MAINS DISTRIBUTION UNIT MDU14-CO

Similar documents
Tallyman Controller Quick Configuration Manual

The TSL Tally and UMD Configuring Program. Power Supply PSU-22 this section is intended to be read in conjunction with the Introduction

MAINS DISTRIBUTION UNIT MDU12-PM

MAINS DISTRIBUTION UNIT MDU12-PA 12 Way Power Alert

TM1 MK2 and TM1+ MK2 Installation Manual (SN on)

AMU1-CHD+MK2 AUDIO MONITORING UNIT

Television Systems Limited. Vanwall Road, Maidenhead, Berkshire, SL6 4UB Telephone +44 (0) , FAX +44 (0)

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

Wireless DMX Transmitter/Receiver/Splitt Instruction Manual

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

ME3 Mobile Cabinet Three Phase Frequency Converter, Operation and Maintenence.

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

Installation Instructions

SoundwebTM. Installation Guide

Neutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A

DST8-DIN 8-way DMX Splitter Instruction Manual

Displays: UMDs and IMD (In Monitor Display) this section is intended to be read in conjunction with the Introduction

SMARTSCAN INFORMATION

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

LF1-400 Frequency Converter, Operation and Maintenance

LF3-400 Three Phase Frequency Converter, Operation and Maintenance.

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

AVC 2 AUTOMATIC VOLUME CONTROL USERS MANUAL

Installation Manual for D1800 Series High Power PoE Midspan Power Supply

Model HM-535 Power Supply Installation and Service Instructions

BlueWave ~ Intelligent Energy Control. Installation and User Manual for BW2/C and BW3/C versions. Quick Guide

Ether-Lynx User s Guide

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

MODEL 805 USER MANUAL

Installation and Operating Handbook. ICLH Combiner ISLH Splitter

Hoist Controller for Direct Voltage Hoist Instruction Manual

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

STUDIO 1800 OPERATING INSTRUCTIONS MANUFACTURED IN THE UK

IS Series Manual. 19 Pro Series Rack Mount (RK) Faceplate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) colours

Hoist Controller for Low Voltage Hoist Instruction Manual

DST 4-way DMX/AC Power Splitter Instruction Manual

DMX Switch Pack Instruction Manual

PAT-Cal 2 TECHNICAL MANUAL

Product Manual ASL Document Ref.: U doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23

Hoist Controller for Low Voltage Hoist

Panel Installation Datasheet

Leased-Line Extenders over IP

IT power distribution Power distribution units (PDU) Basic. Versions available:

Vigil 3 Amplifiers. Installation Instructions

Power supply. Phases: 3. Short-circuit capacity 10 ka AGS

GS400. Electronic Auto-Ranging DIN Panel Mounted Positioner

XES-8G 8-Port Gigabit Ethernet Switch User Manual

Metro-Optical Transport Access Nodes

APT20. User Manual.

Power supply module, bus connection module

Safegard V4 Panel. Installation Datasheet. Safegard V4 Panel Installation Instructions and Datasheet release 1.7 August 2016

Hoist Controller for Low Voltage Hoist Instruction Manual

LED W RGBA User Manual

Digital Room Thermostat

Thermoelectric Cooler Controller TED1000

Operating Instructions

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES

NI PXI-1042 Series Power Supply Shuttle

Installation and Operating handbook. RCU50 Redundancy unit with Waveguide switch Control

XPD-28 2:8 DMX & RDM Splitter User Manual

MC 11 EB-2 Power supply cabinet with external bus, AC version

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

DEEP SEA ELECTRONICS PLC

User Guide. Target System Power Amplifier Module

DEEP SEA ELECTRONICS PLC

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Operating Instructions

Operating instructions. Standstill monitor A / / 2011

THIS PAGE LEFT BLANK

Series MV2000 MEDIUM VOLTAGE HIGH CURRENT POWER SUPPLIES

LASERMET ULTRA LED SIGNS INSTRUCTION MANUAL. Single Aspect Illuminated Sign LEDS-ULT-790

Data Manager Installation Guide

T L Audio INDIGO SERIES. User Manual PA-2001 VALVE PRE-AMPLIFIER. Tony Larking Professional Sales Limited, Letchworth, England.

E-ACLM-V E-ACLM-P12/8/18 AC LINE MONITORS Installation and Operation Manual

ViaLite RF Splitter / Combiner

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Split2.8 RDM. 2 input DMX/RDM Splitter. User guide

User Guide. JBL Professional UniAmp Power Amplifier Module Model 1214

B60 Domestic Voltage Optimisation Unit. Installation Manual

Installation & Operation Guide

LASERMET LS-20 INSTRUCTION MANUAL

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

REGARD mA output module. Installation, operation and maintenance

Applications Electronic Design/Development Battery Charging Launch Control Rackmount ATE Systems. DLM 600 Near Linear 600W DC Power Supply

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable

3+1 U CPCI Serial System

DEEP SEA ELECTRONICS PLC DSE103 MK II Speed Switch Operators Manual

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Installation & Operation Guide

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Ethernet Adapter User Guide

epowerswitch-8 Power Management Master Slave User's Guide

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Digi-modems. Issue 3

High Power over Ethernet Midspans PD Port Model PD Port Model

903 PORTABLE TEMPERATURE TEST UNIT

AT-8900, AT-9900, AT-9900s Switches Removable Power Supply and Fan Installation Guide

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

Supplementary operating instructions for your air curtain system Controller TMC 500

MINI-PS AC/10-15DC/8

Transcription:

MAINS DISTRIBUTION UNIT MDU14-CO Dual Input Auto Changeover 14 Output Mains Distribution Unit. Handbook Television Systems Limited. Vanwall Road, Maidenhead, Berkshire, SL6 4UB Telephone +44 (0)1628 676200, FAX +44 (0)1628 676299

This Page is Blank MDU14-CO Manual 2 Issue 6

Contents 1.0 Installation & Safety Requirements. 2.0 Description 3.0 Introduction 4.0 Operation 5.0 Pin-outs 6.0 Specifications. MDU14-CO Manual 3 Issue 6

This Page is Blank MDU14-CO Manual 4 Issue 6

SAFETY 1.0 Installation. Installation of this equipment should be in accordance with BS7671. In particular, this includes regulation 460-01-02, which states that each source of supply should have a main switch provided, with a durable warning notice permanently fixed in such a position that any person seeking to operate any of these main switches will be warned of the need to operate all such switches to achieve isolation of the installation. Alternatively, a suitable interlock system may be provided. It is not recommended to use the unit with different phase inputs. The unit is provided with a front panel double pole switch, which will provide isolation from any supply for all the outputs of the MDU. Note that this switch does not isolate the incoming supplies from the MDU itself; this can only be done via the above main switches or by removing the input connectors. Note the MDU internally has 16A fuses in each incoming feed; and also 2A fuses for the internal power supplies. This equipment is intended for use with TN-S power distribution systems (IEC60364-3). Although all internal switching is double-pole, it is a requirement that each Neutral conductor is connected to earth; internal fusing is present in the Live circuit only. Unless otherwise stated TSL equipment may be installed at any angle or position within an operating temperature range of 5 ~ 30 C. All TSL equipment conforms to the EC Low Voltage Directive: EC Low Voltage Directive (73/23/EEC)(OJ L76 26.3.73)(LVD). Amendment: (93/68/EEC) (OJ L220 30.8.93). Earthing/Grounding In all cases, the frame of the equipment must be earthed on installation. Connection to an earthed strip running the length of the frame is ideal. The earth pin on the mains inlet connector is connected to the metal frame of the equipment, to 0 volts on the internal DC PSU and to signal ground, unless otherwise stated. All metal panels are bonded together. Rack mounted equipment must be earthed (grounded). Mounting Careful consideration of the equipment location and mounting in racks must be made. In particular, consideration must be given to the stability of free-standing racks by mounting heavy equipment low in the rack. The rear of the unit should be supported in the rack. Ventilation Due consideration for cooling requirements must be given when mounting the equipment. The equipment contains an internal temperature sensor. General If equipment is installed in a closed unit, consideration must be given to providing forced air cooling in order that the maximum recommended temperature is not exceeded. MDU14-CO Manual 5 Issue 6

WARRANTY, MAINTENANCE AND REPAIR All TSL equipment is guaranteed for one year from the date of delivery to the customer s premises. If the equipment is to be stored for a significant period, please contact TSL concerning a possible extended warranty period. Failure during warranty If any TSL product should fail or become faulty within the warranty period, first please check the PSU fuses. All maintenance work must be carried out by trained and competent personnel. If equipment has to be returned to TSL for repair or re-alignment, please observe the following overleaf: Technical support information E-Mail address: support@televisionsystems.ltd.uk Telephone Support Number for the UK and Europe: +44 (0) 1628 670000 Telephone Support Number for the USA only: 1 877 591 2108 MDU14-CO Manual 6 Issue 6

TSL Returns Procedure Please telephone +44 (0)1628 676200 (Fax: +44 (0)1682 676299) and ask for Sales who will provide a Returns Number. This will enable us to track the unit effectively and will provide some information prior to the unit arriving. For each item, this unique Returns Number must be included with the Fault Report sent with the unit. A contact name and telephone number are also required with the Fault Report sent with the unit. Fault report details required. Company: Name: Address: Contact Name: Telephone No: Returns Number: Symptoms of the fault (to include switch setting positions, input signals etc): Packing Please ensure that the unit is well packed as all mechanical damage is chargeable. TSL recommends that you insure your equipment for transit damage. The original packaging, when available, should always be used when returning equipment.. If returned equipment is received in a damaged condition, the damage should be reported both to TSL and the carrier immediately. This product conforms to the following rules: YEAR 2000 CONFORMITY REQUIREMENTS Rule 1 Rule 2 Rule 3 Rule 4 No value for the current date will cause any interruption in operation. Date based functionality will behave consistently for dates prior to, during and after the Year 2000. In all interfaces and data storage, the century in any date is specified either explicitly or by unambiguous algorithms or by inferencing rules. The Year 2000 is recognised as a leap year. MDU14-CO Manual 7 Issue 6

EC DECLARATION OF CONFORMITY Application of Council Directives Nos: EC Low Voltage Directive (73/23/EEC)(OJ L76 26.3.73)(LVD). Amendment: (93/68/EEC) (OJ L220 30.8.93). Conformity Standards Declared: EN 60950; BS-EN-62040-1-1:2003 EMC Directive: 89/336/EEC, Amended 92/31/EEC. Conformity Standards Declared: EN 50081-1, EN 50082-1 Manufacturer s Name: Manufacturer s Address: Television Systems Ltd Vanwall Road Maidenhead SL6 4UB England United Kingdom Type of Equipment: Model No: Part Number: Mains Distribution Unit MDU14-CO TSLP- MDU14-CO Date CE Mark Affixed: I, the undersigned, declare that the equipment specified above conforms to the quoted Directives and Standards. Place: Maidenhead, England Signature: Date: 24/02/2009 Print: A J Mackinder Position: PRODUCT MANAGER MDU14-CO Manual 8 Issue 6

I Power Change over Mains Distribution Unit MDU14-CO 0 2.0 Description Features: 19" 1RU. 14 Fused IEC outlets with green power good LEDs. Dual Input Seamless Auto Changeover LED Indication A/B Tri colour Master/Slave Indicators Power - Blue - Power applied to the unit. Green A, B, & Remote Master Control indication. This 1RU unit is designed to fit into a rack in any position. The inlets are via 2 Neutrik Powercon NAC3FCA connectors. 2 free cable mounted connectors are supplied with each unit. Output power to the 14 IEC outlets is via the switch fitted to the front panel. Each outlet is fused on the front panel with a 10A HCT fuse. A green power LED adjacent to each numbered fuse indicates the status of each fuse: Green good; Off Failed. 3.0 Introduction The MDU14-CO is a dual power input 14 output power distribution unit intended for racks where equipment needs a constant uninterrupted power supply. The 2 input power supplies go to a set of master changeover relays with control circuitry to detect power presence. In the event of a failure of the input in use the unit seamlessly will switch over to the backup supply within 50ms so no equipment is affected by the change. There is no load taken from the backup supply when not in use. From the relays the power is fed to a double pole mains switch/circuit breaker on the front panel which feeds the 14 outputs. Each rear IEC output is fed via a front panel fuse with Green LED indicator showing condition of the fuse. The unit has Master or slave control capability so that when the master power is restored the unit will switch back to the original source. This ensures that any backup power source isn t used unnecessarily. 4.0 Operation Wire the supply inputs to A and B from the appropriate sources. NB Ensure you comply with the safety instructions in section 1 of this manual. Wire the outputs as required. MDU14-CO Manual 9 Issue 6

4.1 Master Slave Input select. With the front panel power switch in the off position, power is still supplied to the control circuits and relays. The tri-colour LEDS labelled A & B next to the mains switch show 3 states: Green Power on input & available to the outputs Amber Power on input but in standby Red No power on input. Either Input A or B or No Master can be selected and this status is indicated by the LEDs either side of the Master select pushbutton. To change from the current status press and hold the enable button and toggle the Master button until the appropriate LED is lit under A or B label. For No Master neither LED will be lit. In this condition the unit will stay on the presently selected source until either this fails or someone changes the state, but it will not automatically return to a nominated input. The red Status LED indicates that there is a fault condition & the unit needs to be reset. It will not change in this state. Power is only switched to all 14 outputs when the switch on the front is turned on, and this is indicated by all the green output LEDs being on. In the event of a fault on any output which causes a front panel fuse to blow the LED associated with that output will be off. Whenever such a condition occurs the fault must be rectified prior to refitting the fuse. 5.0 Pin-outs Input Neutrik Powercon connector L Brown (Phase), N Blue (Neutral), E Green/Yellow (Earth or Ground). Serial Connector RS232 SERIAL RS 232 CONNECTOR D9 SOCKET 1 +5V 6 A status green led 2 TX 7 A status red led 3 RX 8 B status green led 4 Error status led 9 B status red led 5 0v 6.0 Specifications Inputs A & B Outputs 1-14 Maximum Load 110-240V AC 50/60Hz Max load 16A Power consumption Standby 2W; Main 8W 110-240V AC Max load 10A per outlet, fused on front panel. 16A MDU14-CO Manual 10 Issue 6