Troubleshooting Transient Faults

Similar documents
Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects?

Overview of Cisco Unified Computing System

Equipment Policies. Chassis/FEX Discovery Policy

Cisco Actualtests Questions & Answers

Actual4Test. Actual4test - actual test exam dumps-pass for IT exams

Cisco Exam Implementing Cisco Data Center Unified Computing Version: 9.0 [ Total Questions: 173 ]

UCSM Fault Management

Managing Blade Servers

Q&As. Troubleshooting Cisco Data Center Unified Computing. Pass Cisco Exam with 100% Guarantee

Cisco Exam Questions & Answers

CISCO EXAM QUESTIONS & ANSWERS

Cisco. Exam Questions DCUCI Implementing Cisco Data Center Unified Computing (DCUCI)

Upgrading Firmware through Auto Install

CISCO EXAM QUESTIONS & ANSWERS

Overview. Overview. Cisco UCS 6324 Fabric Interconnect with Cisco UCS B-Series Servers and C-Series Servers, which is. Overview 1

Cisco UCS Director Tech Module Cisco UCS Manager (UCSM)

You can monitor or use SPAN on port channels only for ingress traffic.

Cisco Questions & Answers

Hardware Monitoring. Monitoring a Fabric Interconnect

Implementing Cisco Data Center Unified Computing (DCUCI)

Managing Blade Servers

Power Management in Cisco UCS

Implementing Cisco Data Center Unified Computing (DCUCI)

LAN Ports and Port Channels

Questions & Answers


Configuring Cisco UCS Server Pools and Policies

Direct Attached Storage

Configuring Cisco UCS Server Pools and Policies

UCS Firmware Management Architecture

Real4Test. Real IT Certification Exam Study materials/braindumps

Course Description. Boot Camp Date and Hours: The class starts on Saturday 2 nd of April, 2016 Saturdays Only 8:00 AM 4:00 PM Central Standard Time

Overview. Overview. This chapter includes the following sections:

Overview. About the Cisco UCS S3260 System

Cisco UCS Manager Firmware Management Using the CLI, Release 3.1

Cisco Real Exam Questions - Guaranteed

Statistics Collection Policy Configuration

Cisco UCS Manager Firmware Management Guide, Release 3.1

Managing Rack-Mount Servers

Configuring VM-FEX. Information About VM-FEX. VM-FEX Overview. VM-FEX Components. This chapter contains the following sections:

Cisco UCS-Mini with B200 M4 Blade Servers High Capacity/High Performance Citrix Virtual Desktop and App Solutions

Overview. Cisco UCS Manager User Documentation

Cisco UCS Accelerated Accreditation Training

VersaStack for Data Center Design & Implementation (VDCDI) 1.0

Troubleshoot Firmware

Cisco CCIE Data Center Written (Beta) Download Full Version :

Overview of Cisco UCS Manager GUI

Q&As. Troubleshooting Cisco Data Center Infrastructure. Pass Cisco Exam with 100% Guarantee

Cisco UCS Manager Firmware Management Guide, Release 3.2

Service Profiles. Service Profiles in UCS Manager

Exam Questions

Unify Virtual and Physical Networking with Cisco Virtual Interface Card

Maailman paras palvelinjärjestelmä. Tommi Salli Distinguished Engineer

Overview. About the Cisco UCS S3260 System

Configuring Dual-Wire Management

Traffic Monitoring. Traffic Monitoring

Configuring Service Profiles

UCS-ABC. Cisco Unified Computing System Accelerated Boot Camp. Length: 5 Days. Format: Lecture/Lab. Course Version: 5.0. Product Version: 2.

Exam Questions

Cisco UCS Performance Manager

UCS Uplink Ethernet Connection Configuration Example

Troubleshooting the Cisco UCS Compute Deployment BRKCOM Cisco and/or its affiliates. All rights reserved.

Server Pools. Server Pools. Creating or Editing a Server Pool

Configuring Network-Related Policies

"Charting the Course... Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary

Service Profiles and Templates

Cisco Unified Computing Solutions

Techtorial Datová Centra

Configuring Global Service Profiles

Release Notes for Cisco UCS Platform Emulator, Release 2.1(1aPE3)

Recovering a Lost Password

Fibre Channel Zoning

Using VM-FEX. Information About VM-FEX. VN-Link. Send comments to CHAPTER

Cisco UCS Manager Plug-In For Oracle Enterprise Manager 12c Release 3 and 12c Release 4

Global Pools. Server Pools. Creating a Server Pool. This chapter includes the following sections:

Managing Network Adapters

Configuring Service Profiles

Introducing Cisco UCS Central 1.4

UCS Management Deep Dive

UCS C-Series Deployment Options, Best Practice and UCSM Integration

ATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES. Cisco Server and NetApp Storage Implementation

Overview of Cisco UCS Manager GUI

Understanding and Troubleshooting UCS Licensing

Dell EMC. VxBlock and Vblock Systems 540 Administration Guide

Cisco UCS Manager Troubleshooting Reference Guide

UCS Manager Configuration Best Practices (and Quick Start)

Cisco UCS Director UCS Central Management Guide, Release 6.5

About Chassis Manager

Using Advanced Features on Cisco UCS Dan Hanson, Technical Marketing Manager, Data Center Group

Cisco Troubleshooting Cisco Data Center Unified Computing. Download Full Version :

Configuring APIC Accounts

Fabric Failover Scenarios in the Cisco Unified Computing System

Cisco UCS Monitoring Resource Handbook

Configuring the Fabric Interconnects

Configuring Adapter-FEX

Globalization of Local Service Profiles

Introduction to UCS Faults

FCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch

Vendor: Cisco. Exam Code: Exam Name: DCID Designing Cisco Data Center Infrastructure. Version: Demo

Traffic Monitoring and Engineering for UCS

Transcription:

CHAPTER 5 Transient faults can occur during initial set up and discovery or when a server or virtual machine starts up. You can typically ignore these transient faults, as Cisco UCS Manager clears them automatically. This chapter includes the following sections: Initial Setup and Discovery Faults, page 5-1 Virtual Machine Startup Faults, page 5-5 Initial Setup and Discovery Faults describes the transient faults that you may see during the initial setup and discovery process. The Cisco UCS Manager clears these faults. If you see them during the initial setup or discovery process, you can safely ignore these faults. Transient Faults that Occur during Initial Setup and Discovery Process Fault Code Fault Text Description F16581 [FSM:STAGE:RETRY:]: user configuration The FSM could not send the user to secondary(fsm-stage:sam:dme: configuration to the subordinate fabric AaaUserEpUpdateUserEp:SetUserPeer) F16745 F16725 F16580 [FSM:STAGE:RETRY:]: QoS Classification Definition classification configuration on secondary(fsm-stage:sam:dme:qosclassdef initionconfigglobalqos:setpeer) [FSM:STAGE:RETRY:]: VM profile configuration on external VM manager(fsm-stage:sam:dme:vnicprofilese tconfigvmm:setlocal) [FSM:STAGE:RETRY:]: realm configuration to secondary(fsm-stage:sam:dme: AaaRealmUpdateRealm:SetRealmPeer) The FSM could not send the quality of the service configuration to the subordinate cluster The FSM could not send the VM profile configuration to the the subordinate cluster The FSM could not send the security configuration to the subordinate fabric 5-1

Initial Setup and Discovery Faults Chapter 5 Transient Faults that Occur during Initial Setup and Discovery (continued)process Fault Code Fault Text Description (continued) F16724 [FSM:STAGE:RETRY:]: external VM manager The FSM could not send the VM manager configuration on local configuration to the primary fabric fabric(fsm-stage:sam:dme:extvmmepconfig :SetLocal) F16579 F16749 F16749 F16749 F16680 F16579 F16539 F0429 F0400 [FSM:STAGE:RETRY:]: external aaa server configuration to secondary(fsm-stage: sam:dme:aaaepupdateep:seteppeer) [FSM:STAGE:RETRY:]: Uplink eth port configuration on B(FSM-STAGE: sam:dme:swethlanborderdeploy: UpdateConnectivity) [FSM:STAGE:RETRY:]: internal network configuration on B(FSM-STAGE: sam:dme:swaccessdomaindeploy: UpdateConnectivity) [FSM:STAGE:RETRY:]: Uplink fc port configuration on B(FSM-STAGE:sam: dme:swfcsanborderdeploy: UpdateConnectivity) [FSM:STAGE:RETRY:]: Enable virtual interface on local fabric interconnect (FSM-STAGE:sam:dme:MgmtIfEnableVip: Local) [FSM:STAGE:RETRY:]: keyring configuration on secondary(fsm-stage: sam:dme:pkiepupdateep:setkeyringpeer) [FSM:STAGE:RETRY:]: Fabric interconnect mode configuration to primary(fsm-stage: sam:dme:fabriclancloudswitchmode: SwConfigPeer) Fabric Interconnect A, HA functionality not ready Chassis 1 connectivity configuration: un-acknowledged The FSM could not send the security configuration to the subordinate fabric The FSM could not send the eth-uplink configuration to the fabric interconnects during the initial cluster configuration or the setup. The FSM could not send the internal network configuration to the fabric interconnects during the initial cluster The FSM could not send the fibre channel uplink configuration to the fabric interconnects during the initial cluster The FSM could not send the virtual interface configuration to the fabric interconnects during the initial cluster The FSM could not send the security configuration to the subordinate fabric The FSM could not send the end-host mode configuration on to the primary cluster The cluster configuration cannot be completed until the chassis discovery is completed. policy is configured for four links. THe Cisco UCS Manager reacknowledges the chassis to activate the other links. 5-2

Chapter 5 Initial Setup and Discovery Faults Transient Faults that Occur during Initial Setup and Discovery (continued)process Fault Code Fault Text Description (continued) F0401 IOM 1/2 (B) current connectivity does not match discovery policy: unsupported-connectivity policy is configured for four links. The Cisco UCS Manager can clear this fault when the communication is established between the chassis and the fabric interconnect with that link. F0440 F0332 F0277 F0276 Chassis discovery policy conflict: Link IOM 1/2/2 to fabric interconnect B:1/1 not configured AssociatePnuOSLocalDiskConfig fails with Service-Unavailable ether port 1 on fabric interconnect B oper state: link-up, reason: FEX not configured ether port 4 on fabric interconnect B oper state: link-down, reason: Link failure or not-connected policy is configured for four links. Until the discovery is successful with that link, the remaining links cannot be marked as active. The Cisco UCS Manager can clear this fault when the communication is established between the chassis and the fabric interconnect with that link. During discovery, the server association failed due to an error when configuring the local disk controller. The associated remote invocation error code is 4106. policy is configured for four links. Until the discovery is successful with that link, the remaining links cannot be marked as active. One or more of the links on the chassis flapped during the initial discovery. This fault is generated when the link is down during the flapping. F0206 Adapter 1/2/1 is unreachable During discovery, the adapter information cannot be accessed from the server. This fault clears as soon as the information is available. F0283 VIF 1 / 2 B-42/44 down, reason: Bound Physical Interface Down The internal VIF that the Cisco UCS Manager uses during discovery failed. 5-3

Initial Setup and Discovery Faults Chapter 5 Transient Faults that Occur during Initial Setup and Discovery (continued)process Fault Code Fault Text Description (continued) F0367 No link between IOM port 1/1/2 and fabric interconnect A:1/2 The ethernet server ports flapped on the discovery, because the discovery policy was configured for more than one link. The Cisco UCS Manager clears this fault when the initial discovery succeeds with one link and the other links can be marked as active. F0399 F16520 F77960 F0320 F77959 F16406 Current connectivity for chassis 1 does not match discovery policy: unsupported-connectivity [FSM:STAGE:RETRY:]: Identify pre-boot environment agent on server 1/2 (FSM-STAGE:sam:dme:ComputeBlade Discover:PnuOSIdent) [FSM:STAGE:REMOTE-ERROR]: Result: end-point-unavailable Code: unspecified Message: Waiting for BIOS POST Completion information from IBMC(sam:dme:ComputeBladeDiscover: BiosPostCompletion) Server 1/1 (service profile: ) has an invalid FRU: mismatch-identity-unestablishable [FSM:STAGE:REMOTE-ERROR]: Result: unidentified-fail Code: ERR-0505-IBMC-fru-retrieval-error Message: Could not get Fru from 7f060101, dn=fabric/server/chassis-1/slot-1 (sam:dme:fabriccomputeslotepidentify:ex ecutelocal) [FSM:STAGE:RETRY:]: triggering chassis discovery via IOM 1/2(right)(FSM-STAGE:sam:dme:EquipmentI OCardFeConn:DiscoverChassis) policy is configured for four links. Until the discovery is successful with that link, the remaining links cannot be marked as active. The FSM failed to identify the pre-boot environment on the server during discovery. The FSM did not receive a response from the server during discovery and is waiting for the BIOS POST completion information. The Cisco UCS Manager could not identify the FRUs from the servers during initial discovery. The Cisco UCS Manager could not identify the FRUs from the servers during initial discovery. In a cluster configuration, after the Cisco UCS Manager discovers the chassis through the I/O module connected to the primary fabric interconnect, it raises discovery through the I/O module connected to the secondary fabric interconnect. 5-4

Chapter 5 Virtual Machine Startup Faults Virtual Machine Startup Faults When you power on a virtual machine on a server that has network adaptors connected to a distributed virtual wwitch through a port profile, the Events tab of the VMware vcenter may display the following event: Virtual machine powered On with vnics connected to dvports that have a port level configuration, which might be different from the dvport group configuration. If you see this event, you can safely ignore it. 5-5

Virtual Machine Startup Faults Chapter 5 5-6