CP150B Vandal & Weather Resistant Keypad Security Systems

Similar documents
Digital Keypad Introduction

Bosch solution 6000 cheat sheets

Single Door Standalone Access Control User Manual

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Installation Instructions

CM-110SK Standalone Keypad Installation Instructions

CA111x-series Arming Station

DOLXFD1000B. Waterproof Access Control/Reader

User Manual. PCKeypad Wireless Keypad

Waterproof. Keypad/Reader/Controller

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

REMOTE KEYPAD with NFC Tag (KPT-32N, KPT-32N-F1)

W3-M. Metal waterproof standalone access control/reader. User Manual

Access control panel U-Prox IC E (Elevator control)

W3-H Waterproof Keypad/Reader/Controller

Installation Manual. Contents

Installation and User Manual

BC Digital Keypad. User Manual

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

Two Door Controller GEN-045

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

Solution 16 plus. User Guide Security System

Installation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1.

2000 Series e/em Style Keypad Installation and Programming Manual

D1265. Installation Guide. Touchscreen Keypad

791/793 Easy Entry Keypads

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

INSTALLATION SHEET 791 and 793 Easy Entry Keypads

MS-5000: MiniStar Reader

MS-7000: SuperStar Reader

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

EL-ST100 KEYPAD CONTROLLER

232iLM Keypad Installation and Programming Instructions

REX F-0-9 Standalone or Access Controller

232iLM Keypad Installation & Programming Instructions

2 IDS LCD Keypad User Manual C Issued March 2009

D1260/D1260B. Owner's Manual. Keypad

7760 LCD Glass Keypad

Fingerprint Access Control F1. User Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

UNIVERSAL EXPANDER FOR CARD / CHIP READERS INT-R. 1. Features. 2. Installation and start-up

MS-5000 MiniStar Reader. Quick Start Guide MS The MS-5000 MiniStar Reader. 1.0 Specifications

Fingerprint Door Lock OPERATOR S MANUAL

KP2000E/EM Series Style Keypad

MS-3000 MicroStar Reader

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

Fingerprint Door Lock User MANUAL

TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following:

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

Contents. 4. Disarming the Control Panel How to Disarm with a User Code How to Disarm using a Key-Switch or Remote...

DAS 250L CONTROL COMMUNICATOR INSTALLATION MANUAL

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

3.3: Setting momentary / latching switches Page Warning Regarding Operation Page 8

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

180 Series Keypad. Handbook. Revision 2.1

Wireless keypad PRF-LCD-WRL

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44

4XLFN6WDUW*XLGH. LYNXR is not intended for UL985 Household Fire applications.

F7_F707_F708 Installation Instruction V1.0 F7_F707_F708. Access Control Terminal. Installation Instructions

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO D ISSUED NOVEMBER 2002 VERSION 2.

-DTZ001- Stand-Alone Proximity Access Control. User Manual

ACTsmart2 Product Range Operating and Installation Instructions

Wireless Key fob, Key pad & Receiver Range

TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual

Stand-alone Proximity Access Control

TOUCHLOCK compact. Ins-182 Date code:

GSM Communicator GJD710 PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE YOU START THE INSTALLATION

ROSSLARE AC-115. Hardware Installation and User s Guide DOOR MODE 10/01

SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader

ADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

IDS X-Series User Manual E Issued June 2013

Stand-Alone Data Chip System

AK-21. Digital Keyless Entry System. Installation and Programming Instructions

Wiring Instructions v3

FEATURES AND PROGRAMMING GUIDE SELF-CONTAINED ACCESS CONTROL SYSTEMS:

GV-AS Controller. Installation Guide

Section 1 General Description. Section 3 How to Program Keypad. Section 2 Installation. CM-120TX Wireless Digital Keypads Installation Instructions

Emergency Dialer DIAL-ALERT MODEL: AD

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

Emergency Dialer DIAL-ALERT MODEL: AD-433S.

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

Quick Start Installation Guide

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

Wiring Instructions v4

Solution 144 Security Systems

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

Installation Instructions (KF-2000)

Transcription:

Vandal & Weather Resistant Keypad Security Systems EN Security System

CP150B - Vandal & Weather Resistant Keypad The CP150B keypad provides alarm and or access control functionality when used on selected Solution security control panels. Constructed from satin chrome plated zinc die cast, the CP150B keypad provides a high level of vandal resistance and is also weather resistant to IP67 making it ideal for external installations. The CP150B includes red and green indicators which are used to show area or door lock status and the 12 buttons with blue backlighting make it easy to operate in all lighting conditions. The keypad connects to the control panel via the RS485 encrypted LAN CP150B Keypad Compatibility Panels Supported Version Keypads Supported Solution 16i 2.19 Up to 8 Solution 16X 2.00 Up to 8 Solution 144 2.00 Up to 16 Solution E 2.00 Up to 16 Table 1: CP150B Compatibility and occupies a standard keypad position in the panel configuration. Various keypad options can be configured via the Devices - Keypad & Readers menu in panel programming. User access events are stored in the panel log and can also be reported if required. Figure 1: CP150B Keypad Keypad Addressing Each keypad fitted to the system must be assigned a unique address on the LAN. The CP150B includes a rotary address switch for quick selection. The following table shows the address setting for each keypad as well as the number of keypad devices each panels can support. Keypad Address Setting Address No Keypad No 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 Solution 16i Panel Solution 16X Panel Solution 144 Panel Solution E Panel Table 2: Keypad Address Table Figure 2: Keypad Address Switch Only 1 Keypad can be assigned to each address. All Keypads are supplied from the factory set to address 1. You must power cycle the panel or perform a LAN scan whenever you change the keypad address. Box Contents The CP150B box contains the following parts. Keypad Backing Plate Keypad Main Body Keypad Front Face Plate Plug On Connection Cable Cable Grommet Instruction Sheet Mounting Template 2 x (M3 x 6mm) Hex Screws 1 x 2mm Hex Key 6 x (M3 x 6mm) Phillips Head Screws 2 Bosch Security Systems 09/11 CP150BIRG FTR1.1

Installation The keypad should be installed onto a solid surface using suitable mounting fixtures. Wiring should only be performed while the control panel is powered off. Step 1) Using the 1:1 scale mounting template supplied, mark out the location of the 4 mounting holes and the cable exit hole before drilling out all points as necessary. Step 2) If the keypad is to occupy an address on the LAN other than address 1, you will need set the required address before assembling and mounting the keypad. Note each keypad on the system must have a unique address. See Table 2: for more information. CP150B Mounting Holes x 4 Assembly Screws x 6 Step 3) Once the keypad address has been set, slide the supplied cable grommet onto the connection cable and terminate the required wires. Unused wires should be insulated to prevent short circuits. Figure 4: Backing Plate Rear View Step 4) Pass the connection cable through the keypad backing plate and fit the grommet in place by pressing the first flange into the hole and leaving the second flange on the outside of the keypad. Make sure that it sits neatly in all places to ensure a correct seal. Step 5) Attach the connection cable to the keypad by plugging in the connector. Note the connector is polarised and will only plug in when correctly aligned. Do not use excessive force. Rubber Grommet Installation Step 6) Carefully assemble the keypad backing plate to the main body using the six Phillips head screws. Step 7) Mount the keypad to the wall and then fit the keypad face plate using the M3 x 6mm hex screw. Take care not to puncture or deform the cable grommet during installation. CP150B Mounting Template Scale 1:1 Figure 5: Side View Showing Grommet Installation 29.0mm 29.0mm 4 x 4.50mm (11/64 ) maximum holes 110.0mm 56.0mm 25.0mm (1 ) minimum hole size 54.0mm 58.0mm Figure 3: Mounting Template (Not to Scale) Figure 6: Installing the Face Plate Bosch Security Systems 09/11 CP150BIRG FTR1.1 3

Keypad Operation The CP150B keypad can be configured to provide system area control, door access control or both depending on the installation requirements. As there is no LCD display on the keypad, feedback is provided via the red and green indicators and the keypad sounder. The CP150B also includes an egress input and lock output which can be used to control door access if required. Using the on board lock output is not recommended when the CP150B is being used on an external wall of the building. In this case it is recommended that you run the lock control wires directly to an output located on the main panel or output expander module located inside the building. Keypad Button Functions The CP150B keypad consists of 12 individual buttons which are used to enter codes and control the system. Some buttons have a secondary functions that are activated by holding the button down for two seconds. The [#] and [*] buttons perform the same functions as the ON and OFF buttons on the standard display keypad. Button [0] to [9] [#] [ * ] # Button = ON Button * Button = OFF Button Keypad Button Functions Description The numeric buttons allow you to enter PIN numbers and other functions when required. To arm the system enter the user PIN followed by the [#] key. The [#] key performs the same function as the ON button on display enabled keypads. To disarm the system enter the user PIN followed by the [*] key. The [*] key performs the same function as the OFF button on display enabled keypads. Table 3: Button Functions Hold Down Functions The CP150B keypad supports the following hold down functions. These functions will only work if the keypad has been assigned to an area. When keypads are installed outside the premises and are being used for area control, it is recommended that you disable the emergency key functions to prevent nuisance alarms. See the Devices-Keypads & Readers-Emergency Keys menu option in panel programming to disable these features. Function Panic Fire Medical All ON All OFF Hold Down Functions Meaning Press and hold both the [1] and [3] keys down for 2 seconds to initiate a panic alarm. Press and hold both the [4] and [6] keys down for 2 seconds to initiate a fire alarm. Press and hold both the [7] and [9] keys down for 2 seconds to initiate a medical alarm. Enter a valid PIN and then press and hold down the [#] key, the system will turn On or Arm all areas that the user belongs to at the same time. Enter a valid PIN and then press and hold down the [*] key, the system will turn Off or Disarm all areas that the user belongs to at the same time. Table 4: Hold Down Functions The hold down 4 - Chime Mode and hold down 6 - Answer Incoming Call features can not currently be operated from the CP150B keypad. Keypad LED Indicators The CP150B keypad includes RED and GREEN indicator LEDs which provide visual feedback during system operation. The indicators will show alarm area status or door status depending how the keypad has been configured. The keypad cannot display alarm and door status at the same time. When being used to control the alarm as well as door access the area status display will always take precedence. 4 Bosch Security Systems 09/11 CP150BIRG FTR1.1

LED Operation For Area Control Led Condition Meaning Red On On Both On Red On and Alternate Both Off Area All On Area Area is OFF Area not ready to turn on - zone(s) unsealed Area armed in Part mode and all zones sealed. Area armed in Part mode with zones unsealed. Keypad initialising during power up or LAN scan. Home Area and Access Group not programmed or keypad not powered. Table 5: Keypad LED s - Area Control To have the keypad control an area on the alarm system you need to assign the keypad to a home area. See the Devices-Keypads-Home Area menu option in panel programming. If alarm system control is not required then you should set the home area option to No Area. To have the keypad control a door on the system you will need to assign the keypad to an access group. See the Devices-Keypads & Readers-Access Group menu option in panel programming. LED Function For Door Control Led Condition Meaning Red On Door Locked Red Fast Flash Door Unlocked Red Red Continuous Fast Flash 2 Flashes Alternate Both Off Door manually unlocked or overridden. Door automatically unlocked by schedule or time zone Keypad initialising during power up or LAN scan. Home Area and Access Group not programmed or keypad not powered. Table 6: Keypad LED s - Access Group Door Control Once assigned to an access group, the on-board Lock output and Egress input will automatically be assigned to the same access group as the keypad. If both alarm area and door control is required then you will need to assign a home area and an access group to the keypad. In this case the LED indicators will display for the area status only. The CP150B LED indicators will only display the status of the programmed home area. You cannot move between areas from this keypad. If you require multiple area status visibility you should use a display keypad like the CP700B. Keypad Alert Tones The CP150B keypad emits several distinct tones to alert you to particular system events. The keypad volume level cannot be adjusted on the CP150B however it can be turned off via panel programming by setting the keypad volume to the lowest level. See Devices-Commands- Volume menu in panel programming. Setting the keypad volume to off will also stop the key press beep during normal operation. Event Fire Burglary Trouble Key Press Exit Delay Keypad Alert Tones Alert Tone Emitted If the system registers a fire alarm, the reader will sound 3 short beeps followed by a 1.5 second pause. This will repeat until reset by the user or until the siren run time expires. If the system registers a burglary alarm, the keypad will sound a continuous siren tone until reset by a user or until the siren run time expires. If a system trouble condition occurs, the keypad will sound 4 x fast short beeps followed by a 5 second pause and will repeat this tone until the user acknowledges the trouble condition from a display keypad The keypad will sound one short beep every time a button is pressed. The exit delay warning will sound 1 short beep every second when the area the keypad has been assigned to is armed. During the last 10 seconds of exit time the warning tone will speed up indicating that the time has nearly expired. Bosch Security Systems 09/11 CP150BIRG FTR1.1 5

Entry Delay Error Chime Alert The hi/lo entry delay warning tone will sound once every second when an entry delay zone in the area the keypad has been assigned to is triggered. If the system is not disarmed before the entry time expires then an alarm will occur. If you press an invalid button during any data entry sequence, the keypad will sound a 2 second warning tone indicating that the command was not accepted. If chime mode is active then the keypad will sound fast short beeps to alert the user when a zone programmed for chime is opened. Chime mode is only applicable when the area is disarmed. Table 7: Keypad Tones When keypads are installed outside the premises, you may prefer that the alert tones are disabled. See the Devices-Keypads & Readers-Indicator Options menu in panel programming to disable these features. Egress and Lock Control The CP150B includes an egress input and a lock output which can be used to simplify the wiring when the keypad is being used for door or access control. The lock output consists of a protected open collector transistor that can be used to operate a relay to control the door lock. The output will go from open to low for fixed 5 seconds whenever the associated access group or door assignment is triggered. The on board lock output will operate for a fixed time period of 5 seconds when triggered. If a different time is required then you should use another output on the system to operate the door lock. The lock output, and LAN+ power supply are not designed to operate and power the door lock directly. You should always fit a relay and protection diode to the lock output in combination with a separate power supply. The optional CM444B Relay Module has been designed to suit this task. If you require the door to operate when the mains power has failed then you will also need to fit a battery backup to the external power supply. See the wiring diagram in Figure 7: for more details. The Egress input on the CP150B keypad allows you to simplify the wiring required to implement an egress button on the inside of the door. The egress input triggers the lock output on the keypad by operating or firing the associated Access Group or Door Assignment. The egress input should be connected via a momentary or push button switch to keypad ground. When the button is pressed the lock output on the keypad will trigger for a fixed 5 second period. For greater security, if the egress input is not being used it should be disabled via panel programming. See Devices-Keypads & Readers-General Options in panel programming. Any zone on the system can be configured to trigger an access group and can therefore also be used to operate the lock output on the CP150B. Configuration Examples control function only. 1) Install the keypad as per instructions. 2) Set the home area for the keypad. 3) Set keypad options as required remembering to disable keypad emergency alarms and or single button arming if the unit is being installed externally. 4) Assign users to the area. Access control function only. 1) Install the keypad as per instructions. 2) Set the access group for the keypad. 3) Set keypad options as required. 4) Set output to access group to operate door. 5) Set output event assignment. 6) Assign users to the access group. Both and Access control functions. 1) Install the keypad as per instructions. 2) Set the home area for the keypad. 3) Set the access group for the keypad. 4) Set keypad options as required remembering to disable keypad emergency alarms and or single button arming if the unit is being installed externally. 5) Set output to access group to operate door. 6) Set output event assignment. 7) Assign users to the area. 8) Assign users to the access group. Examples show how to configure the CP150B to control a door on a Solution 16i panel. Consult the installation manual for programming information if you are using a different panel. When doing both alarm and access control, the LED indicators on the keypad will only display and feedback alarm /area status information. 6 Bosch Security Systems 09/11 CP150BIRG FTR1.1

Connection Diagram CP150B The optional CM444B relay module provides an easy way to interface the keypad s lock output to the door lock. Because of its small physical size (12.5 x 46 x 12mm) it can be easily located in the wall cavity if required. Address Select Switch. Keypads must be set to a unique address as per Table 2: Keypad Address Table on page 2 All CP150B keypads are supplied from the factory set to Address 1. CM720B or CM723B Power Supply (Battery backed up) + - ONLY USE THE SUPPLIED CONNECTION CABLE WHEN INSTALLING THE KEYPAD + DOOR LOCK + TO DOOR LOCK N/O COM N/C CM444B RELAY CARD CM444 Relay Card DF70 +12V + - PROTECTION DIODE Wiring Legend RED = LAN + BLACK = LAN - WHITE = LAN A BLUE = LAN B YELLOW = LOCK GREEN = EGRESS CONTROL PANEL MODULE LAN - A B + BL WH BK RD EGRESS INPUT N/O RD YL Lock Output GN Egress Input To Control Panel You must power cycle the panel or perform a LAN scan after connecting the CP150B for the system to initialise the keypad. The egress input is low (0V) to trigger. Disable via panel programming if not being used. Keypad connection point. Only use the supplied cable to connect to this keypad. Make sure that the keypad buzzer opening is not blocked during installation or the volume will be greatly reduced. Figure 7: CP150B Connection Diagram CP150B Specifications Part Number: Operating Voltage: Module Connection: (RS485 LAN) Lock Output: Egress Input: CP150B - Vandal and Weather Resistant Keypad (IP67). 10.0V D.C. - 14.5V D.C. @ 100mA Max. Max total LAN length using multi strand security cable = 500m, Max total LAN length using 2 pair twisted shielded data cable (Belden 8723) = 1200m. See full control panel manual for complete wiring instructions. Protected open collector transistor output 500mA. Low to trigger. Can be disabled via software control. Dimensions: 92mm(W), 20mm(D), 132mm(H). CM444B = 46mm(W), 12.5mm(D), 12mm H) Environment: Fixing Method: Warranty: -30 to 55 C RH 5 to 85% at 30 C non-condensing. The CP150B should be mounted on a sturdy vertical wall using fixtures appropriate for the wall construction type. 3 years from date of manufacture (return to base). N12138 N12138 RoHS Bosch Security Systems 09/11 CP150BIRG FTR1.1 In the interest of ongoing product development this document is subject to change without notice. 7

Bosch Security Systems 25 Huntingwood Drive Huntingwood, NSW 2148 Australia Phone: +612 9672 1777 Facsimile: +612 9672 1717 2011 Bosch Security Systems BLCP150BIRG Issue FTR1.1