SINAR TECHNOLOGY MOISTURE PROBE USER MANUAL.

Similar documents
SINAR TECHNOLOGY LARGE SEED MOISTURE SAMPLER. USER MANUAL

Sinar Model 6060 AP Moisture Analyzer. Users Manual

Sinar large seed Moisture Analyser

Sinar Model 6060 AP Moisture Analyzer. Users Manual

User manual. paper moisture meter humimeter RH5 with sword sensor

CONGRATULATIONS ON YOUR CHOICE

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

SINAR TECHNOLOGY MOISTURE ANALYZER SUPPORT DOCUMENT

User Manual. Dual-Input Data Logging Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

PTR. printing temperature recorder. User Manual. order code:

mini gac and mini gac


Instant Moisture Meter for Grains, Seeds, Coffee and other small products PM-650. Operating Manual

OPERATION MANUAL. Pen type, air oxygen and Temp. O2 METER. Model : PO2-250

Hand-Held Thermometer Model CTH 6200

RH/Temperature SD Card Datalogger. Instruction Manual

Sartorius XQ 6100, XQ 6100 B.

Hand-held thermometer Model CTH7000

DTM-321 REL HOLD T2 K-TYPE TEMP: 20 C 60 C 140 F C F HUMIDITY: %RH POWER-UP OPTIONS

WEB SITE:

Model SRV411i Small Animal Floor Scale Service Manual Part No. MANSRV411i_ Page 1 of 16. Small Animal Floor Scale. Operating and Service Manual

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

Microprocessor Benchtop Conductivity/ Resistivity Meter SC Operation Manual

Oxford E Series. Instruction Manual

1366 INSTRUCTION MANUAL

Model SR411i-KG Patient Floor Scale Service Manual Part No. MAN411i-KG_ Page 1 of 16. Patient Floor Scale. Operating and Service Manual

MODEL 3150 SUSPENDED SOLIDS ANALYZER MODEL 35/35L OPTICAL SUSPENDED SOLIDS SENSOR

SIGMATEST Operating Instructions

Electronic Oil Meter OM 20

Hand-held thermometer Model CTH6200

MI-4 Melt Flow Indexer

Humidity + Temp. + Dew Point Pocket size HUMIDITY METER. Model : HT-315

HUMLOG 10. Manual. Status V4 (02/2010)

Microprocessor ph/orp Controller

BetaProbe TI/TI+ High Accuracy Digital Thermometer. User Reference Manual

MI-3 Melt Flow Indexer

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION

Hand-held thermometer Model CTH7000

Type K/J Thermometers

DC resistance thermometry bridge Model CTR6000

1. Introduction 2. Specifications 3. Symbol Definition and Button Location 4. Operation Instructions 5. Temperature Measurement 6.

Portable pressure calibrator Model CPH7600

ASM Series. Advanced Signal Multi-scanner. Functional signal multi-scanner adding flexibility to your calibration needs

Hand-held thermometer Model CTH6200

OPERATING MANUAL. EchoThermJ PROGRAMMABLE, DIGITAL, ELECTRONIC CHILLING/HEATING PLATE MODEL IC25, IC25XR, IC25XT, IC35 and IC35XT

GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual

Introduction... 1 Features... 1 Specifications... 2 Storage... 2 Battery... 3 Switchpad Functions... 3

Instruction Manual. 24" and 48" Waterproof Electronic Digital Level Model Nos &

Field Metrology Wells

Multi-functional precision thermometer CTR3000

GRUNDFOS ALLDOS DATA BOOKLET. Conex DIS-C. Measuring amplifiers and controllers for conductivity measurement 50/60 Hz

KW serial. User s guide. Bench Scales UGKW-E0302

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website:

ES-600 Ozone Controller Operation Manual

MODEL 3150 SUSPENDED SOLIDS ANALYZER MODEL 35/35L OPTICAL SUSPENDED SOLIDS SENSOR

Visible Light SD Card Datalogger

OPERATION MANUAL. Carbon monoxide 0 to 1000 PPM, Temp. CO METER. Model : GCO-2008

Manual Digital Thermometer PCE-T 390

Next Generation! We measure it. With the professional Testo data loggers, a new age begins for you. Logger series testo 174. Logger series testo 175

MOISTURE METER OPERATION MANUAL. all in one. Model : PMS-713

Precision thermometer Model CTR5000

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website:

USER MANUAL AD 3000 EC/TDS/Temperature Bench Meter

Humidity/Temperature Dataloggers

DICKSON FH320/325 & FT300/325 DICKSON. Temperature/Humidity Recorder. Specifications. Applications & Product. Product. Contents: Getting Started

INSTRUCTION MANUAL CONDUCTIVITY-METER MODEL CC-01

IDS-801 Series Compact Bench Counting Scale. User Manual

GE Sensing. Grainmaster i Protimeter Grain Moisture Meter. Instruction Manual

Portable Temperature Calibrator QUARTZ Dry Block Calibrator -50 C C

DRAFT. Customer site gravity factor. Filtering parameters. Five points for linearity correction to ensure maximum accuracy

Paint Test Equipment. Data Sheet / Instructions. Gloss Meter

The ultimate microwave moisture measurement systems for concrete and asphalt batch plants. Product range THE ORIGINAL THE LEADERS THE BEST

AC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

SOUND LEVEL METER DVM1351 INSTRUCTION MANUAL HANDLEIDING MANUEL D UTILISATEUR DVM1351 SOUND LEVEL METER 1

rht+ RHTPlus CalComm Calibration Unit with Analogue Outputs

Instruction Manual. 24" and 48" Electronic Digital Level Model Nos &

User Manual. CV-401 / 801 / U Rackmount PS/2 KVM Switch

DPM-3221 Digital DC Power Meter with data logging capability.

Precision thermometer Model CTR2000

testostor 171 Instruction manual

Next Generation! We measure it. With the professional Testo data loggers, a new age begins for you. Logger series testo 174. Logger series testo 175

7561-PSD Manual Portable Battery Powered Indicator

Colorado Series. CR-10 Portable ph / mv / Temperature Meter Operation Manual

Ultralow temperature freezers -86 C. Platilab & Irilab Series

Advanced Test Equipment Rentals ATEC (2832)

Platinum RTD Thermometer MODEL NO

CONTENTS Introduction 4 DTR overview 4 probes 5 functions 5 display 5 DTR operation 6 switching the DTR on or off 6 changing label 6 displaying

PH SD Card Datalogger. Instruction Manual

EVt and N2000 Series Dataloggers. EVSW Software Quick Start Guide

grain moisture analyser FSA

Press the PEN HOME key to move the pen(s) to the outside of the chart. The pen(s) is automatically raised off the chart.

CALOG CALOG - LC DISPLAY. Loadcell Display. English Users Manual. Rev. 1.10

600 g x 0.02 g DIGITAL BALANCE

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com DPI 820. Dual Input Thermometer. User manual.

Model 6815 HYGRO-THERMOMETER ANEMOMETER. User Manual. Kanomax USA, Inc. 219 Route 206 PO Box 372. Andover, NJ USA

Platinum RTD Thermometer MODEL NO

Barnant Company. Humidity Data Logger MODEL NO YR MIN HOLD MO MAX DAY STORE LOG RECALL PRINT C/ F PRINT SETUP.

GB/UK. Operating manual. Data logger EBI USB

CODUCTIVITY METER OPERATION MANUAL. Model : CD-4303

OPERATIONAL MANUAL FOR 85XX

Transcription:

SINAR TECHNOLOGY MOISTURE PROBE USER MANUAL. Read all instructions prior to operating your Sinar Moisture Probe. Whenever using this unit, remember to follow the appropriate operating procedures. For your reference/record: Serial Number: Purchase Date: Date Registration Card Mailed: Moisture Probe. Rev. 3. 11/10 For Version 1.2 software. Sinar Technology Unit 5, Camberley Business Centre, Bracebridge, Camberley, Surrey. GU15 3DP ENGLAND Tel: 0844 745 1999 Tel International: +44 208 328 0727 Fax: +44 (0) 1276-29941 Email: office@sinar.co.uk Website: www.sinar.co.uk

2 Sinar Moisture Probe. Model 6600 The performance of this Moisture Analyser is dependent on the correct use and instrument care by the customer. It is important to check the calibration (both commodity and hardware) periodically and, if necessary, make adjustments following the procedure in this manual. The commodity calibration can be checked by comparing the Moisture Analyser results against reference samples, e.g. oven tested samples (please ensure that tested samples are based on the correct oven test specification). CONTENTS

3 1.0 INTRODUCTION. 4 2.0 BASIC PRINCIPLE OF OPERATION 4 3.0 OPERATING INSTRUCTIONS 5 3.1 Taking a single moisture content reading. 5 3.2 Taking continuous moisture content readings. 5 3.3 Measuring sample temperature. 6 3.4 Using the average moisture content facility. 6 4.0 CALIBRATION ADJUSTMENTS. 7 4.1 % moisture content. 7 5.0 CALIBRATION TRANSFERS. 10 5.1 Remote access mode. 10 5.2 Continuous mode. 10 5.2.1 Single curve transfer. 10 5.2.2 CURVE SET TRANSFER. 13 6.0 HARDWARE SECTION. 14 6.1 Checking hardware calibrations. 14 6.2 Resetting hardware. 14 7.0 CHANGING DEFAULT SETTINGS. 16 8.0 TECHNICAL SPECIFICATION. 19 8.1 Display unit. 19 8.2 Sensor. 19 9.0 SINAR MOISTURE PROBE ACCESSORIES. 20

1.0 INTRODUCTION. 4 The Sinar Moisture Probe, moisture Analyser houses the latest moisture measuring technology in a compact package. It has been designed to provide fast moisture results using whole grain samples. In addition to % moisture content, the Moisture Probe also measures temperature. Each instrument is pre-calibrated for up to seven commodities either chosen from a standard package of programmes or selected from the Sinar calibration library. The calibration of any product can be optimised using a bias facility. The Sinar Moisture Probe is one of a family of moisture analysers. All models have the facility to transfer and receive calibrations either from each other, via a Sinar Acoustic Coupler and telephone link or via the Internet. Similarly new commodities can be transferred or existing calibrations can be updated with new information. The Sinar Moisture Probe has been calibrated using clean samples. Accuracy can be affected by the presence of stones, dirt, weeds, seeds, admixture, chaff or other foreign matter. Clean the sensor with a soft brush to prevent material build-up on the fins. NEVER USE WATER. Take care not to damage the temperature sensor. 2.0 BASIC PRINCIPLE OF OPERATION The design concept of the Sinar Moisture Probe is based on the simultaneous sensing of capacitance and temperature of the sample being tested, providing a corrected moisture (%) reading in a few seconds. It works accurately on products with a moisture content ranging from approximately 1% to 35% depending on the application. The instrument incorporates 2 sensors: 1. Capacitance The moisture in a sample absorbs the electrical energy between the sensor fins. The electrical signal known as "Capacitance" increases with the moisture content of the sample. 2. Temperature Correction The capacitance of a sample increases with temperature. A temperature sensing thermistor is mounted in the sample cell and the microprocessor carries out an automatic correction. Sinar refer to a capacitance reading corrected for temperature as a code 0 reading.

3.0 OPERATING INSTRUCTIONS 5 Hold the display unit in one hand. Hold the spear via the black mushroom cap in the other hand. Select the required crop as detailed below. Insert the spear sensor into the crop ensuring that the black sensor fins are completely covered. We recommend the sensor is inserted to a consistent depth to give a consistent packing density of crop around the sensor. Proceed as detailed below. 3.1 Taking a single moisture content reading. Switch on I - HI - Select channel 1-7 e.g. 2. 2 %H 2 0 Moisture content will be displayed after 5 seconds. 14.5 3.2 Taking continuous moisture content readings. Switch on I - HI - Select channel 1-7 e.g. 2. 2 and hold %H 2 0 LOG

6 After approx. 5 seconds the unit will display a moisture reading. The reading is updated every 4 seconds. 14.5 To end continuous mode, proceed as follows:- and hold %H 2 0 -LOG 3.3 Measuring sample temperature. TEMP Sample temperature can be measured by pressing the button when the sample is covering the sensor. If the sample temperature is very different from the ambient temperature, leave the sample for 30 seconds before you press TEMP. Alternatively, keep on pressing the TEMP button, until a stable temperature is displayed. TEMP 21.0 3.4 Using the average moisture content facility. A maximum of 254 samples can be averaged. It the AVER button is held down, the display will show the number of measurements that have been made, e.g. and hold 3 AVER

7 When this key is released, the average % moisture content will be displayed, e.g. 10.6 The average can be reset to zero by switching the analyser off and on or by changing channels. NOTE. If using the average function ensure the sensor is always covered with sample. If a reading is taken with the sensor half covered, the reading will added to the average stack and effect the accuracy of the final result. 4.0 CALIBRATION ADJUSTMENTS. 4.1 % moisture content. Sometimes it is useful to be able to adjust the moisture reading, for instance, when a different oven test is used, or when the particle size of a product is significantly different, or when 2 instruments are checked against each other. However, before adjusting the moisture reading, check that the hardware settings are correct. (Section. 6.1). Having done this surround the sensor with sample and select the appropriate calibration channel. The moisture reading may be adjusted for each individual channel using the up and down arrow keys. The adjustment applies to all points of the selected channel. Determine the average adjustment needed by comparing at least 3 different samples.

8 Switch on I - HI - and hold CAL AUTO CAL. Enter password and press P P Note: The Analyser gives an audible alarm if the wrong password is entered. %H 2 0 10.9 After 5 seconds the moisture result is displayed. If the average adjustment needed is +0.3%, press up arrow times so that the display reads: key three and hold lb/bu kg/hl 11.2 button, this displays the channel number that has been adjusted. Release the key and the display will show the adjustment that has been made. Note: When the instrument leaves the factory the password is 123.

9 In order to check to see whether a channel has been adjusted, proceed as follows: Switch on I - HI - and hold CAL AUTO CAL. Select channel, e.g. 1. 1 lb/bu kg/hl 0.0 (0.0 means that no adjustment has been made).

5.0 CALIBRATION TRANSFERS. 10 5.1 Remote access mode. The Moisture Probe can be put into remote access mode or PLUG mode. This is a remote mode to enable calibration data to be imported or exported from the Moisture Probe to a PC with the Sinar MNET (Pt No 1900-6309) software installed. Data can also be transmitted via telephone line using the Sinar Acoustic Coupler (Pt No 6230-001). and hold the TEMP button while switching on I - - - - PLUg - HI - All operations are now carried out via the PC. 5.2 Continuous mode. The following instructions relate to communicating with a Sinar AP moisture instrument only. Details of communications with other models are included in their respective user manuals. 5.2.1 Single curve transfer. In order to transfer one calibration to an AP analyser, proceed as follows: Ensure both units are switched off. Connect the Sinar calibration transfer cable (Pt No 1000-2766) to the RS232 port on the left hand side of the Moisture Analysers.

11 Switch on both instruments. - HI - For both instruments: Hold down CAL AUTO CAL. Enter password and press P P CAL AUTO COPA By this stage both instruments should be displaying COPA. (This is known as the communication mode). On the Sending Unit. channel number, e.g. 1, this contains the calibration curve to be transferred to the other analyser. 1 %H 2 0 OUT Display Shows.

12 On receiving unit. 1 channel number, e.g. 7 in which new calibration is to be installed. 7 AVER IN On the sending unit. 1 On the receiving unit. 7 After 6 seconds both units will display PASS The transfer is now complete. Switch off both units and remove cable.

5.2.2 Curve set transfer. 13 Set both units to display. COPA On the sending unit press On the receiving unit press %H 2 0 AVER OUT IN Sending unit changes to - OUT Receiving unit changes to - IN When the transfer is completed both instruments will display PASS

14 6.0 HARDWARE SECTION. 6.1 Checking hardware calibrations. To check that the instrument is in good working order the sensors, (Temperature and Capacitance) should be checked as follows: Temperature: Pour the sample around the sensor covering the fins totally. Leave for 30 seconds so that the sample and sensor temperature reach equilibrium. Check the temperature of grain using an accurate thermometer. Switch on the instrument and press TEMP. The two readings should not differ by more than 1.5 C. Capacitance: This is checked using a capacitance reference sample (code 0 sample). Contact your instrument supplier for this sample. Pour the sample around the sensor covering the fins. the 0 button and then the %H20 The displayed result should be no greater than ±0.3 from the value of the code 0 sample. The code 0 value is written on the side of the sample container. If any of these measurements are out of tolerance, the instrument should be recalibrated. 6.2 Resetting hardware. Ensure there is no sample around the sensor. Switch on I - HI - and hold CAL AUTO CAL. Enter password and press P. P and hold CAL AUTO HCAL

15 and hold bleeps. AVER until unit 1 1 1 Surround the sensor with a capacitance reference sample (e.g. 28.1). Allow 1 minute for the sensor and sample temperature to equalise. Enter Reference Value (e.g. 28.1). 2 7 2 27 once. 28 1. 281 lb/bu kg/hl 28.1

16 Enter Temperature. Insert thermometer or temperature probe into grain and note reading, (e.g. 21.0 C). 2 2 1 21 0 210 TEMP 21.0 and hold bleeps. %H 2 2 0 until analyser This completes the hardware resetting. Now check the temperature and capacitance readings. 7.0 CHANGING DEFAULT SETTINGS. 2 2

17 The following options are available: a) Temperature - C or F. b) Baud rate setting of 300 or 4800. c) High or low frequency moisture measurement. The procedure to change from one default setting to the other is as follows: Switch on I - HI - and hold CAL AUTO CAL. Enter password and press P P CAL AUTO COPA CAL AUTO button again. SEt

18 In this mode the following keys have specific functions: TEMP AVER When this key is held down, the display changes from USA to Euro or vice versa. In Euro units the readings are C for temperature. In USA units, the readings are F for temperature. When this key is held down the baud rate changes from 300 to 4800 or vice versa.

8.0 TECHNICAL SPECIFICATION. 19 8.1 Display unit. Dimensions (mm): Display Unit Weight: H195 x W154 x D33 0.6 KG Max. Number of Sensors: 1 Display Unit Construction: Fabricated aluminium alloy, powder coated. Operating Environment: Storage Temperature: Humidity: Display: Processor: Memory: 0 to +55 C. -20 C to +55 C; Humidity to 95% non condensing. Up to 95% non condensing. 3.5 character 20mm LCD. Intel 80C31 microprocessor. EPROM and RAM Calibrations supplied. (Upgradable via the RS232 port). 7 Max. calibration capacity: 7 Data Output Format: Moisture Accuracy: Readout Interval. Temperature Accuracy: RS232 C, ASCII code, 300 Baud. ± 0.5% dependant on application and moisture level. 4 seconds. ± 1 C. Displayed Temperature: C or F Display Resolution: Temperature Correction: 1 Decimal place. Temperature sensor mounted on fin. Correction factor is software programmable. Correction range 0-40 C. 8.2 Sensor. Sensor Dimensions (mm): 80 x 380 Sensor Weight: Operating Environment: Storage Temperature: Humidity: 0.8 KG 0 to +65 C. -20 C to +80 C; Humidity to 95% non condensing. Up to 95% non condensing.

20 9.0 SINAR MOISTURE PROBE ACCESSORIES. The following are a list of accessories which are compatible with the Sinar Moisture Probe. Please contact your instrument supplier for more details. Part Number Title 1900-6309 Moisture Net calibration software. (Without curve library). 1900-6229 Moisture Net calibration software. (With curve library). 19006940 F4 Email upgrade package