NucleoCounter NC-200, NucleoView NC-200 Software and Code of Federal Regulation 21 Part 11; Electronic Records, Electronic Signatures (21 CFR Part 11)

Similar documents
Exhibitor Software and 21 CFR Part 11

ISSUE N 1 MAJOR MODIFICATIONS. Version Changes Related Release No. PREVIOUS VERSIONS HISTORY. Version Date History Related Release No.

Compliance Matrix for 21 CFR Part 11: Electronic Records

21 CFR PART 11 COMPLIANCE

REGULATION ASPECTS 21 CFR PART11. 57, av. Général de Croutte TOULOUSE (FRANCE) (0) Fax +33 (0)

TECHNICAL BULLETIN [ 1 / 13 ]

COMPLIANCE. associates VALIDATOR WHITE PAPER. Addressing 21 cfr Part 11

Compliance of Shimadzu Total Organic Carbon (TOC) Analyzer with FDA 21 CFR Part 11 Regulations on Electronic Records and Electronic Signatures

SDA COMPLIANCE SOFTWARE For Agilent ICP-MS MassHunter Software

ChromQuest 5.0. Tools to Aid in 21 CFR Part 11 Compliance. Introduction. General Overview. General Considerations

WHITE PAPER AGILOFT COMPLIANCE WITH CFR 21 PART 11

21 CFR Part 11 Module Design

Adobe Sign and 21 CFR Part 11

OpenLAB ELN Supporting 21 CFR Part 11 Compliance

Integration of Agilent UV-Visible ChemStation with OpenLAB ECM

21 CFR Part 11 FAQ (Frequently Asked Questions)

Integration of Agilent OpenLAB CDS EZChrom Edition with OpenLAB ECM Compliance with 21 CFR Part 11

The Impact of 21 CFR Part 11 on Product Development

EZChrom Elite Chromatography Data System. Regulatory Compliance with FDA Rule of Electronic Records and Electronic Signatures (21 CFR Part 11)

INFORMATION. Guidance on the use of the SM1000 and SM2000 Videographic Recorders for Electronic Record Keeping in FDA Approved Processes

Agilent ICP-MS ChemStation Complying with 21 CFR Part 11. Application Note. Overview

Assessment of Vaisala Veriteq viewlinc Continuous Monitoring System Compliance to 21 CFR Part 11 Requirements

White Paper Assessment of Veriteq viewlinc Environmental Monitoring System Compliance to 21 CFR Part 11Requirements

Metrohm White paper. FDA 21 CFR Part 11 Requirements for NIR Spectroscopy. Dr. N. Rühl

FDA 21 CFR Part 11 Compliance by Metrohm Raman

Using "TiNet 2.5 Compliant SR1" software to comply with 21 CFR Part 11

Sparta Systems Stratas Solution

Sparta Systems TrackWise Solution

Electronic Data Processing 21 CFR Part 11

Sparta Systems TrackWise Digital Solution

Guide for 21 CFR part 11 on NucleoView NC-200

System Assessment Report Relating to Electronic Records and Electronic Signatures; 21 CFR Part 11. System: tiamo (Software Version 2.

Technical Information

Introduction 2. History. Adapted to zenon version 6.20 (MH) January 13 th, 2006

21 CFR Part 11 LIMS Requirements Electronic signatures and records

Using "IC Net 2.2 " software to comply with 21 CFR Part 11

System Assessment Report Relating to Electronic Records and Electronic Signatures; 21 CFR Part 11. System: StabNet (Software Version 1.

System Assessment Report Relating to Electronic Records and Electronic Signatures; Final Rule, 21 CFR Part 11

Validation Checklist Appendix A WiZARD2 Secure and 21 CFR 11 Requirements

Using Chromeleon 7 Chromatography Data System to Comply with 21 CFR Part 11

Guidelines for applying FactoryTalk View SE in a 21 CFR Part 11 environment

Using the Titrando system to comply with 21 CFR Part 11

ComplianceQuest Support of Compliance to FDA 21 CFR Part 11Requirements WHITE PAPER. ComplianceQuest In-Depth Analysis and Review

Using Chromeleon Chromatography Management Software to Comply with 21 CFR Part 11

System Assessment Report Relating to Electronic Records and Electronic Signatures; Final Rule, 21 CFR Part 11. System: tiamo 2.3

Cell Therapy Data Management

Agilent Response to 21CFR Part11 requirements for the Agilent ChemStation Plus

Part 11 Compliance SOP

Electronic Records and Signatures with the Sievers M9 TOC Analyzer and DataPro2 Software

Using the Titrando system to comply with 21 CFR Part 11

21 CFR 11 Assistant Software. 21 CFR Part 11 Compliance Booklet

OM-MICROLITE-8 AND OM- MICROLITE-16 DATA LOGGERS AND OM-MICROLAB

Quick Guide NC-200. NucleoCounter. to the easiest cell count ever!

Spectroscopy Configuration Manager (SCM) Software. 21 CFR Part 11 Compliance Booklet

Guidance for a 21 CFR Part 11 implementation on Microsoft Office SharePoint Server 2007

Agilent Technologies Dissolution Workstation Software Electronic Records and Data Storage Background

Meeting regulatory compliance guidelines with Agilent ICP-MS MassHunter and OpenLAB Server

How to get your Movicon 11 project FDA 21 CFR Part 11 ready. Document: RAC-4105 Released: Updated: Rel. Movicon: 11.

Introduction. So what is 21 CFR Part 11? Who Should Comply with 21CFR Part 11?

EU Annex 11 Compliance Regulatory Conformity of eve

21 CFR Part 11 Fundamentals

Achieving 21 CFR Part11 Compliance using Exaquantum/Batch Authored by Stelex

Real World Examples for Part 11 Technical Controls

User Manual. Version 1 1/10/ of 26

Automation Change Management for Regulated Industries

System Assessment Report Relating to Electronic Records and Electronic Signatures; Final Rule, 21 CFR Part 11. System: tiamo 2.0

Achieving 21 CFR Part 11 Compliance using CENTUM VP

SomaticView Version 1.0

Learning Management System - Privacy Policy

21 CFR PART 11 FREQUENTLY ASKED QUESTIONS (FAQS)

Statement of 21 CFR Part 11 Validation Results

Minnesota State Colleges and Universities System Procedures Chapter 5 Administration

LCquan Configuring LCquan for Compliance with 21 CFR Part 11

21 CFR Part 11 Compliance DELMIA Apriso 2018 Implementation Guide

Achieving 21 CFR Part 11 Compliance using CENTUM VP

testo Comfort Software CFR 4 Instruction manual

Summary. Implementing CFR21 Part 11 with Movicon 11 Page 2

Premium HMI and FDA 21 Part 11 regulations TN0009. Version Description Date 1 First emission 10/04/2012

DFARS Requirements for Defense Contractors Must Be Satisfied by DECEMBER 31, 2017

Electronic Signature Policy

ABB Limited. Table of Content. Executive Summary

SECURITY & PRIVACY DOCUMENTATION

MySign Electronic Signature

CERTIFIED MAIL LABELS TERMS OF USE and PRIVACY POLICY Agreement

Data Security Option DSI. Manual: MU Revision 55. This Photo by Unknown Author is licensed under CC BY-NC-SA

LCquan Configuring LCquan for Compliance with 21 CFR Part 11

CALSTRS ONLINE AGREEMENT TERMS AND CONDITIONS

An Easy to Understand Guide 21 CFR Part 11

2. What is Personal Information and Non-Personally Identifiable Information?

Complying with FDA's 21 CFR Part 11 Regulation

Comply with Data Integrity Regulations with Chromeleon CDS Software

Therapy Provider Portal. User Guide

Emsi Privacy Shield Policy

AlphaTrust PRONTO - Transaction Processing Overview

Wescom Solutions, Inc. Practitioner Engagement Android Version CFR EPCS Certification Report

Prepared by. On behalf of The California HealthCare Foundation. Nov. 24, Sujansky & Associates, LLC 1

NIST Compliance Controls

GM Information Security Controls

5. The technology risk evaluation need only be updated when significant changes or upgrades to systems are implemented.

A Quick Guide to EPCS. What You Need to Know to Implement Electronic Prescriptions for Controlled Substances

Transcription:

NucleoCounter NC-200, NucleoView NC-200 Software and Code of Federal Regulation 21 Part 11; Electronic Records, Electronic Signatures (21 CFR Part 11) A ChemoMetec A/S White Paper March 2014 ChemoMetec A/S Gydevang 43 DK 3450 Allerod Denmark Phone +45 48131020 Fax +45 48131021 contact@chemometec.com www.chemometec.com

Table of Contents Introduction... 3 NucleoCounter NC-200... 3 How ChemoMetec A/S addresses 21 CFR Part 11... 3 Section A 21 CFR Part 11 Subpart B Electronic Records... 3 Part 11.10 Controls for closed systems.... 3 Part 11.10 (a)... 4 Part 11.10 (b)... 4 Part 11.10 (c)... 4 Part 11.10 (d)... 5 Part 11.10 (e)... 5 Part 11.10 (f)... 5 Part 11.10 (g)... 6 Part 11.10 (h)... 6 Part 11.10 (i)... 6 Part 11.10 (j)... 6 Part 11.10 (k)... 7 Part 11.30 Controls for open systems... 7 Part 11.50 Signature manifestations... 7 Part 11.50 (a)... 7 Part 11.50 (b)... 7 Part 11.70 Signature/record linking... 8 Section B 21 CFR Part 11 Subpart C Electronic Signatures... 8 Part 11.100 General requirements... 8 Part 11.100 (a)... 8 Part 11.100 (b)... 8 Part 11.100 (c)... 8 Part 11.200 Electronic signature components and controls... 9 Part 11.200 (a)... 9 Part 11.200 (b)... 9 Part 11.300 Controls for identification codes/passwords.... 9 Part 11.300 (a)... 9 Part 11.300 (b)... 10 Part 11.300 (c)... 10 Part 11.300 (d)... 10 Part 11.300 (e)... 10 Glossary...11 Product Notes...12 Disclaimer Notices...12 Trademarks...12 Ref. 994-0208 Rev 1.1 10. mar 2014 2 of 12

Introduction 20 th of August 1997, the US regulatory agency Food and Drug Administration (FDA) issued the 21 Code of Federal Regulation 21 Part 11; Electronic Records, Electronic Signatures (21 CFR Part 11) as effective. In short, the 21 CFR Part 11 defines the FDA acceptance criteria for use of electronic records and electronic signatures as equal to paper records with handwritten signatures. NucleoCounter NC-200 The NucleoCounter NC-200 is an integrated fluorescence microscope with dual fluorescence channels designed to detect signals from cells stained with acridine orange and/or DAPI (4',6-diamidino-2- phenylindole). The NucleoCounter NC-200 is a compact instrument for cell counting and viability measurement which fits perfectly in any mammalian cell laboratory performing e.g. research, quality control or monitoring of production. The NucleoCounter NC-200 is very simple to operate: simply load the Via1-Cassette and press run. It comes with a new developed software package. The user input of optional dilution of a sample is directly accounted for in the software. The protocols can be adapted by the user to accommodate cell lines that are out of the ordinary. How ChemoMetec A/S addresses 21 CFR Part 11 This document provides guidelines on how ChemoMetec addresses 21 CFR Part 11. The 21 CFR Part 11 regulations can only be applied when, the NucleoCounter NC-200 and the NucleoView NC-200 software are a closed system. Each relevant Part 11 section will be listed with number, text of the given part, resume of requirements and finally the approach taken by ChemoMetec to allow the user to meet the 21 CFR Part 11 regulation. Section A 21 CFR Part 11 Subpart B Electronic Records Part 11.10 Controls for closed systems. Persons who use closed systems to create, modify, maintain, or transmit electronic records shall employ procedures and controls designed to ensure the authenticity, integrity, and when appropriate, the confidentiality of electronic records, and to ensure that the signer cannot readily repudiate the signed record as not genuine. Such procedures and controls shall include the following: Ref. 994-0208 Rev 1.1 10. mar 2014 3 of 12

Part 11.10 (a) Validation of systems to ensure accuracy, reliability, consistent intended performance, and the ability to discern invalid or altered records. Ensure the system can detect invalid or altered records. Data files cannot be altered from within the NucleoView NC-200 software. Additional information can however be included in the data files, which afterwards are marked. The validity of data files are controlled via an internal checksum. For lab-level validation, specific support can be provided by external cooperation partners. Part 11.10 (b) The ability to generate accurate and complete copies of records in both human readable and electronic forms suitable for inspection, review, and copying by agency. Persons should contact the agency if there are any questions regarding the ability of the agency to perform such review and copying of the electronic records. Generate accurate records in human readable and electronic form For inspection, review and copy by agency all results can be printed directly from the NucleoView NC- 200 software to the default printer only. The default printer cannot be a file printer. All records can also be exported to other file formats including FCS and ACS and copied directly to clipboard to paste into other software. ChemoMetec A/S holds no responsibility for the further handling of exported or copied data. All acquired data files are saved in our own.cm file format consisting of the raw image data, the calculated results and the complete settings with which the data was acquired. Part 11.10 (c) Protection of records to enable their accurate and ready retrieval throughout the records retention period. Enable accurate and easily accessible retrieval of electronic records Data files cannot be deleted from within the NucleoView NC-200 software. Archived data files can be maintained in readily retrievable form using the combination of file servers and/or databases together with a running copy of the NucleoView NC-200 software. Ref. 994-0208 Rev 1.1 10. mar 2014 4 of 12

Part 11.10 (d) Limiting system access to authorized individuals. Differential access to use the NucleoCounter NC-200 system Access control to the NucleoCounter NC-200 system relies on Windows ACL to assign individuals to different user groups. Only individuals belonging to system administrators, NucleoViewAdmin, NucleoViewSuperVisor and NucleoViewUser user groups can access the NucleoView NC-200 software. Part 11.10 (e) Use of secure, computer-generated time-stamped audit trails to independently record the data and time of operator entries and actions that create, modify, or delete electronic records. Record changes shall not obscure previous recorded information. Such audit trail documentation shall be retained for a period at least as that required for the subject electronic records and shall be available for agency review and copying. Ensure audit trail for all actions made by the user, and that no records are deleted A time-stamped Event Log automatically and continuously records all actions made by the user. It is not possible from within the NucleoView NC-200 software obscure or delete data, only adding of comments to the gathered data is possible. The event log contains information on date, time, user name, full name, domain of computer, serial number of NucleoCounter NC-200 used along with type of action performed. For each data file the user name and full name is recorded along with the serial number of the NucleoCounter NC-200. Any additional information entered in a data file will be logged inside that date file with user name and time stamp, and thereby complies to the total retention period. Archived Event Log files are human readable using any standard text editor, and can be maintained in readily retrievable form using the combination of file servers and/or databases. Part 11.10 (f) Use of operational system checks to enforce permitted sequencing of steps and events, as appropriate. Control the right sequence of steps and events The NucleoCounter NC-200 system is a fully automated system, and validated to ensure that all gathering of data follows a predefined sequence defined in the protocol of the software. Ref. 994-0208 Rev 1.1 10. mar 2014 5 of 12

Part 11.10 (g) Use of authority checks to ensure that only authorized individuals can use the system, electronically sign a record, access the operation or computer system input or output device, alter a record, or perform the operation at hand. Control of the right of individual users to use the NucleoCounter NC-200 system Access control in NucleoView NC-200 software is based on Windows ACL and a predefined set of user groups. The IT-manager can limit the access to authorized users. Part 11.10 (h) Use of device (e.g., terminal) checks to determine, as appropriate, the validity of the source of data input or operational instruction. Control that the source of data input is appropriate The NucleoCounter NC-200 system relies upon licenses and settings files along with predefined scripts to ensure that all steps in data acquisition are appropriate for the chosen application. All instruments are controlled in regards to type and serial number whenever data is acquired to ensure validity of the source of data input. Part 11.10 (i) Determination that persons who develop, maintain, or use electronic record/electronic signature systems have the education, training, and experience to perform their assigned tasks. Proper training of all users and developers Training in use of the NC-200 system for data acquisition can be provided by ChemoMetec A/S. Other training in order to reach full 21 CFR Part 11 compliancy for the individual laboratories relies solely on the laboratory e.g. in cooperation with external cooperation partners. Part 11.10 (j) The establishment of, and adherence to, written policies that holds individuals accountable and responsible for actions initiated under their electronic signatures, in order to deter records and signature falsification. Provide policies to deter against falsification of records Windows does not allow creation of two user accounts with same user name. Local lab policies and procedures needs to ensure that there can be no reuse of user names. The user account information is recorded within the data file for the individual creating the data file and individual(s) modifying an existing data file. Local lab policies and procedures needs to be defined to hold individuals accountable for actions initiated under their electronic signature. Ref. 994-0208 Rev 1.1 10. mar 2014 6 of 12

Part 11.10 (k) Use of appropriate controls over systems documentation including: (1) Adequate controls over the distribution of, access to, and use of documentation for system operation and maintenance. (2) Revision and change control procedures to maintain an audit trail that documents time-sequenced development and modification of systems documentation. System Document Control ChemoMetec A/S follows change control and life cycle management procedures for document control. Part 11.30 Controls for open systems Persons who use open systems to create, modify, maintain, or transmit electronic records shall employ procedures and controls designed toensure the authenticity, integrity, and, as appropriate, the confidentiality of electronic records from the point of their creation to the point of their receipt. Such procedures and controls shall include those identified in 11.10, as appropriate, and additional measures such as document encryption and use of appropriate digital signature standards to ensure, as necessary under the circumstances, record authenticity, integrity, and confidentiality. Controls for Open Systems While the NucleoCounter NC-200 system can be operated as an open system per 21 CFR Part 11.3, Chemometec A/S encourages customers to configure the NucleoCounter NC-200 system a a closed system. Chemometec A/S s validation protocol only verifies that the NucleoCounter NC-200 system functions as a closed system and precludes the need to establish additional controls for open systems. Part 11.50 Signature manifestations Part 11.50 (a) Signed electronic records shall contain information associated with the signing that clearly indicates all of the following: (1) The printed name of the signer; (2) The date and time when the signature was executed; and (3) The meaning (such as review, approval, responsibility, or authorship) associated with the signature. Definition of electronic signatures in data files An individual s user name and full name along with date and time will be included as part of any electronic signature executed on data files along with the meaning of the actual signature. Part 11.50 (b) The items identified in paragraphs (a)(1), (a)(2), and (a)(3) of this section shall be subject to the same controls as for electronic records and shall be included as any human readable for of the electronic record (such as electronic display or printout). Ref. 994-0208 Rev 1.1 10. mar 2014 7 of 12

Requirements Definition of electronic signatures in relation to electronic display and printouts of data An individual s user name and full name along with date and time will be included as part of any electronic signature executed on electronic display of results and on printouts along with the meaning of the actual signature. Part 11.70 Signature/record linking Electronic signatures and handwritten signatures executed to electronic records shall be linked to their respective electronic records to ensure that the signatures cannot be excised, copied, or otherwise transferred to falsify an electronic record by ordinary means. Linking of electronic signatures to their respective electronic records The user account information is recorded within the data file for the individual creating the data file and individual(s) modifying an existing data file, herein included signing of the data file. Section B 21 CFR Part 11 Subpart C Electronic Signatures Part 11.100 General requirements Part 11.100 (a) Each electronic signature shall be unique to one individual and shall not be reused by, or assigned to, anyone else. Uniqueness of user names Windows does not allow creation of two user accounts with the same user name. Local lab policies and procedures shall be implemented to hinder reuse of user names. Part 11.100 (b) Before an organization establishes, assigns, certifies, or otherwise sanctions an individual s electronic signature, or any element of such electronic signature, the organization shall verify the identity of the individual. Verify identity of user Local lab policies and procedures shall be implemented to verify the identity of individuals who will render electronic signatures. Part 11.100 (c) Persons using electronic signatures shall, prior to or at the time such use, certify to the agency that the electronic signatures in their system, used on or after August 20, 1997, are intended to be the legal binding equivalent of traditional handwritten signatures. (1) The certification shall be submitted in paper form and signed with traditional handwritten signature, to Office of Regional Operations (HFC-100), 5600 Fishers Lane, Rockville, MD 20857. (2) Persons using electronic signatures shall, upon agency request, provide additional certification or testimony that a specific electronic signature is the legal binding equivalent of the signer s handwritten signature. Ref. 994-0208 Rev 1.1 10. mar 2014 8 of 12

Legal binding of electronic signature Local lab policies and procedures shall be implemented to ensure that the legal formalities are followed. Part 11.200 Electronic signature components and controls Part 11.200 (a) Electronic signatures that are not based upon biometrics shall: Part 11.200 (a) (1) Employ at least two distinct identification components such as an identification code and password. (i) When an individual executes a series of signings during a single, continuous period of controlled system access, the first signing shall be executed using all electronic signature components; subsequent signings shall be executed using at least on electronic signature component that is only executable by, and designed to be used only by, the individual. (ii) When an individual executes one or more signings not performed during a single, continuous period of controlled system access, each signing shall be executed using all of the electronic signature components. Part 11.200 (a) (2) Be used only by their genuine owners; and Part 11.200 (a) (3) Be administered and executed to ensure that attempted use of an individual s electronic signature by anyone other than its genuine owner requires collaboration of two or more individuals Components and design of electronic signatures Electronic signatures are composed of user name and password for the individuals user account. All signings will require input of user name and password along with an acceptance of the signing. The local IT department or external cooperation partner(s) must ensure that the windows user account is setup in a secure manner to hinder use of an individual s signature by anyone other than its genuine owner. Part 11.200 (b) Electronic signatures based upon biometrics shall be designed to ensure that they cannot be used by anyone other than their genuine owners. Biometric based signatures NucleoView NC-200 software is not validated to work with electronic signatures based upon biometrics. Part 11.300 Controls for identification codes/passwords. Persons who use electronic signatures based upon use of identification codes in combination with passwords shall employ controls to ensure their security and integrity. Such controls shall include: Part 11.300 (a) Maintaining the uniqueness of each combined identification code and password, such that no two individuals have the same combination of identification code and password. Ref. 994-0208 Rev 1.1 10. mar 2014 9 of 12

Uniqueness of user names and passwords combinations Windows does not allow creation of two user accounts with the same user name. Local lab policies and procedures shall be implemented to hinder reuse of user names. Part 11.300 (b) Ensuring that identification code and password issuances are periodically checked, recalled, or revised (e.g. to cover such events as password aging). Periodically verify issuance of signing credentials and properly administer users Local lab policies and procedures shall be implemented to maintenance the signing credentials of users. Part 11.300 (c) Following loss management procedures to electronically deauthorize lost, stolen, missing, or otherwise potentially compromised tokens, cards, and other devices that bear or generate identification code or password information, and to issue temporary or permanent replacement suitable, rigorous control. Management of potentially compromised identification codes and/or passwords Local lab policies and procedures shall be implemented to deauthorize identification codes and/or passwords that potentially have been compromised. Part 11.300 (d) Use transaction safeguards to prevent unauthorized use of passwords and/or identification codes, and to detect and report in an immediate and urgent manner any attempts at their unauthorized use to system security unit, and, as appropriate to organization management. Setup safeguards preventing and reporting unauthorized login attempts Local lab policies and procedures shall be implemented to ensure notification of system security and as appropriate organization management in case of unauthorized attempts to use electronic signatures. Part 11.300 (e) Initial and periodic testing of devices, such as tokens and cards, that bears or generates identification code or password information to ensure that they function properly and have not been altered in an unauthorized manner. Test of tokens and cards, which bear identification codes and passwords Local lab policies and procedures shall be implemented to ensure that tokens and cards are checked periodically. Ref. 994-0208 Rev 1.1 10. mar 2014 10 of 12

Glossary CFR Code of Federal Regulation CM file ChemoMetec specified file containing image and data information Full name Specified when creating a Windows user account. Usually the full name of the of the individual that owns the Windows User account. NucleoCounter NC-200 system The complete system consists of a NucleoCounter NC-200 connected to a computer with NucleoView NC-200 software installed. NucleoView NC-200 Software NucleoView NC-200 software is used to control the NucleoCounter NC-200 and to interpret and analyze the data acquired by use of the System. NucleoView user levels Access to certain features within the NucleoView NC-200 software are controlled by Windows ACL by assignment of users to one of three possible user levels; NucleoViewAdmin, NucleoViewSuperVisor and NucleoViewUser. Login name and User name Two words with same meaning used interchangeably. Primary name used to define a windows user account; must be entered together with user password when logging onto the computer. Also the name used in combination with the user password for electronic signatures. User account A record that consists of all information that defines a user to Windows 7 or Windows XP SP3, including the user name, password and full name of the individual along with information on the user group the individual belongs to. User password Secret code that in combination with the user name allows individuals with a user account to log onto the computer. Windows 7 and Windows XP SP3 Versions of Windows operating systems on which the NucleoView NC- 200 software runs and are supported by ChemoMetec A/S. Windows ACL Windows Access Control List to define users and user right. Ref. 994-0208 Rev 1.1 10. mar 2014 11 of 12

Product Notes The NucleoCounter NC-200 system is intended FOR RESEARCH USE ONLY. NOT FOR DIAGNOSTIC OR THERAPEUTIC USE. To reach full compliancy it relies upon the customer to implement Standard Operational Procedure (SOP), Technical Procedure (TP), training of individuals etc. Disclaimer Notices The material in this document and referred documents is for information only and is subject to change without notice. While reasonable efforts have been made in preparation of these documents to assure their accuracy, ChemoMetec A/S assumes no liability resulting from errors or omissions in these documents or from the use of the information contains herein. ChemoMetec A/S reserves the right to make changes in the product without reservation and without notification to its user. ChemoMetec A/S assumes no liability regarding the cited text from the 21 CFR Part 11 regulative and always directs the reader to FDA for correct and full information regarding all of the 21 CFR Part 11 regulations. All responsibilities for work done by external cooperation partners rely solely on these partners. Trademarks Copyright ChemoMetec A/S 2012. All rights reserved. No part of this publication and referred documents may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without prior written consent of ChemoMetec A/S, Gydevang 43, DK-3450 Allerød, Denmark. ChemoMetec and NucleoCounter are registered trademarks owned by ChemoMetec A/S. NucleoCounter NC-200, NucleoView and Via1-Cassette are trademarks of ChemoMetec A/S. Microsoft and Windows are registered trademarks of Microsoft Corporation in United States and other countries. Ref. 994-0208 Rev 1.1 10. mar 2014 12 of 12