TECHNICAL MANUAL. e-kronos Code CB1137. Technical manual e-kronos Rev

Similar documents
Temperature control unit

User Guide. For controller on CXAO / RTXB heat pumps CGCM / CXCM 2 circuit units. CNT-SVU005C-GB Original instructions

User Guide. Multipipe Units CMAA / RTMA CNT-SVU004B-GB

IntesisBox SMS - Mitsubishi Electric air conditioners

Modbus communication module for TCX2: AEX-MOD

1/7. Field settings table [6.8.2] =... ID66F2 / ID66F3. Applicable indoor units. *GSQH10S18AA9W ThermaliaC12* Notes 4P E

Operating instructions for RAMSES 811 top2_812 top2 and RAMSES 831 top2_832 top2

RAMSES D GB F NL. Installation and operating instructions Room thermostat. RAMSES 832 top2

Weekday / weekend room temperature controller

VARIA VARIA 826 S WH KNX VARIA 826 S BK KNX D GB F I E NL. Installation and operating instructions Room thermostat VARIA 826 S KNX

Model FP700 Owner s Instructions

Model: Touchpad (TFT) Model: TFT

AMBIFLEX MF626 - USER GUIDE

2 Zone Time Clock. User Guide UFHTIME2B

WIRED REMOTE CONTROLLER OPERATION MANUAL

Supplementary operating instructions for your air curtain system Controller TMC 500

76 F. Ductless Split Air Conditioner. YR-E16b Wired Controller User Manual WARNING

Model: Available in : Sapphire Black and Glacier White

OP10. Pre-programmed, configurable controller for simple applications

7-day room temperature controller

PT712-EI FOR FLOOR HEATING DIGITAL THERMOSTAT

Model: Available in : Sapphire Black and Glacier White

IntesisBox KNX - AIRZONE

OPERATION MANUAL. Room thermostat EKRTW

OPERATION MANUAL. Remote controller BRC1D527

Weekday / weekend room temperature controller

FANCOIL CONTROLLER UNIT TC17B01KNX. Product Handbook

Product and function description

KNX/EIB Push button sensor 3 Plus F Safety instructions. 2 Device components. 3 Function

Products no longer available

Supplied with. Calibration certificate. TM 200 Thermometer

Operating Instructions

Gavita Master Controller EL1

TiLocalDisplayNew. Software Manual 07/12-01 PC

ML Multi Stage Thermostat Installation & User Guide

idigit CONTROL INSTALLER MANUAL Digital thermostat for fan coil units Rev100

FAUN PROFESSIONAL, NEW GENERATION INDICATING CALCULATOR FOR SEPARABLE HEAT METERS

TDC+ CONTROLLER. Programming Guide

GRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2

Instructions. Installation and Operation of the Prodigy Smart-Board, KSB

ScottishPower Connect. User Guide

Smarther X8000-X8000W

RWD32S Software Tool. Operating Instructions. CE1U3344en Building Technologies

7-day room temperature controller

Navigating the Menus and Keypad

Instructions. Installation & Operation of the Prodigy Smart-Board, KSBU-N

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

Operation 6035 ENGLISH PROG MENU

USER MANUAL Video Particle Counter with built in Camera Model VPC300

Multiple Channel Digital Control and Programmable DC Power Supply Model: , , and

SUPERVISION AND CONTROL FOR HYDRONIC TERMINAL UNITS

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

WavePRO Wireless Programmable T2500 Thermostat & R2500 Receiver OPERATING MANUAL. Model K

SERVICE TOOL EVOLUTION

Operation Guide CT101

System 450 Series Reset Control Modules with Real-Time Clock and Relay Output

Supplied with. Calibration certificate. HD 200 Hygrometer

LDCL DIGITAL CONTROLLER OPERATING MANUAL

Daikin HVAC Controls Guide Specification

ERT50T Triac Noiseless Digital Room Thermostat for Underfloor Heating Applications

Table 1 Specifications Software Required for Configuration

STRA-17 Room controller. Installation and maintenance manual. Content

Functions. Technical Data. Wireless Room Thermostat

Model: EP210. Dual channel programmable controller. Installation Manual

USER MANUAL MINI WILDLIFE CAMERA

OPERATING MANUAL. Quality control system on the production complies with requirements ISO 9001:2008

Heatmiser Netmonitor

Programmable Room Thermostat. User Guide UFHPROGB & UFHPROGRFB

REMOTE METER USER MANUAL KAMPPTRC

Supplied with. Calibration certificate. TM 200 Thermometer

Operating Instructions. Radio timer thermostat display. Table of contents

GCI-5K INSTALLATION AND OPERATOR S MANUAL

INSTRUCTIONS FOR USING THE CONTROL PANEL

TLR-D42 with OPA-D42 Intelligent PI fan coil controller for modulating actuators. Cabinet mounted base, wall mounted operation terminal.

User Manual Video Borescope Model

RCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs

Heatmiser MC Operating Instructions

Network Management Card & Modbus/ Jbus

Vgraph Hardware manual ver Code 114VGRAHWE01. Vgraph CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY ENGLISH. HARDWARE MANUAL ver. 1.

! Ranges from -45º to 650ºC. ! Rapid heating, cooling and settling. ! Switch test, ramp, step and preset functions

BNI IOL K023 BNI IOL K023. User s Guide

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL

USER GUIDE Digital programmable Thermostat GUIDE D UTILISATION Thermostat digital programmable 42-87

deltadue series DIN rail mounting modules for control and data acquisition

Product and Application Description

ECL Comfort V a.c. and 24 V a.c.

BL67 electronic module 8 configurable digital channels, PNP, channel diagnostics, 0.5 A BL67-8XSG-PD

IntesisBox KNX. User Manual v10 r10 eng. Mitsubishi Electric air conditioners (Domestic & Mr.Slim lines) Release V.0.2

Operation Guide CT100

User guide. SonoMeter 30. Ultrasonic energy meter for heating and cooling applications. Danfoss VUIGI102 1

PowerView. Model PV-101-A, V2.3 User s Guide Section 78

Dryer. M720 Programming and Operation Manual. July 15, 2015 Revision 1.51

Smart Touch Thermostat Colour Touchscreen Thermostat

Using the LR-HVAC-230-S Thermostat w/ HomeWorks QS

IntesisBox PA-AW-MBS-1 v.2.0

IGLOO IGLOO EASY INSTRUCTION MANUAL

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

SERVICE MANUAL VMF-E5

User instructions. By-me automation module for video door entry unit.

HuBERT Build Master Calendar

Transcription:

TECHNICAL MANUAL e-kronos Code CB1137 Technical manual e-kronos Rev. 2013-04

Dear user, thank you for choosing our product. ICI Kronos comes from a non-stop research and state of the art technology. Genuine quality materials and components make our device a very reliable product. Our range of products follows all UNI, CEI and EN directives related to safety and electromagnetic compatibility (Directive 72/23/EEC relating to electrical equipment designed for use within certain voltage limits and Directive 89/336/CEE relating to electromagnetic compatibility). We recommend to follow the instructions in this manual with great care. e-kronos controller allows the control and reading of the NEREIX metering stations. Depending on the firmware loaded on the device, the user can change the operating modes, the menus, the icons and the language Technical manual e-kronos Rev. 2013-04 Pag.2

CONTENTS 1 MAIN PAGE...4 2 MENU...5 2.1 SEASON AND TEMPERATURE... 5 2.2 PROGRAM... 6 2.3 HOLIDAY... 7 2.4 METERS... 7 2.5 SHOW TEMPERATURE... 8 2.6 DATE AND TIME... 8 2.7 CONFIGURATION... 9 2.8 LANGUAGE SELECTION... 9 2.9 BACK-LIGHT... 10 3 CELLPHONE COMMANDS VIA SMS...10 4 VISUAL MODE...10 5 ASSEMBLY AND ELECTRICAL CONNECTION...11 Technical manual e-kronos Rev. 2013-04 Pag.3

1 MAIN PAGE The keys have variable functions, depending on the icon placed above them on various pages. Current values Temperature Day Date Time HOLIDAY program active % Relative humidity Scheduled operating mode 19.1 C Monday 12/09/2008 12:42 HOLID - 20.0 C + Heating on Displayed zone Winter season icon ** Set temperature Key 1 - operation mode switch Zone selection and menu access key Key 4 - Set temperature correction ( +) Key 3 - Set temperature correction (-) * * When humidity sensor is installed, UR is displayed: xx % during holidays. In "HOLIDAY" mode, the two messages will be displayed alternately. ** If set season is not "WINTER" icons on the main page will be: Sumer icon Cooling enabled In mid season no icon will be displayed, heating and cooling are not enabled. Operating mode switch, by pressing this key repeatedly, the user can switch the operating mode: Manual operating mode, keeps the temperature set on display steady. This value can be changed directly by pressing + and - Scheduled operating mode, manages the temperatures set in the program General Shutdown Mode, the only active function is the anti-freeze function If the module is set to two zones: A short press of the button will display zone 2 information. By shortly pressing the button again zone 1 information will be displayed. By pressing the key for more than 3 seconds you can access the menu (see paragraph 2) If the module is set to only one zone: above the button only the menu symbol will be displayed and no number regarding the zone will be displayed By pressing and holding see point 2.2 button, the display will show the current day program. In order to implement changes When anti-freeze mode in enabled, the main screen displays only the Heating icon. In this case the set temperature or the + and - keys will not be displayed. Technical manual e-kronos Rev. 2013-04 Pag.4

2 MENU By pressing the menu access key, various options will be displayed; those not displayed on the screen can be accessed by pressing the arrow keys. Season - Temperature Zone 1 program Zone 2 program (if present) Holiday Meters Show temperatures Date and time Configuration Language setting Back-light - MENU - Season - Temperature Zone 1 program Zone 2 program Holiday Meters Return to previous menu Menu selection key Confirm Select the desired menu using the arrow keys and press the key in order to enter individual menus. 2.1 SEASON AND TEMPERATURE This will be followed by ZONE 2 if provided - Season - Temperature - Season: WINTER Output temp. 60.0 C Dom.hot water temp. 48.0 C Antifreeze t. 16.0 C Comfort T. Z1: 20.0 C Reduced T. Z1: 20.0 C Depending on the Nereix module installed In order to edit individual values select them with the highlighted arrow keys and press the button Once the value is highlighted use the arrow keys in order to correct it and key for confirmation. NOTE - Anti-freezing temperature can also be set to Off, in this case the function is disabled. Delivery and health temperatures can be set within preset limits 2 - After zone 1 temperatures are displayed, zone 2 (if provided) temperatures are displayed, use the arrows keys for access. 3 - By changing the season, specific setpoints are displayed and editable. 4 - Last parameter allows users to change environment probe reading (temperature offset) Technical manual e-kronos Rev. 2013-04 Pag.5

2.2 PROGRAM Area referenced by the program Monday Tuesday Wednesday Wednesday Thursday Friday - Program 1 - Monday 06:00-06:30 16 C For parameters select the day with key and press.. A page will appear, in which every box represents the midday A full square represents operation at domestic hot water temperature A half-full square represents operation at reduced temperature A small line shows system shutdown (or steady operation at antifreeze temperature) Select the time slot using the arrow keys in order to change the required temperature (comfort, reduced or antifreeze) press instead of the icon the + /- signs will appear and instead of icon will appear Press to confirm any change. By pressing the arrows, the newly set time range moves to next or previous. From the main screen of the PROGRAM menu, the program attributed to a specific day can be copied to any other day: After using this key in order to select desired day to be copied, press key.on the left side of selected day a "C" will appear. Above the icon the name of desired day to be copied will appear With key move to the day you want to copy the program to and press. Repeat this operation and select other days of the week. Technical manual e-kronos Rev. 2013-04 Pag.6

2.3 HOLIDAY - Holiday end - Time: 09 Day 12 Month: 09 Year: 2013 Holiday temperat. 10.0 C Set holiday On Using the arrow keys select the parameter to be modified, by pressing key. Modify using + and - keys. Press to confirm possible modifications. By entering the ON value to "Set holiday", the selected temperature (for both areas) will be kept until the established moment. At the holiday end operation will return previous mode of operation. Use key in order to exit the menu. 2.4 METERS - Energy meters - - Capacity meters Heating Total energy: 000112,6 kwh Cooling Total energy: 000015,1 kwh Meter sanit.1: 12345678 Lit. Meter sanit. 2: 00000012 Lit. Meter sanit.3: 00000000 Lit. Use the arrow keys to browse the screens and to exit the menu Technical manual e-kronos Rev. 2013-04 Pag.7

2.5 SHOW TEMPERATURE - Current Temp. Ambient 1: 19.8 C Temp. Ambient 2: 19.0 C External temp. 10.2 C Output temp. 50.2 C Dom. hot water temp. 30.2 C Visible if temperature sensor is present second zone Visible if an external sensor, connected to Master or single Slave, is present Visible, depending on Nereix type Use key in order to exit the menu. 2.6 DATE AND TIME - Date and time - Day 15 Month: 09 Year: 2008 Time: 17 Minute: 44 Using the arrow keys select the parameter to be modified, by pressing button. Modify using + and - keys. Press to confirm possible modifications. Obs. In case a Master unit is present, the date and time are not editable. Date and time are set on central unit. Use key in order to exit the menu. Technical manual e-kronos Rev. 2013-04 Pag.8

2.7 CONFIGURATION - Configuration - e-kronos SN: e-kronos FW: Bus Address: Slave Type: Slave SN: Slave FW: From this menu the following Slave configuration information can be viewed: - e-kronos SN = e-kronos equipment serial number - e-kronos FW = e-kronos firmware review - Bus Address = Bus adress of ekronos connected module (251 = disconnected module) - Slave Type = Unit module type (Metering / Climate) - Slave SN = Nereix module electronic board serial number - Slave FW = Nereix module electronic board review - Heat Meter 1 SN = Calorimeter 1 serial number - Heat Meter 2 SN = Calorimeter 2 serial number (if present) - Counter 1 = Volumetric meter 1 liter count (hot water) - Counter 2 = Volumetric meter 2 liter count (cold water) - Counter 3 = Volumetric meter 3 liter count (non treated water) - Offset = Temperature probe reading correction * * Ambient temperature value read by the internal sensor can be modified with a value between + or - 10 C. In order to make a correction press, use the + and keys, confirm with OK. 2.8 LANGUAGE SELECTION Italian English Spanish French - Language selection From this menu language selection is possible. Available languages depend on firmware version Technical manual e-kronos Rev. 2013-04 Pag.9

2.9 BACK-LIGHT - Back-light - Zone 1: 01/10 Zone 2: 05/10 Start F2: 00:00 End F2: 00:00 From this menu you can turn off the back-light or set it so it will turn off after a few seconds since the last press of a button. The back-light can be set on 2 levels depending on the time Each level can be set to off (disabled) or between 01/10 and 10/10 3 CELLPHONE COMMANDS VIA SMS Using received "SMS Code" the user can send a few SMS commands to the slave unit. In order to use this feature, the Slave must necessarily be connected to an ICI Kronos and to a Master unit equipped with a modem. Commands syntax that can be sent via SMS: # SMS code "space" MAN "space" desired temperature: ICI Kronos transfers to manual operation and supplies desired temperature. # SMS code "space" AUTO ICI Kronos transfers to automatic operation according to installed program # SMS code "space" OFF ICI Kronos shuts down. Example: if the SMS code was " 5555555 ", forwarded command will be: #5555555 MAN 20. The system will transfer to manual operation with desired temperature of 20 C. IN CASE MORE THAN ONE ZONE EXIST, THE SMS COMMANDS WILL HAVE AN EFFECT ON ALL ZONES 4 VISUAL MODE In "VISUAL" mode the e-kronos unit does not work with a programmable thermostat so it does not control heating / ambient cooling. In this mode only the following menus are available: Meters Show temperature Date and time Configuration For mode switching go to "Configuration" menu. By pressing simultaneously the 2 buttons on the right (arrow up/down) for 5 seconds the display will shows the message: "Confirm VISUAL mode" By pressing the "Enter" key, the device switches to View mode, by pressing the "Esc" key, mode change will be canceled. When in View mode, users can return to Normal mode with the same procedure. By pressing simultaneously the 2 buttons on the right (arrow up/down) for 5 seconds the display will shows the message: "Confirm VISUAL mode" Technical manual e-kronos Rev. 2013-04 Pag.10

5 ASSEMBLY AND ELECTRICAL CONNECTION Assembly procedure: Connect the cable coming from the Nereix unit to the appropriate three pole removable terminal. Insert the terminal in the equipment. Remove the front panel. Attach the device with two plugs using the diametrically opposed holes. In case of broadside box, remove the display and electronics from plastic container and secure it. Reinstall electronic parts and display (if removed) and front panel. IMPROTANT: e-kronos is powered directly from NEREIX satellite user board. All operations should be carried out with NEREIX unit unplugged. In the event of voltage absence, settings are stored in equipment microprocessor. Electric wiring: Communication between e-kronos and NEREIX modules is done through a bus connection. The connection must be insured by a 3-poler shielded cable (section 3x0.35mm 2 ) of maximum 90 meters. Never place in the same slot data and power cables. In the same slot can be placed master BUS cables and e-kronos cables. The e-kronos unit is supplied with 24 Vcc from the Nereix module Obs. Do not switch power supply polarity Respect + S - connections "MANAGEMENT" BOARD "CLIMATE" BOARD e-kronos / ICI Kronos e-kronos / ICI Kronos HIGH Technical manual e-kronos Rev. 2013-04 Pag.11

Member of Filniuc Group, registerd R.I. VAT no. 02245640236 Via G. Pascoli, 38-37059 Zevio - fraz. Campagnola - VERONA - ITALIA Tel. 045/8738511 - Fax 045/8731148 info@icicaldaie.com - www.icicaldaie.com Information contained in this booklet is provided as a rough guide and our company has no obligation regarding its content. The information contained herein can be subject to variations for continuous improvement and constant updating. Technical manual e-kronos Rev. 2013-04 Pag.12