Manual No: Revision: G. Mag Probe. Assembly Manual

Similar documents
Manual No: Revision: E. Mag Plus Probe. Assembly Guide

TLS-3XX Series Consoles

Manual No: Revision: D. Mag Retrofit Probe. Installation Guide

Vapor Monitor Interface Module

Manual No: Revision: A. TLS-4XX Consoles. Upgrade Installation Instructions

Manual No: Revision: F. Relay Output Modules. Installation Guide

IFSF Interface Module

INSTALLATION and QUICK HELP FOR TLS CONSOLE INTERFACE TO THE VEEDER-ROOT EMR4 DATALINK USING AN XTEND 900 MHZ WIRELESS MODEM Rev.

XTEND 900 MHZ WIRELESS MODEM For use with VEEDER-ROOT EMR4 DATALINK INSTALLATION INSTRUCTIONS Manual , Rev. A

TLS-450 To TLS-450PLUS Console

TLS-350 Series Consoles

TLS-450/TLS-450PLUS Consoles

Installing the A4504A PMC Bridge Adapter and A4509A Expansion Adapter. HP Part No. A Edition E1197 Printed in U.S.A.

TLS-4XX Setup and Operation

Pit Transition with 24" Fan Installation and Operators Instruction Manual

TLS4/8601 Series Consoles

INSTALLATION INSTRUCTIONS YAMAHA Speaker Adapter Accessory Model: PAC-Y2

Pressurized Line Leak Controller Module. For Veeder-Root TLS-350/350R Systems

Rack Power Distribution Unit AP7530, AP7540

Manual No: Revision: D. TLS-XB Expansion Box. Site Prep and Installation Manual

Keysight Technologies N9020B MXA Signal Analyzer

Installing the A4505A PCI Module Upgrade. HP Part No. A Edition E0297 Printed in U.S.A.

Installing the A4979A PMC Graphics Card. HP Part No. A Edition E1098 Printed in U.S.A.

Enable-IT 828W Weatherproof Professional Grade PoE Extender Unit Quickstart Guide

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

COOPER POWER SERIES. 600 A U-OP visible break connector system operation instructions. Deadbreak Apparatus Connectors MN650022EN

Enable-IT 821 Ethernet Extender Quickstart Guide Professional Grade Networking

SPORTSMAN PRICE LIST

TSP-LL2 Magnetostrictive Probe

LINEAR ACTUATOR CONTROL Use with NEW LEADER 7 manual

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Installation Guide for Flex Tap

SERVICE MANUAL MODEL SSW-321-X

CD-ROM Box Enclosure

CUBE Micro Station User Guide

Mobilcomm 1211 West Sharon Road, Cincinnati, OH 45240

* * Agilent Power Distribution Unit (PDU) Installation Guide

7" Touch Screen Display

5000 Series Bench Scale Platforms

LevelMaster Start-Up Guide

36'' & 48'' E-Z Shutter Fan Installation & Operator s Instruction Manual

AlphaServer DS20 Ultra SCSI Internal StorageWorks Shelf Configuration Guide

CR Getting Started Guide

Installation Note. Enhanced Memory Upgrade Kit (Option B72) for Agilent ESA-E Series and ESA-L Series Spectrum Analyzers

COOPER POWER SERIES. RS-485 digital communications accessory board installation and operation instructions. Voltage Regulators MN225074EN

SAVE THESE INSTRUCTIONS

Tower to Rack and Rack to Tower System Conversion Guide

CERTIFIED MAIL LABELS TERMS OF USE and PRIVACY POLICY Agreement

Installation Instructions

Manual No: Revision: B. Software Version 2.0. Inform.NET. Bulk Load File Format

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

FA-2448 SIX POSITION Filter Wheel

Print Mechanism Maintenance Kit

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Universal Tablet Mount Accessory for Flex TechBridge

Installation Note. Agilent Technologies ESA-E Series Spectrum Analyzers High Stability Frequency Reference (Option 1D5) Retrofit Kit

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

Zonit μats TM Users Guide μats1-lv Version 1.2

Instruction and Operation Manual. CRMS Contact Resistance Measurement System. Model Number Caution!

DSLR Camera Cage Shoulder Rig Kit (FC-03)

Ioline 300/350HF System

MULTI-MOUNT. Assembly Manual

MODBUS MANUAL For the AccUView UV Transmission Monitor

INSTALLATION INSTRUCTIONS. Decorative Display Frame and Optical Filter Kit. 32", 42", and 50"

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

ARC Magnetic Capping Headsets

EVO-TM2A EVO-TM2B Touch Screen Monitor

AURA SSD FOR MAC PRO. Installation Guide

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

VIDEO Camera Cage WITH MATTE BOX FC-65-N

Dosage Delivery System Operation Manual Document: Revision: A Distek, Inc. Operation Manual

i-series Videoconference Fixture

Installation Note. Agilent PSA Series Spectrum Analyzers Secure Memory Erase, Option 117

EMD-100 ELECTRIC DISPERSER

What s in the box. SUP paddle sensor. Paddle sensor mounting track. Charger. USB cable. In your Motionize SUP kit you will find:

TCD600 OPEN LOOP TENSION CONTROLLER INSTALLATION, OPERATION MANUAL ADDENDUM (NETWORK FEATURE)

Agilent Technologies 11667A DC to 18 GHz Power Splitter

Limit Switch Connectors

OilCop Component Wiring Installation Manual

Parts and Service Manual IMCO

MITSUBISHI ELECTRONICS AMERICA, INC.

1. If the impaired node is part of an HA pair, disable automatic giveback from the console of the healthy node:

Quick Start Guide Ioline StudioJet

Installation Guide. English. HP LaserJet 5, 5M and 5N Printer Duplex Printing Accessory (C3920A)

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

Zebra XiIII-Series Printer Safety and Quick Reference Guide

Z Series and S4M Ribbon/Head Open Sensor Assembly

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

DSLR Camera Cage Carbon Fiber Shoulder Rig Kit ( FC-02-CF )

AquaController Apex Probe Module 2

Model A4268A FWD SCSI Adapter Installation and Service Guide. Embedded Systems Operation Part No. A Edition E1097

Amphenol. 608 Series. Amphenol Limited. Design Features. Circular Environmental Connectors Approved to BS9522 F0020 (Pattern 608)

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

MK-MANTA III OWNER S MANUAL PARTS LIST & OPERATING INSTRUCTIONS

CR87B TEMPERATURE RECORDER

V E2B Snap-in I/O Module

It s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1

Proliphix EPA-60 Installation Guide

Basketball Shot Clock Set LX2180 Manual

Transcription:

Manual No: 576013-730 Revision: G Mag Probe Assembly Manual

Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Veeder-Root shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this publication. Veeder-Root reserves the right to change system options or features, or the information contained in this publication. This publication contains proprietary information which is protected by copyright. All rights reserved. No part of this publication may be photocopied, reproduced, or translated to another language without the prior written consent of Veeder-Root. DAMAGE CLAIMS / LOST EQUIPMENT Thoroughly examine all components and units as soon as they are received. If any cartons are damaged or missing, write a complete and detailed description of the damage or shortage on the face of the freight bill. The carrier's agent must verify the inspection and sign the description. Refuse only the damaged product, not the entire shipment. VEEDER-ROOT S PREFERRED CARRIER 1. Contact VR Customer Service at 800-873-3313 with the specific part numbers and quantities that were missing or received damaged. 2. Fax signed Bill of Lading (BOL) to VR Customer Service at 800-234-5350. 3. VR will file the claim with the carrier and replace the damaged/missing product at no charge to the customer. Customer Service will work with production facility to have the replacement product shipped as soon as possible. CUSTOMER S PREFERRED CARRIER 1. It is the customer s responsibility to file a claim with their carrier. 2. Customer may submit a replacement purchase order. Customer is responsible for all charges and freight associated with replacement order. Customer Service will work with production facility to have the replacement product shipped as soon as possible. 3. If lost equipment is delivered at a later date and is not needed, VR will allow a Return to Stock without a restocking fee. 4. VR will NOT be responsible for any compensation when a customer chooses their own carrier. RETURN SHIPPING For the parts return procedure, please follow the appropriate instructions in the "General Returned Goods Policy" and "Parts Return" pages in the "Policies and Literature" section of the Veeder-Root North American Environmental Products price list. Veeder-Root 2007. All rights reserved.

Table of Contents Introduction Contractor Certification Requirements...1 Related Manuals...1 Mag Probe Installation Kits Standard Mag Probe Installation Kit (849600-XXX)...2 Low Level Mag Probe Installation Kit...2 Assembling Mag Probe Components Attaching Mag Probe Canister Spacer Rings...4 Assembling Floats onto Mag Probe Shaft...4 Attaching Cable Connector to Probe Canister...5 Figures Figure 1. Standard Mag Probe Installation Kit... 3 Figure 2. Low Level Mag Probe Installation Kit... 3 Figure 3. Installing Mag Probe Canister Spacer Rings... 4 Figure 4. Mag Probe float installation... 5 iii

Introduction This manual describes how to identify and assemble the components of Standard Magnetostrictive Probes - Form Number 8473 and Low Level Magnetostrictive Probes - Form Number 8493 (available selected areas only). Instructions are included for assembling floats onto the probe shaft, attaching spacer rings to the probe canister, and attaching the probe s cable to the canister. For guidelines on site preparation, instructions on installing the Mag Probe into a tank, and instructions on connecting wiring from the Mag Probe to the console, refer to the Veeder-Root Site Preparation and Installation Manual. Some of the installation kit components, such as epoxy packs, will be needed when installing the Mag Probe into the tank. Do not discard any unused parts. Contractor Certification Requirements Veeder-Root requires the following minimum training certifications for contractors who will install and setup the equipment discussed in this manual: Level 1 Contractors holding valid Level 1 Certification are approved to perform wiring and conduit routing, equipment mounting, probe and sensor installation, tank and line preparation, and line leak detector installation. Level 2/3 Contractors holding valid Level 2 or 3 Certifications are approved to perform installation checkout, startup, programming and operations training, troubleshooting and servicing for all Veeder-Root Tank Monitoring Systems, including Line Leak Detection and associated accessories. Warranty Registrations may only be submitted by selected Distributors. Related Manuals 576013-879 TLS-3XX Series Consoles Site Prep and Installation Manual 1

Mag Probe Installation Kits Standard Mag Probe Installation Kit (849600-XXX) Standard (8473) Mag Probes are shipped with the installation kit listed in Table 1 and shown in Figure 1. Table 1.- Standard Probe Installation Kit Contents Quantity Description Part Numbers 1 Cable 330272-00X 1 2-inch* Product Float 330427-001 1 2-inch* Water Float 330426-00X 1 4-inch* Product Float 330425-001 1 4-inch* Water Float 330424-00X 1 Boot 329523-001 2 3-inch* OD Probe Canister Spacer Rings 329541-002 2 4-inch* OD Probe Canister Spacer Rings 329541-001 1 Cable Seal Kit (CSK) 330020-067 *Note: Depending on your order, this kit is shipped with either 2 or 4 floats and 3 or 4 spacer rings. Low Level Mag Probe Installation Kit Low Level (8493) Mag Probes are shipped with the installation kit listed in Table 2 and shown in Figure 2. Table 2.- Low Level Mag Probe Installation Kit Quantity Description Part Number 1 Cable, 5 feet long (standard size) 330272-001 1 2-inch* Product Float 331027-001 1 2-inch* Water Float 331030-00X 1 3-inch* Product Float 331012-001 1 3-inch* Water Float 331013-00X 1 Boot 331011-001 2 3-inch* OD Probe Canister Spacer Rings 329541-002 2 4-inch* OD Probe Canister Spacer Rings 329541-001 1 Cable Seal Kit (CSK) 330020-067 *Note: Depending on your order, this kit is shipped with either 2 or 4 floats and 3 or 4 spacer rings. 2

Mag Probe Installation Kits Low Level Mag Probe Installation Kit These two wires connect in the J-box to the two field wires from the Console Locking tabs (3) Product float Top view Probe cable connector (attaches to threaded connector on the top of probe canister) Side view 4-inch spacer ring Locking Water float (optional) 4-Inch Floats Note: your Mag Probe installation kit will contain 2-inch or 4-inch floats as per your order. Cable Boot Wire nuts Tie wrap Cord Grip Nut Bushing 1/2"-14 NPSL threads Body Note: watch orientation of bevels and tapers when assembling these cord grip components..4" Product float Epoxy sealant 1/2"-14 NPT threads Cord Grip Fitting.6" probes\pbinkit1.eps Cable Seal Kit Water float (optional) 2-Inch Floats Figure 1. Standard Mag Probe Installation Kit These two wires connect in the J-box to the two field wires from the console Tie wrap (CSK) Locking tabs (3) Product float Product float Wire nuts (CSK) Top view Probe cable connector (attaches to threaded connector on the top of probe canister) Note: your Mag Probe installation kit will contain 3-inch or 4-inch rings as per your order. Side view 3-inch spacer ring Water float (optional) Water float (optional) Cord Grip Nut Bushing 1/2"-14 NPSL threads Body 1/2"-14 NPT threads Cable Cord Grip Fitting (CSK) Note: watch orientation of bevels and tapers when assembling these cord grip components..4".6" Epoxy sealant (CSK) Locking tabs (3) Top view Side view 4-inch spacer ring 3-Inch Floats Boot Locking tabs (3) 2-Inch Floats Note: your Mag Probe installation kit will contain 2-inch or 3-inch floats as per your order. probes\pbinkit2.eps Figure 2. Low Level Mag Probe Installation Kit 3

Assembling Mag Probe Components Attaching Mag Probe Canister Spacer Rings 1. Open the Mag Probe shipping carton so that you have access to the probe. Also open the installation kit. 2. Following the instructions in Figure 3, install the proper spacer rings (3 or 4 ) onto the probe canister (although outwardly different, both the 3 and 4 rings are attached in the same way onto the canister). Top spacer ring (locking tabs up) Locking tab (3) Cut (3) After aligning spacer ring locking tabs over cuts, slide the ring down until its tabs rest on the bottom of the cuts. Twist spacer ring in either direction until locking tabs seat in notches. Notch (3) Up Canister Before sliding floats and boots over probe shaft, slide spacer ring over bottom of canister until locking tabs snap into groove. Bottom spacer ring (locking tabs down) Probe shaft Figure 3. Installing Mag Probe Canister Spacer Rings Assembling Floats onto Mag Probe Shaft The Product floats, Water Floats (if ordered), and Boots from Mag Probe Installation Kits are assembled on 8473/ 8493 probe shafts in the exact sequence and orientation shown in Figure 4. Note: Failure to snap the boot locking tabs into the locking indents on the probe shaft could cause the boot and float(s) to fall into the tank. Water floats must installed, if ordered, for the Mag Probe to operate correctly. Handle the Mag Probe carefully. Striking or dropping the probe will result in loss of calibration and could cause permanent damage. 4

Assembling Mag Probe Components Attaching Cable Connector to Probe Canister 8473 MAG PROBE FLOAT OPTIONS Up 4-Inch Floats - OR - Product float - shaft first. 2-Inch Floats Product float - shaft first. Boot tab locking indents Water float - (Optional) shaft second. Water float - (Optional) shaft second. Bottom of probe shaft Boot - Boot - 8493 MAG PROBE FLOAT OPTIONS 3-Inch Floats - OR - 2-Inch Floats - OR - LPG 2-Inch Float Product float - shaft first. Product float - shaft first. Magnet down Up Boot tab locking indents Bottom of probe shaft Water float - (Optional) shaft second. Boot - Water float - (Optional) shaft second. Boot - Boot - probes\comboflt.eps Figure 4. Mag Probe float installation Attaching Cable Connector to Probe Canister Attach the connector end of the Mag Probe cable to the threaded connector on top of the probe canister and tighten down the integral nut. This completes the Mag Probe assembly. Save the remaining kit components. They will be needed to install the Mag Probe into the tank (reference the console Site Prep and Installation manual). 5

For technical support, sales or other assistance, please visit: www.veeder.com