Synchronizing Systems

Similar documents
GC2000 Generator Controller Power Management and Protection

Si-TEC Xtend GSM DATA SHEET. Digital control range for grid parallel/bus tie. Key features. Description

Multiple Generator Automatic Synchronising System

SIGMA. Advanced Generator Protection and Control. Short Form Catalogue

Features. Application range. Si-TEC Xtend Recip interface. Accumulated data recording of engine running hours, kwatt hours, kvar hours, etc.

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC

Comprehensive Modular Genset Controller

Si-TEC Xtend CGC ET DATA SHEET. Digital control range for extraction steam turbines. Key features. Models. Description

You re in Total Command DISCOVER THE AWESOME POWER OF THE ASCO LOW VOLTAGE 7000 SERIES GENERATOR PARALLELING CONTROL SWITCHGEAR

HGM9520 Genset Parallel (With Mains) Unit USER MANUAL. Smartgen Technology

PGC 4000v2 POWER GENERATION CONTROLLER

M2500 Engine Controller Configuration Manual

Operator's manual 4000 Instrumentation en-gb Issue 1.0

Si-TEC Xtend CGC DATA SHEET. Digital control range for steam turbine generators. Key features. Models. Description

reliable company...caterpillar

HGM9510 Genset Parallel (With Genset) Unit USER MANUAL. Smartgen Technology

Option H3 Serial communication Profibus DP

AUTOMATIC TRANSFER SWITCH CC2 & AC5 CONTROL PANELS

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

c InteliGen NTC general purpose HIGH-END gen set controller

GENSYS CORE. Technical Documentation. Core unit for all-in-one. Genset control and paralleling unit. with integrated plc. Chapter : Overview

EMCP 4.4 GENERATOR SET CONTROLLER

Comprehensive Modular Genset Controller

MP7. Uninterruptible Power Supply

Power System Network Simulator (PSNsim)

Technical Specifications. Multi Function Meter

Application Note (Revision NEW) Original Instructions. EGCP-2 Differences

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

paralleling SOLUTIONS

DEIF A/S. Generator Paralleling Controller multi-line L. Type GPC / GS. Compact system in one unit

easygen- 3100XT/3200XT(-LT) Introduction Presentation

MULTI-LINE 2 APPLICATION NOTES. Converting PPU-2 to PPU-3 Parameter conversion Wiring Options I/O list. Document no.: A SW version:

You re in Total Command. Discover the awesome power Series generator paralleling. and communications

Mics KERYS FEATURE MAN-MACHINE INTERFACE MODULARITY / PROTECTION MEASUREMENTS / CONTROL ARCHITECTURE COMMUNICATION PRODUCT PLUS POINTS KER/GB-2004/1

GENSYS 2.0. All-in-one genset control and paralleling unit with integrated PLC. Part Number: A53 Z J-En. Last Update: 13/06/2011

Technical Specifications. Dual Source Energy Meter (EB / DG)

Manual# Manual. LSU 408 Load Share and Synchronizer Unit

SMALL GENERATOR INTERCONNECTION REQUEST. (Application Form)

Series 2400 Paralleling Switchgear

GC2000 Generator Controller Manual

Electronic gen set controllers and auxiliairy devices for Generator Sets SICES SRL

MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES

Power Energy Analyser & Logic Controller Maximum Demand Load Shed Controller 2nd - 40th Voltage & Current Harmonic Analyser

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology

For the State of Washington SMALL GENERATOR INTERCONNECTION REQUEST (Tier 1 [Non-Net Meter], Tier 2, Tier 3) (Application Form)

Power Control Systems

Smart energy meter. Benefits and Features. User Manual Revision English. 103EM series

CVM-B100 CVM-B150 INSTRUCTION MANUAL (M010B B)

SMALL GENERATOR INTERCONNECTION REQUEST (Application Form)

PQM - Power Quality Monitoring

Clink II Integrated Motor Control System

CEM-C6 INSTRUCTION MANUAL (M187B B)

You re in Total Command

ALL-IN-ONE Generator & CHP Control System ALL-IN-ONE MOTORTECH GENERATOR & CHP CONTROL SYSTEM

GS828-H. GPRS Data Logger

DS 500 Intelligent chart recorder for compressed air and gases

Genset Controller Unit Model EMS - GC10. Installation Manual Section

General introduction Part 2, chapter 11

UMG 96RM. UMG 96RM Universal measurement instrument. Areas of application

CLA-VAL Control Panel

IDS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors

U niversal Measuring Device NEW! UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs.

THE RAINBOW SCADA D-700

Power Meter PowerMonitor 500

DATA SHEET. AGC PM Automatic Genset Controller, Plant Management

CPS VS UPS FOR POWERING DATA CENTERS

Product Sheet ECO. Types ECG, AMF Technical data. product sheet eco ecg-amf - technical data gb v1.0.docx

Smart Energy & Power Quality Solutions. UMG 96S Universal flush-mounting measuring instrument

ATS CONTROLLER OPERATING MANUAL

Three Phase UPS Systems

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O

Power analyzer CVM-B100 CVM-B150 INSTRUCTION MANUAL (M010B A) MEASURING EQUIPMENT

PowerWizard 1.1, 1.1+ & & 2.1 Generating Set Control Technical Manual

SCADA Solutions Since 1981 DATA FLOW SYSTEMS

USER MANUAL 2012 V1.1

The bridge between green energy and the power grid CM-UFD grid feeding monitoring relays with Modbus RTU

RCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs

Real-time Power System Operation. Energy Management Systems. Introduction

DNP3 Communications Protocol

Chart recorder. DS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors

ELG4125: System Protection

Installation and Operation Manual DPC1

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DATA SHEET Compact Genset Controller, CGC 200

FP_D.5_EGAT_THE REVAMP OF PARTIAL UPGRADE EXCITATION CONTROL SYSTEM BY USING THE EGAT s INNOVATION (EGAT-AVR)

Smart Energy Meter. Benefits and Main Features. User Manual Revision English OB (100)A

GENSYS 2.0 GENSYS 2.0 CORE GENSYS 2.0 LT

FG Wilson Control Systems

PM130 Powermeters Reference Guide Modbus Communications Protocol

HT-DST4602 Evolution. Genset Controller. AMF and PARALLEL genset controller. Parallel Applications HUEGLI TECH SWITZERLAND

HGM7200/HGM7100A Series Automatic Genset Controller User Manual Smartgen Technology

HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL

IDS 500 mobile Intelligent mobile chart recorder

Smart Power Flow Monitoring and Control

Lowering Lifecycle Costs

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

M2500 Engine Controller Operator Manual

EMS-GC10 Genset Controller. Modbus Communication Mapping Manual Section 75

EnerSure Installation Guide

Transcription:

Synchronizing Systems AGN Technology brings alternative solution to energy projects by using synchronizing systems. With combining more than one generator for your high KVA needs, this system provides significant advantages comparing against single generator with same power. Especially the synchronization panel that design by AGN Technology engineers offers integrated solution through customers with its technology. AGN Technology developed lower priced systems and show its difference by using its technical expertness, global resources and its production methods for obtaining high energies with synchronization of more the one generator against all kinds of scenarios. More generators far more advantage: The system that is using synchronization generator has much more advantages than using one high power generator. These are: Lower cost Cost comparison Lower first investment budget Flexible usage Sustainable and reliable system Easier service and maintenance Easier delivery and maintain spare parts Lower cost: Synchronization systems with its other advantages present a serious price advantages comparing against one high power generator. The engine manufactures, the engine that have power up to 625 KVA own a winder usage area. Because of its wide usage in work machines, Lorries and trucks, they have much more production numbers, and there assembly line designed for mass production which creates lower prices than high power engines. The high power engines mostly use in specific project which decrease their production numbers and increase their cost. If you look at the chart you will see the most economic power interval is in 300KVA-800KVA. Because the high demand of these models, production line is adjusted for these models which decrease their production costs. The synchronization systems lower cost also eligible for its 30000 25000 20000 15000 10000 spare parts and expenditure necessaries. With a result of the high power engines mostly worked under recommended power load, some serious problems appear. These problem increase maintenance cost and smaller generator life. With its flexible work load logic synchronization systems prevent problems and minimize maintenance cost. AGN Technology synchronization systems bring 15% to 20% price advantages in first investment cost and also operational spending. K V A C O S T 5000 0 KVA 0 500 1000 1500 2000

Cost comparison: As you can see the comparative cost graphic the synchronization systems which gathered from different KVA models bring more advantages both in purchase and also after sale. 250 200 Series 1 represents the cost of synchronization systems for same 2200 KVA power (4x625KVA=2500KVA) Series 2 represents the cost of one single generator for same 2200KVA power. 150 100 50 0 500 600 800 1000 1200 1400 1600 1800 2000 2200 Series 1 Series 2 Cost Comparison between approximately 2200KVA Synchronization system and single generator with same power. 120 100 80 60 40 20 0 2200 KVA 4*625=2500 KVA 120 100 80 60 40 20 0 2200 KVA 4*625=2500 KVA Maintenance Cost Investment cost Lower first investment budget: In the investments that predict a fast growth, purchasing a high power generator at establishment increases the first investment budget. By preferring AGN Technology synchronized systems you can start by purchasing lower power generator which decreases the first investment budget. According to the growth rate you can add generator in various numbers and powers which establish a problem free, flexible system.

Flexible usage: We can approach to flexible usage of AGN Technology synchronization systems from both logistic and functional point of view. 2000 1500 P KVA 500 Time On the contrary of common belief synchronization system can be synchronized not just in equal powered generators but also be different powered models. As a result of this application a flexible solution is created for changing power at different time a day. In a hotel that need intense power at summer time, is not also going to need some power at winter time. With the synchronization of different powered generators the intense power need of summer cover by high and small generator synchronize on the other hand you can use the lowered power single generator according to complete the power for the off seasons. Thus fuel expenditures and corrosion are minimized. In logical point of view, multiple generator systems create substantial advantages for difficulties about setting up systems against single large generators. The synchronization generators are smaller and lighter so this create an advantage about set ups. AGN Technology does not have to positioning units side by side. Because of this there will be serious advantages by positioning units in different small rooms and connecting them with wire in common feeding line. Sustainable & reliable system: If you think about continuity of energy synchronization systems offers more sustainable and reliable than single generator. If any reason if one generator shutdown you can continue to nurture critical energy needs with load take/give system. Easier service and maintenance: With the standard co-aging process in multiple generator systems, every generator working time decreases. With this process the synchronized systems utilization time and revision periods increase but execution and maintenance cost decrease. Synchronization systems also create flexibility at after sale service. In these systems generators can be taking into services while they are still operating. With right scheduling for determining lower workload period, power cuts which caused from maintenance service can prevent. Power cuts can also prevent by shutting one generator and giving the critical load to other synchronization generator. Easier delivery and maintain spare parts: Higher powered generators have much longer delivery time because they manufactured only by special order and limited manufacturer numbers. Serial production engines high demand numbers and their big stocks make easier for short time deliveries.

APPLICATIONS Multiple generator application for prime power: In a situation that there is no network energy, two or more synchronization generators feed energy loads constantly and these loads divided among generators by their power ratios. Generator sets allow for economic usage by switching on or off according for the energy needs Multiple generator application for standby power: When the mains energy crosses its limits two or more synchronized generators feed energy loads by their power ratio. After the mains power stabilized energy loads transfer to mains step by step. Soft transfer: When the mains energy crosses its limits two or more synchronized generators feed energy loads by their power ratio. Generator sets switching on and off according to economical usage of management's workload. If the mains energy becomes useable again than the control system will be synchronized generator or generator sets with system. In short notice synchronized systems uninterruptedly transfers its load to the mains with a platform. This procedure is mostly needed when a system in an energy production stations demands power restoration after its collapse (trip). Generator or generator sets feed station furnishings; after the station starts to produce energy, it transfers it s with soft transfer. This application has known as "black start". Constant parallel working: Because of distribution company's change of tariffs during a day, performing high price tariff if the assessment value crossed or forced to limiting electrical energy as a result of inadequate groundwork; staying in constant parallel working with network could be advantageous for customers. There are some different working methods for parallel working. One of them is base load peak lopping in which active load supplied by generator system at intended power factor and other by mains system. This system is very popular among cogeneration systems which prefer constant load. Another method is true peak lopping in which power that supplied from network limited and upper power of this limitation supplied from generator. This method is mostly using in when the tariff price for an upper limits of a specific power is too high or when the supplied power is limited.

Multiple mains: In the managements with two or more mains when the mains system collapses generator system become synchronized and start to feed load. To feed load from single bar which feed from two transformers, coupling cutters is shouted down. When the mains connected with bus-bar then the load transfer to this mains transmission line AGN Technology synchronization control: AGN Technology uses its own designed synchronization control panel in generator sets for synchronization and sharing workload. For different synchronization application AGN Technology the following solutions are offered Multiple generator sets synchronization between them (ATSP09 x generator number) One generator sets synchronization with network (ATSP08) Multiple generator sets synchronization with network (ATSP09 x generator number + ATSP08) Multiple generators sets synchronization with multiple network (ATSP09 x generator number + ATSP x network number)

ATSP09 SYNCHRONIZATION CONTROL PANEL SPECIFICATIONS Load properties: Automatic and manual synchronization Can synchronized until 10 generators among themselves and feed the workload Load sharing at generators according to power Automatically start and stop according to load Automatically balancing work hours (co-aging) Communication properties: Communication over (AQ) bus-bar with electronic engine control units (optional) Alarm message with SMS (optional) Open communication over RS 232 or RS 485 interface Support Motbus RTU protocol (concordant with scada system) Indicator properties: LCD text indicator All engine and alternator parameters can be watched Engine and alternator protection Keep the records of generator alarms, last 25 records Expansion modules (in and out) With LCD screen in ATSP09 synchronization panels you can measure the following rates and with the stated protection, system reliability put in first place. MEASUREMENTS Direct measures: Oil pressure Coolant temperature Fuel level (optional) Oil temperature (optional) Accumulator voltage Engine circulation Generator frequency Generator phase-neutral voltage Generator inter-phase voltage Generator phase current Generator earth current (optional) Generator phase sequence Expandable measurements: Generator total active power (KW) Generator total visible power (KVA) Generator total reactive power (KVAr) Generator average power factor (cosφ)

Hidden measurements: Actual time Left time for the next (maintenance) Generator positive KWh Generator negative KWh Generator KVAh Generator KVArh Number of starter Maximum positive vector slide Maximum negative vector slide SYNCHRONIZATION CONTROL PANEL PROTECTION SYSTEM Engine protection: Low oil pressure High coolant water temperature High oil temperature (optional) Low/high frequency cycle Battery charger rectifier error Low/high accumulator voltage Low/high fuel level (optional) Alternator protection: Low/high voltage Low/high frequency Extreme voltage Earthling error (optional) Reverse power Wrong phase rotation of alternator Excitation loss Circuit breaker protection: Generator switching off error Generator switching on error ATSP08 SYNCHRONIZATION CONTROL PANEL SPECIFICATION Load properties: Automatic and manual synchronization Synchronization with mains Workload sharing with peak topping or stable workload methods while working parallel with network Automatic starting of stopping according to load Automatically balancing work hours (co-aging) Communication properties: Communication over (AQ) bus with electronic engine control units (optional) Alarm message with SMS (optional) Open communication over RS 232 or RS 485 interface Support Motbus RTU protocol (concordant with scada system)

Indicator properties: LCD text indicator All engine and alternator parameters can be watched Engine and alternator protection Keep the records of generator alarms, last 25 records Expansion modules (in and out) With LCD screen in T JPS20 synchronization panels you can measure the following rates and with the stated protection, system reliability put in first place. MEASUREMENT SYSTEM Direct measures: Oil pressure Coolant temperature Fuel level (optional) Oil temperature (optional) Battery charger rectifier voltage Accumulator voltage Engine circulation Generator frequency Generator phase-neutral voltage Generator inter-phase voltage Generator phase current Generator earth current (optional) Generator active power by each phase (kw) Mains frequency Mains phase-neutral voltage Mains inter-phase voltage Expendable measurements: Generator total active power (KW) Generator total visible power (KVA) Generator total reactive power (KVAr) Generator power factor per phase (cosφ) Generator average power factor (cosφ) Network total active power (KW) Network total visible power (KVA) Network total reactive power (KVAr) Network power factor per phase (cosφ) Network average power factor (cosφ) Hidden Measurements: Actual time Left time for the next maintenance Generator positive kwh Generator negative kwh Generator KVAh Generator KVArh Number of starter Maximum positive vector slide Maximum negative vector slide

PROTECTION SYSTEM Network protection: Mains G59 low frequency Mains G59 high frequency Mains G59 low voltage Mains G59 high voltage Mains G59 trip Mains low/high voltage Mains error Mains wrong phase rotation direction Engine protection: Low oil pressure High coolant water temperature High oil temperature (optional) Low/high cycle Battery charger rectifier error Low/high accumulator voltage Low/high fuel level Alternator protection: Low/high voltage Low/high frequency Extreme voltage Earthling error Reverse power Wrong cycling direction of alternator Excitation loss Circuit breaker protection: Generator switching off error Mains switching off error Generator switching on error Mains Switching on error ATSP09 + ATSP08 SYNCHRONIZATION CONTROL PANEL SPECIFICATION WORK LOAD PROPERTIES Automatic and manual synchronization In a system that generator and mains numbers limited with 20, it can synchronized with 10 generator and 10 network Load share among generators according to power and load share among generators while they are parallel situation with network with methods of stable load or puzzle lapping Automatic starting of stopping according to load Automatically balancing work hours (co-aging) Communication properties: Communication over (AO) bus with electronic engine control units (optional) Alarm message with SMS (optional) Open communication over RS 232 or RS 485 interface Support Motbus RTU protocol (concordant with scada system)

Indicator properties: LCD text indicator All engine and alternator parameters can be watched Engine and alternator protection Keep the records of generator alarms, last 25 records Expansion modules (in and out) With LCD screen in ATSP09 + ATSP08 synchronization panels you can measure the following rates and with the stated protection, system reliability put in first place. MEASUREMENT SYSTEMS Direct measures: Oil pressure Coolant temperature Fuel level (optional) Oil temperature Accumulator voltage Engine circulation Generator frequency Generator phase-neutral voltage Generator inter-phase voltage Generator phase streams Generator earth stream (optional) Mains frequency Mains phase-neutral voltage Mains inter-phase voltage Mains phase streams Mains earth stream Generator earth stream leak Generator phase line Mains phase line Bus-bar phase-neural voltage Bus-bar inter-phase voltage Bus-bar phase current Bus-bar active power per phase (KW) Derive measures: Generator total active power (KW) Generator total visible power (KVA) Generator total reactive power (KVAr) Generator average power factor (cosφ) Mains total active power (KW) Mains total visible power (KVA) Mains total reactive power (KVAr) Mains power factor per phase (cosφ) Mains average power factor (cosφ) Bus-bar total active power (KW) Bus-bar total visible power (KVA) Bus-bar total reactive power (KVAr) Load total active power (KW)

Load total reactive power (KVAr) Hidden measures: Actual time Left time for the next maintenance Generator positive kwh Generator negative kwh Generator KVAh Generator KVArh Number of starter Mains positive kwh Mains negative kwh Mains KVAh Mains KVArh Bus-bar positive kwh Bus-bar negative kwh Bus-bar KVAh Bus-bar KVArh Maximum positive network ROCOF Maximum negative network ROCOF Maximum positive vector slide Maximum negative vector slide PROTECTION SYSTEMS Network protection: Mains active power limit Mains G59 low frequency Mains G59 high frequency Mains G59 low voltage Mains G59 high voltage Mains G59 trip Mains low/high voltage Mains low/high frequency Mains error Mains wrong phase rotation Engine protection: Low oil pressure High coolant water temperature High oil temperature (optional) Low/high cycle Battery charger rectifier error Low/high accumulator voltage Low/high fuel level Alternator protection: Low/high voltage Low/high frequency Extreme voltage Earthling error Reverse power

Wrong phase rotation of alternator Excitation loss Circuit breaker protection: Generator switching off error Network switching off error Generator switching on error Mains switching on error Bus switching off error Bus switching on error LOAD SHEARING UNIT CONFIGURATION C6200 is designed for installation in electrical switch board panels. The sturdy aluminum casing furnishes clear LED indication and easy accessible connection terminals. C6200 offers the following functionality: Automatic synchronizing Load sharing (active/reactive) Detection of reverse power Detection of excitation loss Programmable I/O ROCOF relay Vector shift relay Frequency monitoring Direct control of electronic speed governors and AVRs C6200 is also equipped with a built-in synchroscope convenient in service and commissioning situations. The C6200 furthermore provides various interface options such as MODBUS for external PC and PLC control and 10 User configurable digital and analogue inputs and outputs that can be set for designated extended functionality. C6200 is a generator controller comprising auto synchronizing, load sharing and versatile interfacing to speed governors and AVRs in one single unit. APPLICATIONS: The C6200 is a cost effective solution for grid-parallel generator operation. The unit is well suitable for use in: Co-generation applications including peak shaving or base load operation in heavy energy consuming industries, like oil refineries, petrochemical refineries, steel mills, mines, cement factories, food processing, etc. Back-up power systems where down-time is critical for safety or economic reasons, like in hospitals, airports, cable ways, energy generation and distribution, processing of food and pharmaceutical products, storage of food and pharmaceutical products, etc. Container enclosure gen-sets offered by rental companies for temporary use.

Speed control, voltage control: C6200 can control speed governors and automatic voltage regulators (AVR) by speed/ voltage up/down pulses, analogue voltage and current signals and pulse width modulated signals PWM. Synchronizing: C6200 is equipped with a built-in synchroscope for manual or semi-automatic synchronization, convenient for service and commissioning situations. Automatic synchronization is a standard function of C6200. It is possible to synchronize complete bus bar sections to each other. Voltage matching and frequency control: C6200 can control both voltage and frequency of the generator. Active load (KW) sharing: Control parallel operation of generators. The unit can run in parallel with other generators controlled by SELCO C6200 Reactive (KVAr) load sharing: Reactive load sharing between generators controlled by SELCO c6200.. Generator protection: Reverse Power Protection and loss of excitation protection are standard features of C6200. For grid parallel operation a vector shift or ROCOF protection can be activated. Load depending start and stop: C6200 offers 8 programmable inputs and outputs. The outputs can be programmed to load depending start and stop functions. In case the load of the running generator increases above a predefined limit, the next available generator will be started. In case the load drops below a predefined limit, the next generator will be stopped. The specific generator priority is given by external selector switch on inputs 1-4.

Operation of generators running in parallel with the grid active load (KW) control: During grid parallel operation the load of the generators can be controlled without additional equipment. Both peak shaving and base load of the generator are possible. In peak shaving mode load depending start and stop is also available. Reactive load (KVAr) control: C6200 offers power factor control. During grid parallel operation the power factor of the generator can be kept constant. The C6200 includes predefined import/export load control schemes that can be activated/ deactivated from the programmable inputs, so generators that sometimes run island mode and sometimes in parallel with the grid can easily be controlled with almost no additional wiring. Analogue outputs: Two analogue outputs are available and can be configured as measurement transducer outputs. Any of the measurements can be connected to these outputs. Rs485 Modbus communication: The C6200 includes RS485 Modbus interface, enabling external control by PC or PLC systems.