RXM4AB1BD miniature plug-in relay - Zelio RXM - 4 C/O - 24 V DC - 6 A

RXM4AB1MD Miniature Plug-in relay - Zelio RXM 4 C/O 220 V DC 6 A

RXM4AB3BD Miniature Plug-in relay - Zelio RXM 4 C/O 24 V DC 6 A with LED

RPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED

Zelio Relay - plug-in relays

RSB1A160JD interface plug-in relay - Zelio RSB - 1 C/O - 12 V DC - 16 A

Advantages of a Full Featured 700 Series Relay

RPM13F7 power plug-in relay - Zelio RPM - 1 C/O V AC - 15 A - with LED

78 Series Electromechanical Relay Selection Guide

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

RM35LM33MW liquid level control relay RM35-L V AC/DC

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

TeSys IEC Contactors and Overload Relays

RM35TF V AC

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

RM4TR31 three-phase network control relay RM4-T - range V

RM4TA32 three-phase network control relay RM4-T - range V

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RM4JA01F current measurement relay RM4-J - range ma V AC

RM4LA32M liquid level control relay RM4-L V AC

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

XB4BW73731B5 green flush/red projecting illuminated double-headed pushbutton Ø22 1NO+1NC 24V

XB7NA4234 PB - Spring Rtn, red - 1NC -White "STOP"

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RM4JA31M current measurement relay RM4-J - range ma V AC

RM4JA32MW current measurement relay RM4-J - range A V AC DC

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

XB7EV07BP round pilot light Ø 22 - clear - integral LED - 24 V - screw clamp terminals

K1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

Bulletin 700-HA Tube Base Relay

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

K1F006ALH cam switch - 6-pole A - screw mounting

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

Plug-in relays Zelio Relay. A new offer image!

ALLEN BRADLEY RELAY Bulletin 700-HF

XB4BS542 red Ø40 Emergency switching off pushbutton Ø22 latching turn release 1NC

RM17UB3. Price* : USD

XCKL115 limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO

XB7NS8442 Emergency stop Ø 22 - red - mushroom head Ø 40 mm - turn to release - 1 NC

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

RM4UA33M voltage measurement relay RM4-U - range V V AC

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

TeSys contactors From 115 to 2750 A

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

XB4BL Main. Device short name. Fixing collar material. Shape of signaling unit head. Contacts type and composition

Motor protection relays

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

Zelio Control-modular measurement and control relays 1

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

XB5AS8445 red Ø40 Emergency stop, switching off Ø22 trigger latching turn release 1NO+1NC

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE9RA21MW7 off-delay timing relay s V AC -

RM35LM33MW liquid level control relay RM35-L V AC/DC

ZB5FG09 flush mounted selector switch head key pos stay put

K1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

XCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11

K1B004TLH cam switch - 1 pole A - screw mounting

XB4BW73731B5 green flush/red projecting illuminated doubleheaded pushbutton Ø22 1NO+1NC 24V

XCKS141H29 limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20

TeSys D contactors. Selection guide. All types of control system. Rated operational voltage. Rated operational power in AC-3. Auxiliary contacts

Bulletin 700-HL 2-Pole Terminal Block Relay

Latching, Sequence and Impulse Relays Application Data

K1D012ULH cam changeover switch - 2-pole A - screw mounting

XCKP2110N12 limit switch XCKP - metal end plunger - 1NC +1NO - snap - 1/2NPT

XB7NG33 key selector switch - Ø 22 - keylock - 3 positions - 2 NO - Ronis 455 center

VZBs. Power PCB Relay RT2 2 pole 8 A, DC and AC-coil. Features. Contact data

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

Zelio Control Measurement Relays Multifunction 3-phase supply control relays RM17T 00

Miniature PCB Relays A

Harmony XB5S Biometric Switch. Catalog

XCKP2145G11 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - Pg11

RMCN22BD Analog Converter ma - for Zelio Analog

XCKD3918P16EX limit switch XCKD - roller lever - 2NC + NO - ATEX/IECEx

Transcription:

Data Bulletin 0

Introduction or Introduction of the product range The RXM miniature relay range includes: A relays with C/O contacts, 0 A relays with C/O contacts, A relays with C/O contacts and A low level relays with C/O contacts. All these relays have the same dimensions. Sockets with mixed or separate contact terminals. Protection modules (diode, RC circuit or varistor). Metal hold-down clip for all sockets. Plastic hold-down ejector clip for all sockets. -pole bus jumper that can be used on sockets with separate contact terminals in order to simplify wiring when creating a jumper between the coil terminals. Clip-in ID tags for all the sockets except RXZEM. 0 Relay description Spring return push-to-test button for checking contact operation (green: DC coil, red: AC coil). Mechanical relay status indicator. Optional removable lock-down door enables continuous engagement of the contacts for test or maintenance purposes. During normal operation, this lock-down door must always be in the closed position. Bipolar LED indicating the relay status. Removable ID tag for relay identification. our notches for DIN rail mounting adapter or panel mounting adapter with mounting lugs. Eight, eleven or fourteen quick-connect pins. inger grips for easy removal of the relay from a socket. Mounting adapter for direct mounting of the relay on a panel. 0 Mounting adapter for direct mounting of the relay on a DIN rail. Outputs Socket description Sockets with mixed contact terminals () Connection by screw clamp terminals or box lug connector. ourteen female contacts for the relay pins. Location for protection modules. Locking components for plastic and metal hold-down clips. Locating slot for mounting on DIN rail. Two or four mounting holes for panel mounting. Inputs Relay coil terminals Inputs Outputs Sockets with separate contact terminals () Connection by screw connector. Connection by push-in spring clamp terminals. No tool is required to insert the cable. Eight, eleven or fourteen female contacts for the relay pins. Location for protection modules. Locking components for plastic and metal hold-down clips. Locating slot for mounting on DIN rail. Two mounting holes for panel mounting. Location for bus jumpers (see Mounting on Sockets section on www.schneider-electric.com). Location for clip-in ID tag. Relay coil terminals () The inputs are mixed with the relay coil terminals, with the outputs being located on the opposite side of the socket. () The inputs and outputs are separated from the relay coil terminals. page page page page page

General specifications Conforming to standards IEC/EN 0-, UL 0, CSA C- n Product certifications Ambient air temperature around the device Vibration resistance conforming to IEC/EN 00-- Degree of protection Shock resistance conforming to IEC/EN 00-- Protection category Mounting position culus ile E CCN NLDX, NLDX; curus ile E CCN NLDX, NLDX; CSA; CE; Lloyds Register; GOST; RoHS compliant Storage C () - 0 + (-0... +) Operation C () - 0 + (-0... +) In operation gn (...0 Hz), +/- (0... Hz) with and without retention clip Not operating gn (...0 Hz), +/- (0... Hz) with and without retention clip Conforming to IEC/EN 0 In operation Not operating IP 0 0 gn ( ms) with retention clip 0 gn ( ms) with retention clip RT I Any Insulation specifications Rated insulation voltage (Ui) V 0 (IEC), 00 (UL, CSA) Rated impulse withstand voltage (Uimp) kv (./0 ms) for RXM ppppp and RXM ppppp;. (./0 ms) for RXM ppppp Dielectric strength (rms voltage) Between coil/contact Vac 000 Between poles Vac 000 Between contacts Vac 00 Contact specifications Relay type RXM ABppp RXM ABppp RXM ABppp RXM GBppp Number and type of contacts C/O C/O C/O C/O low level Contact materials Ag alloy with Au flash Ag with Au flash - bifurcated Conventional thermal current (Ith) Rated operational current in utilization categories AC- and DC- or ambient temperature y C Conforming to IEC A 0 N.O. 0 N.C. Switching current Minimum ma 0 Switching voltage Maximum V 0 Vac / Vdc (IEC); 00 Vac / 0 Vdc (UL) Minimum V Vdc Vdc Nominal load A at 0 Vac (00K cycles) 0 at 0 Vac (00K cycles) at 0 Vac (00K cycles) at 0 Vac (00K cycles)() (conforming to IEC, resistive, 00K cycles) A at Vdc (00K cycles) 0 at Vdc (00K cycles) at Vdc (00K cycles) at Vdc (00K cycles)() Rated operational current (conforming to UL) Resistive A at Vac (00K cycles) 0 at Vac (00K cycles) at Vac (00K cycles) at Vac (00K cycles)() A at 0 Vac (00K cycles) 0 at 0 Vac (00K cycles) at 0 Vac (00K cycles) at 0 Vdc (00K cycles)() A at 0 Vdc (00K cycles) 0 at 0 Vdc (00K cycles) at 0 Vdc (00K cycles) at 0 Vdc (00K cycles)() Motor hp / at 0 Vac (K cycles) / at 0 Vac (K cycles) / at 0 Vac (K cycles) / at 0 Vac (K cycles)() hp at Vac (K cycles) at Vac (K cycles) / at Vac (K cycles). A LA at 0 Vac Pilot Duty B00 B00 B00 A make, 0. A break, A continuous at 0 Vac() Switching capacity Maximum AC VA 000 00 00 0 DC W 0 Minimum mw 0 Maximum operating rate No-load 000 In operating cycles per hour Under load 00 Utilization coefficient 0 % Mechanical durability Cycles 0 000 000 () When mounted horizontally Electrical durability of contacts Resistive load (AC) Durability (Number of operating cycles) 0 0 D A B C 0 0 Switching capacity (kva) Reduction coefficient for inductive load (AC) (depending on power factor cos j) Reduction coefficient (A) 0, 0, 0, 0, 0, 0, 0, 0, Maximum switching capacity on resistive load (DC) Current c 0 D C 0, 0 0 00 0 00 0 Voltage (Vdc) A B A RXM ABppp B RXM ABppp C RXM ABppp D RXM GBppp Durability (inductive load) = durability (resistive load) x reduction coefficient. page page page page page

(continued) Coil specifications Average consumption AC VA 0.. DC W 0.. Drop-out voltage threshold AC u 0. Uc Operating time (response time) Between coil energization and making of the On-delay contact Between coil de-energization and making of the Off-delay contact DC u 0. Uc AC ms 0 (max.) DC ms 0 (max.) AC ms 0 (max.) DC ms 0 (max.) Control circuit voltage Uc V 0 0 0 0 0 Relay control voltage codes JD BD ED D GD MD DC supply Average resistance at 0 C ± 0% W 0 0 0 0 0 00 Operating voltage limits M Vac... 00 Max. Vac... Relay control voltage codes B E P U AC supply Average resistance at 0 C ± % W 0 0 0 0 Operating voltage limits M Vdc.. Max. Vdc.. Socket specifications Socket type RXZES0M RXZESM RXZESM RXZESS RXZEMM RXZEM Relay types used RXMppppp RXMppppp RXMppppp RXMppppp RXMppppp Contact terminal arrangement Separate Mixed Wire connection method Box lug connectors Spring clamp terminals Product certifications RXMppppp () RXMppppp RXMppppp () RXMppppp Box lug connectors Screw clamp terminals curus ile E CCN SWIV, SWIV; CSA; CE; GOST; Lloyds; RoHS compliant Conforming to standards IEC, UL 0, CSA. No. Electrical specifications Conventional thermal current (Ith) A 0 (-Pole), (-Pole) Maximum operating voltage Vac 0 (IEC) Insulation specifications Between adjacent output contacts Vrms 00 Between input and output contacts Vrms 00 Between contacts and DIN rail Vrms 00 General specifications Ambient air temperature around the device Operation C ( ) - 0 + 0 (- 0 + 0) Storage C ( ) - 0 + (- 0 + ) Degree of protection Conforming to IEC/EN IP 0 0 Connection Solid wire conductor 0.. - AWG 0 AWG 0.. 0.. 0.. without AWG 0 AWG AWG 0 AWG AWG 0 AWG cable end conductors 0.. - AWG 0 AWG lexible conductor 0.. - AWG AWG 0.. 0.. 0. wire with AWG 0 AWG AWG AWG AWG AWG cable end conductors 0. - AWG AWG 0.. AWG 0 AWG 0. - AWG AWG Maximum tightening torque / Screw size Nm / M screw Mounting On DIN rail / on panel Mounting on DIN rail By plastic clip By metal By plastic clip compression spring Terminal referencing IEC, NEMA Bus jumper (Ith: A) Yes No Compatibility with the plastic hold-down Yes ejector clip Compatibility with the metal hold-down clip Yes Protection module compatibility All RXM00W, RXM0pp, RXM0pp Clip-in ID tag compatibility Yes (see page for more information) No Wire connection method Screw connector Spring clamp terminals 0 Screw connector Screw clamp terminals () When mounting relay RXMppppp on socket RXZEMpppp, the thermal current must not exceed 0A.

References RXMABBD RXMAB Miniature relays with lockable test button only (sold in lots of 0) Control circuit voltage Number and type of contacts - Thermal current (Ith) C/O - A C/O - 0 A C/O - A Unit Weight Unit Weight Unit Weight V kg (lb) kg (lb) kg (lb) Vdc RXMABJD 0.0 (0.0) RXMABJD 0.0 (0.0) RXMABJD 0.0 (0.0) Vdc RXMABBD 0.0 (0.0) RXMABBD 0.0 (0.0) RXMABBD 0.0 (0.0) Vdc RXMABED 0.0 (0.0) RXMABED 0.0 (0.0) RXMABED 0.0 (0.0) 0 Vdc RXMABD 0.0 (0.0) RXMABD 0.0 (0.0) RXMABD 0.0 (0.0) 0 Vdc RXMABMD 0.0 (0.0) Vac RXMABB 0.0 (0.0) RXMABB 0.0 (0.0) RXMABB 0.0 (0.0) Vac RXMABE 0.0 (0.0) RXMABE 0.0 (0.0) RXMABE 0.0 (0.0) 0 Vac RXMAB 0.0 (0.0) RXMAB 0.0 (0.0) RXMAB 0.0 (0.0) 0 Vac RXMABP 0.0 (0.0) RXMABP 0.0 (0.0) RXMABP 0.0 (0.0) 0 Vac RXMABU 0.0 (0.0) Miniature relays with LED and lockable test button (sold in lots of 0) Vdc RXMABJD 0.0 (0.0) RXMABJD 0.0 (0.0) RXMABJD 0.0 (0.0) Vdc RXMABBD 0.0 (0.0) RXMABBD 0.0 (0.0) RXMABBD 0.0 (0.0) Vdc RXMABED 0.0 (0.0) RXMABED 0.0 (0.0) RXMABED 0.0 (0.0) 0 Vdc RXMABD 0.0 (0.0) RXMABD 0.0 (0.0) RXMABD 0.0 (0.0) Vdc RXMABGD 0.0 (0.0) RXMABBD Vac RXMABB 0.0 (0.0) RXMABB 0.0 (0.0) RXMABB 0.0 (0.0) Vac RXMABE 0.0 (0.0) RXMABE 0.0 (0.0) RXMABE 0.0 (0.0) 0 Vac RXMAB 0.0 (0.0) RXMAB 0.0 (0.0) RXMAB 0.0 (0.0) 0 Vac RXMABP 0.0 (0.0) RXMABP 0.0 (0.0) RXMABP 0.0 (0.0) RXMAB Miniature relays with LED only (sold in lots of 0) Vdc RXMABJD 0.0 (0.0) RXMABJD 0.0 (0.0) Vdc RXMABBD 0.0 (0.0) RXMABBD 0.0 (0.0) 0 Vdc RXMABD 0.0 (0.0) RXMABD 0.0 (0.0) Vdc RXMABGD 0.0 (0.0) Vac RXMABB 0.0 (0.0) RXMABB 0.0 (0.0) Vac RXMABE 0.0 (0.0) RXMABE 0.0 (0.0) 0 Vac RXMAB 0.0 (0.0) RXMAB 0.0 (0.0) 0 Vac RXMABP 0.0 (0.0) RXMABP 0.0 (0.0) RXMAB page page page page page

References (continued) Miniature relays with low level contacts, lockable test button only (sold in lots of 0) Control circuit voltage Number and type of contacts Thermal current (Ith) C/O - A Unit Weight kg (lb) V Vdc RXMGBJD 0.0 (0.0) Vdc RXMGBBD 0.0 (0.0) Vdc RXMGBED 0.0 (0.0) 0 Vdc RXMGBD 0.0 (0.0) RXMGBBD Vac RXMGBB 0.0 (0.0) Vac RXMGBE 0.0 (0.0) 0 Vac RXMGB 0.0 (0.0) 0 Vac RXMGBP 0.0 (0.0) Miniature relays with low level contacts, with LED and lockable test button (sold in lots of 0) Vdc RXMGBJD 0.0 (0.0) Vdc RXMGBBD 0.0 (0.0) Vdc RXMGBED 0.0 (0.0) 0 Vdc RXMGBD 0.0 (0.0) RXMGBBD Vac RXMGBB 0.0 (0.0) Vac RXMGBE 0.0 (0.0) 0 Vac RXMGB 0.0 (0.0) 0 Vac RXMGBP 0.0 (0.0) 0 Vac RXMGBU 0.0 (0.0) Miniature relays with low level contacts, with LED only (sold in lots of 0) Vdc RXMGBJD 0.0 (0.0) Vdc RXMGBBD 0.0 (0.0) Vdc RXMGBED 0.0 (0.0) 0 Vdc RXMGBD 0.0 (0.0) RXMGB Vac RXMGBB 0.0 (0.0) Vac RXMGBE 0.0 (0.0) 0 Vac RXMGB 0.0 (0.0) 0 Vac RXMGBP 0.0 (0.0) page page page page page

References (continued) Sockets Contact terminal arrangement Connection Relay type Sold in lots of Unit Weight kg (lb) Mixed Screw clamp terminals RXMpppp () 0 RXZEM () 0.0 (0.0) RXMpppp Screw connector RXMpppp () 0 RXZEMM () 0.0 (0.) RXMpppp Separate Spring clamp terminals RXMpppp () 0 RXZESS () 0.00 (0.) RXMpppp Box lug connector RXMpppp 0 RXZES0M () 0.0 (0.) RXMpppp 0 RXZESM () 0.0 (0.) RXMpppp 0 RXZESM () 0.00 (0.) RXZEMM + Relay RXMAB Protection modules Description Voltage or use with V Sold in lots of Unit Weight kg (lb) Diode...0 Vdc All sockets 0 RXM00W 0.00 (0.00) RC circuit...0 Vac All sockets 0 RXM0BN 0.00 (0.0) 0...0 Vac All sockets 0 RXM0U 0.00 (0.0) RXM0pp Varistor... Vac / Vdc All sockets 0 RXM0RB 0.00 (0.00)...0 Vac / Vdc All sockets 0 RXM0BN 0.00 (0.00) 0...0 Vac / Vdc All sockets 0 RXM0P 0.00 (0.00) Timing relays Description or Unit use with or timed C/O contacts Sockets RXZEppppp REXLpp () REXLpp () REXLpp RXZ00 Accessories Description or use with Sold in lots of Unit Weight kg (lb) Metal hold-down clip All sockets 0 RXZ00 0.00 (0.00) Plastic hold-down ejector clip All sockets 0 RXZR 0.00 (0.0) Bus jumper -pole (Ith: A) All sockets with separate contacts 0 RXZS 0.00 (0.0) Mounting adapter for DIN rails () All relays 0 RXZEDA 0.00 (0.00) Mounting adapter All relays 0 RXZEA 0.00 (0.00) with mounting lugs for panel Clip-in ID tags All relays (sheet of 0 legends) 0 RXZL0 0.00 (0.) All sockets except RXZEM and RXZESS 0 RXZL0 0.00 (0.00) RXZESS socket 0 RSZL00 0.00 (0.00) () Thermal current Ith: 0A () Thermal current Ith: A () When mounting relay RXMppppp on socket RXZEMpppp, the thermal current must not exceed 0A. () Please consult the "Zelio Time timing relays" catalog. () Test button becomes inaccessible if used with DIN rail mounting adapter or panel mounting adapter and terminals face the user.

Dimensions Dimensions Miniature relays RXMpppppp RXM RXM RXM Coon view Pin side view.. 0. 0.... 0. 0. 0.. 0.. 0..0.. 0. 0. 0. Sockets RXZEM 0. 0. 0.. 0.0. 0.. 0.0. 0.0 RXZEMM. 0.. 0.0. 0.0. 0.. 0.. 0.0 0. 0. ()..00. 0. ()..0. 0. () 0.. 0. 0. () () 0.. 0. 0.. 0. 0 0. 0... Coon side view RXZES0M RXZESM RXZESM () 0. () () 0.. 0. 0..0 0..0 0. ().. 0.. 0. 0. 0. () ().0.0.0 0. 0. 0. ().. 0.. 0..0. 0..0. 0..0 () Relays () Protection module () Metal hold-down clip () elongated holes Ø. x. () bus jumpers page page page page page

Dimensions (continued) Dimensions (continued) Sockets (continued) RXZESS Socket only RXZESS Socket with RXM relay and retention clip..0... 0.. 0.. 0.0..0..0 () 0. ().0 0. (). 0.0. () () Relay () Protection module () Metal retention clip () I.D. tag.0.0 0.. RXZESS Socket with RXM relay and ejector clip...0 () () () () () Relay () Protection module () Ejector clip () I.D. tag.0.0 0. 0. Plastic ejector clip RXZR Metal retention clip RXZ00 ID tag RSZL00. 0..0 0..0.. 0.. 0. 0. 0.0 page page page page page 0

Dimensions (continued) Dimensions (continued) Plastic hold-down clip and clip-in ID tags RXZR RXZL0 Mounting on all sockets ().,.0, (), Bus jumper RXZS Mounting on sockets with separate contacts (view from below) Example of bus jumper mounting on sockets () Clip-in ID tags for all sockets except RXZEM Metal hold-down clip RXZ00, 0., () (),. () () 0. 0.0 () bus jumpers (polarity ) () bus jumpers (polarity ) Mounting adapter for rails () RXZEDA Mounting adapter for panel RXZEA,, () Test button becomes inaccessible page page page page page

Wiring diagrams Wiring diagrams Miniature relays RXMppppp RXMppppp RXMppppp 0 Symbols shown in black correspond to IEC markings; blue correspond to NEMA markings. Sockets RXZEM RXZEMM RXZES0M 0 0 INPUT Symbols shown in black correspond to IEC markings; blue correspond to NEMA markings. RXZESM RXZESM RXZESS 0 0 INPUT INPUT Symbols shown in black correspond to IEC markings; blue correspond to NEMA markings. Protection modules RXM00W RXM0ppp RXM0ppp + + + page page page page page

Wiring instructions for RXZESS socket Wiring instructions for RXZESS socket Recoended wire strip length Recoended removal tool: flat blade, parallel tip Openings for wiring and removal tool () () ~ 0. ~ 0.. 0.0 () Wiring opening () Removal tool opening Wiring insertion Wiring removal Recoended wiring for RXZESS socket lexible wiring with wire 0. to. 0 to AWG cable end wires 0. to. 0 to AWG Solid wiring without wire 0. to. 0 to AWG cable end wires 0. to. 0 to AWG Note: Allow only one wire per terminal opening Wiring (cable) terminal opening Removal tool opening page page page page page

www.schneider-electric.com Schneider Electric USA, Inc. 00 Knightdale Blvd. Knightdale, NC USA Customer Care Center Tel: -- Schneider Electric Canada McLaughlin Rd. Missassauga, Ontario, Canada LR B Canada Customer Care Center Tel: 00-- The information and dimensions in this catalog are provided for the convenience of our customers. While this information is believed to be accurate, Schneider Electric reserves the right to make updates and changes without prior notification and assumes no liability for any errors or omissions. Zelio, Schneider Electric and logo, and Make the most of your energy are trademarks or registered trademarks of Schneider Electric or its affiliates in the United States and other countries. Other trademarks used herein are the property of their respective owners. Design: Schneider Electric Photos: Schneider Electric 0DB0 0 0 Schneider Electric. All rights reserved. /0