Mini contactors. K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. a.c. control contactors (1)

Similar documents
Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO

K-Line Mini - Contactors, Overload Relays and Accessories

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

TeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters

7 - Control relays. Control relays. b k control relays

TeSys D contactors. Selection guide. All types of control system. Rated operational voltage. Rated operational power in AC-3. Auxiliary contacts

TeSys contactors From 115 to 2750 A

IEC Type Industrial Control Relays Control Relays CA2D and CA3D AC and DC Relays

TeSys contactors. Pre-assembled. Pre-wired power connections. For connection by spring terminals. Instantaneous auxiliary contacts per contactor

DB eps. See page opposite for mounting possibilities according to the contactor type EN 5/78. Version : 20.0

3RA13, 3RA14 Contactor Assemblies

The technical guide TeSys D

Control relays and plug-in control relays

ontrol and rotection omponents

IEC Contactors. Auxiliary Contact Blocks GENERAL

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

Micro Contactor MA Series

sirius Switching. Protecting. Starting. SIRIUS Product Overview

Motor protection relays

Mini Contactors & Overloads

TeSys protection components

TeSys IEC Contactors and Overload Relays

Plug-in relays RH control relays Instantaneous (RHN) and latching (RHK)

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

3 Pole Contactors with AC operating coils

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

Contactors and Contactor Assemblies

Overload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview

IEC Power Control Contactors and Contactor Assemblies

Allen-Bradley Drives

Controls Contactors and Contactor Assemblies

ict contactors EN 61095, IEC 1095 Interference

Allen-Bradley 700-K40E-DJ

SIRIUS 3RB2 Solid-State Overload Relays

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

Zelio Relay - plug-in relays 6

Contactors and Contactor Assemblies

1 - Control and signalling units

Contactors and Contactor Assemblies

RUC industrial relays of small dimensions

40 Series - Miniature PCB/Plug-in relays A. 3.5 mm contact pin pitch 1 Pole 10 A PCB or 95 series sockets.

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

RUC industrial relays of small dimensions

RUC-M industrial relays for DC loads

Bulletin 817 Thermistor Protection Relay

Miniature PCB Relays A

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

Discover TeSys U motor starters open version Starter-controller Non-reversing power bases

SPM Series. Plug-in Surge Protection

EU Declaration of Conformity

3 - Interfaces. Contents 0. Interfaces for discrete signals. Selection guide... page 3/2. # Electromechanical interface modules...

NC2 Contactor, 115~630A. 1. General. 2. Type Designation. 3. Terminal Connection. Cabling(Cu) Cable 2. Tightening torque (N m) Screw size

TeSys SK, K, D. Technical Data for Designers. Contents

SPM Series Plug-in Surge Protection

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES

4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current

MODULES FOR SAFETY AND MONITORING

RW-E. Overloads. Solid-State Overload Relays. Standard Features

TeSys contactors 5. Selection 5. For utilisation category AC-3. Operational current and power conforming to IEC (θ y 60 C) Contactor size

RUC industrial relays of small dimensions

RPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED

Zelio Relay - plug-in relays

Circuit Breakers Type CTI 25M, CTI 45MB

Protection Equipment

Motor Control Products Selection Guide

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

CONTA-ELECTRONICS. Fuse, component, diode and indicator modules

TeSys protection components

Timers & control relays

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

Section 4 Ground-Fault Protection Devices

Solid-state relay (SSR) advantages. Solid-state relays

WMS SUPPLEMENTARY PROTECTORS

3RT, 3TB, 3TF Contactors for Switching Motors

RM4TA32 three-phase network control relay RM4-T - range V

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Power Electronics. Semiconductor relay / - contactor

Circuit Protectors CP31E, 32E, 33E, 34E CP31V, 32V, 33V, 34V

RM4TR31 three-phase network control relay RM4-T - range V

Protection components

Solid State Remote Power Controller E /627

New Solutions. for AC Motor Starters

Motor protection circuit breakers

Miniature Circuit-Breaker IEC Series 8562

Push buttons and selectors

Switchgear 1.1. CONTACTORS - Installation. Page 1.2. Page 1.2. CONTACTORS - Mini. Page POLE RELAY. Page 1.3. CONTACTORS - Standard Frame

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

RM84 miniature relays

Three-phase monitoring relay

Datasheet - SLB 200-C04-1R

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

CI-tronic Reversing contactor Type RCI

Universal Motor Controller UMC22-FBP. High-grade Motor Protection and Control

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

RM4JA01F current measurement relay RM4-J - range ma V AC

Transcription:

K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. c LC-K060ii a.c. control contactors () Standard power ratings Rated Type of Instantaneous Basic reference. Weight of 3-phase motors operational connection auxiliary Complete with code 50/60 Hz in category voltage contacts indicating control AC-3 in AC-3 circuit voltage (2) up to 220 V 380 V 440/500 V 400 V 230 V V 660/690 V kw kw kw A N/O N/C kg.5 2.2 3 6 Screw clamp LC-K060ii 0.80 LC-K060ii 0.80 Faston LC-K0607ii 0.80 x 6.35 LC-K0607ii 0.80 Solder pins LC-K0605ii 0.20 for printed LC-K0605ii 0.20 2.2 4 4 9 Screw clamp LC-K090ii 0.80 LC-K090ii 0.80 Faston LC-K0907ii 0.80 x 6.35 LC-K0907ii 0.80 Solder pins LC-K0905ii 0.20 for printed LC-K0905ii 0.20 a.c. control contactors for use in sensitive environments () Recommended for use in areas sensitive to noise, high interference mains supplies, etc. - Coil with rectifier incorporated, suppressor fitted as standard. - Screws in the open ready-to-tighten position..5 2.2 3 6 Screw clamp LC7-K060ii 0.225 LC7-K060ii 0.225 Faston LC7-K0607ii 0.225 x 6.35 LC7-K0607ii 0.225 Solder pins LC7-K0605ii 0.255 for printed LC7-K0605ii 0.255 2.2 4 4 9 Screw clamp LC7-K090ii 0.225 LC7-K090ii 0.225 Faston LC7-K0907ii 0.225 x 6.35 LC7-K0907ii 0.225 Solder pins LC7-K0905ii 0.255 for printed LC7-K0905ii 0.255 () Add-on auxiliary contact blocks and accessories, see pages /8 to /. (2) Standard control circuit voltages, see page opposite. Contactors LC-K, LC7-K, LP-K On panel LA-K 4xØ4 On mounting rail AM-DP200 or AM-DE200 (" 35 mm) 3 = 50 = = 35 = /2 Te

K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : d.c. a LP-K060ii d.c. control contactors () Standard power ratings Rated Type of Instantaneous Basic reference. Weight of 3-phase motors operational connection auxiliary Complete with code 50/60 Hz in category voltage contacts indicating control AC-3 in AC-3 circuit voltage (2) up to 220 V 380 V 440/500 V 400 V 230 V V 660/690 V kw kw kw A N/O N/C kg.5 2.2 3 6 Screw clamp LP-K060ii 0.225 LP-K060ii 0.225 Faston LP-K0607ii 0.225 x 6.35 LP-K0607ii 0.225 Solder pins LP-K0605ii 0.255 for printed LP-K0605ii 0.255 2.2 4 4 9 Screw clamp LP-K090ii 0.225 LP-K090ii 0.225 Faston LP-K0907ii 0.225 x 6.35 LP-K0907ii 0.225 Solder pins LP-K0905ii 0.255 for printed LP-K0905ii 0.255 () Add-on auxiliary contact blocks and accessories, see pages /8 to /. (2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Contactors LC-K (0.8.5 Uc) (0.85. Uc) Volts c 2 20 24 36 42 48 0 20 27 200/ 220/ 230 230/ 256 277 380/ 400 50/60 Hz 208 230 240 400 Code J7 Z7 B7 C7 D7 E7 F7 G7 FC7 L7 M7 P7 U7 W7 UE7 Q7 V7 Volts c 400/ 440 500 5 600 660/ 50/60 Hz 690 Code N7 R7 S7 SC7 X7 Y7 Up to and including 240 V, coil with integral suppression device available : add 2 to the code required. Example : J72 Contactors LC7-K (0.85. Uc) Volts c 24 42 48 0 220 230/ 50/60 Hz 240 Code B7 D7 E7 F7 M7 U7 Contactors LP-K (0.8.5 Uc) Volts a 2 20 24 36 48 60 72 00 0 25 55 74 200 220 230 240 250 Code JD ZD BD CD ED ND SD KD FD GD PD QD LD MD MPDMUD UD Coil with integral suppression device available : add 3 to the code required. Example : JD3 Contactors LC-K, LC7-K, LP-K On one asymmetrical rail DZ5-MB with clip-on mounting plate LA9-D973 DX-AP25 On printed DZ5-ME5 50 5 20 0 8,65 === 50 A 53 2 = 35 = 5 0xØ,3 A2 27 Te /3

Dimensions : pages /2 and /3 Mini contactors K 3 and 4-pole contactors for heating, lighting, etc., 20 A Utilisation category AC- Control circuit : a.c. and d.c. c a.c. control contactors () - Mounting on 35 mm " rail or Ø 4 mm screws. Non inductive Type of Number Instantaneous Basic reference. Weight loads connection of auxiliary Complete with code Category poles contacts indicating control AC- circuit voltage (2) Maximum current at θ 50 C A N/O N/C kg LC-K09004ii 20 Screw clamp 3 LC-K090ii 0.225 3 LC-K090ii 0.225 4 LC-K09004ii 0.80 2 2 LC-K09008ii 0.80 Faston 3 LC-K0907ii 0.225 x 6.35 3 LC-K0907ii 0.225 4 LC-K090047ii 0.80 2 2 LC-K090087ii 0.80 Solder pins 3 LC-K0905ii 0.255 for printed 3 LC-K0905ii 0.255 4 LC-K0900ii 0.20 2 2 LC-K090085ii 0.22 a.c. control contactors for use in sensitive environments () Recommended for use in areas sensitive to noise, high interference mains supplies, etc. - Coil with rectifier incorporated, suppressor fitted as standard. 20 Screw clamp 3 LC7-K090ii 0.225 3 LC7-K090ii 0.225 4 LC7-K09004ii 0.225 2 2 LC7-K09008ii 0.225 Faston 3 LC7-K0907ii 0.225 x 6.35 3 LC7-K0907ii 0.225 4 LC7-K090047ii 0.225 2 2 LC7-K090087ii 0.225 Solder pins 3 LC7-K0905ii 0.255 for printed 3 LC7-K0905ii 0.255 4 LC7-K0900ii 0.255 2 2 LC7-K090085ii 0.255 d.c. control contactors () 20 Screw clamp 3 LP-K090ii 0.225 3 LP-K090ii 0.225 4 LP-K09004ii 0.225 2 2 LP-K09008ii 0.225 Faston 3 LP-K0907ii 0.225 x 6.35 3 LP-K0907ii 0.225 4 LP-K090047ii 0.225 2 2 LP-K090087ii 0.225 Solder pins 3 LP-K0905ii 0.255 for printed 3 LP-K0905ii 0.255 4 LP-K0900ii 0.255 2 2 LP-K090085ii 0.255 () Add-on auxiliary contact blocks and accessories, see pages /8 to /. (2) Standard control circuit voltages, see page /3. /4 Te

Dimensions : page /6 Mini contactors K 3-pole reversing contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. and d.c. c a.c. control reversing contactors () LC2-K060ii - Integral mechanical interlock. - Pre-wired power circuit connections as standard on screw clamp versions. Standard power ratings Rated Type of Instantaneous Basic reference. Weight of 3-phase motors operational connection auxiliary Complete with code 50/60 Hz in category current contacts indicating control AC-3 in AC-3 circuit voltage (2) up to 220 V 380 V 440/500 V 400 V 230 V V 660/690 V kw kw kw A N/O N/C kg.5 2.2 3 6 Screw clamp LC2-K060ii 0.390 LC2-K060ii 0.390 Faston LC2-K0607ii 0.370 x 6.35 LC2-K0607ii 0.370 Solder pins LC2-K0605ii 0.430 for printed LC2-K0605ii 0.430 2.2 4 4 9 Screw clamp LC2-K090ii 0.390 LC2-K090ii 0.390 Faston LC2-K0907ii 0.370 x 6.35 LC2-K0907ii 0.370 Solder pins LC2-K0905ii 0.430 for printed LC2-K0905ii 0.430 a.c. control reversing contactors for use in sensitive environments () Recommended for use in areas sensitive to noise, high interference mains supplies, etc. - Coil with rectifier incorporated, suppressor fitted as standard. - Integral mechanical interlock. - Pre-wired power circuit connections as standard on screw clamp versions. - Mounting on " 35 mm rail or Ø 4 mm screw fixing..5 2.2 3 6 Screw clamp LC8-K060ii 0.480 LC8-K060ii 0.480 Faston LC8-K0607ii 0.460 x 6.35 LC8-K0607ii 0.460 Solder pins LC8-K0605ii 0.520 for printed LC8-K0605ii 0.520 2.2 4 4 9 Screw clamp LC8-K090ii 0.480 LC8-K090ii 0.480 Faston LC8-K0907ii 0.460 x 6.35 LC8-K0907ii 0.460 Solder pins LC8-K0905ii 0.520 for printed LC8-K0905ii 0.520 d.c. control reversing contactors ().5 2.2 3 6 Screw clamp LP2-K060ii 0.480 LP2-K060ii 0.480 Faston LP2-K0607ii 0.460 x 6.35 LP2-K0607ii 0.460 Solder pins LP2-K0605ii 0.520 for printed LP2-K0605ii 0.520 2.2 4 4 9 Screw clamp LP2-K090ii 0.480 LP2-K090ii 0.480 Faston LP2-K0907ii 0.460 x 6.35 LP2-K0907ii 0.460 Solder pins LP2-K0905ii 0.520 for printed LP2-K0905ii 0.520 () Auxiliary contact blocks and accessories, see pages /8 to /. (2) Control circuit voltage codes, see page /7. Te /5

K 3 and 4-pole changeover contactors for heating, lighting, etc., 20 A Utilisation category AC- Control circuit : a.c. c a.c. control reversing contactors () - Integral mechanical interlock. Non inductive Type of Number Instantaneous Basic reference. Weight loads connection of auxiliary Complete with code Category poles contacts indicating control AC- circuit voltage (2) Maximum current at θ 50 C A N/O N/C kg 20 Screw clamp 3 LC2-K090ii (3) 0.390 3 LC2-K090ii (3) 0.390 4 LC2-K09004ii 0.380 Faston 3 LC2-K0907ii 0.370 x 6.35 3 LC2-K0907ii 0.370 4 LC2-K090047ii 0.370 LC2-K090ii Solder pins 3 LC2-K0905ii 0.430 for printed 3 LC2-K0905ii 0.430 4 LC2-K0900ii 0.430 a.c. control reversing contactors for use in sensitive environments () Recommended for use in areas sensitive to noise, high interference mains supplies, etc. - Coil with rectifier incorporated, suppressor fitted as standard. - Integral mechanical interlock. - Mounting on " 35 mm rail or Ø 4 mm screw fixing. 20 Screw clamp 3 LC8-K090ii (3) 0.480 3 LC8-K090ii (3) 0.480 4 LC8-K09004ii 0.470 Faston 3 LC8-K0907ii 0.460 x 6.35 3 LC8-K0907ii 0.460 4 LC8-K090047ii 0.460 Solder pins 3 LC8-K0905ii 0.520 for printed 3 LC8-K0905ii 0.520 4 LC8-K0900ii 0.520 () Add-on auxiliary contact blocks and accessories, see pages /8 to /. (2) Control circuit voltage codes, see page opposite. (3) Warning: this reversing contactor is pre-wired for reverse motor operation as standard. Reversing contactors LC2-K, LC8-K, LP2-K On panel LA-K 8xØ4 On mounting rail AM-DP200 or AM-DE200 ( " 35 mm) 3 90 = 50 = = 80 = 90 /6 Te

K 3 and 4-pole changeover contactors for heating, lighting, etc., 20 A Utilisation category AC- Control circuit : d.c. a LP2-K090ii d.c. control reversing contactors () - Integral mechanical interlock. Non inductive Type of Number Instantaneous Basic reference. Weight loads connection of auxiliary Complete with code Category poles contacts indicating control AC- circuit voltage (2) Maximum current at θ 50 C A N/O N/C kg 20 Screw clamp 3 LP2-K090ii (3) 0.480 3 LP2-K0900ii (3) 0.480 4 LP2-K09004ii 0.480 Faston 3 LP2-K0907ii 0.460 x 6.35 3 LP2-K0907ii 0.460 4 LP2-K090047ii 0.460 Solder pins 3 LP2-K0905ii 0.520 for printed 3 LP2-K0905ii 0.520 4 LP2-K0900ii 0.520 () Add-on auxiliary contact blocks and accessories, see pages /8 to /. (2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Reversing contactors LC2-K (0.8.5 Uc) (0.85. Uc) Volts c 2 20 24 36 42 48 0 20 27 200/ 220/ 230 230/ 256 277 380/ 400 50/60 Hz 208 230 240 400 Code J7 Z7 B7 C7 D7 E7 F7 G7 FC7 L7 M7 P7 U7 W7 UE7 Q7 V7 Volts c 400/ 440 500 5 600 660/ 50/60 Hz 690 Code N7 R7 S7 SC7 X7 Y7 Up to and including 240 V, coil with integral suppression device available : add 2 to the code required. Example : J72 Reversing contactors LC8-K (0.85. Uc) Volts c 24 42 48 0 220 230/ 50/60 Hz 240 Code B7 D7 E7 F7 M7 U7 Reversing contactors LP2-K (0.8.5 Uc) Volts a 2 20 24 36 48 60 72 00 0 25 55 74 200 220 230 240 250 Code JD ZD BD CD ED ND SD KD FD GD PD QD LD MD MPD MUD UD Coil with integral suppression device available : add 3 to the code required. Example : JD3 (3) Warning: this reversing contactor is pre-wired for reverse motor operation as standard. On one asymmetrical rail DZ5-MB with 2 clip-on mounting plates LA9-D973 or on 2 mounting plates DX-AP25. 2 x LA9-D973 2 x DX-AP25 DZ5-ME5 50 5 20 0 2 = 35 = 90 5 On printed for reversing contactors or 2 contactors mounted side by side 27 90 8,65 === = = = 8,65 A A A2 A2 50 53 20xØ,3 Te /7

LC,LC7,LP-K06,K09 LA-KN LA-KN M LC,LC7,LP-K06,K09 LA-KN LA2-KT2 LC,LC7,LP-K09 LA-KN P /8 Te

K 3 and 4-pole contactors, reversing and changeover contactors Instantaneous and time delay auxiliary contacts Illustrations : page /8 Instantaneous auxiliary contact blocks Recommended for standard applications Clip-on front mounting, block per contactor Type of connection Type of contactor Composition Reference Weight LA-KN40ii ii N/O N/C kg Screw clamp LC, LC7, LP 2 LA-KN20 0.0 3 or 4-pole 2 LA-KN02 () 0.0 LA-KN (2) 0.0 4 LA-KN40 0.0 3 LA-KN3 0.0 2 2 LA-KN22 0.0 3 LA-KN3 (3) 0.0 4 LA-KN04 (4) 0.0 Faston LC, LC7, LP 2 LA-KN207 0.0 x 6.35 3 or 4-pole 2 LA-KN027 0.0 LA-KN7 0.0 4 LA-KN407 0.0 3 LA-KN37 0.0 2 2 LA-KN227 0.0 3 LA-KN37 0.0 4 LA-KN047 0.0 With terminal referencing conforming to standard EN 5002 Clip-on front mounting, block per contactor Screw clamp LC, LC7, LP 2 LA-KN02M 0.0 3-pole LA-KNM 0.0 6 and 9 A 3 LA-KN3M 0.0 2 2 LA-KN22M 0.0 3 LA-KN3M 0.0 LC, LC7, LP LA-KNP 0.0 4-pole 2 2 LA-KN22P 0.0 9 A () Cannot be used on contactors : LP4/LP5-Kii0, LP4/LP5-K09008. (2) Cannot be used on contactors : LP4/LP5-K09008. (3) Cannot be used on contactors : LC7/LC8/LP/LP2-K09008. (4) Cannot be used on contactors : LC7/LC8/LP/LP2-Kii0, LC7/LC8/LP/LP2-K09008. Electronic time delay auxiliary contact blocks - Relay output, with common point changeover contact, 2 A maximum. - Control voltage : c or a 24 48 V, c 0 240 V, 0.85. Uc. - Maximum switching capacity : 250 VA or 50 W. - Operating temperature : -0 + 60 C. - Reset time :.5 s during the time delay period, 0.5 s after the time delay period. Clip-on front mounting, block per contactor Voltage Type Timing Composition Reference Weight range V s C/O kg c or a 24 48 On-delay 30 LA2-KT2E 0.040 c 0 240 On-delay 30 LA2-KT2U 0.040 Electronic time delay contact blocks LA2-KT On contactors On reversing contactors LA2-KT LA2-KT 27 34 38 34 34 Te /9

K 3 and 4-pole contactors, reversing and changeover contactors Suppressor modules incorporating LED indicator Mounting Type For voltages: Sold in Unit Weight and connection lots of reference kg Clip-on fixing Varistor c and a 5 LA4-KEB 0.00 on the front of () 2 24 V contactors LC, LC2, LP and LP2 c and a 5 LA4-KEE 0.00 32 48 V LA4-Kiii c and a 5 LA4-KEFC 0.00 50 29 V c and a 5 LA4-KEUG 0.00 30 250 V Diode + a 5 LA4-KCB 0.00 Zener diode (2) 2 24 V a 5 LA4-KCE 0.00 32 48 V RC (3) c 5 LA4-KAU 0.00 220 250 V () Protection by limitation of the transient voltage up to 2 Uc maximum. Maximum reduction of transient voltage peaks. Slight time delay on drop-out (. to.5 times the normal time). (2) No overvoltage or oscillation frequency. Polarised component. Slight time delay on drop-out (. to.5 times the normal time). (3) Protection by limitation of the transient voltage up to 3 Uc maximum and limitation of the oscillation frequency. Slight time delay on drop-out (.2 to 2 times the normal time). Suppressor modules LA4-Ki On contactors On reversing contactors 25 22 6 22 22 /0 Te

K 3 and 4-pole contactors, reversing and changeover contactors Accessories Dimensions : pages /3 and /7 Mounting and marking accessories Description Application Sold in Unit Weight lots of reference kg Mounting For fixing Clip-on LA9-D973 0.025 plates () on ' rail For fixing 0/20 mm DX-AP25 0.065 on 2 ' rails fixing centres Marker Clip-on Onto front of 00 LA9-D90 0.00 holder contactor Clip-in 4 maximum Strips of 25 AB-Ri (2) 0.002 markers per contactor 0 identical numbers 0 9 Strips of 25 AB-Gi (2) 0.002 0 identical capital letters A Z Cabling accessories Description Application Sold in Unit Weight lots of reference kg Paralleling For 2 poles 4 LA9-E0 0.00 links with screw clamp terminals For 4 poles 2 LA9-E02 0.05 with screw clamp terminals Set of 6 power For 3-pole For contactors 00 LA9-K0969 0.00 connections reversing with screw contactors for clamp terminals motor control Set of 4 power For 4-pole For contactors 00 LA9-K0970 0.00 connections changeover with screw contactor clamp terminals pairs () Order mounting plate for fixing a contactor and 2 mounting plates for fixing a reversing contactor. (2) Complete the reference by replacing the i with the required character. Te /

Mini thermal overload relays K thermal overload relays, adjustable from 0. to.5 A, for motor protection; compensated and phase failure sensitive, manual or automatic reset 3-pole relays with screw clamp terminals Direct mounting : under the contactor for versions with screw clamp terminals only; pre-wired terminals, see below. Separate mounting : using terminal block LA7-K0064 (see below). On the front of the overload relay : - selection of reset mode : Manual (marked H) or Automatic (marked A), - red pushbutton : Trip Test function, - red pushbutton : Trip reset, - blue pushbutton : Stop and manual Reset, - yellow trip flag indicator : overload relay tripped. Protection by fuses or by magnetic circuit-breaker type GV2-L, see page /92. Relay Fuses to be used with selected relay Reference Weight setting Maximum rating range Type am gg (BS88) A A A kg Class 0 A (the standard specifies a tripping time of between 2 and 0 seconds at 7.2 In) 0. 0.6 0.25 2 LR2-K030 0. LR2-K030 0.6 0.23 0.25 2 LR2-K0302 0. 0.23 0.36 0.5 2 LR2-K0303 0. 0.36 0.54 4 LR2-K0304 0. 0.54 0.8 4 LR2-K0305 0. 0.8.2 2 6 LR2-K0306 0..2.8 2 6 LR2-K0307 0..8 2.6 4 0 LR2-K0308 0. 2.6 3.7 4 6 LR2-K030 0. 3.7 5.5 6 6 LR2-K032 0. 5.5 8 8 20 LR2-K034 0. 8.5 0 20 LR2-K036 0. LR2-K Direct mounting under the contactor 8 = 50 = = 35 = 4xØ4 6 65 /2 Te

Mini thermal overload relays K thermal overload relays, adjustable from 0. to.5 A, for motor protection; compensated and phase failure sensitive, manual or automatic reset Accessories for thermal overload relays Description Type of connection Reference Weight kg Terminal block for separate Screw clamp LA7-K0064 0.00 clip-on mounting of the overload relay on 35 mm " rail Separate mounting with terminal block LA7-K0064 on 35 mm " rail (AM-DP200 or AM-DE200) 80 38 75 c AM- C DP200 78.5 DE200 86 Te /3

K 3 and 4-pole low consumption contactors for motor control (AC-3) and heating and lighting, etc. (AC-) Control circuit : d.c. a d.c. control contactors () - Compatible with programmable controller outputs. - LED indicator incorporated. - Wide range coil (0.7.30 Uc), suppressor fitted as standard, consumption.5 W. Motor control Type of Instantaneous Basic reference. Weight in category AC-3 connection auxiliary Complete with code Maximum Standard contacts indicating control opera- power ratings circuit voltage (2) tional of 3-phase current motors 440 V 220 V 380 V 440/500 V 230 V V 660/690 V A kw kw kw N/O N/C kg LP4-K060 6.5 2.2 3 Screw clamp LP4-K060iii 0.235 LP4-K060iii 0.235 Faston x 6.35 LP4-K0607iii 0.235 LP4-K0607iii 0.235 Solder pins LP4-K0605iii 0.265 for printed LP4-K0605iii 0.265 9 2.2 4 4 Screw clamp LP4-K090iii 0.235 LP4-K090iii 0.235 Faston x 6.35 LP4-K0907iii 0.235 LP4-K0907iii 0.235 Solder pins LP4-K0905iii 0.265 for printed LP4-K0905iii 0.265 Non Type of Number Instantaneous Basic reference. Weight inductive connection of auxiliary Complete with code loads poles contacts indicating control Cat. AC- circuit voltage (2) θ 50 C Maximum current A N/O N/C kg 20 Screw clamp 3 LP4-K090iii 0.235 3 LP4-K090iii 0.235 4 LP4-K09004iii 0.235 2 2 LP4-K09008iii 0.235 Faston x 6.35 3 LP4-K0907iii 0.235 3 LP4-K0907iii 0.235 4 LP4-K090047iii 0.235 2 2 LP4-K090087iii 0.235 Solder pins 3 LP4-K0905iii 0.265 for printed 3 LP4-K0905iii 0.265 4 LP4-K0900iii 0.265 2 2 LP4-K090085iii 0.265 () Add-on auxiliary contact blocks and accessories, see pages /6 and /7. (2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Volts a 2 24 48 72 Code JW3 BW3 EW3 SW3 Contactors LP4-K On panel LA-K 3 /4 Te = 50 = 4xØ4 = 35 = On mounting rail AM-DP200 or AM-DE200 (" 35 mm)

K 3 and 4-pole low consumption reversing and changeover contactors for motor control (AC-3) and heating, lighting etc., (AC-) Control circuit : d.c. a d.c. control reversing and changeover contactors () - Compatible with programmable controller outputs. - LED indicator incorporated. - Wide range coil (0.7.30 Uc), suppressor fitted as standard, consumption.5 W. - Mechanical interlock incorporated. - Pre-wired power circuit connections as standard on screw clamp versions. Motor control Type of Instantaneous Basic reference. Weight in category AC-3 connection auxiliary Complete with code Maximum Standard contacts indicating control opera- power ratings circuit voltage (2) tional of 3-phase current motors 440 V 220 V 380 V 440/500 V 230 V V 660/690 V A kw kw kw N/O N/C kg 6.5 2.2 3 Screw clamp LP5-K060iii 0.490 LP5-K060iii 0.490 Faston x 6.35 LP5-K0607iii 0.470 LP5-K0607iii 0.470 Solder pins LP5-K0605iii 0.530 for printed LP5-K0605iii 0.530 9 2.2 4 4 Screw clamp LP5-K090iii 0.490 LP5-K090iii 0.490 Faston x 6.35 LP5-K0907iii 0.470 LP5-K0907iii 0.470 Solder pins LP5-K0905iii 0.530 for printed LP5-K0905iii 0.530 LP5-K090iii Non Type of Number Instantaneous Basic reference. Weight inductive connection of auxiliary Complete with code loads poles contacts indicating control Cat. AC- circuit voltage (2) θ 50 C Maximum current Reversing contactors LP5-K On panel LA-K 8xØ4 A N/O N/C kg 20 Screw clamp 3 LP5-K090iii (3) 0.490 3 LP5-K090iii (3) 0.490 4 LP5-K09004iii 0.490 Faston x 6.35 3 LP5-K0907iii 0.470 3 LP5-K0907iii 0.470 4 LP5-K090047iii 0.470 Solder pins 3 LP5-K0905iii 0.530 for printed 3 LP5-K0905iii 0.530 4 LP5-K0900iii 0.530 () Add-on auxiliary contact blocks and accessories, see pages /6 and /7. (2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Volts a 2 24 48 72 Code JW3 BW3 EW3 SW3 (3) Warning: this reversing contactor is pre-wired for reverse motor operation. On mounting rail AM-DP200 or AM-DE200 (" 35 mm) 3 = 80 90 = = 50 = 90 Te /5

K 3 and 4-pole low consumption contactors, reversing and changeover contactors Instantaneous and time delay auxiliary contacts Instantaneous auxiliary contact blocks Clip-on front mounting, block per contactor Type of Type of Composition Reference Weight connection contactor N/O N/C kg Screw clamp 3 or 4-pole 2 LA-KN20 0.0 2 LA-KN02 0.0 LA-KN 0.0 Faston 3 or 4-pole 2 LA-KN207 0.0 x 6.35 2 LA-KN027 0.0 LA-KN7 0.0 With terminal referencing conforming to standard EN 5002 Clip-on front mounting, block per contactor Screw clamp 3-pole, 2 LA-KN02M 0.0 6 and 9 A LA-KNM 0.0 4-pole, 9 A LA-KNP 0.0 Electronic time delay auxiliary contact blocks - Relay output, with common point changeover contact, 2 A maximum. - Control voltage : c or a 24...48 V, c 0...240 V, 0.85. Uc. - Maximum switching capacity : 250 VA or 50 W. - Operating temperature : -0 + 60 C. - Reset time :.5 s during the time delay period, 0.5 s after the time delay period. Clip-on front mounting, block per contactor Voltage Type Timing Composition Reference Weight range V s C/O kg LA2-KT2i c or a 24 48 On-delay 30 LA2-KT2E 0.040 c 0 240 On-delay 30 LA2-KT2U 0.040 Electronic time delay contact blocks LA2-KT On contactor LA2-KT 27 34 38 34 /6 Te

K 3 and 4-pole low consumption contactors, reversing and changeover contactors Mounting, marking and cabling accessories Mounting and marking accessories Description Application Sold in Reference Weight lots of kg Mounting For fixing Clip-on LA9-D973 0.025 plates () on ' rail For fixing 0/20 mm DX-AP25 0.065 on 2 ' rails fixing centres Marker Clip-on Onto front 00 LA9-D90 0.00 holder of contactor Clip-in 4 maximum Strips of 25 AB-Ri (2) 0.002 markers per contactor 0 identical numbers 0 9 DX-AP25 Strips of 25 AB-Gi (2) 0.002 0 identical capital letters A Z Cabling accessories Paralleling For 2 poles 4 LA9-E0 0.00 links with screw clamp terminals For 4 poles 2 LA9-E02 0.05 with screw clamp terminals Set of 6 power For 3-pole For contactors 00 LA9-K0969 0.00 connections reversing with screw contactors for clamp terminals motor control LA9-E0 Set of 4 power For 4-pole For contactors 00 LA9-K0970 0.00 connections changeover with screw contactor pairs clamp terminals () Order mounting plate for fixing a contactor and 2 mounting plates for fixing a reversing contactor. (2) Complete the reference by replacing the i with the required character. On one asymmetrical rail DZ5-MB with 2 clip-on mounting plates LA9-D973 or two mounting plates DX-AP25. 2 x LA9-D973 2 x DX-AP25 DZ5-ME5 50 5 20 0 2 = 35 = 90 5 On printed for reversing contactors or 2 contactors mounted side by side 8,65 === = = = 8,65 27 90 A A A2 A2 50 53 20xØ,3 Te /7