K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. c LC-K060ii a.c. control contactors () Standard power ratings Rated Type of Instantaneous Basic reference. Weight of 3-phase motors operational connection auxiliary Complete with code 50/60 Hz in category voltage contacts indicating control AC-3 in AC-3 circuit voltage (2) up to 220 V 380 V 440/500 V 400 V 230 V V 660/690 V kw kw kw A N/O N/C kg.5 2.2 3 6 Screw clamp LC-K060ii 0.80 LC-K060ii 0.80 Faston LC-K0607ii 0.80 x 6.35 LC-K0607ii 0.80 Solder pins LC-K0605ii 0.20 for printed LC-K0605ii 0.20 2.2 4 4 9 Screw clamp LC-K090ii 0.80 LC-K090ii 0.80 Faston LC-K0907ii 0.80 x 6.35 LC-K0907ii 0.80 Solder pins LC-K0905ii 0.20 for printed LC-K0905ii 0.20 a.c. control contactors for use in sensitive environments () Recommended for use in areas sensitive to noise, high interference mains supplies, etc. - Coil with rectifier incorporated, suppressor fitted as standard. - Screws in the open ready-to-tighten position..5 2.2 3 6 Screw clamp LC7-K060ii 0.225 LC7-K060ii 0.225 Faston LC7-K0607ii 0.225 x 6.35 LC7-K0607ii 0.225 Solder pins LC7-K0605ii 0.255 for printed LC7-K0605ii 0.255 2.2 4 4 9 Screw clamp LC7-K090ii 0.225 LC7-K090ii 0.225 Faston LC7-K0907ii 0.225 x 6.35 LC7-K0907ii 0.225 Solder pins LC7-K0905ii 0.255 for printed LC7-K0905ii 0.255 () Add-on auxiliary contact blocks and accessories, see pages /8 to /. (2) Standard control circuit voltages, see page opposite. Contactors LC-K, LC7-K, LP-K On panel LA-K 4xØ4 On mounting rail AM-DP200 or AM-DE200 (" 35 mm) 3 = 50 = = 35 = /2 Te
K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : d.c. a LP-K060ii d.c. control contactors () Standard power ratings Rated Type of Instantaneous Basic reference. Weight of 3-phase motors operational connection auxiliary Complete with code 50/60 Hz in category voltage contacts indicating control AC-3 in AC-3 circuit voltage (2) up to 220 V 380 V 440/500 V 400 V 230 V V 660/690 V kw kw kw A N/O N/C kg.5 2.2 3 6 Screw clamp LP-K060ii 0.225 LP-K060ii 0.225 Faston LP-K0607ii 0.225 x 6.35 LP-K0607ii 0.225 Solder pins LP-K0605ii 0.255 for printed LP-K0605ii 0.255 2.2 4 4 9 Screw clamp LP-K090ii 0.225 LP-K090ii 0.225 Faston LP-K0907ii 0.225 x 6.35 LP-K0907ii 0.225 Solder pins LP-K0905ii 0.255 for printed LP-K0905ii 0.255 () Add-on auxiliary contact blocks and accessories, see pages /8 to /. (2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Contactors LC-K (0.8.5 Uc) (0.85. Uc) Volts c 2 20 24 36 42 48 0 20 27 200/ 220/ 230 230/ 256 277 380/ 400 50/60 Hz 208 230 240 400 Code J7 Z7 B7 C7 D7 E7 F7 G7 FC7 L7 M7 P7 U7 W7 UE7 Q7 V7 Volts c 400/ 440 500 5 600 660/ 50/60 Hz 690 Code N7 R7 S7 SC7 X7 Y7 Up to and including 240 V, coil with integral suppression device available : add 2 to the code required. Example : J72 Contactors LC7-K (0.85. Uc) Volts c 24 42 48 0 220 230/ 50/60 Hz 240 Code B7 D7 E7 F7 M7 U7 Contactors LP-K (0.8.5 Uc) Volts a 2 20 24 36 48 60 72 00 0 25 55 74 200 220 230 240 250 Code JD ZD BD CD ED ND SD KD FD GD PD QD LD MD MPDMUD UD Coil with integral suppression device available : add 3 to the code required. Example : JD3 Contactors LC-K, LC7-K, LP-K On one asymmetrical rail DZ5-MB with clip-on mounting plate LA9-D973 DX-AP25 On printed DZ5-ME5 50 5 20 0 8,65 === 50 A 53 2 = 35 = 5 0xØ,3 A2 27 Te /3
Dimensions : pages /2 and /3 Mini contactors K 3 and 4-pole contactors for heating, lighting, etc., 20 A Utilisation category AC- Control circuit : a.c. and d.c. c a.c. control contactors () - Mounting on 35 mm " rail or Ø 4 mm screws. Non inductive Type of Number Instantaneous Basic reference. Weight loads connection of auxiliary Complete with code Category poles contacts indicating control AC- circuit voltage (2) Maximum current at θ 50 C A N/O N/C kg LC-K09004ii 20 Screw clamp 3 LC-K090ii 0.225 3 LC-K090ii 0.225 4 LC-K09004ii 0.80 2 2 LC-K09008ii 0.80 Faston 3 LC-K0907ii 0.225 x 6.35 3 LC-K0907ii 0.225 4 LC-K090047ii 0.80 2 2 LC-K090087ii 0.80 Solder pins 3 LC-K0905ii 0.255 for printed 3 LC-K0905ii 0.255 4 LC-K0900ii 0.20 2 2 LC-K090085ii 0.22 a.c. control contactors for use in sensitive environments () Recommended for use in areas sensitive to noise, high interference mains supplies, etc. - Coil with rectifier incorporated, suppressor fitted as standard. 20 Screw clamp 3 LC7-K090ii 0.225 3 LC7-K090ii 0.225 4 LC7-K09004ii 0.225 2 2 LC7-K09008ii 0.225 Faston 3 LC7-K0907ii 0.225 x 6.35 3 LC7-K0907ii 0.225 4 LC7-K090047ii 0.225 2 2 LC7-K090087ii 0.225 Solder pins 3 LC7-K0905ii 0.255 for printed 3 LC7-K0905ii 0.255 4 LC7-K0900ii 0.255 2 2 LC7-K090085ii 0.255 d.c. control contactors () 20 Screw clamp 3 LP-K090ii 0.225 3 LP-K090ii 0.225 4 LP-K09004ii 0.225 2 2 LP-K09008ii 0.225 Faston 3 LP-K0907ii 0.225 x 6.35 3 LP-K0907ii 0.225 4 LP-K090047ii 0.225 2 2 LP-K090087ii 0.225 Solder pins 3 LP-K0905ii 0.255 for printed 3 LP-K0905ii 0.255 4 LP-K0900ii 0.255 2 2 LP-K090085ii 0.255 () Add-on auxiliary contact blocks and accessories, see pages /8 to /. (2) Standard control circuit voltages, see page /3. /4 Te
Dimensions : page /6 Mini contactors K 3-pole reversing contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. and d.c. c a.c. control reversing contactors () LC2-K060ii - Integral mechanical interlock. - Pre-wired power circuit connections as standard on screw clamp versions. Standard power ratings Rated Type of Instantaneous Basic reference. Weight of 3-phase motors operational connection auxiliary Complete with code 50/60 Hz in category current contacts indicating control AC-3 in AC-3 circuit voltage (2) up to 220 V 380 V 440/500 V 400 V 230 V V 660/690 V kw kw kw A N/O N/C kg.5 2.2 3 6 Screw clamp LC2-K060ii 0.390 LC2-K060ii 0.390 Faston LC2-K0607ii 0.370 x 6.35 LC2-K0607ii 0.370 Solder pins LC2-K0605ii 0.430 for printed LC2-K0605ii 0.430 2.2 4 4 9 Screw clamp LC2-K090ii 0.390 LC2-K090ii 0.390 Faston LC2-K0907ii 0.370 x 6.35 LC2-K0907ii 0.370 Solder pins LC2-K0905ii 0.430 for printed LC2-K0905ii 0.430 a.c. control reversing contactors for use in sensitive environments () Recommended for use in areas sensitive to noise, high interference mains supplies, etc. - Coil with rectifier incorporated, suppressor fitted as standard. - Integral mechanical interlock. - Pre-wired power circuit connections as standard on screw clamp versions. - Mounting on " 35 mm rail or Ø 4 mm screw fixing..5 2.2 3 6 Screw clamp LC8-K060ii 0.480 LC8-K060ii 0.480 Faston LC8-K0607ii 0.460 x 6.35 LC8-K0607ii 0.460 Solder pins LC8-K0605ii 0.520 for printed LC8-K0605ii 0.520 2.2 4 4 9 Screw clamp LC8-K090ii 0.480 LC8-K090ii 0.480 Faston LC8-K0907ii 0.460 x 6.35 LC8-K0907ii 0.460 Solder pins LC8-K0905ii 0.520 for printed LC8-K0905ii 0.520 d.c. control reversing contactors ().5 2.2 3 6 Screw clamp LP2-K060ii 0.480 LP2-K060ii 0.480 Faston LP2-K0607ii 0.460 x 6.35 LP2-K0607ii 0.460 Solder pins LP2-K0605ii 0.520 for printed LP2-K0605ii 0.520 2.2 4 4 9 Screw clamp LP2-K090ii 0.480 LP2-K090ii 0.480 Faston LP2-K0907ii 0.460 x 6.35 LP2-K0907ii 0.460 Solder pins LP2-K0905ii 0.520 for printed LP2-K0905ii 0.520 () Auxiliary contact blocks and accessories, see pages /8 to /. (2) Control circuit voltage codes, see page /7. Te /5
K 3 and 4-pole changeover contactors for heating, lighting, etc., 20 A Utilisation category AC- Control circuit : a.c. c a.c. control reversing contactors () - Integral mechanical interlock. Non inductive Type of Number Instantaneous Basic reference. Weight loads connection of auxiliary Complete with code Category poles contacts indicating control AC- circuit voltage (2) Maximum current at θ 50 C A N/O N/C kg 20 Screw clamp 3 LC2-K090ii (3) 0.390 3 LC2-K090ii (3) 0.390 4 LC2-K09004ii 0.380 Faston 3 LC2-K0907ii 0.370 x 6.35 3 LC2-K0907ii 0.370 4 LC2-K090047ii 0.370 LC2-K090ii Solder pins 3 LC2-K0905ii 0.430 for printed 3 LC2-K0905ii 0.430 4 LC2-K0900ii 0.430 a.c. control reversing contactors for use in sensitive environments () Recommended for use in areas sensitive to noise, high interference mains supplies, etc. - Coil with rectifier incorporated, suppressor fitted as standard. - Integral mechanical interlock. - Mounting on " 35 mm rail or Ø 4 mm screw fixing. 20 Screw clamp 3 LC8-K090ii (3) 0.480 3 LC8-K090ii (3) 0.480 4 LC8-K09004ii 0.470 Faston 3 LC8-K0907ii 0.460 x 6.35 3 LC8-K0907ii 0.460 4 LC8-K090047ii 0.460 Solder pins 3 LC8-K0905ii 0.520 for printed 3 LC8-K0905ii 0.520 4 LC8-K0900ii 0.520 () Add-on auxiliary contact blocks and accessories, see pages /8 to /. (2) Control circuit voltage codes, see page opposite. (3) Warning: this reversing contactor is pre-wired for reverse motor operation as standard. Reversing contactors LC2-K, LC8-K, LP2-K On panel LA-K 8xØ4 On mounting rail AM-DP200 or AM-DE200 ( " 35 mm) 3 90 = 50 = = 80 = 90 /6 Te
K 3 and 4-pole changeover contactors for heating, lighting, etc., 20 A Utilisation category AC- Control circuit : d.c. a LP2-K090ii d.c. control reversing contactors () - Integral mechanical interlock. Non inductive Type of Number Instantaneous Basic reference. Weight loads connection of auxiliary Complete with code Category poles contacts indicating control AC- circuit voltage (2) Maximum current at θ 50 C A N/O N/C kg 20 Screw clamp 3 LP2-K090ii (3) 0.480 3 LP2-K0900ii (3) 0.480 4 LP2-K09004ii 0.480 Faston 3 LP2-K0907ii 0.460 x 6.35 3 LP2-K0907ii 0.460 4 LP2-K090047ii 0.460 Solder pins 3 LP2-K0905ii 0.520 for printed 3 LP2-K0905ii 0.520 4 LP2-K0900ii 0.520 () Add-on auxiliary contact blocks and accessories, see pages /8 to /. (2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Reversing contactors LC2-K (0.8.5 Uc) (0.85. Uc) Volts c 2 20 24 36 42 48 0 20 27 200/ 220/ 230 230/ 256 277 380/ 400 50/60 Hz 208 230 240 400 Code J7 Z7 B7 C7 D7 E7 F7 G7 FC7 L7 M7 P7 U7 W7 UE7 Q7 V7 Volts c 400/ 440 500 5 600 660/ 50/60 Hz 690 Code N7 R7 S7 SC7 X7 Y7 Up to and including 240 V, coil with integral suppression device available : add 2 to the code required. Example : J72 Reversing contactors LC8-K (0.85. Uc) Volts c 24 42 48 0 220 230/ 50/60 Hz 240 Code B7 D7 E7 F7 M7 U7 Reversing contactors LP2-K (0.8.5 Uc) Volts a 2 20 24 36 48 60 72 00 0 25 55 74 200 220 230 240 250 Code JD ZD BD CD ED ND SD KD FD GD PD QD LD MD MPD MUD UD Coil with integral suppression device available : add 3 to the code required. Example : JD3 (3) Warning: this reversing contactor is pre-wired for reverse motor operation as standard. On one asymmetrical rail DZ5-MB with 2 clip-on mounting plates LA9-D973 or on 2 mounting plates DX-AP25. 2 x LA9-D973 2 x DX-AP25 DZ5-ME5 50 5 20 0 2 = 35 = 90 5 On printed for reversing contactors or 2 contactors mounted side by side 27 90 8,65 === = = = 8,65 A A A2 A2 50 53 20xØ,3 Te /7
LC,LC7,LP-K06,K09 LA-KN LA-KN M LC,LC7,LP-K06,K09 LA-KN LA2-KT2 LC,LC7,LP-K09 LA-KN P /8 Te
K 3 and 4-pole contactors, reversing and changeover contactors Instantaneous and time delay auxiliary contacts Illustrations : page /8 Instantaneous auxiliary contact blocks Recommended for standard applications Clip-on front mounting, block per contactor Type of connection Type of contactor Composition Reference Weight LA-KN40ii ii N/O N/C kg Screw clamp LC, LC7, LP 2 LA-KN20 0.0 3 or 4-pole 2 LA-KN02 () 0.0 LA-KN (2) 0.0 4 LA-KN40 0.0 3 LA-KN3 0.0 2 2 LA-KN22 0.0 3 LA-KN3 (3) 0.0 4 LA-KN04 (4) 0.0 Faston LC, LC7, LP 2 LA-KN207 0.0 x 6.35 3 or 4-pole 2 LA-KN027 0.0 LA-KN7 0.0 4 LA-KN407 0.0 3 LA-KN37 0.0 2 2 LA-KN227 0.0 3 LA-KN37 0.0 4 LA-KN047 0.0 With terminal referencing conforming to standard EN 5002 Clip-on front mounting, block per contactor Screw clamp LC, LC7, LP 2 LA-KN02M 0.0 3-pole LA-KNM 0.0 6 and 9 A 3 LA-KN3M 0.0 2 2 LA-KN22M 0.0 3 LA-KN3M 0.0 LC, LC7, LP LA-KNP 0.0 4-pole 2 2 LA-KN22P 0.0 9 A () Cannot be used on contactors : LP4/LP5-Kii0, LP4/LP5-K09008. (2) Cannot be used on contactors : LP4/LP5-K09008. (3) Cannot be used on contactors : LC7/LC8/LP/LP2-K09008. (4) Cannot be used on contactors : LC7/LC8/LP/LP2-Kii0, LC7/LC8/LP/LP2-K09008. Electronic time delay auxiliary contact blocks - Relay output, with common point changeover contact, 2 A maximum. - Control voltage : c or a 24 48 V, c 0 240 V, 0.85. Uc. - Maximum switching capacity : 250 VA or 50 W. - Operating temperature : -0 + 60 C. - Reset time :.5 s during the time delay period, 0.5 s after the time delay period. Clip-on front mounting, block per contactor Voltage Type Timing Composition Reference Weight range V s C/O kg c or a 24 48 On-delay 30 LA2-KT2E 0.040 c 0 240 On-delay 30 LA2-KT2U 0.040 Electronic time delay contact blocks LA2-KT On contactors On reversing contactors LA2-KT LA2-KT 27 34 38 34 34 Te /9
K 3 and 4-pole contactors, reversing and changeover contactors Suppressor modules incorporating LED indicator Mounting Type For voltages: Sold in Unit Weight and connection lots of reference kg Clip-on fixing Varistor c and a 5 LA4-KEB 0.00 on the front of () 2 24 V contactors LC, LC2, LP and LP2 c and a 5 LA4-KEE 0.00 32 48 V LA4-Kiii c and a 5 LA4-KEFC 0.00 50 29 V c and a 5 LA4-KEUG 0.00 30 250 V Diode + a 5 LA4-KCB 0.00 Zener diode (2) 2 24 V a 5 LA4-KCE 0.00 32 48 V RC (3) c 5 LA4-KAU 0.00 220 250 V () Protection by limitation of the transient voltage up to 2 Uc maximum. Maximum reduction of transient voltage peaks. Slight time delay on drop-out (. to.5 times the normal time). (2) No overvoltage or oscillation frequency. Polarised component. Slight time delay on drop-out (. to.5 times the normal time). (3) Protection by limitation of the transient voltage up to 3 Uc maximum and limitation of the oscillation frequency. Slight time delay on drop-out (.2 to 2 times the normal time). Suppressor modules LA4-Ki On contactors On reversing contactors 25 22 6 22 22 /0 Te
K 3 and 4-pole contactors, reversing and changeover contactors Accessories Dimensions : pages /3 and /7 Mounting and marking accessories Description Application Sold in Unit Weight lots of reference kg Mounting For fixing Clip-on LA9-D973 0.025 plates () on ' rail For fixing 0/20 mm DX-AP25 0.065 on 2 ' rails fixing centres Marker Clip-on Onto front of 00 LA9-D90 0.00 holder contactor Clip-in 4 maximum Strips of 25 AB-Ri (2) 0.002 markers per contactor 0 identical numbers 0 9 Strips of 25 AB-Gi (2) 0.002 0 identical capital letters A Z Cabling accessories Description Application Sold in Unit Weight lots of reference kg Paralleling For 2 poles 4 LA9-E0 0.00 links with screw clamp terminals For 4 poles 2 LA9-E02 0.05 with screw clamp terminals Set of 6 power For 3-pole For contactors 00 LA9-K0969 0.00 connections reversing with screw contactors for clamp terminals motor control Set of 4 power For 4-pole For contactors 00 LA9-K0970 0.00 connections changeover with screw contactor clamp terminals pairs () Order mounting plate for fixing a contactor and 2 mounting plates for fixing a reversing contactor. (2) Complete the reference by replacing the i with the required character. Te /
Mini thermal overload relays K thermal overload relays, adjustable from 0. to.5 A, for motor protection; compensated and phase failure sensitive, manual or automatic reset 3-pole relays with screw clamp terminals Direct mounting : under the contactor for versions with screw clamp terminals only; pre-wired terminals, see below. Separate mounting : using terminal block LA7-K0064 (see below). On the front of the overload relay : - selection of reset mode : Manual (marked H) or Automatic (marked A), - red pushbutton : Trip Test function, - red pushbutton : Trip reset, - blue pushbutton : Stop and manual Reset, - yellow trip flag indicator : overload relay tripped. Protection by fuses or by magnetic circuit-breaker type GV2-L, see page /92. Relay Fuses to be used with selected relay Reference Weight setting Maximum rating range Type am gg (BS88) A A A kg Class 0 A (the standard specifies a tripping time of between 2 and 0 seconds at 7.2 In) 0. 0.6 0.25 2 LR2-K030 0. LR2-K030 0.6 0.23 0.25 2 LR2-K0302 0. 0.23 0.36 0.5 2 LR2-K0303 0. 0.36 0.54 4 LR2-K0304 0. 0.54 0.8 4 LR2-K0305 0. 0.8.2 2 6 LR2-K0306 0..2.8 2 6 LR2-K0307 0..8 2.6 4 0 LR2-K0308 0. 2.6 3.7 4 6 LR2-K030 0. 3.7 5.5 6 6 LR2-K032 0. 5.5 8 8 20 LR2-K034 0. 8.5 0 20 LR2-K036 0. LR2-K Direct mounting under the contactor 8 = 50 = = 35 = 4xØ4 6 65 /2 Te
Mini thermal overload relays K thermal overload relays, adjustable from 0. to.5 A, for motor protection; compensated and phase failure sensitive, manual or automatic reset Accessories for thermal overload relays Description Type of connection Reference Weight kg Terminal block for separate Screw clamp LA7-K0064 0.00 clip-on mounting of the overload relay on 35 mm " rail Separate mounting with terminal block LA7-K0064 on 35 mm " rail (AM-DP200 or AM-DE200) 80 38 75 c AM- C DP200 78.5 DE200 86 Te /3
K 3 and 4-pole low consumption contactors for motor control (AC-3) and heating and lighting, etc. (AC-) Control circuit : d.c. a d.c. control contactors () - Compatible with programmable controller outputs. - LED indicator incorporated. - Wide range coil (0.7.30 Uc), suppressor fitted as standard, consumption.5 W. Motor control Type of Instantaneous Basic reference. Weight in category AC-3 connection auxiliary Complete with code Maximum Standard contacts indicating control opera- power ratings circuit voltage (2) tional of 3-phase current motors 440 V 220 V 380 V 440/500 V 230 V V 660/690 V A kw kw kw N/O N/C kg LP4-K060 6.5 2.2 3 Screw clamp LP4-K060iii 0.235 LP4-K060iii 0.235 Faston x 6.35 LP4-K0607iii 0.235 LP4-K0607iii 0.235 Solder pins LP4-K0605iii 0.265 for printed LP4-K0605iii 0.265 9 2.2 4 4 Screw clamp LP4-K090iii 0.235 LP4-K090iii 0.235 Faston x 6.35 LP4-K0907iii 0.235 LP4-K0907iii 0.235 Solder pins LP4-K0905iii 0.265 for printed LP4-K0905iii 0.265 Non Type of Number Instantaneous Basic reference. Weight inductive connection of auxiliary Complete with code loads poles contacts indicating control Cat. AC- circuit voltage (2) θ 50 C Maximum current A N/O N/C kg 20 Screw clamp 3 LP4-K090iii 0.235 3 LP4-K090iii 0.235 4 LP4-K09004iii 0.235 2 2 LP4-K09008iii 0.235 Faston x 6.35 3 LP4-K0907iii 0.235 3 LP4-K0907iii 0.235 4 LP4-K090047iii 0.235 2 2 LP4-K090087iii 0.235 Solder pins 3 LP4-K0905iii 0.265 for printed 3 LP4-K0905iii 0.265 4 LP4-K0900iii 0.265 2 2 LP4-K090085iii 0.265 () Add-on auxiliary contact blocks and accessories, see pages /6 and /7. (2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Volts a 2 24 48 72 Code JW3 BW3 EW3 SW3 Contactors LP4-K On panel LA-K 3 /4 Te = 50 = 4xØ4 = 35 = On mounting rail AM-DP200 or AM-DE200 (" 35 mm)
K 3 and 4-pole low consumption reversing and changeover contactors for motor control (AC-3) and heating, lighting etc., (AC-) Control circuit : d.c. a d.c. control reversing and changeover contactors () - Compatible with programmable controller outputs. - LED indicator incorporated. - Wide range coil (0.7.30 Uc), suppressor fitted as standard, consumption.5 W. - Mechanical interlock incorporated. - Pre-wired power circuit connections as standard on screw clamp versions. Motor control Type of Instantaneous Basic reference. Weight in category AC-3 connection auxiliary Complete with code Maximum Standard contacts indicating control opera- power ratings circuit voltage (2) tional of 3-phase current motors 440 V 220 V 380 V 440/500 V 230 V V 660/690 V A kw kw kw N/O N/C kg 6.5 2.2 3 Screw clamp LP5-K060iii 0.490 LP5-K060iii 0.490 Faston x 6.35 LP5-K0607iii 0.470 LP5-K0607iii 0.470 Solder pins LP5-K0605iii 0.530 for printed LP5-K0605iii 0.530 9 2.2 4 4 Screw clamp LP5-K090iii 0.490 LP5-K090iii 0.490 Faston x 6.35 LP5-K0907iii 0.470 LP5-K0907iii 0.470 Solder pins LP5-K0905iii 0.530 for printed LP5-K0905iii 0.530 LP5-K090iii Non Type of Number Instantaneous Basic reference. Weight inductive connection of auxiliary Complete with code loads poles contacts indicating control Cat. AC- circuit voltage (2) θ 50 C Maximum current Reversing contactors LP5-K On panel LA-K 8xØ4 A N/O N/C kg 20 Screw clamp 3 LP5-K090iii (3) 0.490 3 LP5-K090iii (3) 0.490 4 LP5-K09004iii 0.490 Faston x 6.35 3 LP5-K0907iii 0.470 3 LP5-K0907iii 0.470 4 LP5-K090047iii 0.470 Solder pins 3 LP5-K0905iii 0.530 for printed 3 LP5-K0905iii 0.530 4 LP5-K0900iii 0.530 () Add-on auxiliary contact blocks and accessories, see pages /6 and /7. (2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Volts a 2 24 48 72 Code JW3 BW3 EW3 SW3 (3) Warning: this reversing contactor is pre-wired for reverse motor operation. On mounting rail AM-DP200 or AM-DE200 (" 35 mm) 3 = 80 90 = = 50 = 90 Te /5
K 3 and 4-pole low consumption contactors, reversing and changeover contactors Instantaneous and time delay auxiliary contacts Instantaneous auxiliary contact blocks Clip-on front mounting, block per contactor Type of Type of Composition Reference Weight connection contactor N/O N/C kg Screw clamp 3 or 4-pole 2 LA-KN20 0.0 2 LA-KN02 0.0 LA-KN 0.0 Faston 3 or 4-pole 2 LA-KN207 0.0 x 6.35 2 LA-KN027 0.0 LA-KN7 0.0 With terminal referencing conforming to standard EN 5002 Clip-on front mounting, block per contactor Screw clamp 3-pole, 2 LA-KN02M 0.0 6 and 9 A LA-KNM 0.0 4-pole, 9 A LA-KNP 0.0 Electronic time delay auxiliary contact blocks - Relay output, with common point changeover contact, 2 A maximum. - Control voltage : c or a 24...48 V, c 0...240 V, 0.85. Uc. - Maximum switching capacity : 250 VA or 50 W. - Operating temperature : -0 + 60 C. - Reset time :.5 s during the time delay period, 0.5 s after the time delay period. Clip-on front mounting, block per contactor Voltage Type Timing Composition Reference Weight range V s C/O kg LA2-KT2i c or a 24 48 On-delay 30 LA2-KT2E 0.040 c 0 240 On-delay 30 LA2-KT2U 0.040 Electronic time delay contact blocks LA2-KT On contactor LA2-KT 27 34 38 34 /6 Te
K 3 and 4-pole low consumption contactors, reversing and changeover contactors Mounting, marking and cabling accessories Mounting and marking accessories Description Application Sold in Reference Weight lots of kg Mounting For fixing Clip-on LA9-D973 0.025 plates () on ' rail For fixing 0/20 mm DX-AP25 0.065 on 2 ' rails fixing centres Marker Clip-on Onto front 00 LA9-D90 0.00 holder of contactor Clip-in 4 maximum Strips of 25 AB-Ri (2) 0.002 markers per contactor 0 identical numbers 0 9 DX-AP25 Strips of 25 AB-Gi (2) 0.002 0 identical capital letters A Z Cabling accessories Paralleling For 2 poles 4 LA9-E0 0.00 links with screw clamp terminals For 4 poles 2 LA9-E02 0.05 with screw clamp terminals Set of 6 power For 3-pole For contactors 00 LA9-K0969 0.00 connections reversing with screw contactors for clamp terminals motor control LA9-E0 Set of 4 power For 4-pole For contactors 00 LA9-K0970 0.00 connections changeover with screw contactor pairs clamp terminals () Order mounting plate for fixing a contactor and 2 mounting plates for fixing a reversing contactor. (2) Complete the reference by replacing the i with the required character. On one asymmetrical rail DZ5-MB with 2 clip-on mounting plates LA9-D973 or two mounting plates DX-AP25. 2 x LA9-D973 2 x DX-AP25 DZ5-ME5 50 5 20 0 2 = 35 = 90 5 On printed for reversing contactors or 2 contactors mounted side by side 8,65 === = = = 8,65 27 90 A A A2 A2 50 53 20xØ,3 Te /7