Product Tests Report

Similar documents
Product Tests Report

SAM Listed LED Optimized Drivers. Environmental. Electrical Specifications at 25 O C E Output Current. Voltage Accuracy

SAM Listed LED Optimized Drivers. Environmental. Electrical Specifications at 25 O C E Output Current. Voltage Accuracy

SAM Listed LED Optimized Drivers. Environmental. Electrical Specifications at 25 O C E Output Current. Voltage Accuracy

Environmental. Electrical Specifications at 25 O C E Output Constant Current

Environmental. Electrical Specifications at 25 O C E Output Constant Current

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

Safety Standards. Model Number: Unit Weight:

Solid State Battery Fuel Gauge

Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

Power Factor Model Number Voltage Voltage

Sync DIN Rail Power Supply 5V 15W 1 Phase (NEC Class 2) / DRS-5V30W1NZ

ENGINEERING SPECIFICATION SHEET SPEC. Revision History

Safety Standards. Model Number:

Safety Standards. Model Number:

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch)

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

350A Series MDS 350 A D 701 A A. Technical Datasheet Medical ATX Power Supply ATX 12V 1U Power Supply

Safety Standards. Model Number:

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

Safety Standards. Model Number:

Specifications and Part Numbers

RT7-48V/6kW Specification

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Environmental. Electrical Specifications at 25 O C. Programmable Maximum Value. Factory Default

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

ENGINEERING SPECIFICATION SHEET. Table of Contents 1 SCOPE ELECTRICAL SPECIFICATION...5

ANSI-ASQ National Accreditation Board/ACLASS

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

DDR-120 series. 120W DIN Rail Type DC-DC Converter

Specification For 90 Watts Adapter Power Supply Model No: ADB002 Customer ID: 000G Revision: 4.0

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Safety Standards. Model Number:

Environmental. Electrical Specifications at 25 O C. Programmable Maximum Value. Factory Default

Features. Applications and Benefits TRC ELECTRONICS, INC

Safety Standards. Model Number:

Safety Standards. Model Number:

ControlNet-to-DeviceNet Linking Device

Safety Standards. Model Number:

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

Gelo LED Driver 100W, Single output RGLD100-24

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

Universal input VAC <150mW No load power consumption

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Safety Standards. Model Number:

Safety Standards. Model Number:

Proven Industrial Reliability for Mission-critical Communications

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Parameter Condition Min. Typ. Max. Internal Input Filter. nom. Vin = 230VDC 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

PMC. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMC-12V060W1NA Vac ( Vdc) 12Vdc 5.

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24

RT12-240V/2.4kW Rectifier Specification

ArmorPoint I/O Field Potential Distributor, Series A

PMT. Safety Standards. Model Number:

Safety Standards. Model Number:

Output Voltage* (nom.)(adjustable)

Safety Standards. Model Number:

TU531, TU532 Terminal Unit

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Chrome DIN Rail Power Supply 12V 72W 1 Phase (Class II) / DRC-12V100W1AZ

Universal input VAC <250mW No load power consumption -25 C to +80 C Operating temperature, with derating

ORDERING INFORMATION SEE PAGE 6

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Series Specifications Ta= 25 C, nom. Vin, full load and after warm-up unless otherwise stated) Parameter Condition Min. Typ. Max.

Chrome DIN Rail Power Supply 12V 25W 1 Phase (Class II & NEC Class 2) / DRC-12V30W1A

DDR-120 series. 120W DIN Rail Type DC-DC Converter

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

Chrome DIN Rail Power Supply 24V 60W 1 Phase (Class II & NEC Class 2) / DRC-24V60W1A

Series AMEPR30D-AZ up to 2A AC-DC LED driver

IEC/EN/UL60950 & CE certified, EN55032 Class B

Model Number: Model Number Input Voltage Range Output Voltage Output Current PMC-24V100W1AX Vac ( Vdc) 24Vdc 4.17A

Efficiency (1) 110Vac 220Vac. (2, 3) 3330 ma 90 ~ 305 Vac 11 Vdc 35 W 84% EUC-040S333DS(6) EUC-040S333PS(6)

Output Voltage in Constant Voltage Mode. Model Number

SAMSUNG ELECTRO-MECHANICS CO., LTD

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

TF501, TF521 Terminal Bases

PMC. PMC Panel Mount Power Supply 24V 50W 1 Phase / PMC-24V050W1A. Highlights & Features. Safety Standards. Model Number: General Description

KEPCO GIVES YOU ZERO-UP PROGRAMMABILITY IN AN AFFORDABLE POWER MODULE

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

LED55WPG Programmable LED Driver

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

PRODUCT SPECIFICATION File: EA-A0601HE-12 Model: SSA-0601HE-12 Date: Apr. 17, 2015

Revision Issue Date Pages Affected A0 08/14/2006 ALL Modify From CP-8120 Specification Rev:ED by Customer given.

RT4B-110V/12A RECTIFIER

Efficiency (1) 110Vac 220Vac

CliQ DIN Rail Power Supply 24V 60W 1 Phase / DRP024V060W1AZ

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

Sync DIN Rail Power Supply 24V 50W 1 Phase (NEC Class 2) / DRS-24V50W1N

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

Output Voltage* (nom.)(adjustable)

Safety Standards. Model Number:

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1AZ

Note1: Typ. efficiency is 230VAC and full load 12VDC 24VDC 48VDC ms 8ms 16ms 80ms

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

Transcription:

TO WHOM IT MAY CONCERN Page: 1 of 5 Product Tests Report Product name: MIC IP dynamic 7000 HD Camera Model number and description: MIC-7230-PB4 MIC IP dynamic 7000 HD 30x D/N PTZ Camera, Black MIC-7230-PW4 MIC IP dynamic 7000 HD 30x D/N PTZ Camera, White MIC-7230-PG4 MIC IP dynamic 7000 HD 30x D/N PTZ Camera, Grey MIC-ILB-100 Illuminator, IR/White light combo, Black MIC-ILW-100 Illuminator, IR/White light combo, White MIC-ILG-100 Illuminator, IR/White light combo, Grey MIC-67SUNSHLD Sunshield for MIC7000 cameras The above-mentioned Bosch product has been tested in accordance and was found to comply with the tests listed below which were carried out during the development phase of the product. Please note that for some tests, test conditions exceed the range that Bosch recommends for effective continuous operation of the camera. Data subject to change without notice. ENVIRONMENTAL TEST BS EN 50130-5:1999 Alarm systems Part 5: Environmental test methods Dry heat Operational IEC 60068-2-2:1974 +A1:1993+ A2:1994 Dry heat Storage IEC 60068-2-2:1974 +A1:1993+ A2:1994 Specific Test Description (Temperatures stated are outside of the camera housing) Temp. +65 C, duration 48 hours Temp. +75 C, duration 4 hours Temp. -45 C, duration 48 hours Cold operational IEC 60068-2-1:1990 +A1:1993+ A2:1994 Cold start test Power off, soak overnight (8 hours) @ -45 C, power up unit, unit must power up & function normally within < 30 minutes. Cold Endurance IEC 60068-2-1:1990 +A1:1993+ A2:1994 Humidity, operational Damp heat, steady state operational IEC 60068-2-2:1988 IEC 60529 Ingress Protection Rating (IPxx) Degrees of protection provided by enclosures (IP Code) [Dust, water ingress (operational)] IEC 60529 Ingress Protection Rating (IPxx) Degrees of protection provided by enclosures (IP Code) [Dust, water ingress (operational)] UL Type rating (similar to NEMA XX) Salt Spray ASTM B117 standard for corrosion resistance Temp -45 C, Duration 4 hours 65 C / 95 %RH for 6 hours, 35 ⁰C/85% RH for 16 hours. Repeat for 5 cycles total. (Camera with mounting adaptor) Dust tight (no dust ingress; complete protection against contact). Water immersion: 24 hours Water depth: 1.8 meters (Camera without mounting adaptor; exposed connectors in base of camera) Dust tight (no dust ingress; complete protection against contact). Water immersion: 30 minutes Water depth: 1 meter Water immersion: 24 hours Water depth: 1.8 meters Corrosion: 200 hour salt spray IP68 IP67 Type 6P (UL) 2000 hrs at 35 C, 95%RH, 5% NaCl Page 1 of 5

TO WHOM IT MAY CONCERN Page: 2 of 5 BS EN 50130-5:1999 Alarm systems Part 5: Environmental test methods External Mechanical Impact (IK Code) IK## Rating [ Vandalism-proof test ] IEC 62262:2002-02 Vibration sinusoidal operational IEC 60068-2-6:1995 Test Fc: 10 m/s² (1.0 g) Sinusoidal vibration test IAW MIL-STD-167-1A Specific Test Description (Temperatures stated are outside of the camera housing) Energy 20J, 5.05 kg steel mass test slug, 50 mm striking radius, drop height 0.4037 m 5 drops per side, impact 5 sides, 25 total impacts Excludes window. Freq. Range 10-150Hz, 20m/s², 3 axes, sweep rate 1 octave/m 20 sweeps/axis, (2.0g) Exploratory Test 4Hz 25Hz @.01-in single amplitude (.02-in DAD) 1Hz frequency intervals for (15) second dwells. IK10 Fully functional after all impacts and cycling power Variable Frequency Test 4Hz 15Hz @.03- in single amplitude (.06-in DAD) 16Hz 25Hz @.02-in single amplitude (.04- in DAD) 1Hz frequency intervals for (5) minute dwells. Shock operational IEC 60068-2-27:1987 Medium weight Hammer Shock IAW MIL-S-901D Endurance Testing 25Hz @.02-in single amplitude (.04-in DAD) The duration of Endurance Testing is to be 2 hours total, and should be performed at each frequency of prominence identified in the Exploratory and Variable Freq Tests previously performed Half sine wave 11 ms pulse width, 30g 400 m/s² (40 g) Equipment class I, Shock test type A, grade A & B Wind speed (150mph wind tunnel test) (MIC7000 camera only, MIC sunshield, Illuminator and MIC7000 illuminator) Sustained 120-150 mph winds for a 40 minute period without structural damage or loss of video or PTZ function. Sound level (audible noise) < 65 db Transportation Tests (ISTA Procedure 1A) Transportation Tests (ISTA Procedure 1A) ISTA Vibration 14,200 vibratory shocks 2 axis ISTA 36 inches (0.9 m) free fall drop 6 faces of box ADDITIONAL CERTIFICATIONS Functional tests description Description SMPTE 274M-2008 Standard Resolution: 1920x1080 For HD cameras Scan: Progressive 1920 x 1080 Image Sample Structure, Digital Color representation: Representation and Digital Timing Reference complies with ITU-R BT.709 Sequences for Multiple Picture Rates Aspect ratio: 16:9 SMPTE 296M-2001 Standard 1280 x 720 Progressive Image Sample Structure Analogue and Digital Representation and Analogue Interface Conformant with NTCIP protocols 1205, 2301, 1101:1996, 2202:2001, 2101:2001, 2102:2003 Frame rate: 25 and 30 frames/s Resolution: 1280x720 Scan: Progressive Color representation: complies with ITU-R BT.709 Aspect ratio: 16:9 Frame rate: 25, 30, 50 and 60 frames/s For HD cameras Page 2 of 5

TO WHOM IT MAY CONCERN Page: 3 of 5 Conformant with Open Network Video Interface Forum (ONVIF) Interoperability between network video products, regardless of manufacturer ADDITIONAL ENVIRONMENTAL FUNCTIONAL BOSCH TESTS Environmental test methods Specific Test Description MTBF calculation of used components MIC7000 camera only: MTBF 91,000 hours Camera + illuminator: MTBF 80,000 hours Based on: for electronics, MIL-HDBK-217FN1, GB, GC, 25C. HALT (Highly Accelerated Life Test) Ambient Operational Test: +25 C Completed: 11/26/2013 HALT LOL/UOL Voltage Test: 1 - Step mains voltage down from nominal 24VAC by 2 volts every 5 minutes until operational failure and/or destruct failure. Completed: 01/22/2014* 2 - Step mains voltage up from nominal 24 VAC by 2 volts every 5 minutes until operational failure and/or destruct failure. Completed: 01/24/2014* HALT LOL/UOL Temperature Test: 1 - Step temperature down from -40 C by 5 C every 4 hours (minimum) until operational failure and/or destruct failure. Completed: 01/16/2014* 2 - Step temperature up from +40 C by 5 C every 4 hours (minimum) until operational failure and/or destruct failure. Completed: 01/23/2014* HALT Vibration Test: 1 - The DUT is initially vibrated at acceleration level of 5g (rms) for minimum period of at least 10 minutes. After 10 minutes exposure, the DUT is tested operationally and results are recorded. The operating vibration level is then increased by 5g (rms) and the process is repeated for the next step in the test. This sequence is repeated until the DUT fails operational testing or the test level reaches 50g (rms). Completed: 02/28/2014 COLD Start Test: 1 - Set chamber temperature at -45 C. Power removed from test unit for minimum period of 5 hours, then operate the test switch to restore power. The test unit shall complete its start-up sequence and then resume operation. Completed: 11/27/2013 TS 2 Section 2.2.7 Transients, Temperature, Voltage, and Humidity Tests TS 2 Section 2.2.8 Vibration 5-30 Hz, 0.5g, Resonant Frequency Search 1 hour endurance test Page 3 of 5

TO WHOM IT MAY CONCERN Page: 4 of 5 TS 2 Section 2.2.9 Shock (Impact) Test Half sine wave 11 ms, 10g Approvals Safety, EMC and Environmental Specific Approval Description EMC Europe EN 55022:2010 Information Technology Equipment- Radio disturbance characteristics Limits and Methods of measurement. Class A EN 50130-4:2011 Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder and social alarm systems. EN 61000-3-2:2006 + A2:2009 Mains harmonics Part 3-2: Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase) EN 61000-3-3:2008 Voltage fluctuations Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection. EN 50121-4:2006 Railway applications EMC USA CFR 47 FCC part 15 Class A Australian AS/NZS CISPR 22 equal to CISPR 22 Mains Voltage Tolerance Test (Brown out supply voltage test) Conducted + Radiated Emission based on VERIFICATION procedure Product market with BOSCH supplier code N663 Camera fully operational down to 105V (230 V PSU) and 55V (120V PSU). Below this voltage, the camera is not operational. Camera must be power- cycled for the camera block to reset. Lightning protection EN 61000-4-5:1995 Levels ±0.5, 1 and 2kV common mode. ± 0.5, 1 and 2kV differential mode. To ALL input / output - and supply-wiring. Safety Europe IEC 60950-1:2005 (2nd Edition) + A1:2009 EN 60950-1:2006, EN 60950-1, 2nd Edition, 2007-03-27 + A12:2011 Safety USA + Canada UL 60950-1 (2nd edition dated March 27, 2007; revised December 19, 2011) CAN/CSA-C22.2 No.E60950-1 (CSA C22.2 No. 60950-1-07, R2012) Information technology equipment Safety Part 1: General requirements UL listing + cul listing. Information technology equipment Safety Part 1: General requirements Page 4 of 5

TO WHOM IT MAY CONCERN Page: 5 of 5 Environmental Restriction of Hazardous Substances ROHS complaint Illuminator and Prohibited and declarable substances in Manufacturer s declaration database based Illuminator and on N 2580-1 products, components, materials and preparations. IEC 60950-22 Part 1: General requirements Report - US-23589-UL UL 60950-22 EN 60950-22 UL 50E Report - E183863-A34- CB-1 Functional and specification test Functional tests description Camera Performance Illuminator Performance Refer to MIC IP starlight 7000 HD datasheet. Refer to MIC7000 Illuminator datasheet. Miscellaneous specifications Description Pan and tilt drive output torque Pan = 8.5 N m (6.72 ft lb) Tilt = 15.84 N m (11.62 ft lb) The product is produced by a manufacturing organization which is certified on ISO9001 and ISO14001 standards. Page 5 of 5