ATE QUICK START GUIDE. KEPCO An ISO 9001 Company. VOLTAGE/CURRENT STABILIZED POWER SUPPLY I INTRODUCTION

Similar documents
BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY.

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY I INTRODUCTION

BIPOLAR OPERATIONAL POWER SUPPLY

ATE-DMG QUICK START GUIDE. KEPCO An ISO 9001 Company. VOLTAGE/CURRENT STABILIZED POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY.

OPERATOR S MANUAL ATE 1/2 RACK POWER SUPPLY AUTOMATIC TEST EQUIPMENT MODEL

An ISO 9001 Company. KLP POWER SUPPLY

INSTRUCTION MANUAL RA 59 RACK ADAPTER. 1) This manual is valid for the following Model and associated serial numbers: MODEL SERIAL NO. REV. NO.

BOP 1KW-G POWER SUPPLY

OPERATOR S MANUAL ATE 1/2 RACK POWER SUPPLY AUTOMATIC TEST EQUIPMENT MODEL

INSTRUCTION MANUAL ATE FULL RACK POWER SUPPLY AUTOMATIC TEST EQUIPMENT

OPERATOR MANUAL MAT 720W, 2/3-RACK POWER SUPPLY HIGH VOLTAGE MODELS: MAT 36-20, MAT 55-14, MAT 75-10, MAT , MAT

BRC SERIES 20kW High Voltage Power Supply

Applications Electronic Design/Development Battery Charging Launch Control Rackmount ATE Systems. DLM 600 Near Linear 600W DC Power Supply

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply

INSTRUCTION MANUAL RA 60 SERIES RACK ADAPTER RA 60, RA 62, AND RA 63. 1) This manual is valid for the following Model and associated serial numbers:

Power Supply and Fan Module Installation

Laboratory Switch Mode Power Supply Series. Instruction Manual

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

OPERATOR S MANUAL BOP (M) (D) 100W, 200W, 400W BIPOLAR POWER SUPPLY

Service Instructions. Conductor 420

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

LDD M SERIES INSTRUCTION MANUAL LDD M SERIES

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

User's Guide. Model W 3-in-1 Switching DC Power Supply

Basic Characteristics Data

KEPCO SINGLE OUTPUT, 1U SIZE, 100 WATT HOT SWAP PLUG-IN POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, HSF-1UR 100W SERIES

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-4C RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF 300W, 600W, 1200W, 1500W SERIES POWER SUPPLIES

from

OPERATOR S MANUAL HSP SERIES 1000 AND 1500 WATT SWITCHING POWER SUPPLY VOLTAGE/CURRENT STABILIZED DC SOURCE

HPD Series Programmable DC Power Supply. Operation Manual

Innovative Circuit Technology Ltd.

Junos WebApp Secure 5.0 Hardware Guide

3300 Series DC Power Supplies

CUS150M1 Instruction Manual

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

PCM-7140 Pulsed Current Source Operation Manual

HERCULES-5000 INSTRUCTION MANUAL

LED Driver Compact dimming

OPERATING MANUAL FOR THE 30KV A.C. TEST SET P123. Bicotest High Voltage Products Ltd

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

MANUAL FOR THE UNIVERSAL MANUAL CONTROLLER UMC - 31

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

DFI 7000 DIGITAL FORCE INDICATOR USER S GUIDE 1.0 INTRODUCTION 2.0 DESCRIPTION. 2.1 Configuration. 2.2 Specifications

INTRODUCTION CT87E FEATURES AND CONTROLS

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Installing the Cisco MDS 9020 Fabric Switch

Power Supply Installation

EFE300 / EFE400 EFE300M / EFE400M

Installation Instructions H Series

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

LED Driver DC-String

XT Series Programmable DC Power Supply. Operation Manual

Basic Characteristics Data

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE

SIM-9106/9303 High Current Switching Mode Power Supply with C.C., C.V., Remote Control & Sensing User Manual

AC/DC Power Supply Series APPLICATION NOTE

Installing the Cisco AS5400XM Universal Gateway

PLD Series +5V Laser Diode Drivers

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Cantata m100 Amplifier

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II

Installation, Operation and Maintenance Manual

Model 500 Series Laser Diode Driver User's Manual

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE PTC-20 PELTIER TEMPERATURE CONTROL SYSTEM

SureTest Model ST 1D Instructions

EFE300 / EFE400 EFE300M / EFE400M

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

SERVICE MANUAL MAT 1/3 RACK (EXCEPT 6-32) POWER SUPPLY

DTC P0AA6 - High Voltage Isolation Fault

LVDT Test Device. Product Manual (Revision B) Original Instructions. Testing and Calibration of LVDT Feedback Devices on PG Governors

NI PXIe-1062Q Power Supply Shuttle

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

An ISO 9001 Company. HWS , HWS , HWS , HWS , HWS Zero Up Programmable Power Supply

PIM-Mini Pulsed Current Source Operation Manual

LED Driver DC-String

LED Driver Linear / area dimming. Driver LC 50W mA 54V 0-10V lp EXC UNV EXCITE series SELV

Artisan Scientific is You~ Source for: Quality New and Certified-Used/Pre:-awned ECJuiflment

Power Supply and Fan Module Installation

PRM MODEL TABLE. (1) Measured at 115V a-c source.

Power Supply (48Vdc, 2.5A)

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE HVA-100 HIGH VOLTAGE AMPLIFIER MODULE FOR EPMS SYSTEMS

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

OPERATING INSTRUCTION

manufactured by SF8150-ZIF14

99 Washington Street Melrose, MA Phone Toll Free Visit us at INSTRUCTION MANUAL

S300i. Two Channel Integrated Audio Amplifier

1-36V, 0-3A DC Power Supply

REGULATED DC POWER SUPPLIES

Basic Characteristics Data

Transcription:

QUICK START GUIDE KEPCO An ISO 9001 Company. ATE VOLTAGE/CURRENT STABILIZED POWER SUPPLY I INTRODUCTION 1.1. SCOPE OF MANUAL. This Quick Start Guide covers simple installation and local operation of the Kepco ATE Series of 50W, 100W, 250W, 500W and 1000W voltage and current stabilized ATE d-c power supplies, both M suffix (analog meter) and DM suffix (digital meter). Full specifications, features and instructions are found in the associated Operator Manuals that can be downloaded free from the Kepco web site at: www.kepcopower.com/support/opmanls.htm#ate 1.2. DESCRIPTION. The Kepco ATE with programmable overvoltage protector is a precision stabilized power supply which can deliver either stabilized output voltage or current. The prevailing operating mode is indicated by LED mode indicators at the front panel (Figure 1). Operating mode crossover is automatic and may be monitored remotely by means of a flag signal, available at the rear programming connector. The power supply features full range output control by means of 10-turn, high resolution front panel potentiometers for output voltage and output current. A pair of front panel meters constantly monitor the output voltage and output current. The ATE power supply features user-selectable slow or fast operating modes. Slow mode operation is recommended for applications demanding a voltage source with low ripple. Fast mode operation is best if the output voltage must change rapidly, either in response to an external programming signal, or if the ATE is used as a current stabilizer which must react quickly to changes in load resistance. The ATE power supply is delivered for slow mode operation. Refer to Operator Manual (see PAR. 1.1) for converting the ATE power supply to fast mode operation. An overvoltage protection circuit, continuously adjustable as well as remotely programmable, is a built-in feature. The trigger point of the overvoltage protector may be set (or checked) under actual operating conditions by the front panel-accessible setup controls. Units are shipped for 115V a-c operation (105V to 125V a-c), 50 to 65Hz. For operation at 104V a-c, 208V a-c or 230V a-c refer to the full Operator manual (PAR 1.1). 1.3. OPTIONS. Standard models (M suffix) include analog voltage and current meters. Models with a DM suffix include digital meters. Suffix L indicates models with front panel knobs that have been replaced by locking-type screwdriver-adjustable front panel controls. Suffix L may be added to either M or DM models. 1.4. EQUIPMENT SUPPLIED. ATE 1/4 Rack only: PC 13 connector (PC 13 is an unwired PC 12 that has been pre-wired for front panel control of ATE 1/4 Rack models which MUST be installed at rear panel to enable local operation). ATE 1/2, 3/4, Full Rack only: PC 14 connector (PC 14 is an unwired PC 12 that has been prewired for front panel control of ATE 1/2, 3/4 and Full Rack models which MUST be installed at rear panel to enable local operation). 115V a-c Line Cord 1.5. ACCESSORIES (NOT SUPPLIED) Unwired PC 12 programming connector(s) Rack adapter RA 24, RA 32 or RA 37 to mount rack unit(s) in 19-inch rack) Slides for Rack Adapter or Full Rack models 2012, KEPCO, INC 1 Data subject to change without notice 228-1757

1/4 Rack 50W, 100W 1/2 Rack 250W 3/4 Rack 500W Full Rack 1000W FIGURE 1. FRONT PANEL CONTROLS AND INDICATORS 2 228-1757 021012

II SAFETY. Exercise care in making all connections to and from the ATE terminals. WARNINGS 1. Remove a-c power from the ATE before making any connections. 2. Wires and/or cables, connected from the ATE terminals to external components or programming devices must be properly insulated and securely terminated on both sides to make accidental touch impossible. 3. The ATE chassis and cover must be safety-grounded to a reliable a-c source ground. A safety-ground may be established by using a grounded a-c power outlet or, if the latter is not available, by means of a separate wire, from the provided GROUND terminal (at the rear barrier strip) to a reliable a-c source ground point. III INSTALLATION 3.1. UNPACKING. The power supply has been thoroughly inspected and tested prior to packing and is ready for operation. After careful unpacking, inspect for shipping damage before attempting to operate. Perform the Preliminary Checkout (PAR. 3.2). If any indication of damage is found, file an immediate claim with the responsible transport service 3.2. PRELIMINARY CHECKOUT. A simple operating check after unpacking and before permanent installation, is advisable to ascertain whether the ATE has suffered damage in shipment. 1. Install Programming Connector (supplied) at rear panel. This is required for local control of the unit. 2. Refer to Safety instructions (see Section II) and connect unit to 115V a-c source; refer to Operator manual (see PAR 1.1) for different source voltage. 3. Set the ATE front panel controls (Figure 1) as follows: a. Turn CURRENT control fully clockwise. b. Turn VOLTAGE control fully counterclockwise. c. Set a-c power ON/OFF switch/circuit breaker to ON. d. Verify that Voltage MODE indicator is on. 4. Slowly turn VOLTAGE control clockwise and observe a gradual increase of output voltage. Verify that the VOLTMETER reads full scale when control is fully clockwise. 5. Check the overvoltage crowbar circuit as follows: a. Turn the VOLTAGE control to about one-half of its range. b. Depress the DISARM pushbutton and turn the (recessed) LEVEL control slowly counterclockwise until the CROWBAR indicator lights. c. Turn VOLTAGE control slightly counterclockwise and release DISARM button. Now when the VOLT- AGE control is increased to the overvoltage setpoint, the input circuit breaker trips off. d. To set overvoltage to a different value repeating steps a, b, and c, except at step a set the VOLTAGE control to the desired overvoltage setting. e. Turn A-C POWER switch/circuit breaker to OFF. 6. Place a short circuit across the ATE output terminals. Turn CURRENT control counterclockwise. Turn the ATE power to ON. THE CURRENT MODE indicator should now be on. Slowly turn CURRENT control clockwise and observe the gradual increase in output current. Verify that the AMMETER reads full scale when the control is fully clockwise. 7. Set A-C POWER circuit breaker/switch OFF. Remove the short circuit from the output terminals. This concludes the preliminary check-out of the ATE. 3.3. INSTALLING THE POWER SUPPLY. ATE models are shipped with four plastic feet installed for benchtop operation. The feet must be removed for rack mounting. Kepco s RA 24, RA 32 or RA 37 Rack Adapters can be used to install these models in a standard 19-inch rack (installation instructions supplied with rack adapter). 021012 228-1757 3

3.4. CONNECTIONS. Connections are made using the rear panel terminations (see Figure 3). 3.4.1. LOAD CONNECTION, GENERAL. Connect the load between OUT and +OUT output power terminals at the rear panel (see Figure 3. Sense connections are required, either local or remote, must be used; otherwise the unit will not operate. 1/4 Rack 50W, 100W See PAR. 3.4.2 for local sensing, see PAR. 3.4.3 for remote sensing. Refer to the full Operator Manual (see PAR. 1.1) if step changes in the load are expected if, for example, the load is rapidly changing in value, or if the power supply is programmed with step functions (square wave, pulse, etc.) and maximum dynamic performance is expected. If so, set the unit to fast mode by referring to the full Operator Manual (see PAR. 1.1). Note that ripple in fast mode will be higher than for the default slow mode. Terminals on the programming connector at the rear panel and on the barrier strip (TB201) permit maximum flexibility in power supply/load interface techniques. The programming connector supplied has been pre-wired with jumpers configured for front panel (local) control of output voltage, output current and VP crowbar level with the power supply operating in the slow mode. 1/2 Rack 250W The rear programming connector MUST be installed for power supply to operate. To configure the programming connector to allow remote programming of the power supply, fast mode, or to use a user-configured unwired PC 12 programming connector (or to modify the programming connector supplied), refer to the full Operator Manual (see PAR. 1.1). If the programming connector jumper configuration has been altered, make sure that all wires are properly soldered: loose connections at the programming connector will cause the power supply to malfunction. 3/4 Rack 500W, Full Rack 1000W 3.4.2. LOAD CONNECTION, LOCAL SENSING. Figure 2 illustrates load connection using local sensing. Refer to the full Operator Manual for load wire selection guidelines. The output power leads should be twisted or tied together to reduce EMI. FIGURE 2. LOCAL SENSING 4 228-1757 021012

1/4 Rack 50W, 100W 1/2 Rack 250W 3/4 Rack 500W Full Rack 1000W FIGURE 3. REAR PANEL TERMINATIONS 021012 228-1757 5

3.4.3. LOAD CONNECTION, REMOTE SENSING. To avoid excessive output effects at remote loads, remote error sensing must be used (Kelvin connection). A pair of wires (twisted to reduce EMI) connected from the sensing terminals directly to the load will compensate for load wire voltage drops up to 0.5 volt per wire (refer to Figure 3. 3-4). Observe polarities: the negative sensing wire must go to the negative load wire, and the positive sensing wire goes to the positive load wire. supply. If the internal signal ground is not desired, the connection to the chassis can be opened (see full Operator Manual). 1/4 Rack 50W, 100W For large capacitive loads with long wire runs, refer to the full Operator Manual for techniques used to reduce low frequency oscillations observed at the load. 3.4.4. INPUT A-C CONNECTIONS. Install the line cord (supplied) at the rear panel and connect to 115V a-c, 60Hz (105V to 125V a-c, 50 to 65Hz) mains. Refer to the full Operator Manual for operation at 104V a-c, 208V a-c or 230V a-c (see PAR. 1.1).A-C Safety Ground. The power supply is equipped with a 3-wire safety line cord and polarized plug. The third (green) wire in the line cord is connected to the chassis and the case of the unit. If a 2-terminal receptacle in combination with an adapter is used, it is imperative that the chassis of the power supply be returned to a-c ground with a separate lead. A grounding terminal is provided (at the rear barrier strip) for this purpose. 3.4.5. ISOLATION FROM GROUND. The d-c output is isolated from the a-c source and from any direct connection to chassis or ground. The maximum output voltage that can be supported between either output terminals and ground or chassis is 500V (d-c or peak), plus the maximum output voltage of the power supply. Either side of the output may be grounded. The common mode current (leakage from output to ground) Is less than 5 µa (rms) or 50 µa (p-p) at 115V a-c power input, 60 Hz. To avoid common mode current from affecting the ATE output, the system (including the programming device, if used, load, and ATE) must have a single connection to ground (earth ground). The d-c ground wire must be rated for the nominal output current of the ATE (e.g, for ATE 6-10M, use rating of 10A). Multiple signal grounds in the system may cause groundloop problems, since noise signals develop across the impedances between the multiple ground points. The exact physical location of the best single ground point must be carefully selected for minimum ripple/noise output. NOTE: A resistor/capacitor network is connected from the negative output terminal to the metal chassis of the power 1/2 Rack 500W 3/4 Rack 500W, Full Rack 1000W FIGURE 4. REMOTE SENSING 3.5. COOLING. The components in the ATE power supply rely on forced air cooling. SIDE PANEL OPEN- INGS AND THE TOP OF THE CASE MUST BE KEPT CLEAR FROM ALL OBSTRUCTIONS TO ENSURE AIR CIRCULATION. Periodic cleaning of the interior of the power supply is recommended. If the ATE is rackmounted or installed into confined spaces, care must be taken that the ambient temperature (the temperature immediately surrounding the power supply) does not rise above 65 C (~149 F). 6 228-1757 021012

IV OPERATION Turn the unit on using the front panel a-c power ON/OFF switch/circuit breaker (see Figure 1). CAUTION: DO NOT repeatedly toggle the ON/OFF switch as this may cause unit to fault. If actuator does not lock when released, wait a few seconds before trying again. The circuit breaker is trip-free; if overload exists, contacts cannot be held closed by actuator. NOTE: Rear programming connector (supplied) must be installed to enable local control of the unit. The ATE power supply is delivered for slow mode operation (see PAR. 1.2). Refer to full Operator Manual (see PAR. 1.1) for converting the ATE power supply to fast mode operation. 4.1. VOLTAGE MODE OPERATION. 1. With a-c power OFF, connect the load to the output terminals of the ATE Power Supply in accordance with safety (Section II), and grounding guidelines (PAR. 3.4). Always monitor the front panel meters while adjusting output voltage/current. 2. Turn VOLTAGE control completely counterclockwise and CURRENT control completely clockwise. 3. Set a-c power ON/OFF switch/circuit breaker to ON. Verify that voltage MODE indicator is on. 4. Observe front panel VOLTMETER and adjust VOLT- AGE control to the desired output voltage level. Set a-c power ON/OFF switch/circuit breaker to OFF. 5. Turn CURRENT control completely counterclockwise. 6. Apply a short circuit across the output terminals of the ATE Power Supply. 7. Set a-c power ON/OFF switch/circuit breaker to ON. Verify that current MODE indicator is on. 8. Observe front panel CURRENT meter and adjust CUR- RENT control to the required load current value, plus 2% of the rated current. In voltage mode operation, this setting will determine the voltage/current crossover point. 9. Set a-c power ON/OFF switch/circuit breaker to OFF. 10.Remove the short circuit from the output terminals. The power supply is now ready for operation. 4.2. CURRENT MODE OPERATION. 1. Before connecting the load to the power supply output terminals, set a-c power ON/OFF switch/circuit breaker to ON. Verify that VOLTAGE MODE indicator is on. 2. Observe the front panel VOLTMETER and adjust the VOLTAGE control to the required compliance (output voltage) level. 3. Set a-c power ON/OFF switch/circuit breaker to OFF. and connect a short circuit to the output terminals of the ATE. 4. Set a-c power ON/OFF switch/circuit breaker to ON. 5. Observe the front panel CURRENT meter and adjust CURRENT control to the desired value. Verify that CURRENT MODE indicator goes on to indicate that the power supply is in the current mode of operation. 6. Set a-c power ON/OFF switch/circuit breaker to OFF. 7. Remove the short circuit, then connect the load to the output terminals of the ATE Power Supply in accordance with safety (Section II), and grounding guidelines (PAR. 3.4). 8. Set a-c power ON/OFF switch/circuit breaker to ON. If the ATE does not enter the current mode (as indicated by the front panel CURRENT MODE indicator), the load resistance (R L ) is too high. Either 1) decrease R L, 2) increase VOLTAGE control setting, or 3) decrease CURRENT control setting. The ATE is now ready for operation. 4.3. OVERVOLTAGE CROWBAR, SETUP AND CHECK The overvoltage crowbar circuit protects the load from momentary or long-term overvoltages. The crowbar SCR conducts across the power supply output, and the a-c power ON/OFF switch/circuit breaker trips if such overvoltages occur. The setting of the front panel LEVEL control determines the threshold between the actual operating voltage of the power supply and the level at which the crowbar circuit will be activated. The LEVEL control can be set from 3 volts to 110% of the rated output voltage. The LEVEL control may be adjusted very close to the operating voltage (minimum threshold = 2% of rated output voltage or 0.5 volt, whichever is greater). The operation of the crowbar circuit can be checked without actually triggering the crowbar. 021012 228-1757 7

1. With the load disconnected from the power supply turn SET LEVEL control fully clockwise and set a-c power ON/OFF switch/circuit breaker to ON. 2. Observe front panel VOLTMETER and set VOLTAGE control to desired value at which crowbar must trigger (NOT to the actual operating voltage). 3. Depress the DISARM button (and keep it depressed) while turning the crowbar SET LEVEL control counterclockwise, until the SET LEVEL indicator goes on (simulated crowbar action). 4. Turn VOLTAGE control slightly counterclockwise to the actual operating voltage and release the DISARM button. NOTE: This adjustment establishes the threshold i.e., the difference voltage between the output voltage and the voltage at which the power supply will crowbar. For minimum false triggering use the largest threshold your load can tolerate. 5. To check the adjusted crowbar trigger level, depress DISARM push button and turn VOLTAGE control clockwise. Observe front panel VOLTMETER and note the voltage at which the crowbar SET LEVEL indicator goes on. Correct SET LEVEL adjustment as described above if necessary. Readjustment of the SET LEVEL control may be required after load and power supply have reached thermal equilibrium. NOTE: If an exact crowbar point at a remote load must be established, remote error sensing, must be used (see PAR 3.4). 6. Reduce power supply output voltage to its operating value. 4.4. ADDITIONAL FEATURES. The following features of the ATE power supply are covered in the full Operator manual (see PAR. 1.1). Remote Programming of the Voltage Control Channel Remote Programming of the Current Control Channel Remote Programming of Crowbar Level Automatic Tracking of Crowbar Level Use of EXT Current Comparison Amplifier Multiple System Control Series/Parallel Operation Use of Uncommitted Amplifiers and Isolated Flag Signals 8 228-1757 021012