FP-PS-4. Features. Installation

Similar documents
FP-2000/2010 FieldPoint Quick Start Guide

FieldPoint. FP-1000/1001 FieldPoint Quick Start Guide. Install the Network Module Mount the module on a DIN rail. What You Need to Get Set Up

FP-AO-210 AND CFP-AO-210

FP-AO-200 AND CFP-AO-200

TBX-96 TERMINAL BLOCK

You need the following to set up and use your terminal block:

QUICK START GUIDE. What You Need to Get Set Up

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices

cfp-rly-421 Features Installing the cfp-rly-421 FieldPoint Operating Instructions Eight-Channel SPST Relay Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9208E 16-Channel, ±20 ma, 24-Bit Analog Input Module

FP-1600 FieldPoint Quick Start Guide

NI 6521 Specifications

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9870E

INSTALLATION INSTRUCTIONS LFH160 Cable

VME-GPIB Installation and User Guide

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9871E

FieldPoint cfp-20xx. Quick Start Guide. What You Need to Get Set Up

FP-AIO-600 and cfp-aio-600

Calibrating FieldPoint Analog Input Modules with Calibration Executive

Compact FieldPoint cfp-cal

SCXI HIGH-VOLTAGE 8 4 MATRIX TERMINAL BLOCK

NI 653x Cable Adapter

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, ±10 V, 16-Bit Analog Voltage Output Module

NI SD Card Memory Module

Getting Started with the NI 8234

NI Channel, 0 20 ma, 16-Bit Analog Current Output Module

Compact FieldPoint cfp-1808

USER GUIDE SC-2075 SIGNAL CONDITIONING ACCESSORY

NI SMB-2145/2146/2147/2148

CB-27T, TBX-68T, AND CB-68T ISOTHERMAL TERMINAL BLOCKS INSTALLATION GUIDE

Getting Started with NI-Motion for NI 73xx Motion Controllers

Getting Started with the NI PCI-8254R

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 24 V Logic, Sinking Digital Input Device

DATA SHEET. Catalyst Inline Power Patch Panel

ChemiDoc and ChemiDoc MP Imaging Systems with Image Lab Touch Software Installation Qualification Protocol (IQ)

FieldPoint cfp-21xx. Quick Start Guide. What You Need to Get Set Up

Getting Started with the NI PCI-1405

NI CAN Demo Box. NI CAN Demo Box User Guide. Power supply (+9 VDC to +12 VDC) 68-pin Multifunction Data Acquisition board

Caution Electrostatic discharge can damage your controller. To avoid such damage, handle the controller only in a proper ESD-controlled environment.

NI PCIe-8255R Quick Start Guide

AC/DC (120V) Input Module Cat. No IAD Series C

Getting Started with the NI PCIe-8255R

Getting Started with the NI PCIe-8253

Getting Started with the NI PXI/PCIe-8231

Getting Started with the NI 8234

Electrical. SPECIFICATIONS SH Cable

Getting Started with the NI PCIe-1433

LabVIEW DSP Module. Contents. Introduction RELEASE NOTES. Version 1.0

Power Analyzer Firmware Update Utility Version Software Release Notes

Getting Started with R Series Multifunction RIO

Purchasing. Operations 3% Marketing 3% HR. Production 1%

Getting Started with the NI PCIe-8235

Getting Started with R Series Intelligent DAQ

USER GUIDE Universal Motion Interface (UMI)-7764

CISCO 7304 SERIES ROUTER PORT ADAPTER CARRIER CARD

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, 0 20 ma, 16-Bit Analog Current Output Module

Agilent 66000A 1200 W DC Modular Power System, GPIB

Ethernet/Serial Interfaces for Compact FieldPoint

TBX-1316 High-Voltage Attenuator Terminal Block

Instructions. (For 6180 Industrial Computers) Installing a Processor Upgrade

Keysight Technologies E3620A and E3630A Non-programmable DC Power Supplies. Data Sheet

CompactRIO Reconfigurable Embedded Chassis

Installation Instructions

FLEX Ex Spring Clamp Terminal Base

SH Cable Specifications

Installation Notes for the Catalyst 3750-X and 3560-X Switch Power Supply Modules

PRODUCT DATA. Wideband Ear Simulator Type 4195-Q for Production Line Testing of Telephones

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 24 V Logic, Sourcing Digital Output Device

Installation Instructions

Getting Results with the NI PXI-6585R

Instructions. (For 6180 Industrial Computers) Applications. Overview & Safety

Agilent U8000 Series Single Output DC Power Supplies. Data Sheet

6640A Series Single-Output, 200 W DC Power Supplies, GPIB

Getting Started with the NI PXI/PCI-1422

NI 6584R User Guide and Specifications

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9476E. 32-Channel, 24 V Sourcing Digital Output Module

Digital Pre-emphasis Processor BERTScope DPP Series Datasheet

4 GHz Active Probe P7240 Datasheet

4 GHz Active Probe P7240 Datasheet

SCC-RLY01 Relay Module

CLASS 1 DIVISION 2 PRODUCTS

IVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter

CISCO AC/DC POWER SOLUTION FOR USE WITH CISCO OPTICAL PLATFORMS

Installation Note. Removable Hard Disk Drive Upgrade Kit. For All PNA Series RF Network Analyzers. Network Analyzer Model Number

Safety. Introduction

Han R 23. Circular Connector. Certified acc. to DIN EN ISO 9001 in design/ development, production, installation and servicing.

Reconfigurable Embedded Chassis with Integrated MXI-Express (x1) MXI-Express Switch

Getting Results with the NI 5752R

NI USB-9201/9221. Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 12-Bit Analog Input Devices

INSTALLATION INSTRUCTIONS SH160F-160M-NI SwitchBlock Cable

TRC-190 User s Manual

Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

Digital Pre-emphasis Processor BERTScope DPP Series Datasheet

TRC-190 User s Manual

PRODUCT DATA. Intelligent Data Acquisition System Type 3561

SpectraGuard Sensor SS-300-AT-C-50 Technical Specifications

Cisco Aironet In-Building Wireless Solutions International Power Compliance Chart

A B A B. (Catalog Number 2707-MVH232, -MVP232) Product Data

NI 9213 Calibration Procedure

System Specifications

Transcription:

OPERATING INSTRUCTIONS FP-PS-4 FieldPoint Power Supply These operating instructions describe the installation, features, and characteristics of the FP-PS-4. Features The FP-PS-4 is a FieldPoint power supply module with the following features: 24 VDC output Convenient DIN rail mounting or optional panel mounting Universal AC power input: 90 to 264 VAC, 47 to 63 Hz Modular FieldPoint form factor for easy integration with other FieldPoint modules 15 W output for 0 to 50 C operation Installation You can mount your FieldPoint system either to a DIN rail or directly on a panel. The following sections give instructions for both mounting methods. Mounting Your FP-PS-4 on a DIN Rail The FP-PS-4 power supply module has a simple rail clip for reliable mounting onto a standard 35 mm DIN rail. Follow these steps to mount the module on a DIN rail. FieldPoint, National Instruments, NI, and ni.com are trademarks of National Instruments Corporation. Product and company names mentioned herein are trademarks or trade names of their respective companies. 323179A-01 2001 National Instruments Corp. All rights reserved. November 2001

INPUT 1. Use a flat-bladed screwdriver to unlock the DIN rail clip, as showninfigure1. 1 2 1 Rail clip locked 2 Rail clip unlocked Figure 1. Unlocking the Rail Clip 2. Attach the lip on the rear of the FP-PS-4 onto the top of a 35 mm DIN rail and press it down onto the DIN rail, as shown in Figure 2. NATIONAL INSTRUMENTS FP-PS-4 24VDC Power Supply 100-240V 47-63Hz 0.6A Max 24V @ 0.6A Max OUTPUT! Figure 2. Attaching the Module to a DIN Rail FP-PS-4 Operating Instructions 2 ni.com

3. Slide the FP-PS-4 to the desired position along the DIN rail. For maximum cooling, leave a 25 mm (1.0 in.) space between the FP-PS-4 and other devices on your DIN rail. After it is in position, lock it to the DIN rail by pushing the rail clip to the locked position, as shown in Figure 3. Figure 3. Positioning and Locking Your Module National Instruments Corp. 3 FP-PS-4 Operating Instructions

Mounting Your FP-PS-4 on a Panel Follow these steps to install the optional FieldPoint network panel mount accessory and mount the FP-PS-4 power supply module to a panel. You can order the panel mount accessory, part number 777609-01, from National Instruments. 1. Use a flat-bladed screwdriver to unlock the rail clip, as shown in Figure 1. 2. Attach the panel mount accessory to the module, as shown in Figure 4. Figure 4. Installing the Panel Mount Accessory 3. Lock the panel mount accessory into place by pushing the rail clip to the locked position. FP-PS-4 Operating Instructions 4 ni.com

4. Mount the FP-PS-4 to your panel with the panel mount accessory, as shown in Figure 5. The installation guide that comes with the panel mount accessory includes a template that you can use to drill pilot holes for mounting FieldPoint modules. For maximum cooling, leave a 25 mm (1.0 in.) space between the FP-PS-4 and other devices. Figure 5. Connecting Your FP-PS-4 to the Panel Connecting Power to Your FieldPoint System Caution Before you connect the FP-PS-4 to your FieldPoint system, make sure the power cord is not pluggedintoanelectricaloutlet. Each FP-PS-4 provides a 24 VDC output. You decide the number of FP-PS-4 modules you need in your bank based upon the specific power and isolation requirements. The total power of all of the FieldPoint modules and other devices connected to an FP-PS-4 cannot exceed the specified output for the temperature range at which you are using FP-PS-4. For FieldPoint power requirement details, refer to the operating instructions for your particular I/O modules. Decide how you want to power your FieldPoint bank based on the power requirements of your bank and your isolation National Instruments Corp. 5 FP-PS-4 Operating Instructions

needs. Select one or a combination of the methods to power the signals of each of your I/O modules: The signals of the I/O module are powered by an FP-PS-4 that is connected to only that I/O module. The signals of the I/O module share an FP-PS-4 with a neighboring I/O module or network module. This is called cascading power. Caution Cascading power from neighboring bases or network modules defeats isolation between cascaded modules. Figure 6 shows a combination of the two ways to power the FieldPoint bank. FP-2000 FP-AO-200 FP-RLY-420 FP-DO-400 FP-PS-4 Bank 15 16 V V 1 2 3 31 32 C C 17 18 CAUTION: Cascading power defeats isolation. Figure 6. Wiring Power to Your FieldPoint Bank In Figure 6, the FP-PS-4 bank provides the power using both of the methods mentioned previously. The FP-2000 and FP-AO-200 have their own power supplies. Isolation is maintained because the FP-AO-200 has its own power supply. The FP-RLY-420 and FP-DO-400 share a power supply, which provides enough power, but defeats isolation between the signals of those two modules. FP-PS-4 Operating Instructions 6 ni.com

Ensure that all the wiring is installed according to local codes and regulations by qualified electrical personnel. Follow these steps to connect the FP-PS-4 to your FieldPoint system. 1. Use a 16 to 26 AWG stranded wire to connect the FP-PS-4 to your FieldPoint network module or I/O module. Connect the positive wire to the V terminal and the negative wire to the C terminal of the FP-PS-4. 2. Connect the other ends of the wires to the V and C terminals of the FieldPoint network module or I/O module. 3. Ensure that the plug-in AC input terminal connector is plugged into the input port on the FP-PS-4. Note Be careful to install the correct conductor in the appropriate terminal. The color of the conductor wires varies depending on North American versus international standards as described in Figure 7. The wires are drawn to scale according to the 7 mm (0.275 in.) strip length requirement. 4 1 L N 2 3 1 Line wire (black by North American standards; brown by international standards) 2 Neutral wire (white by North American standards; blue by international standards) 3 Ground wire (green by North American standards; green/yellow by international standards) 4 Plug-in AC input terminal connector Figure 7. Conductor Wire Color Standards for the Plug-in AC Input Terminal Connector 4. Connect the black or brown conductor into the line terminal labeled L. 5. Connect the white or blue conductor into the neutral terminal labeled N. National Instruments Corp. 7 FP-PS-4 Operating Instructions

6. Connect the green or green/yellow conductor into the ground terminal. Caution When you install the conductors, make sure that the entire conductor is in the screw terminal and that there are no loose strands outside of the terminal. Only install one wire in each terminal. Specifications The following specifications are typical for a range of 0 to 60 C, unless otherwise noted. Installation Terminal wiring...16-26 AWG copper conductor wire with 7 mm (0.275 in.) strip length as showninfigure8 7mm Figure 8. ConductorWirewiththeCorrectStripLength(drawingistoscale) Torque for screw terminals...0.5-0.6 Nm (4.4 5.3 in.-lbs) Input Characteristics Input voltage...90 264 VAC Frequency...47 63 Hz, single phase Maximum current consumption...0.6 A at 120 VAC, 60 Hz Input protection...nonreplaceable internal AC fuse Output Characteristics Output voltage...24 VDC, nonadjusting Nominal current (I N )...600 ma Nominal continuous power 0to50 C...15 W 50 to 60 C...10 W FP-PS-4 Operating Instructions 8 ni.com

Overload protection...protected against short circuits and output overload Physical Indicator...Green DC POWER LED Weight...300 g (10.5 oz) Environmental FieldPoint modules are intended for indoor use only. Operating temperature 15 W operation...0 to 50 C 10 W operation...50 to 60 C Storage temperature... 40 to +85 C Humidity...10 to 90% RH, noncondensing Maximum altitude...2,000 m Pollution degree...2 Safety Do not operate FieldPoint products in an explosive atmosphere or where there may be flammable gases or fumes. If you need to operate FieldPoint products in such an environment, the FieldPoint products must be in a suitably rated enclosure. The FP-PS-4 meets the requirements of the following standards for safety and electrical equipment for measurement, control, and laboratory use: EN 61010-1:1993/A2:1995, IEC 61010-1:1990/A2:1995 UL 3121-1:1998 CAN/CSA C22.2 no. 1010.1:1992/A2:1997 Electromagnetic Compatibility CE, C-Tick and FCC Part 15 (Class A) Compliant Electrical emissions...en 55011 Class A at 10 m FCC Part 15A above 1 GHz Electrical immunity...evaluated to EN 61326: 1997/A1: 1998, Table 1 Note For full EMC compliance, you must operate this device with shielded cabling. See the Declaration of Conformity (DoC) for this product for any additional National Instruments Corp. 9 FP-PS-4 Operating Instructions

regulatory compliance information. To obtain the DoC for this product, click Declaration of Conformity at ni.com/hardref.nsf/. Mechanical Dimensions Figure 9 shows the mechanical dimensions of the FP-PS-4. Dimensions are given in millimeters [inches]. 107.19 [4.22] 109.5 [4.31] 91.44 [3.60] Figure 9. Mechanical Dimensions FP-PS-4 Operating Instructions 10 ni.com

Where to Go for Support For more information about setting up your FieldPoint system, refer to these National Instruments documents: Your FieldPoint network module user manual Your other FieldPoint I/O module operating instructions Your FieldPoint terminal base operating instructions Go to ni.com/support for the most current manuals, examples, and troubleshooting information. For telephone support in the United States, create your service request at ni.com/ask and follow the calling instructions or dial 512 795 8248. For telephone support outside the United States, contact your local branch office: Australia 03 9879 5166, Austria 0662 45 79 90 0, Belgium 02 757 00 20, Brazil 011 284 5011, Canada (Calgary) 403 274 9391, Canada (Montreal) 514 288 5722, Canada (Ottawa) 613 233 5949, Canada (Québec) 514 694 8521, Canada (Toronto) 905 785 0085, China (Shanghai) 021 6555 7838, China (ShenZhen) 0755 3904939, Czech Republic 02 2423 5774, Denmark 45 76 26 00, Finland 09 725 725 11, France 01 48 14 24 24, Germany 089 741 31 30, Greece 30 1 42 96 427, Hong Kong 2645 3186, India 91805275406, Israel 03 6120092, Italy 02 413091, Japan 03 5472 2970, Korea 02 596 7456, Malaysia 603 9596711, Mexico 001 800 010 0793, Netherlands 0348 433466, New Zealand 09 914 0488, Norway 32 27 73 00, Poland 0 22 528 94 06, Portugal 351 1 726 9011, Russia 095 2387139, Singapore 2265886, Slovenia 386 3 425 4200, South Africa 11 805 8197, Spain 91 640 0085, Sweden 08 587 895 00, Switzerland 056 200 51 51, Taiwan 02 2528 7227, United Kingdom 01635 523545 National Instruments Corp. 11 FP-PS-4 Operating Instructions