Cable End Boxes Series 8146

Similar documents
Terminal Boxes Series 8118

Load Disconnect Switches and Motor Switches

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Position Switches Series 8070

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

Control Buttons / Switches for Panel Mounting Series 8003

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2

Tubular Light Fitting with LED Series 6036

Micro Limit Switch Series 8064

Grounding Monitoring Device Series 8485

Grounding Monitoring Device Series 8485

SolConeX Wall-Mounted Socket, 16 A

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Control Switches for Panel Mounting Series 8003

Linear Luminaire with LED Series 6012/5

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Operating and monitoring systems Thin Client SERIES 500 Device platform EAGLE PM ET-556-TX

Linear Luminaire with LED Series 6412/5

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM ET-436-TX

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE PM MT-336-FX

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

Ex-control switch Typ 292 without and Typ 293 with measuring instrument

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM MT-436-TX

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Miniature Circuit-Breaker IEC Series 8562

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS ET-306-FX

Technical Datasheet. Connectors, Plugs & Sockets. Table of Contents. Selection Guide 2. 16A Range (ELCX ) 3. 32A Range (ELCX

Bayonet resistance thermometer Model TR53

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Ground Monitoring Device Series 8485

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS MT-316-TX

Standard enclosure for Remote I/O Series 8150

Threaded resistance thermometer Miniature design Model TR10-D

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

2.3. Ex-Linear light fittings for fluorescent lamps. ellk W 58 W / ellm W 36 W (Zone 1, 2, 21, 22)

Loads and Motor Switchgears

IECEx Certificate of Conformity

Threaded thermocouple Miniature design Model TC10-D

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

Ex magnetic safety sensors, cylindrical form // Series EEx RC Si M30

Resistance thermometer With spring-loaded tip Model TR55

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Ex emergency pull-wire switches Ex ZS 71

CPU module for zone 2 Series 9442/35

GRP Flameproof Visual Signal Xenon or Steady LED

Cradle relay AC. Electrical data Operating data (coil circuit) U N. Explosion protection Marking ATEX. II 2G Ex db e IIC Gb I M2 Ex db e I Mb I N

Throughwiring. single-ended. twin-ended

Technical Data. General specifications. Rated operating distance s n 3 mm

Cable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof

21023, 21025, 2/2 Direct solenoid actuated poppet valves

INSTALLATION TECHNOLOGY MADE EASY

XLF. Ex d. - Zones 1, 2, 21, 22 - Obstruction warnings - Stroboscopic lights - Single or double fixtures - Low wind resistance

Series Panel Mounted Control Devices

SolConeX extra-low voltage flange socket

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

KINAX WT720 absolute, programmable angular postion transmitter

Resistance thermometer For additional thermowell Model TR10-B

Operating and monitoring systems Panel PC SERIES 400 Device platform SHARK ET-498-2TX

5 Fieldbus Technology

Ex Junction Boxes & Control Stations

Modern, sunlight-readable 7" colour display

General Specifications

Threaded resistance thermometer With protection tube Model TR10-C

Threaded resistance thermometer Model TR10-C, with protection tube

The 470-Z1 consists of an aluminium enclosure, which has the supply / interface connections either via the bottom side or enclosure back panel.

IECEx Certificate of Conformity

NAMUR INDUCTIVE SENSOR ATEX/IECEx

Operating pressure. N/en/en

Operating and monitoring systems Panel PC SERIES 400 Device platform SHARK ET-438-2FX

Supplementary Components WirelessHART products

Operating pressure. N/en/en

SKX 12 SKX 15. Zone. make your work surroundings safer IP 66

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety

95100, 2/2 (stainless steel) Direct solenoid actuated poppet valves

General Specifications

Reed sensor For bypass level indicators Model BLR

IECEx Certificate of Conformity

Product manual plug, sockets and coupler 16 A.- Z0251

Control Stations & Switches: Switches, Circuit Breakers and "Break Glass" Call Points SWE Series: 16 and 20 A Switches Increased Safety

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Technical Information Promonitor NRF560

3.2. Ex-d/e Cable Glands Metal Design. For Zone 1, 2, 21 and 22 according EN :2012 / IEC : 2011

ET-208-7" (800 x 480)

versatile connectors for any application

Series 95000, 2/2 Direct solenoid actuated poppet valve

IECEx Certificate of Conformity

Sicherheit, auf die Sie sich verlassen können

M C. Ex d M-0... control, monitoring and signalling devices

Operating pressure (bar) kv factor (m 3 /h) *3)

24011 series, 3/2 Direct solenoid actuated poppet valve

IECEx Certificate of Conformity

Installation Equipments

Transcription:

> Enclosures glass fibre reforced polyester res > For termals from 35... 185 mm 2 > Rated operational current up to max. 400 A dependg on enclosure version and size > Degree of protection IP55 www.stahl.de 01367E00 The cable end boxes of the can be fitted with termals up to a size of 185 mm 2. The entry and exit cables are led through cable entry plates to the enclosure where they are fixed with stra relief clamps ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 8146/1: For use x x x x 8146/1: For use x x 8146/1: For use x x x 8146/2: For use *) Approval not required x x x x 8146/2: For use Explosion Protection Global (IECEx) Gas and dust IECEx PTB 06.0046 *) *) 8146/2: For use x x x WebCode 8146B Installation Equipment /1

Explosion Protection Ex d e ia/ib [ia Ga] mb IIA, IIB, IIC T6, T5, T4 Gb Ex tb IIIA, IIIB, IIIC, T80 C, T95 C, T130 C Db IP66 Europe (ATEX) Gas and dust PTB 01 ATEX 1016 E II 2 G Ex d e ia/ib [ia Ga] mb IIA, IIB, IIC T6, T5, T4 Gb E II 2 D Ex tb IIIA, IIIB, IIIC T80 C, T95 C, T130 C Db IP66 Certifications and certificates Certificates IECEx, ATEX, Cha (Cha-Ex), Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K), Korea (KCs), Russia (GOST R), Taiwan (ITRI), Ukrae (TR), Belarus (operatg authorisation), USA (UL) Ship approval GL, RS Selection Table Version Termals Rated current dependg on the temperature class Cable End Boxes Polyester Res 12 stud termals 400 A / T5 315 A / T6 PE termals (size / number) (4 pieces) Arrangement Order number Weight 8146/1000-C923 28.700 07946E00 6 stud termals 400 A / T5 315 A / T6 (2 pieces) 8146/1093-C924 14.000 07945E00 6 le-up termals 70 mm 160 A / T5 125 A / T6 70 mm (2 pieces) 8146/1000-C958 9.500 07944E00 Technical Data Electrical data Version 8146/1000-C923 8146/1093-C924 8146/1000-C958 Rated operational voltage max. 750 V AC max. 750 V AC max. 750 V AC Rated current dependg 315 A / T6400 A / T5 315 A / T6400 A / T5 125 A / T6160 A / T5 on the temperature class Ambient conditions Ambient temperature -40... +55 C Mechanical data Version 8146/1000-C923 8146/1093-C924 8146/1000-C958 Type of protection Termals 2 12 stud termals 4 PE stud termals 185 mm 2 M12 185 mm 2 ; 6 stud termals M12 185 mm2 ; 2 PE stud termals 185 mm 2 8 le-up termals 70 mm Dimensions 696,3 x 682,2 x 150 mm 696,3 x 340,5 x 150 mm 526,5 x 340,5 x 150 mm Mountg / Installation Version 8146/1000-C923 8146/1093-C924 8146/1000-C958 Cable entry brass plate with 2 x M75 brass plate with 2 x M75 brass plate with 2 x M75 Please order screw connection separately, see accessories Please order screw connection separately, see accessories Please order screw connection separately, see accessories Internal wirg Copper bar 20 x 10 mm (E-Cu F30) Copper bar 20 x 10 mm (E-Cu F30) Cable NSGAFöu 70; 70mm /2 Installation Equipment

Flange Size 1 2.8 mm thick 135978 0.077 05742E00 Size 1 5.8 mm thick 136032 0.106 can be mounted on enclosue Enclosure side / / / / Size 2 2.8 mm thick 136045 0.210 05741E00 Size 2 5.8 mm thick can be mounted on enclosue Enclosure side 136083 0.317 8146/.073 /.075 /.085 /.095 /.086 / / Size 3 2.8 mm thick 136199 0.115 05743E00 Size 3 5.8 mm thick can be mounted on enclosue Enclosure side 136237 0.166 8146/.073 /.075 Frames Size 0 68 x 68 mm 136012 0.014 Size 1 68 x 128 mm 135974 0.020 04901E00 Size 2 126 x 266 mm Size 3 126 x 126 mm 136031 0.041 136235 0.027 Brass plate 2 mm for flanges 1) 2) for flange size 1 (68 x 128 mm) 136888 0.040 for flange size 2 for flange size 3 (126 x 266 mm) (126 x 126 mm) 136960 0.220 136963 0.120 Brass plate 3 mm for flanges 1) for flange size 1 for flange size 2 (68 x 128 mm) (126 x 266 mm) 136201 0.200 136568 0.100 for flange size 3 (126 x 126 mm) 136726 0.320 Installation Equipment /3

Brass plate 2 mm for enclosure 1) 2) for enclosure Enclosure sides 8146/.031 8146/.041 136940 0.040 8146/.041 136945 0.060 136914 0.050 136921 0.070 136933 0.080 C1 / D1 136927 0.140 8146/.073 136975 0.140 8146/.073 C1 / D1 136977 0.270 136950 0.160 136973 0.100 136979 0.310 C2 / D2 C2 / D2 136957 0.160 136982 0.310 /4 Installation Equipment

Brass plate 3 mm for enclosure 1) for enclosure Enclosure sides 8146/.031 8146/.041 8146/.041 136395 0.100 136403 0.160 8146/.041 136635 0.150 136240 0.140 136283 0.200 136430 0.560 C 1 / D1 136374 0.200 136313 0.400 136451 0.560 8146/.073 8146/.073 8146/.073 C1 / D1 136616 0.410 136631 0.770 136621 0.810 136544 0.460 136611 0.265 136626 0.880 Serrated lock washer for M25 110706 0.009 for M32 110707 0.007 09717E00 for M40 110708 0.021 for M50 for M63 110709 0.040 110710 0.060 Adaptor for reduction to thread size M63 222541 0.200 16546E 00 Installation Equipment /5

Cable gland 14977E00 Cable gland M75 clampg range 61.1 to 68.0 mm 138781 0.410 Cable gland M75 clampg range 54.0 to 62.0 mm 138782 0.420 Cable gland M63 clampg range 47.2 to 56.0 mm 138779 0.350 for use with adaptor 222541 Cable gland M63 clampg range 41.5 to 50.0 mm for use with adaptor 222541 138780 0.370 1) For earthg metal gland parts when used moulded plastic enclosures and plastic flanges 2) - If the connectg cable is equipped with an armour which is larger than 6 mm 2 and which is used as earthg conductor, a brass plate with a thickness of 3 mm must be used. - Due to the higher stra on the enclosure wall, the 3 mm brass plate has also to be used for large bell mounted glands. Dimensional drawgs (all dimensions mm) - subject to alterations 04175E00 04178E00 04179E00 8146/1000-C958 8146/1093-C924 8146/1000-C923 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered bdg. /6 Installation Equipment