Product Overview. 50Ω DC to 18 GHz. Rack-Mounted USB & Ethernet Control

With the use of Mini-Circuits low cost Hand-Flex interconnect cables, multiple matrix configurations can be easily created by the user.

Allows user to monitor the exact usage and plan test requirements accordingly.

Allows user to monitor the exact usage and plan test requirements accordingly.

Allows user to monitor the exact usage and plan test requirements accordingly.

Allows user to monitor the exact usage and plan test requirements accordingly.

The UFC-6000 can measure the frequency of a signal from 1 to 6000 MHz. Mini-Circuits

Mini-Circuits RF Switch Control Program for USB RF Switch

Xtra Long Life 10 million cycles USB RF Switch Matrix 50Ω DC to 18 GHz The Big Deal Mechanical SPDT switch box High reliability, 10 million switch cyc

Mini-Circuits 1ST QUARTER 2017 PRODUCT LINE UPDATE TEST SOLUTIONS

RF SP6T Switch Matrix

USB-4SP2T-63H. The Big Deal. Typical Applications. Product Overview. Key Features

USB-1SP8T-63H. The Big Deal Very high isolation, 80 db typ High speed switching, 250 ns typ High power handling, +30 dbm max USB power & control

Modular Test Systems. Test Solutions - Programming Manual. ZTM Series Rack-Mount Modular Test Systems RCM Series Compact Modular Test Systems

Programmable Attenuator

No need for external DC blocking circuitry

Multi-Channel Attenuator

User Guide USB Frequency Counter

ZTVX-Series RF Signal Routing Assembly 2 x N Port Switch Matrix. A Mini-Circuits Self-Contained Integrated Assembly. User s Manual

User Guide USB Solid State RF Switch

Allows full two way communication from any USB or RS232 port to an SPI device.

ZTM2 Series - Modular Test Systems

User Guide USB-SP4T-63 Solid State RF Switch

Multi-Channel Attenuators & Mesh Networks

ZTS Series Solid-State Switch Systems

pickeringtest.com B Microwave Multiplexer Module

Benchtop Test Solutions

40-785B Microwave Multiplexer Module

User Guide. USB Smart Power Sensors. PWR-8GHS-RC MHz PWR-8FS MHz PWR-8GHS MHz. PWR-6GHS MHz. PWR-4GHS 9 khz-4000 MHz

User Guide. USB/I 2 C/SPI/TTL High Isolation Solid State RF Switch Modules

Mini-Circuits Programming Manual For the. USB RF Switch Matrices

Host Controller: HST-4002

User Guide. Integrated Frequency Counter & Power Meter. FCPM-6000RC MHz 50 Ω

User Guide USB, RS232, SPI & Ethernet Programmable Attenuators

Features wideband, 10 to 4200 MHz low insertion loss, 0.6 db typ. feed through terminal per DC port

USB / I 2 C / SPI RF SPDT Switch Electrical 0 to 50 C Parameter Port Conditions Min. Typ. Max. Units Operating Frequency MHz I

Racal Instruments 1257A. Scalable RF Interface Unit. Product Information. The Racal Instruments 1257A is a Commercial-Off-The

Savant Call Server: SCS-3000

Savant Host: HST-4501

H-Series High Isolation Solid State Switches

Allows connecting up to 50 units in series to a single power supply and 3 wire SPI control.

Test Solutions - Programming Manual ZT Series Custom Switch / Attenuator Matrices

Adapter 2.92 mm-f to 2.92 mm-m

Agilent L4445A Microwave Switch/Attenuator Driver

Cisco Prisma II Platform

pickeringtest.com Digital I/O Module With Power Distribution

Savant Host Controller: SVR-4100

DL-HDM44A-H2 Quick Install Guide

Savant Host: SVR-4500S

Prisma II Platform. Optoelectronics

Adapter 3.5mm-F to 3.5mm-M

Conference Table Connectivity Box for A/V - 4K

BRIC MODULE BRIC ANALOG BACKPLANE BUS MATRIX INPUTS DAUGHTER CARD #3 RESOURCE DISTRIBUTOR DAUGHTER CARD #2

Agilent L4433A Dual/Quad 4x8 Reed Matrix

Applications VHF/UHF communication receivers & transmitters. INSERTION LOSS (db) ABOVE 4.8 db. ISOLATION (db) Total Loss 1. Amp. Unbal.

1U Rack-Mount Console with 19" LCD, DVI or VGA

Keysight Technologies L8990M Modular Switch Matrices. Technical Overview

Miniature Matrix: MMA Series Controlled with USB or Ethernet

Agilent U2751A USB Modular Switch Matrix. Data Sheet

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft

Installing the IPS 4345 and IPS 4360

Miniature Matrix: MMC Series Controlled with USB or Ethernet

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

SmartPro 230V 1.5kVA 900W Line-Interactive UPS, 2U Rack/Tower, LCD, USB, DB9, 8 Outlets

DX/256x256 SERIES SOLID STATE DIGITAL SWITCHING SYSTEMS

Series 8000 RF Signal Switch Solution

ThinkRF R5500. Real-Time Spectrum Analyzer 9 khz to 8 GHz / 18 GHz / 27 GHz. Technical Data Sheet Preliminary

Input / Output (IO) Control Boxes

Miniature Matrix: MMB Series Controlled with USB or Ethernet

EMSwitch RF Switch Plug-In Card

24-Port Gigabit Ethernet Switch w/ 12 Outlet PDU, 2 SFP and 8 PoE+ Ports, 120W

SMART Audio classroom amplification systems Model CAS-340

TC-5921A Shield Box. Features. High RF Shielding. Easy Opening/Closing of lid. EMI filters on all Data and DC lines

Features. SC Switch Control Platforn. SC2000, SCX2000, SCP2000 SCM Series Modules

Sympodium Interactive Pen Display

SmartPro 230V 1.5kVA 900W Line-Interactive UPS, 2U Rack/Tower, LCD, USB, DB9, 8 Outlets

RF switch network. RFB 2000, RFC 2010 or 2020

ELECTROMECHANICAL SWITCH MATRICES

Agilent 70612B K18 Switch Matrix

4x4 HDMI Matrix Switcher and HDMI over HDBaseT CAT5 Extender - 230ft (70m) p

DAPserver Manual. Hardware and Software Configuration. Version Microstar Laboratories, Inc.

Series 8000 RF Signal Switch Solution

8 Port Rackmount USB VGA KVM Switch w/ Audio (Audio Cables Included) StarTech ID: SV831DUSBAU

S-Band Redundant LNA Systems

Description. SmartControl with PoE: SSC-P008. Feature Summary. Rear View of SSC-P008

1-Port Serial-to-IP Ethernet Device Server - RS232 - DIN Rail and Surface Mountable - Aluminum

16x16 Modular Matrix Switch VM1600

SmartAudio: SSA Feature Summary

V C ALIANT OMMUNICATIONS. VCL-Gigabit Ethernet over SDH. Product Brochure. Copyright: Valiant Communications Limited U.K. INDIA U.S.A.

Model 707B / 708B Switching Matrix Mainframe Specifications Model 707B Six Slots with Fixed Rack Model 708B Single Slot with Fixed Rack

550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure

NetCom Plus 413 (NetCom 413, NetCom 413 PRO)

DATA SHEET DEVIO SCR-20 CONFERENCING HUB

DFI Redefines Flexibility Through a Series of Modularized Embedded Systems for... Industrial Automation

25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA

TRBOnet Swift Agent A001

InvisaPC. Product Data Sheet OVERVIEW FEATURES

Introducing Next Generation Media Application Server Hardware

2-Port Dual Monitor DVI KVM Switch, TAA, GSA with Audio and USB 2.0 Hub, Cables included

NetCom Plus 411 (NetCom 411, NetCom 411 PRO)

Transcription:

Rack Mount Modular Test System 50Ω DC to 18 GHz The Big Deal Customizable Front Panel Layout USB and Ethernet Control User-Friendly GUI and DLLs Included Fast Turnaround, Within 2 Weeks! Product Overview To simplify and accelerate the development and delivery of custom test solutions, Mini-Circuits developed the ZTM-series of modular test systems. The design consists of a 3U, 19-inch, rack-mountable chassis with six open hardware windows in the front panel, each of which may be outfitted with one of several component choices to meet your system requirements. This modular structure allows a wide variety of custom configurations with exceptionally fast turnaround times within 2 weeks or less! ZTM units may be equipped with your choice of absorptive electromechanical SPDT, SP4T, SP6T, and transfer switches and programmable attenuators with 0 30, 60, 90, 110, and 120 db attenuation range. With the use of Mini-Circuits low cost HandFlex interconnect cables, multiple matrix configurations can be easily created by the user. All models come with USB and Ethernet-TCP/IP (HTTP and Telnet protocols) control options, allowing setup flexibility and easy remote test management. All ZTM modular test systems come supplied with our user-friendly GUI software, API objects for Windows environments, complete programming instructions for 32- and 64-bit Windows and Linux operating systems, user s manual, and all accessories required for immediate use. Key Features Feature User Configurable Test System Fast Delivery Ethernet-TCP/IP-HTTP and Telnet Protocols (Supports DHCP and Static IP) USB HID (Human Interface Device) AC Mains Power Supply GUI software, DLLs, programming instructions, USB & Ethernet cables, and power cord included Advantages Flexible design allows you to specify the exact test system you need without the cost of unnecessary features. Your custom test system will ship within 2 weeks of placing an order, accelerating your project completion time. test racks can be controlled from any Windows, Mac, or Linux computer, or even a mobile device with a network connection and Ethernet-TCP/IP (HTTP or Telnet protocols) support. Using a VPN would allow remote control from anywhere in the world. The can also be controlled via USB connection. Plug-and-Play, no driver required. Compatible with Windows or Linux operating systems using 32 and 64 bit architecture. Compatible with worldwide 110/240V AC power supplies, allowing easy, convenient setup. The comes ready to use out of the box with all software, accessories, and instructions needed for immediate operation included. Page 1 of 5

Rack Mount Modular Test System 50Ω DC to 18 GHz Features 6 customizable hardware windows, each of which can be equipped with your choice of: Up to 2 SPDT mechanical switches (DC to 18 GHz) Up to 2 mechanical transfer switches (DC to 18 GHz) SP4T mechanical switch (DC to 18 GHz) SP6T mechanical switch (DC to 12 GHz) Up to 2 programmable attenuators (0 to 30, 60, 90, or 110 db, 1 to 6000 MHz; or 0 120 db, 1 4000 MHz) Control via USB and Ethernet-TCP/IP (HTTP and Telnet protocols) User-friendly GUI and DLLs included Qualified to 100 million switch cycles Easy maintenance Delivery within 2 weeks from order or less! Applications Automated production testing RF signal path routing Testing cellular systems Simulation of transmission loss Laboratory instrumentation Control systems Model No. Description Price Qty. Modular Test System Contact Sales (1) Included Accessories CBL-3W-US/EU Black 3-prong AC cord (US or EU) 1 USB-CBL-AB-7+ USB cable (6.8 ft.) 1 CBL-RJ45-MM-5+ RJ45 cable (5 ft.) 1 HT-4-SMA SMA cable connector wrench 1 RoHS Compliant See our web site for RoHS Compliance methodologies and qualifications Mini-Circuits GUI (Graphical User Interface) for USB/Ethernet Control For Demo model of any Switch Matrix model select the model name from the drop box and click Start Demo (See user guide for details for details) For programming instructions fo the Switch Matrix see programming guide and AN-49-001 on Mini-Circuits website 1 Windows, Visual Basic, and Visual Studio are registered trademarks of Microsoft Corporation in the United States and other countries. Linux is a registered trademark of Linus Torvalds. LabVIEW and CVI are registered trademarks of National Instruments Corp. Delphi is a registered trademark of Codegear LLC. MATLAB is a registered trademark of MathWorks, Inc. Agilent VEE is a registered trademark of Agilent Technologies, Inc. Neither Mini-Circuits nor the Mini-Circuits USB-1SP4T-A18 are affiliated with or endorsed by the owners of the above referenced trademarks. Mini-Circuits and the Mini-Circuits logo are registered trademarks of Scientific Components Corporation. Rev. 3 ZTM-Series NY 150422 Page 2 of 5

Configuration The test platform contains 6 windows in the front panel. Each of the 6 windows can be populated with your choice of: Up to 2 SPDT mechanical switches (DC to 18 GHz) Up to 2 mechanical transfer switches (DC to 18 GHz) SP4T mechanical switch (DC to 18 GHz) SP6T mechanical switch (DC to 12 GHz) Up to 2 programmable attenuators (0 to 30, 60, 90, or 110 db, 1 to 6000 MHz; or 0 to 120 db, 1 to 4000 MHz) You can specify your system in 3 easy steps using our simple online configuration tool at: www.minicircuits.com/ztm/ztm Step 1: Choose your configuration Step 2: Enter your contact details Step 3: We will be in touch within 24 hours! Alternatively, please contact us to discuss your requirements: Chi Man Shum Lee Whiting Phone: +1 201 647-1615 Phone: +44 1252 832 620 Email: Chiman@minicircuits.com Email: Lee@uk.minicircuits.com Page 3 of 5

Typical Electrical Specifications for Each Switch (at 0 C to 40 C)* Switch Type Model No. Frequency Range (GHz) Insertion Loss (db) Isolation (db) SPDT MSP2TA-18XL+ DC-18 0.2 85 SP4T MSP4TA-18+ DC-18 0.2 85 SP6T MSP6TA-12+ DC-12 0.2 90 Transfer MTS-18XL+ DC-18 0.2 85 Typical Electrical Specifications for Each Attenuator (at 0 C to 40 C)* Attenuation Range (db) Model No. Frequency Range (MHz) Attenuation Resolution (db) 0-30 RUDAT-6000-30 1-6000 0.25 0-60 RUDAT-6000-60 1-6000 0.25 0-90 RUDAT-6000-90 1-6000 0.25 0-110 RUDAT-6000-110 1-6000 0.25 0-120 RUDAT-4000-120 1-4000 0.25 * See individual model data sheets at www.minicircuits.com Page 4 of 5

Minimum Software Requirements Interface Host operating system - USB Control Host operating system - Ethernet Control Hardware Pentium II or better 1 1 Pentium is a registered trademark of Intel Corporation. USB HID or HTTP Get/Post or Telnet Protocols Window 32/64 Bit operating system: Windows 98, Windows XP, Windows Vista, Windows 7, Windows 8 Linux support: 32/64 Bit operating system Any Windows, Mac, or Linux computer with a network port and Ethernet-TCP/IP (HTTP or Telnet protocols) support Front Panel Outline Drawing Mechanical Specifications Case Material Aluminum to be protected from corrosion/rust External 2 handles on the front panel and rear safety block Weight Front panel Rear panel Operating Temperature Control Interface 9.3 lbs (4.22 kg) (subject to configuration) SMA female for all RF connections LED position indicators for RF switch components Power ON/OFF switch with indicator light 110/240V 50/60 Hz AC inlet USB type B connector for local control RJ45 LAN jack for Ethernet control 0 to +45 deg C USB or Ethernet TCP/IP supporting HTTP and TELNET protocols Page 5 of 5