RM4TA32 three-phase network control relay RM4-T - range V

Similar documents
RM4TR31 three-phase network control relay RM4-T - range V

RM4JA31M current measurement relay RM4-J - range ma V AC

RM4LA32M liquid level control relay RM4-L V AC

RM4JA01F current measurement relay RM4-J - range ma V AC

RM4JA32MW current measurement relay RM4-J - range A V AC DC

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

RM4UA33M voltage measurement relay RM4-U - range V V AC

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

RE9RA21MW7 off-delay timing relay s V AC -

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

RMCN22BD Analog Converter ma - for Zelio Analog

RSB1A160JD interface plug-in relay - Zelio RSB - 1 C/O - 12 V DC - 16 A

RPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RXM4AB1BD miniature plug-in relay - Zelio RXM - 4 C/O - 24 V DC - 6 A

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

RM35LM33MW liquid level control relay RM35-L V AC/DC

RM35TF V AC

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RM35LM33MW liquid level control relay RM35-L V AC/DC

RPM13F7 power plug-in relay - Zelio RPM - 1 C/O V AC - 15 A - with LED

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

ABR1S102B. Main. Contacts type and composition [Uc] control circuit voltage Control circuit type

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

TM3DI16G module TM3-16 inputs spring

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

SR2B121B compact smart relay Zelio Logic - 12 I O - 24 V AC - clock - display

ABS2EC01EB input interface module mm - solid state - 24 V DC

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT

XCKJ10511 limit switch XCKJ - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

TM3TI4 module TM3-4 inputs temperature

XCKL115 limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

ABL1REM Main. Rated power in W. Power supply output current V. <= 100 Aat 230 V AC. 2.5 Aat 240 V

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

K1F006ALH cam switch - 6-pole A - screw mounting

SR2B202BD compact smart relay Zelio Logic - 20 I O - 24 V DC - clock - display

XB7EV07BP round pilot light Ø 22 - clear - integral LED - 24 V - screw clamp terminals

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

XCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ABL8MEM24006 regulated SMPS - 1 or 2-phase V AC - 24 V A

XCKP2145G11 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - Pg11

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

TM3SAF. Main. Device short name

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

RM17UB3. Price* : USD

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

SR2D101BD compact smart relay Zelio Logic - 10 I O - 24 V DC - no clock - no display

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

XPSMC32Z safety controller XPS-MC - 24 V DC - 32 input - 46 LEDs signalling

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

SR3B261BD modular smart relay Zelio Logic - 26 I O - 24 V DC - clock - display

XACA2074 pendant station XAC-A pistol grip - 2 push buttons 1 Emergency stop

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

XB4BS542 red Ø40 Emergency switching off pushbutton Ø22 latching turn release 1NC

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling

SR2A201BD. Main. <= 0.5 ma for IB...IG used as discrete input circuit. <= 5 Vfor IB...IG used as discrete input circuit V

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

SR2E121B compact smart relay Zelio Logic - 12 I O - 24 V AC - clock - no display

TM258LD42DT4L compact base M I/O - 24 V DC

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

K1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

TM221M16R controller M IO relay

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

SR3XT101BD discrete I/O extension module - 10 I O - 24 V DC - for Zelio Logic

TM221CE24R controller M IO relay Ethernet

RE Product data sheet Characteristics. time delay relay for star-delta starter ms - 230/380 V AC - 1 contact. Main.

XUX9ARCNT16 photo-electric sensor - XUX - polarised - Sn 11m VAC/DC - terminals

Transcription:

Characteristics three-phase network control relay RM4-T - range 380..500 V Complementary [Us] rated supply voltage Output contacts Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Time delay Measurement range Contacts type and composition Poles description 380...440 V 50/60 Hz 2 C/O Setting accuracy of the switching threshold +/-3 % Switching threshold drift Setting accuracy of time delay Time delay drift Hysteresis Delay at power up Measuring cycle Zelio Control Industrial measurement and control relays Control relay For 3-phase supply RM4-T Asymmetry Phase failure detection Phase sequence Adjustable 0.1...10 s 290...484 V 2 C/O 3P <= 0.5 % within the measuring range <= 0.06 % per degree centigrade depending permissible ambient air temperature 10 P <= 0.5 % within the measuring range <= 0.07 % per degree centigrade depending on the rated operational temperature 50 % fixed of asymmetry percentage < 650 ms <= 80 ms Adjustment of asymmetry threshold 5...15 % Marking CE : EMC 89/336/EEC CE : LVD 73/23/EEC Overvoltage category III conforming to IEC 60664-1 [Ui] rated insulation voltage 500 V conforming to IEC Supply frequency 50/60 Hz +/- 5 % Operating position Connections - terminals Tightening torque Mechanical durability [Ith] conventional free air thermal current Any position without Screw terminals 2 x 2.5 mm², flexible cable without cable end Screw terminals 2 x 1.5 mm², flexible cable with cable end 0.6...1.1 N.m <= 30000000 cycles 8 A [Ie] rated operational current 0.3 A at 70 C 115 V DC-13 conforming to VDE 0660 0.3 A at 70 C 115 V DC-13 conforming to IEC 60947-5-1/1991 0.1 A at 70 C 250 V DC-13 conforming to VDE 0660 0.1 A at 70 C 250 V DC-13 conforming to IEC 60947-5-1/1991 3 A at 70 C 250 V AC-15 conforming to VDE 0660 3 A at 70 C 250 V AC-15 conforming to IEC 60947-5-1/1991 3 A at 70 C 24 V AC-15 conforming to VDE 0660 3 A at 70 C 24 V AC-15 conforming to IEC 60947-5-1/1991 3 A at 70 C 115 V AC-15 conforming to VDE 0660 3 A at 70 C 115 V AC-15 conforming to IEC 60947-5-1/1991 2 A at 70 C 24 V DC-13 conforming to VDE 0660 2 A at 70 C 24 V DC-13 conforming to IEC 60947-5-1/1991 Switching capacity in ma 10 ma at 12 V The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Jan 8, 2015 1

Switching voltage Contacts material Number of cables 2 Height Width Depth Terminals description ISO n 1 Output relay state 9 mm pitches 2.5 Product weight Time delay on de-energisation 250 V AC <= 440 V AC 90/10 silver nickel contacts 78 mm 22.5 mm 80 mm (15-16-18)OC (25-26-28)OC (L1-L2-L3)CO Tripped, fault present 0.11 kg 0.1...10 s Environment Standards EN/IEC 60255-6 Product certifications CSA GL UL Ambient air temperature for storage -40...85 C Ambient air temperature for operation -20...65 C Relative humidity 15...85 % 3K3 conforming to IEC 60721-3-3 Vibration resistance 0.35 ms (f = 10...55 Hz) conforming to IEC 60068-2-6 Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27 IP degree of protection IP50 (casing) conforming to IEC 60529 IP20 (terminals) conforming to IEC 60529 Pollution degree 3 conforming to IEC 60664-1 Dielectric test voltage Non-dissipating shock wave 2.5 kv 4.8 kv Resistance to electrostatic discharge 8 kv air conforming to IEC 61000-4-2 level 3 6 kv contact conforming to IEC 61000-4-2 level 3 Resistance to electromagnetic fields 10 V/m conforming to IEC 61000-4-3 level 3 Resistance to fast transients 2 kv conforming to IEC 61000-4-4 level 3 Protection against electric shocks 2 kv conforming to IEC 61000-4-5 level 3 Disturbance radiated/conducted CISPR 11 group 1 - class A CISPR 22 - class A 2

Dimensions Drawings 3-phase Supply Control Relays Dimensions 3

Mounting and Clearance 3-phase Supply Control Relays Rail mounting Screw fixing 4

Connections and Schema 3-Phase Supply Control Relays Wiring Diagram L1, Supply to be monitored L2, L3 15-18, 1st C/O contact of the output relay 15-16 25-28, 2nd C/O contact of the output relay 25-26 Application Scheme Example (1) Fault 5

Performance Curves Electrical Durability and Load Limit Curves AC Load Curve 1: Electrical durability of contacts on resistive load in millions of operating cycles X Current broken in A Y Millions of operating cycles Curve 2: Reduction factor k for inductive loads (applies to values taken from durability Curve 1) X Power factor on breaking (cos φ) Y Reduction factor K Example: An LC1-F185 contactor supplied with 115 V/50 Hz for a consumption of 55 VA or a current consumption equal to 0.5 A and cos φ = 0.3. For 0.5 A, curve 1 indicates a durability of approximately 1.5 million operating cycles. As the load is inductive, it is necessary to apply a reduction coefficient k to this number of cycles as indicated by curve 2. For cos φ = 0.3: k = 0.6 The electrical durability therefore becomes: 1.5 x 10 6 operating cycles x 0.6 = 900 000 operating cycles DC Load Load limit curve X Current in A Y Voltage in V 1 L/R = 20 ms 2 L/R with load protection diode 3 Resistive load 6

Technical Description Function Diagram Detection of Phase Asymmetry t Time delay (1) Asymmetry > set threshold 15-18, Output relays connections (refer to Connections and Schema) 15-16; 25-28, 25-26 NOTE: If there is distortion of the 3-phase supply sine wave, malfunctioning of the 3-phase supply control relay is possible. Relay status: black color = energized. 7