1 of 3) Supports fieldbus configuration and control Does NOT support firmware upgrade tool Communication protocols supported: Ethernet/IP Modbus TCP Shielded CAT-5E or higher required Supports 10/100 Mb speeds in both full / half duplex 15

USB to RJ45 (RS485) Connection (2 of 3) Port settings Baud Rate - 38.4k* Parity Even* Stop Bits 1* Data Bits 8* *Hard coded Supports full fieldbus configuration and control activated Supports firmware upgrade tool Communication protocols: Modbus RTU Data transmission through pins 1 and 2 Removes need to uninstall drive cover Can use with remote keypad mounts Catalog Number: DXG-CBL-PCCABLE 16

USB to RS-485 Connection (3 of 3) Port settings Baud Rate 19.2k* Parity Even* Stop Bits 1* Data Bits 8* *can be changed on keypad Supports fieldbus configuration and control Supports firmware upgrade tool Communication protocols supported: Modbus RTU Connected through control board terminals A (25) and B (26) When networking multiple drives, a builtin resistor for network termination is located between expansion card slots 17

Step 1: Open PowerXpert incontrol 1. To begin setting up a device network, open PowerXpert incontrol located in Start Menu a. Under EATON b. Executable through desktop shortcut c. Blank network will appear 18

Step 2: Initial Network Setup 2. Communication protocol must be added to network first. Add Communications protocol DTM by either a. Click-and-drag DTM from device catalog to unnamed network node b. Click on Network, then symbol next to desired protocol c. Right click on Network and select Add, then select desired protocol d. or 19

Step 2.2: PC USB Connection 3. Under Network View, doubleclick the Modbus Serial DTM. The tool will open a window to set Connection device settings. Select the USB communication port you are connected to the drive through. Then select apply. Note: If port is unknown, go to Control Panel, then Device Manager, then Ports to identify. 20

Step 3: Initial Network Setup 3. Select communication protocol node under Network View 4. Add PowerXL DG1 to comm. node (same as previous) or 21

Step 3.1: Modbus TCP/Ethernet IP 1. Device address will auto appear when added DG1 DTM Set the IP address for the drive (Default = 192.168.001.254) Note: Must match static IP in drive (P20.3.2) 2. Address mode must be changed on the drive. Use the keypad to change P20.3.1: IP Address Mode to Static IP. 3. Power cycle drive for new IP Address Mode to save 22

Step 3.1: PC Ethernet Port Configuration 4. The IP Address for the Ethernet port on the host computer must be set. The computer should detect the connected drive and display it in the Network and Sharing section of the control panel as an unidentified network. Set IP address of Ethernet port on PC to 192.168.001.050 a. First 3 octets ( 192.168.001 ) MUST match that of the drive b. Last octet (.050 ) CANNOT match that of the drives IP Note: Go to Control Panel, Network & Sharing, Local Area Conn., Int. Protocol Ver. 4, Properties 23

Step 3.2How to Setup Modbus Serial 1. Device slave address will auto appear Set the slave address of the drive (Software Default = 1) Click Set. 1. If using RS45-to-RJ45 Must be 18 2. If using RS485 no restriction 2. The slave address on the drive must match what is set in step 1. Use the drives keypad to change P20.2.2: Slave Address to match what was set in the software 24

Step 4: Connecting the Drive 1. After setting up Communication device, Right click on the added Drive and select Connect. Then Double Click on the Drive. The drive window will Open, bottom of window shows drive is connected. 2. The PowerXL DG1 is now ready for programming and configuration. 25

Firmware Upgrade PowerXL DG1 2012 Eaton Corporation. All rights reserved.

USB to RJ45 (RS485) Connection Catalog Number: DXG-CBL-PCCABLE 27

Firmware Upgrade Tool Installed with One Installer or via separate link Download Bundled DG_VXX.XX.XXXX Firmware File - DG_BXX.XX.XXXX Configuration File - DG_CXX.XX.XXXX Select this file in Config file area Select Com port Select Slave Address of Drive Click Connect 28

Firmware Upgrade Tool All processors will be checked by default if code is not updated. Click Program Progress bars are shown for each processor When finished click Disconnect. Plug Keypad in Upload firmware to keypad, press Ok 29

30