DCS Digital Control Expansion System

Similar documents
CERBERUS. Cerberus multi I/O. Datasheet. Shaping the future of sound reinforcement. Cerberus. Applies to Part Number:

SEL-710 Motor Protection Relay

RCM-810. Technical specifications. Electro-Voice RCM-810. Enable powerful control and supervision capabilities

PLCADD1616 User Guide 3/29/10. Overview

SEL-700G Generator and Intertie Protection Relays

AR-IPC14P Industrial PC Chassis

Rotary Measurement Technology Absolute Encoders, Singleturn

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

Series 200. Hardware Platform

MOTION COORDINATOR MC403 / MC403-Z Quick Connection Guide

Rotary Measurement Technology Absolute Encoders, Multiturn

MASELEC MTC-6 master transfer and monitor system

Chapter. Getting Started. In This Chapter...

N8000. Electro-Voice N8000. Full IRIS-Net Software Support. 32-Channel Digital Matrix Bus. 115 db Dynamic Range

PILOT TONE DETECTION MODULE IMPEDANCE DETECTION MODULE

Description. Monitoring functions Evaluation of brush length monitoring, digital, non-floating A00

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

INTEGRUS BOSCH DIGITAL INFRA-RED LANGUAGE DISTRIBUTION SYSTEM. Installation and Operating Manual

Applications Guide & Getting Started Manual

INTEGRUS. LBB 3222/04 6-Channel Interpreter Desk with Loudspeaker. LBB 3422/20 Integrus Audio Input and Interpreters Module

Stepnet. Module. Provides Mounting & Connections for Stepnet Module CANopen Stepping Motor Driver DEVELOPMENT KIT

Model SAP612 Source Assign Panel User Manual

Features. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Output Connectors. Overvoltage Protection. Over Temperature Protection

USER MANUAL. SL-10 Master Room Controller MODEL: P/N: Rev 4

AirTest Model CN9000 Series Sensor Controller

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-74DL Master Room Controller. P/N: Rev 5

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

ControlSpace ESP-1240 TECHNICAL DATA SHEET. engineered sound processor. Key Features. Product Overview. Product Information.

ControlSpace ESP-1240 TECHNICAL DATA SHEET. engineered sound processor. Key Features. Product Overview. Product Information.

Installing Sentor. Hardware Installation

Electronic SD1, AS 8, ASR 14, ASR 20

CREATING YOUR OWN RF SWITCHING SYSTEM

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

S-Band Redundant LNA Systems

MOTION COORDINATOR MC405 Quick Connection Guide

Chapter. Specifications: In This Chapter...

Features. Conducted Emission. Radiated Emission. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors.

CLOUD CX261 Single Zone Mixer

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

Features. Conducted. Emission. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Overvoltage Protection. Phase Loss.

1280 Enterprise Series Programmable Color Touchscreen Weight Indicator/Controller

USER MANUAL. RC-74DL Master Room Controller MODEL: P/N: Rev 4

Professional Audio Conferencing Products - CONVERGE Pro 2 Series

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

Slick Line Acquisition System Manual

Prisma II Platform. Optoelectronics

RTK4 Logic Controller User Manual For RTK4L Revision Revised

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

CSI 6300 SIS Overview

LASER PLUS OPERATING INSTRUCTIONS

DATA SHEET: Wall Panels

Data sheet CC 03, Commander Compact (603-1CC21)

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

MINI MCR-SL-UI-REL(-SP)

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL

~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

DRTS 33. The new generation of advanced three phase relay test set

M A C 3 Wind Speed Alarm & Controller

Interconnect, Passive and Electromechanical Elements

AS-i 3.0 Motor modules

(9) (0.354) (7.5) (10) A+B+C+D dimensions (mm in) Control unit

TOA ELECTRIC CO., LTD.

BU400,BU400B,UB400B, UB400B, & BI400

508 SERIES MICROPHONE STATIONS

AB-315. ibus Wall-Dock for A-Bus Audio Systems

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

K ROMA T E L E C O M

Modular Block Converter Systems

AUTROVOICE MULTIVES EXCHANGEABLE MODULES

Analog Current Input - 16 Channel IC693ALG223. Current Ranges. Power Requirements and LEDs. Location in System. Analog Input Modules

Electronic Multi-channel Load PMLA. 150 W / 600 W 40 V up to 240 V 1 A up to 120 A. Preliminary Edition

JUMO TYA 201 Single-Phase SCR Power Controller For controlling resistive/inductive loads

USER GUIDE TEHR LU / TEHR-M

List of Components Versions for Safetec SFT-9000 systems

Model # Description Price

HXV SERIES HIGH VOLTAGE SWITCHING SYSTEMS

VIPEDIA-12. Cameo specification sheet. Product Description

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

PC2004 PRESSURE CONTROLLER

Network audio encoder / decoder with I/O for professional and broadcast applications

ELECTROMECHANICAL SWITCH MATRICES

P3-RS Remote Slave Module

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

INSTALLATION AND OPERATING INSTRUCTIONS. Lightgate MixedWhite Touchpanel TP-MW-01/W/WM/NFC

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01

TIME DELAY RELAYS TD-7 Series Time Ranger TM Digital-Set Programmable Multi-Range Plug-in

4.2 Expansion Modules MAC00-B1/B2/B4

I / O Expander. Instrument for torque control ASL 11/17

Rotary Measuring Technology Absolute encoders, Singleturn, Profibus-DP

STUDIO 1800 OPERATING INSTRUCTIONS MANUFACTURED IN THE UK

PROGRAMMABLE MULTI-FUNCTION

Blue Point Engineering

MAC3 Wind Speed Alarm & Controller. Installation Instructions

GIN-SAM4. Hardware User Manual. Version: 1.02 Date: Language: English

HPA4202 1/5. 2-Channel High Power Multi-Impedance Amplifier. General Description. Features. Applications. AtlasIED.com. HPA4202 Front.

Climatix TM Climatix Controller. For controlling, switching and monitoring functions

DF PROFI II PC/104-Plus

Data sheet FC-9 DSP system controller. Amp Contoller-Series DSP-Amplifiers + DSP-Controller.

8/16 Passive Switcher

SoundwebTM. Installation Guide

Transcription:

S Digital ontrol Expansion System 4 position Phoenix type connector for power supply. 2 LED s on the front indicating power. Internal backplane with system bus. Internal self-resetting fuses. General Description: S 400 Series modules increase the Pronnounce system's control capabilities in many ways. The S system can be expanded at any time after installation for increased functionality. The S control system consists of the following components: S 400 main module chassis S 401R primary system control module. S 405R extension module. S 408R relay module. S 409R relay module. S 412R logic input module. S 416R analog I/O module. S 420 monitor unit. The Pronnounce operating system defines the total amount of supported control inputs and outputs. Pronnounce installation allows integrating a maximum of up to 8 S 401R control modules. single control module can host up to 12 relay boards of the types S 408R / S 409R in any sequence. In addition, it is possible to connect up to 5 logic input modules, 2 analog I/O modules, and 2 rotary encoders. In total, the Pronnounce system can manage up to following amounts of different S cards: 8 S 401R control modules. 48 S 408 / S 409 relay modules. 10 S 412 logic input module. 8 S 416 nalog I/O module 1 S420 Monitor Unit S 400 19 RK FRME The S 400 is a 19 base unit with a height of 2 HU. It can host a control module as well as several relay modules, logic input modules, and analog I/O modules that are connected via internal backplane. 10 slots for the insertion of S modules. S 401R ONTROL MODULE The module represents the interface for relay boards, logic boards, analog level I/O-boards, a monitor module, and rotary encoders. It is inserted into slot 1 (the slot all the way on the left) on the rear of the S 400 rack frame. It is controlled from the DPM 4000 via RS-485 remote interface. Maximally 12 relay modules (S 408R / S 409R / S 408 / S 409), 5 logic input modules (S 412R, S 412), 2 analog I/O modules (S 416R / S 416), 2 rotary encoders and 1 monitor module S 420 can be connected to a single S 401R control module. Two RJ-45 sockets for connecting the DPM 4000 and cascading several S 401R or S 401 modules. Galvanic isolated RS-485 port. onnector for 2 rotary encoders. onnector for S 420 monitor module. Monitoring via watchdog circuitry. Service-functions and testing-software for all connected modules. 6 binary switches for setting addresses and selecting service-functions 1 pen-tip pushbutton test start. 3 LED s - red, yellow, green for test mode and status. maximum amount of 8 modules S 401R or S 401 can be cascaded. Operating voltage 24 V, -10 / +30% Operating current 25 m to 65 m Operating current at 24 V 35 m Operating temperature range +5 to +40 Weight 207 g

S 405R EXTENSION MODULE The module is used to provide connection to another S 400 rack frame and /or other S 400 boards. This is useful in situations where there are more cards on a given S 401R than a single S 400 frame can support. Installation Notes In the first S 400 rack frame the S 405R extension module always needs to be installed in the first empty slot (the slot right of any other modules installed). In the S 400 extension unit the second unit installed the S 405R extension module always needs to be installed in slot 1 (the slot all the way on the left, instead of the S 401R). Operating temperature range +5 to +40 Weight 115 g S 406R SHIELDING MODULE The module is meant for insertion on the rear of the S 400 rack frame providing shielding between S 408R and S 409R modules. Dimensions (W x H x D) 37.5 x 80.6 x 245 mm Weight 71 g S 407R ONTROL RELY MODULE The module provides switching for audio signals (line level) or control outputs independent from the S 400 system. 4 LF-relays, each with 2 SPDT switching contacts. Gold-plated double-contacts for improved contact. Phoenix type connector for all contacts and coils. 4 relay control-led s. onfiguring the audio distributor is possible through separating wirebridges. Switchable monitor bus link. Operating voltage 24V, -10% / +30% Operating current, all relays on 37 to 54 m Operating current, all relays on at 24 V 42 m Operating temperature range +5 to +40 Weight 163 g Relay ontacts: ontacts DPDT ontact material gpd + 10µ u ontact load (real) 1 / 24V, 0.5 / 120V ontact current max. 2 S 408R / 409R ONTROL RELY MODULES These modules provide relay contact closures for use in switching audio or other control functions. The 408R is capable of switching of 70v or speaker lines. The 409R is capable of switching line level audio signals or control outputs. The 408R can also be used to provide contact closures where higher voltages and/or current may be involved. 5 line relays, each with 2 switching contacts. Phoenix type connector for all contacts. 5 relay control-led s. onfiguring the signal distributor is possible through separating wire-bridges. 12 S relay modules can be cascaded. Operating voltage 24V, -10% / +30% Operating current, relays off 5.2 m to 7.8 m Operating current, relays off at 24 V 5.5 m Operating current, all relays on 55-130 m Operating current, all relays on at 24 V 60-96 m Operating temperature range +5 to +40 Weight 225 g Relay ontacts: ontacts DPDT ontact material gni 90/10 ontact load (real) 408R-2000 V, 409R-1

S 412R LOGI INPUT MODULE The module provides inputs for control lines, pushbuttons, switches, and sensors, allowing the evaluation of their individual status (ON / OFF) in the DPM 4000 system. 12 inputs. Selectable polarity of each input. Floating inputs can be realized via the separation of wire bridges. Separate connections for power supplies of pushbuttons, contacts and sensors. Phoenix type connector for all inputs. Maximally 5 S412R / S412 modules can be cascaded. Operating voltage 24V, -10 / +30% Operating current, all inputs open 2.6 m to 8.2 m Operating current, all inputs at 24V 60 m to 83 m Operating temperature range +5 to +40 Weight 175 g Input Level: Input voltage for off (Low) UIN < ±5 V Input voltage for on (High) UIN > ±10 V Input current at UIN = 24 V IIN = 4.8 m Input voltage max. UIN max = ±31 V Output source voltage 24V Output source current max. 90 m S 416R NLOG I/O MODULE The module provides analog input and output interfacing capabilities for use in monitoring and control functions. oth inputs and outputs are capable of handling 0 to 10V with 256 distinct levels. Potentiometers for volume control can be interfaced using the provided reference voltage output. 8 analog inputs. Voltages of 0 to 10V or a potentiometer to each input. Output for reference voltage 10V. 8 analog outputs 0 to 10V. Phoenix type connector for all inputs and outputs. Maximally 2 S 416R / S 416 modules can be cascaded. Operating voltage 24V, -10 / +30% Operating current (max.) 160 m Operating temperature range +5 to +40 Weight 170 g Inputs: Voltage range (min. to max.) 0 V to 10 V Impedance range ext. (min. to max.) 0 to10 kohm Maximum input voltage 50 V Outputs: Voltage range (min. to max.) 0 V to 10 V Output impedance 47 Ohm Maximum load 2k Ohm Resolution of Inputs / Outputs 8 it Reference output voltage 10 V Reference output current 30 m (max.) S 420 MONITOR STTION The S 420 Monitor Manager is a 2RU unit offering acoustic control and visual level metering of audio in the system. Switching and displaying of up to 250 audio signal sources, as well as, controlling the volume is carried out via front panel control switches. THE S420 receives its audio feed from the monitor output of the DPM4000. S420 system control functions are carried out through a connection to the S401 controller module. The front panel controls of the S420 offer audio level and line control switching of either the input signal or the output signal of the system amplifiers. With several external sound sources connected, switching is performed through the S 409R module. When using remote-amplifiers, switching audio signals to the monitor bus is accomplished directly inside the amplifier. The signals are transmitted via remote interconnection cables

rchitecture & Engineering The expansion system is designed for use with the Pronnounce system and shall enable the use of a variety of system control and output routing devices. The system shall consist of a 2RU system rack frame accommodating any one of a series of 6 expansion control modules, which slide in the rear of the unit. The rack frame shall hold up to 10 expansion cards. It shall be powered from a 24V source supply through a dual spade lug terminal connection. The system shall be equipped with internal self-resetting fuses. The system shall enable the use of analog or digital controls; expand the system operation to include relay operated switching and remote monitoring. The system shall also offer the ability to add a rack mounted monitor unit for in place control and monitoring of any channel. The expansion system shall be the Dynacord Pronnounce S digital control system. vailable ccessories: Model at. No. Description NRS90240 121742 Volume Shaft Encoder Ordering Information: Model at. No. Description S420 121753 Monitoring Unit S400 121773 19" Frame for S Modules S401R 121774 ontroller Module S405R 121775 Extension Module S406R 121776 Shield Module S407R 121777 F-Relay Module w/ext ontrol S408R 121778 Lines-Relay Module S409R 121779 F-Relay Module S412R 121780 Logic Input Module S416R 121782 nalog I/O Module lock Diagrams:

lock Diagrams: DPM4000 or S401 N2 DPM4000 or S401 N1 1 1 RS485 +5V Reset Watch dog PU EPROM SRM EEPROM S416 N9 S401-ddress S1 S412 N8 INIT S2 S408/9 N7 LED1 Test TP1 2 x Rotary Encoder N12 LED2 KL N4-24V KL t D +5V LOKDIGRM S 401 1 N3, N5

lock Diagrams:

lock Diagrams: EN DT LK Input 12 Input 11 Input 10 P/S Input 9 R14 R13 Input 8 Input 7 Input 6 Input 5 Input 4 Input 3 Input 2 Input 1 t LOK DIGRM S 412 EN P/S ID DT t +5V LK N9 N N6 N10 OUT -24V OUT OUTPUT N7 INPUT N8 KL -24V KL N -24V N DT EN Output +18V 10V Ref +18V LK DT D/D EN RES P SEL EN MONITOR EN P SEL DT P SEL RES P SEL Output 1 0...10V +18V Output 8 0...10V D S Q D S Q +5V Q R Q R EN Input 1 0...10V +5V DT N +18V DT D/D LK EN N -24V N D N8, N9 +5V DT P SEL EN P SEL EN MONITOR N +5V +5V +18V Ident +5V +18V +5V t oard select Input 8 0...10V +5V S416 lock Diagram N10 OUTPUT N13 INPUT N7 KL -24V KL

lock Diagrams: RESET EN P/S EN S/P P/S ID DT DT LK RESET EN P/S Relay Driver EN S/P r a r a r a r a r a r a r a r a r a r a Input 5 N13 Output 5 N12 Input 4 N11 Output 4 N10 Input 3 N9 Output 3 N8 Input 2 N6 Output 2 N7 Input 1 N5 Output 1 N4 LOK DIGRM S 408 S/P DT DT LK N t +5V N3 N15 OUTPUT N2 INPUT N1 KL -24V KL r a r a r a r a r a r a r a r a r a r a Input 5 N13 Output 5 N12 Input 4 N11 Output 4 N10 Input 3 N9 Output 3 N8 Input 2 N6 Output 2 N7 Input 1 N5 Output 1 N4 LOK DIGRM S 409 RESET EN P/S EN S/P P/S ID DT DT LK RESET EN P/S Relay Driver EN S/P S/P DT DT LK N t +5V N3 N15 OUTPUT N2 INPUT N1 KL -24V KL 12000 Portland v. South, urnsville, MN 55337 Phone: 952-887-4051, Fax:952-887-0043 www.electrovoice.com Telex ommunications Inc 11/2002 Part Number 38109-xxx Rev US and anada Only. For customer orders contact ustomer Service at: 800/392-3497 Fax: 800/955-6831