FieldPoint. FP-1000/1001 FieldPoint Quick Start Guide. Install the Network Module Mount the module on a DIN rail. What You Need to Get Set Up

Similar documents
FP-2000/2010 FieldPoint Quick Start Guide

QUICK START GUIDE. What You Need to Get Set Up

FP-PS-4. Features. Installation

FP-1600 FieldPoint Quick Start Guide

FieldPoint cfp-20xx. Quick Start Guide. What You Need to Get Set Up

You need the following to set up and use your terminal block:

FP-AO-210 AND CFP-AO-210

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9871E

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9870E

FP-AO-200 AND CFP-AO-200

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9208E 16-Channel, ±20 ma, 24-Bit Analog Input Module

Calibrating FieldPoint Analog Input Modules with Calibration Executive

cfp-rly-421 Features Installing the cfp-rly-421 FieldPoint Operating Instructions Eight-Channel SPST Relay Module

INSTALLATION INSTRUCTIONS LFH160 Cable

TBX-96 TERMINAL BLOCK

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices

NI 6521 Specifications

VME-GPIB Installation and User Guide

Compact FieldPoint cfp-cal

FP-AIO-600 and cfp-aio-600

Compact FieldPoint cfp-1808

NI SD Card Memory Module

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, ±10 V, 16-Bit Analog Voltage Output Module

NI 653x Cable Adapter

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 24 V Logic, Sinking Digital Input Device

FieldPoint cfp-21xx. Quick Start Guide. What You Need to Get Set Up

Ethernet/Serial Interfaces for Compact FieldPoint

NI SMB-2145/2146/2147/2148

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 24 V Logic, Sourcing Digital Output Device

Getting Started with the NI 8234

NI Channel, 0 20 ma, 16-Bit Analog Current Output Module

LabVIEW DSP Module. Contents. Introduction RELEASE NOTES. Version 1.0

Getting Started with the NI PCI-1405

Getting Started with NI-Motion for NI 73xx Motion Controllers

CB-27T, TBX-68T, AND CB-68T ISOTHERMAL TERMINAL BLOCKS INSTALLATION GUIDE

Caution Electrostatic discharge can damage your controller. To avoid such damage, handle the controller only in a proper ESD-controlled environment.

USER GUIDE Universal Motion Interface (UMI)-7764

Getting Started with the NI PCI-8254R

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, 0 20 ma, 16-Bit Analog Current Output Module

NI PCIe-8255R Quick Start Guide

NI CAN Demo Box. NI CAN Demo Box User Guide. Power supply (+9 VDC to +12 VDC) 68-pin Multifunction Data Acquisition board

Getting Started with the NI PCIe-8255R

NI 6584R User Guide and Specifications

Getting Started with the NI PCIe-1433

Getting Started with R Series Intelligent DAQ

Getting Started with R Series Multifunction RIO

Getting Started with the NI 8234

Getting Started with the NI PCIe-8253

Getting Started with the NI PCIe-8235

Getting Started with the NI PXI/PCIe-8231

Electrical. SPECIFICATIONS SH Cable

NI USB-9201/9221. Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 12-Bit Analog Input Devices

FieldPoint. Note to Users

NI 9213 Calibration Procedure

INSTALLATION INSTRUCTIONS SH160F-160M-NI SwitchBlock Cable

SCC-RLY01 Relay Module

TBX-1316 High-Voltage Attenuator Terminal Block

8x16, 2-Wire Terminal Block for the NI PXI The following conventions are used in this guide:

SCXI HIGH-VOLTAGE 8 4 MATRIX TERMINAL BLOCK

INSTALLATION INSTRUCTIONS NI TB-2630B Terminal Block for the NI PXI-2530B. Contents. Introduction

Getting Results with the NI PXI-6585R

SPECIFICATIONS AND FEATURES GUIDE NI Serial Legacy Hardware

SCXI -1313A Terminal Block

CompactRIO Reconfigurable Embedded Chassis

This installation guide describes how to install and connect signals to the NI TBX-2808 screw terminal accessory for use with NI SwitchBlock cards.

IVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter

Getting Started with the NI PXI/PCI-1422

SCC-AO10 Isolated Analog Output Module

CompactRIO NI crio-9012/9014

SH Cable Specifications

FieldPoint FP-1000/1001 User Manual

SCXI OFFSET-NULL AND SHUNT-CALIBRATION HIGH-VOLTAGE TERMINAL BLOCK INSTALLATION GUIDE

Getting Results with the NI 5752R

Installation Instructions

NI CardBus-8310-to-PXI Expansion Kit

Agilent U2751A USB Modular Switch Matrix. Data Sheet

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9476E. 32-Channel, 24 V Sourcing Digital Output Module

Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

LabVIEW DSP Module Release and Upgrade Notes

Getting Started with the NI PXI/PCI-1409

NI PXI-2567 Specifications

CISCO 7304 SERIES ROUTER PORT ADAPTER CARRIER CARD

DATA SHEET. Catalyst Inline Power Patch Panel

Sample. LabWindows TM /CVI TM Core 1 Exercises Manual

Instructions. (For 6180 Industrial Computers) Applications. Overview & Safety

Instructions. (For 6180 Industrial Computers) Installing a Processor Upgrade

Reconfigurable Embedded Chassis with Integrated MXI-Express (x1) MXI-Express Switch

NI SPEEDY-33. '7 NATIONAL INSTALLATIONGUIDE. P~ClCl J ~ Ig~~!1 "INSTRUMENTSN. 1~~~~~~g~~lm.OOOQ{JOOO,

NI TB Introduction. Conventions INSTALLATION INSTRUCTIONS Wire Terminal Block for the NI PXI-2529

PRODUCT DATA. Wideband Ear Simulator Type 4195-Q for Production Line Testing of Telephones

For NI PXI and NI SCXI Switch Modules

AC/DC (120V) Input Module Cat. No IAD Series C

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

Sample. LabWindows TM /CVI TM Core 1 Course Manual

NI What You Need to Get Started. Unpacking INSTALLATION GUIDE. This document explains how to set up your NI 8262 expansion module.

The NI TB-2648/2649/2650/2651 terminal blocks configure your NI PXI/PXIe-2531 (NI 2531) in one of the following topologies. 1-wire 8 64 matrix

Low-Cost Multifunction DAQ for USB

Power Analyzer Firmware Update Utility Version Software Release Notes

USER GUIDE SC-2075 SIGNAL CONDITIONING ACCESSORY

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module

Transcription:

TM FieldPoint FP-1000/1001 FieldPoint Quick Start Guide What You Need to Get Set Up Network module 35 mm DIN rail Two DIN rail locks (included) Terminal base(s) I/O module(s) 11 30 VDC power supply Accessories: serial cable, flathead screwdriver PC running Windows National Instruments FieldPoint Software CD 1 Install the Network Module Mount the module on a DIN rail. A. Unlock rail clip. National Instruments Corporation 1 FP-1000/1001 Quick Start Guide

NOTE Do not use spliced DIN rails. Use only a single DIN rail. B. Hook lip on back of module onto top of DIN rail, press down, and snap into place. C. Slide module into position and lock rail clip. FP-1000/1001 Quick Start Guide 2 ni.com

2 Install the Terminal Base(s) CAUTION Terminal bases must be connected to the network module before applying power to the module. Do not connect or disconnect terminal bases while power is applied to the network module. A. Unlock rail clip. B. Press base onto rail. National Instruments Corporation 3 FP 1000/1001 Quick Start Guide

C. Slide base into position and lock rail clip. Be careful not to bend any pins. D. Repeat for each terminal base, up to nine for each network module in most cases. You can use one or two extender cables (which you can order separately) if the FieldPoint bank is too long for the available space. Make sure there are no gaps between terminal bases. E. You must install DIN rail locks at each end of the bank to ensure reliable connections between terminal bases and network module. Two rail locks are included with each network module. Place protective cover on last base. FP-1000/1001 Quick Start Guide 4 ni.com

3 Install the I/O Module(s) It does not matter where you install each I/O module, except in the following cases: If you plan to cascade power between any I/O modules using the V and C terminals, those modules should be grouped together. CAUTION Cascading power defeats isolation. For more accurate measurements, place thermocouple modules away from heat sources, including network modules and relay modules. A. Align slots on module with guide rails on base, and press module onto base until base latch locks module in place. B. Repeat for each I/O module. National Instruments Corporation 5 FP 1000/1001 Quick Start Guide

4 Connect the Network Cables You have several network connection options with the FP-1000 and FP-1001, as shown here. Connecting the FP-1000 to a Computer s RS-232 Serial Port Use a male-to-female (straight through) cable to connect the computer s RS-232 port to the 9-position DSub RS-232 connector on the FP-1000. NOTE You cannot connect the RS-485 port of the FP-1000 directly to an RS-485 port on the computer. You must use an FP-1001 for this network connection. If you are using multiple FieldPoint serial network modules, you may need to connect the grounds of the RS-485 communication ports to each other to prevent damage from differences in ground potentials. FP-1000/1001 Quick Start Guide 6 ni.com

Connecting the FP-1000 to an FP-1001 You can connect up to 24 FP-1001 RS-485 serial network modules to an FP-1000. Use the RS-485 repeater port of the FP-1000, with the connection shown in this figure. A. Connect the TX outputs of the FP-1001 to the RX inputs of the FP-1000, and the RX inputs of the FP-1001 to the TX outputs of the FP-1000. FP-1000 FP-1001 B. Install the termination resistors. Terminate each end of your RS-485 network using the 120 Ω termination resistors included with the FP-1001. Install them between the RX and TX pair of the FP-1000 RS-485 port, and between the RX and TX pair on the last FP-1001 RS-485 port, as shown. Twist the resistor leads with the RS-485 signal wires and insert them into the RS-485 port terminals. 4 RX+ RX- GND TX- TX+ RX FP-1000 TX 1 2 3 RX FP-1001 RX+ RX- GND TX- TX+ TX RX FP-1001 RX+ RX- GND TX- TX+ TX 4 1 From the Computer s RS-232 Transmit Output 2 To Host Computer s RS-232 Receive Input 3 Ground 4 120 Ω Termination Resistors National Instruments Corporation 7 FP 1000/1001 Quick Start Guide

Connecting the FP-1001 to a Computer s RS-485 Serial Port You may connect up to 25 FP-1001 network modules to a single RS-485 port of a host computer. Use the connection shown in this figure. A. Connect the FP-1001 to a host computer using the 5-position Combicon screw terminal adapter of the RS-485 connector on the FP-1001. B. Install the 120 Ω termination resistors included with the FP-1001. Install them between the RX and TX pair of the host computer RS-485 port, and between the RX and TX pair on the RS-485 port of the last FP-1001 in the system, as shown. Twist the resistor leads with the RS-485 signal wires and insert them into the RS-485 port terminals. C. Check the biasing feature. The host computer RS-485 interface usually provides for biasing resistors, which are required on an RS-485 network. You should use this biasing feature for better reliability and noise immunity. TX RX RX FP-1001 RX+ RX- GND TX- TX+ TX FP-1001 RX FP-1001 RX+ RX- GND TX- TX+ TX FP-1000/1001 Quick Start Guide 8 ni.com

NOTE The pinout shown for the RS-485 DB-9 connector is for National Instruments RS-485 cards. Please refer to the manuals that came with your RS-485 card, as the pinout may vary by manufacturer. 5 Set the Network Address and Baud Rate If the default values do not work for you, remove the switch cover from the 8-position switch on the front of the FP-1000/1001 to set the network address and baud rate. Address 0 Address 1 Address 2 Address Baud Rate Default address 0 shown Default Baud Rate 115200 shown A. Check/Set the Network Address Give every network module connected to one serial port of the host computer a unique address. Modules on different serial ports may have the same address. The addresses of the terminal bases connected to the network module are automatically configured to be sequentially higher than the network module address, moving out from the network module. The default network address for the FP-1000/1001 is 0. National Instruments Corporation 9 FP 1000/1001 Quick Start Guide

Switch Positions 1-5 Network Module Address (Decimal) Switch Positions 1-5 Network Module Address (Decimal) Switch Positions 1-5 Network Module Address (Decimal) 0 Default 90 180 10 100 190 20 110 200 30 120 210 40 130 220 50 140 230 60 150 240 70 160 Other Settings Not Allowed 80 170 FP-1000/1001 Quick Start Guide 10 ni.com

B. Check/Set the Baud Rate Every module on one serial port of the host computer must have the same baud rate, which must be less than or equal to the baud rate of the computer serial port. The default baud rate for the FP-1000/1001 is 115200, which provides the fastest performance. You should not need to change this setting unless you experience communication problems. Switch Positions 6-8 Network Module Baud Rate Switch Positions 6-8 Network Module Baud Rate Switch Positions 6-8 Network Module Baud Rate 300 9600 57600 1200 19200 115200 (Default) 2400 38400 C. Apply the New Settings 1. Note the new settings on the FP-1000/1001 label so that you can refer to them when you configure the software. 2. If power is applied to the network module, cycle it off and back on again to enable the new settings. National Instruments Corporation 11 FP 1000/1001 Quick Start Guide

6 Wire Power to the FieldPoint System A. Connect power supply leads to the V and C terminals of the network module. For up to five I/O modules, use an 11 30 VDC, 15 W minimum power supply such as the FP-PS-4. If you have more than five modules, you need a 20 W power supply. Refer to the I/O module operating instructions for the power requirements of each module. Refer to the Specifications section of this document for instructions on calculating the power requirement of the FieldPoint bank. B. Connect power to the I/O modules that require external power for outputs (examples include output, counter, relay, PWM, PG, and QUAD modules). It is generally best to power each such module by connecting an external power supply to the V SUP and COM terminals. Refer to the I/O module operating instructions for power requirements, detailed wiring diagrams, and safe wiring practices. FP-1000/1001 Quick Start Guide 12 ni.com

CAUTION Cascading power from neighboring bases or network modules defeats isolation between cascaded modules. Separate Power Supply (Recommended) Cascaded Power (Reduces Isolation) No External Power Required FP-1000 FP-AI-110 FP-AO-200 FP-RLY-420 FP-TC-120 Shades of gray indicate different voltage potentials. 15 16 V 31 32 C V 1 2 3 C 17 18 Power supply connected to V SUP and COM terminals CAUTION Cascading power defeats isolation. National Instruments Corporation 13 FP 1000/1001 Quick Start Guide

7 Connect to Field Devices Use the operating instructions for each I/O module to help you connect field devices. 8 Power Up the FieldPoint System CAUTION Terminal bases must be connected to the FP-1000/1001 before power is applied to the FP-1000/1001. Plug in each power supply to the FieldPoint bank. You should see the FP-1000/1001 ACCESS and STATUS LEDs flash once and its POWER LED come on and stay on. After a few seconds, the POWER and READY LEDs should be lit on each I/O module. If the LEDs do not follow this sequence, refer to the FP-1000/1001 User Manual for troubleshooting instructions. POWER and READY LEDs Stay Lit After the hardware is installed, you should verify communication, configure the modules, and configure your power-up states and watchdog settings. FP-1000/1001 Quick Start Guide 14 ni.com

9 Install Software on the Host PC A. Install the software packages you plan to use, such as LabVIEW, LabVIEW RT, Measurement Studio, VI Logger, or LabWindows /CVI, before you install the FieldPoint software. The FieldPoint software installation installs the LabVIEW VIs and examples and the LabWindows/CVI instrument driver only if it finds the corresponding development software installed. B. Close all other applications. C. Insert the National Instruments Device Drivers CD into the CD-ROM drive on your computer. D. Follow the onscreen instructions to complete the installation. NOTE If the setup does not launch automatically, select Start»Run from Windows, enter d:\setup, where d is the letter of the CD-ROM drive, and select OK. 10 Where to Go from Here For information about configuring the FP-1000/1001 in software, refer to the Measurement & Automation Explorer Help for FieldPoint (Start»Programs» National Instruments»FieldPoint»FieldPoint Help). National Instruments Corporation 15 FP 1000/1001 Quick Start Guide

Specifications Network Network ports FP-1000................... 1 RS-232 port, 1 RS-485 repeater port FP-1001................... 1 RS-485 port Baud Rates..................... 300, 1200, 2400, 9600, 38400, 57600, 115200 (switch selectable) Communication parameters....... 1 start bit, 8 data bits, 1 stop bit, no parity RS-485 isolation................. 2,300 V rms breakdown Power Requirements Power supply range............. 11 30 VDC Recommended power supply FP-1000/1001 with up to 5 I/O modules......... 15 W (FP-PS-4 or equivalent) FP-1000/1001 with 6 to 9 I/O modules.......... 20 W Power consumption............. 1 W + 1.15(I/O module power requirements) Physical Characteristics Screw-terminal wiring........... 16 26 AWG copper conductor wire with 7 mm (0.28 in.) of insulation stripped from the end Torque for screw terminals....... 0.5 0.6 N m (4.4 5.3 lb in.) FP-1000/1001 Quick Start Guide 16 ni.com

Environmental FieldPoint modules are intended for indoor use only. For outdoor use, they must be installed in a suitable sealed enclosure. Operating temperature........... 40 to 70 C Storage temperature............. 55 to 85 C Humidity....................... 10 to 90% RH, noncondensing Maximum altitude............... 2,000 m; at higher altitudes the isolation voltage ratings must be lowered. Pollution Degree................ 2 Safety The FP-1000/1001 is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: EN 61010-1, IEC 61010-1 UL 3121-1, UL 61010C-1 CAN/CSA C22.2 No. 1010.1 NOTE For UL and other safety certifications, refer to the product label or to ni.com. Electromagnetic Compatibility CE, C-Tick and FCC Part 15 (Class A) Compliant Emissions...................... EN 55011 Class A at 10 m. FCC Part 15A above 1 GHz Immunity....................... EN 61326: 1997 + A2: 2001, Table 1 NOTE For EMC compliance, operate this device with shielded cabling. National Instruments Corporation 17 FP 1000/1001 Quick Start Guide

CE Compliance This product meets the essential requirements of applicable European Directives, as amended for CE Marking, as follows: Low-Voltage Directive (safety)..... 73/23/EEC Electromagnetic Compatibility Directive (EMC)................. 89/336/EEC NOTE Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, click Declarations of Conformity Information at ni.com/hardref.nsf/. Mechanical Dimensions 107.19 mm (4.22 in.) 109.5 mm (4.31 in.) 91.44 mm (3.60 in.) FP-1000/1001 Quick Start Guide 18 ni.com

Go to ni.com/support for the most current manuals, examples, and troubleshooting information. For telephone support in the United States, create your service request at ni.com/ask and follow the calling instructions or dial 512 795 8248. For telephone support outside the United States, contact your local branch office: Australia 02 612 9672 8846, Austria 43 0 662 45 79 90 0, Belgium 32 0 2 757 00 20, Brazil 55 11 3262 3599, Canada (Calgary) 403 274 9391, Canada (Montreal) 514 288 5722, Canada (Ottawa) 613 233 5949, Canada (Québec) 514 694 8521, Canada (Toronto) 905 785 0085, Canada (Vancouver) 514 685 7530, China 86 21 6555 7838, Czech Republic 420 2 2423 5774, Denmark 45 45 76 26 00, Finland 385 0 9 725 725 11, France 33 0 1 48 14 24 24, Germany 49 0 89 741 31 30, Greece 30 2 10 42 96 427, India 91 80 51190000, Israel 972 0 3 6393737, Italy 39 02 413091, Japan 81 3 5472 2970, Korea 82 02 3451 3400, Malaysia 603 9131 0918, Mexico 001 800 010 0793, Netherlands 31 0 348 433 466, New Zealand 64 09 914 0488, Norway 47 0 32 27 73 00, Poland 48 0 22 3390 150, Portugal 351 210 311 210, Russia 7 095 238 7139, Singapore 65 6226 5886, Slovenia 386 3 425 4200, South Africa 27 0 11 805 8197, Spain 34 91 640 0085, Sweden 46 0 8 587 895 00, Switzerland 41 56 200 51 51, Taiwan 886 2 2528 7227, Thailand 662 992 7519, United Kingdom 44 0 1635 523545 CVI, FieldPoint, LabVIEW, Measurement Studio, National Instruments, NI, and ni.com are trademarks of National Instruments Corporation. Product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your CD, or ni.com/patents. 1999 2003 National Instruments Corporation. All rights reserved. *322731E-01* 322731E-01 Apr03