Version 1.26 Installation Guide for On-Premise Uila Deployment Table of Contents Introduction... 2 Scope and Purpose... 2 Architecture Overview... 2 Virtual Architecture... 2 Getting Started... 3 System Requirements... 3 Deploy Uila Management and Analytics System... 6 Deploy Virtual Information Controller (vic)... 11 Deploy Virtual Smart Tap (vst)... 16 Contact Uila Support... 19 About Uila... 19
Introduction Scope and Purpose This document describes the system requirements, installation and configuration steps for the Uila Virtual Information Controller(vIC) and Virtual Smart Tap(vST). It is assumed that the reader has already installed VMware and is familiar with the configurations and operations of VMware. Architecture Overview The diagram below shows the Uila Management and Analytics System architecture(umas) and its relationship to Virtual Information Controller(vIC) and Uila Virtual Smart Taps(vST). Virtual Architecture The Uila Management and Analytics system(umas) is a big data store and analytics engine that is designed to monitor up to thousands of servers. The UMAS can record data in minute resolutions while maintaining real time responsiveness. The built-in redundancy offers high availability, removes downtime and reduces maintenance overhead. The Virtual Information Controller (vic) integrates to the VMware vcenter. The vic is deployed as a guest VM where it collects network, storage and compute performance metrics that are 2 Uila Confidential 2017 Uila On-Premise Installation guide v1.26
maintained by the vcenter. This is then combined with the data from the Virtual Smart Taps(vST) and transmitted to the UMAS. Virtual Smart Taps (vst) are also deployed in the host as an efficiently designed small foot-print guest VM with embedded Deep Packet Inspection (DPI) technology to identify unique applications and their attributes. vst s measure application response time and collect network performance data. The vst does not examine or store the packets, thus eliminating the risk of exposing sensitive data. Getting Started System Requirements UMAS can be installed as a Virtual Machine directly on a server that has VMware ESXi installed. The table below shows the minimum specifications required to install UMAS. Scope # of VM Monitored vcpu (Cores) Virtual Memory Local or Direct Storage Small 0 ~ 250 VM 1(4) 24 GB 400 GB Medium 250 ~ 500 VM 1(4) 36 GB 800 GB Large 500 ~ 1000 VM 2(8) 64 GB 1.6 TB Internet Browser for your monitoring console: o Firefox, Chrome on Windows platform o Safari, Firefox, Chrome on OS X platform o Firefox, Chrome on CentOS, Ubuntu Linux platform VMware version requirements: o vsphere ESXi 5.x or higher o vcenter Server 5.x or higher Uila Virtual Smart Tap(vST) requirements: o Each of the hosts monitored requires one vst installed as a guest VM, with average single vcpu usage of 70 MHz, and Monitor Port Group average 200 kbps bandwidth, pre-allocated o 1Gb memory required during installation and 500 Mb in run time o 2Gb disk space required during installation and 500 Mb in run time 3 Uila Confidential 2017 Uila On-Premise Installation guide v1.26
Uila Virtual Information Controller (vic) requirements: o Installed as a guest VM with single vcpu average usage of 275 MHz and Monitor Port Group average of 400 kbps network bandwidth vic s virtual resource allocation (depending on # of VM s monitored) is listed in Table below: Scope # of VM Monitored vcpu Virtual Memory Local Storage Small 0 ~ 500 VM 2 Cores 4 GB 8 GB Medium 501 ~ 1,000 VM 2 Cores 8 GB 8 GB Large 1,001 ~ 2,000 VM 2 Cores 16 GB 8 GB Proper vcenter access rights are required for vic to collect information such as CPU, memory and storage metrics from vcenter. The access rights must be able to make configuration changes, deploy and setup Uila vst VM. You must have one of the two options pre-configured before vic deployment: 1. Full administrative access rights (vcenter administrator role), or 2. Partial administrative access rights with the following table of privileges enabled. Privilege Categories Datastore Allocate space Browse data store Remove file Privilege Items Global Cancel task Host Local operations->create virtual machine Local operations->delete virtual machine Network Assign network Resource Scheduled task Assign virtual machine to resource pool Modify resource pool Create tasks Modify tasks Remove tasks Run task 4 Uila Confidential 2017 Uila On-Premise Installation guide v1.26
Virtual machine dvport group vapp Configuration Guest Operations Interaction Inventory Provisioning Service configuration Snapshot management vsphere replication Create Delete Modify Add virtual machine Assign resource pool Assign vapp Import Network requirement o Allocate one IP address for each of the vst s. This can be either static IP address or assigned via DHCP, prior to the deployment. o Allocate one static IP address for the vic prior to deployment. o Allocate one static IP address for the UMAS deplyment o Open TCP and UDP ports to allow communications between Uila sub-systems as illustrated in the chart below. Unblock TCP ports 5000 and 443 between vic and the UMAS. Unblock TCP ports 443 and 902 between vic and Hypervisor hosts Unblock UDP port 8000 between vic and vst 5 Uila Confidential 2017 Uila On-Premise Installation guide v1.26
Deploy Uila Management and Analytics System This section describes the step-by-step instruction to download, install and activate UMAS. 1. An email with instructions to download UMAS and vic will be provided by a Uila Support staff. The files are.ova templates that can be deployed onto vcenter. 2. Login to vcenter using the vcenter client. 3. Deploy UMAS ova in vcenter. 4. Browse to locate UMAS ova file 6 Uila Confidential 2017 Uila On-Premise Installation guide v1.26
5. Verify ova template details 6. Specify a name and location for the deployment template 7. Select the host/cluster location where the UMAS is to be deployed. 7 Uila Confidential 2017 Uila On-Premise Installation guide v1.26
8. Select the datastore for the UMAS VM 9. Select disk format to be thin provisioned for more efficient usage of storage space. 8 Uila Confidential 2017 Uila On-Premise Installation guide v1.26
10. Network mapping Select a network port group where the UMAS can communicate with the vic. 11. Enter UMAS properties o Enter the administrator login ID and password. o Enter the vcenter IP/hostname along with its username and password. 9 Uila Confidential 2017 Uila On-Premise Installation guide v1.26
o Enter the UMAS assigned IP address along with gateway, DNS and subnet information. 12. Review all the settings and click finish. 13. Once the system is deployed, power on the UMAS. Depending on the VMware environment this process may take several minutes. 14. Please open the VM console to monitor the progress of the UMAS. If a blue screen like the image below appears, the VM is powered on 10 Uila Confidential 2017 Uila On-Premise Installation guide v1.26
Now proceed to install the Virtual Information Controller (vic). Deploy Virtual Information Controller (vic) This section describes the step-by-step instruction to download, install and activate vic. 15. Deploy vic.ova in vcenter 16. Browse to locate the vic.ova file 11 Uila Confidential 2017 Uila On-Premise Installation guide v1.26
17. Verify OVA template details 18. Review and accept Uila end user license agreement 19. Choose name and folder location 20. Select Uila deployment configuration, wither small, medium or large depending on the number of VM s in the environment. 12 Uila Confidential 2017 Uila On-Premise Installation guide v1.26
21. Choose the cluster and host 22. Select the datastore for the vic 23. Select disk format to be thin provisioned for more efficient usage of storage space. 13 Uila Confidential 2017 Uila On-Premise Installation guide v1.26
24. Network mapping Select a network port group where the vic can communicate with the vst and the UMAS. 25. Enter the vic properties For server name/ip address, enter the UMAS IP assigned Enter the login ID and password created during Uila registration. 14 Uila Confidential 2017 Uila On-Premise Installation guide v1.26
Enter the vcenter IP/hostname along with its username and password. Enter the vic assigned IP address along with gateway, DNS and subnet information. 26. Review all the settings and click finish. 27. Once the system is deployed, power on the vic. Depending on the VMware environment this process may take several minutes. 28. Please open the VM console to monitor the progress of the vic. If a blue screen like the image below appears, the VM is powered on 15 Uila Confidential 2017 Uila On-Premise Installation guide v1.26
Now proceed to install the Virtual Smart Tap (vst) Deploy Virtual Smart Tap (vst) This section describes a step-by-step instruction to deploy vst. 1. Login to Uila portal. The portal can be accessed by entering the IP address/hostname of UMAS server on the web browser. 2. If an orange button lights up, the vic is able to communicate with the UMAS. Click on the orange button to start vst deployment. 16 Uila Confidential 2017 Uila On-Premise Installation guide v1.26
3. Click on Settings and then vst configuration 4. Click Install and select configuration options for the vst. 17 Uila Confidential 2017 Uila On-Premise Installation guide v1.26
5. Once correctly installed, the vst status will show up with a green Active 6. Install additional vst s by following steps 4 and 5. 7. Verify dashboard to see data on timeline is being populated. 18 Uila Confidential 2017 Uila On-Premise Installation guide v1.26
Contact Uila Support Uila software solutions are designed with ease of installation and simplified maintenance in mind. The Uila team is dedicated to exceeding your expectations, and knows that any downtime is too much in today's competitive world. Our goal is to keep your applications running 24 X 7. We offer a simple and effective support program to meet your needs. Customers who purchased Uila products and under support contract will receive the following benefits: Unlimited support via email or phone call Free software minor release update Free software major release upgrade Email: support@uila.com Phone: (408) 819-0775 About Uila Uila gives IT infrastructure teams x-ray vision for their data center operations and end user experience. Designed for Private, Public and Hybrid Cloud environments, Uila s Application- Centric Data Center Infrastructure Monitoring and Analytics provide instant visibility into hotspots and bottlenecks in any data center. Uila provides service dependency mapping, full stack correlation with 1-click root cause analysis and patented deep packet inspection technology that understands over 2,700 application protocols for transactional meta data analysis. Businesses use Uila to align themselves with their IT Operations team and cut time to resolution from days to minutes, keep their application at peak performance at all time and ensure end-user satisfaction to the fullest. 19 Uila Confidential 2017 Uila On-Premise Installation guide v1.26