Revo PC. USER S MANUAL Rev. 05/2011

Similar documents
Multi-Channel SCR Power Controller Suitable to control Electric Heaters and IR Lamps in Industrial Heating Systems

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

ACCESS 9340/9360 Meter Input/Output Module

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

Model Number Structure

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

Subject Ref. No. Page Alfa-V Dry Coolers IM00003_0808_AM 1/12. Issued by Department Date Menegolo Andrea Product Development

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

Innovation in Power Control

MDM 011-Z1 Regen Resistor

Model Number Structure

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

CUS150M1 Instruction Manual

ATV650U30N4E variable speed drive ATV650-3kW V - IP55 - disconnect switch

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

ATV32H075M2 variable speed drive ATV32-0,75 kw V - 1 phase - with heat sink

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Table of Contents. Safety. Attention. Warnings

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp)

ATV32HU40N4 variable speed drive ATV32-4 kw V - 3 phase - with heat sink

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21

Adaptable power control

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

ATV320U30N4B variable speed drive ATV320-3kW V - 3 phase - book

Innovation in Power Control

F1000 User's Manual. (Version: V1.01)

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

ATV32H055N4 variable speed drive ATV kw V - 3 phase - with heat sink

7032 Digital-Analog Multimeter

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

USER MANUAL. Frequency Converter 15kVA 3x200V 400Hz Type AC/AC Frequency Converter

Conductive Level Controller

Temperature/Process Controllers Manual

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D11N4B variable speed drive ATV320-11kW V - 3 phase - book

ATV212WU40N4 variable speed drive ATV212-4kW - 5hp - 480V - 3ph - EMC class C2 - IP55

ATV320U06N4C variable speed drive ATV kW V - 3 phase - compact

Voltage Current Front-mounting bracket

SOLARIMMERSION IV Advanced Installation Manual v1.9

ELV12 Series. Instruction Manual

ATV32H018M2 variable speed drive ATV32-0,18 kw V - 1 phase - with heat sink

ATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

ATV71EXA2C71N4 enclosed variable speed drive ATV71 Plus kw - 400V - IP23

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

em4 Accessories Digital expansions

TM221CE40R controller M IO relay Ethernet

EX-RC1 Remote I/O Adapter

ATV212HD18N4 variable speed drive ATV kW - 25hp - 480V - 3ph - EMC - IP21

MINI-PS AC/10-15DC/8

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

Solid-State Switching Devices

Power Electronics. Semiconductor relay / - contactor

Model Number Structure

JUMO TYA 201 Single-Phase SCR Power Controller For controlling resistive/inductive loads

ATV212WU55N4 variable speed drive ATV kW - 7.5hp - 480V - 3ph - EMC class C2 - IP55

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

Redundancy unit CP-A RU

Model 7705 Control Module

TM221CE24R controller M IO relay Ethernet

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

RTU500 series Data Sheet Power Supply CP-E 24/2.5

TU531, TU532 Terminal Unit

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

ATV212HD11N4 variable speed drive ATV212-11kW - 15hp - 480V - 3ph - EMC - IP21

Transcription:

USER S MANUAL Rev. 05/2011 Revo PC 00003 CD Automation S.r.l. Via Picasso 34/36-20025 Legnano (MI) ITALY Tel +39 0331 577479 Fax +39 0331 579479 E-Mail: info@cdautomation.com - WEB: www.cdautomation.com

1 Important warning for safety...3 2 Introduction...4 3 Identification and Order Code...6 3.1 Identification of the unit 6 3.2 Order Code 7 4 Technical Specifications...8 4.1 General features: 8 4.2 Input features: 8 4.3 Output features(power device): 8 4.4 Environmental installation conditions 8 5 Dimensions and Weight...9 5.1 Fixing holes 9 6 Wiring instructions...10 6.1 Supply 11 6.2 Serial Communication 11 6.2.1 RS485 modbus RTU slave...11 6.3 Digital Input 11 6.3.1 Terminal block M1 for Analog dinput or SSR input with HB...11 6.4 Current Transformer Input 12 6.4.1 Terminal block M5-M6-M7...12 6.5 Digital Output 12 6.5.1 Terminal block M2-M3-M4...12 6.6 Connection Diagram 14 7 Heater Break alarm and SCR short circuit (HB Option only)...16 8 Firing type...17 8.1 Burst Firing (BF) with Analog Input 17 9 Address Parameter...18 10 Maintenance...20 10.1 Warranty condition 20 2

1 Important warning for safety The Thyristor unit are integral part of industrial equipments. When it is supply, the Thyristor unit is subject to dangerous tensions. Don't remove the plastic cover. Don't use this unit in aerospace and nuclear application. Electric Shock Hazard (Rischi di scosse elettriche, Risque de choque électrique) When thyristor unit has been connected to main supply voltage and is switched off, before to touch it be secure that the unit is isolated and wait at least one minute to allow discharging internal capacitors. Thus be secure that: access to thyristor unit is only permitted to specialised personnel; the authorised personnel must read this manual before to have access to the unit; the access to the unit must be denied to unauthorised personnel. Important warnings (Avvertenze importanti, attention) During the operations with units under tension, local regulations regarding electrical installation should be rigidly observed: Respect the internal safety rules. Don't bend components to maintain insulation distances. Protect the units from high temperature humidity and vibrations. Don't touch components to prevent electrostatic discharges on them. Verify that the size is in line with real needs. To measure voltage current etc. on unit, remove rings and other jewels from fingers and hands. Authorized personnel that work on thyristor unit under power supply voltage must be on insulated board This listing does not represent a complete enumeration of all necessary safety cautions Protection (Protezione, Protection) The unit have IP20 protection rating as defined by the specific international. Is necessary consider the place of installation. Earth (Messa a terra, Terre) For safety, the Thyristor unit with isolated heat-sink must be connected to earth. Earth impedance should be correspondent to local earth regulation. Periodically the earth efficiency should be inspected. Electromagnetic compatibility (Compatibilità elettromagnetica, Compatibilité électromag.) Our thyristor units have an excellent immunity to electromagnetic interferences if all suggestions contained in this manual are respected. In respect to a good Engineering practice, all inductive loads like solenoids contactor coils should have a filter in parallel Emissions (Emissioni, Emission) All solid-state power controllers emit a certain amount of radio-frequency energy because of the fast switching of the power devices. The CD Automation s Thyristor unit are in accord with the EMC norms, CE mark. In most installations, near by electronic systems will experience no difficulty with interference. If very sensitive electronic measuring equipment or low-frequency radio receivers are to be used near the unit, some special precautions may be required. These may include the installation of a line supply filter and the use of screened (shielded) output cable to the load. 3

2 Introduction REVO PC was designed specifically to manage multizone systems. This powerful unit, with its unique algorithm, will minimize your energy costs by controlling sychronization and power limit of each zone. Benefits include: Elimination of power overshoot (see graph below). Power factor close to one due to zero crossing firing. REVO-PC keeps your instantaneous power within the limit of your electricity supply contract. Prevents increases in energy supply tariffs imposed by your electricity supplier. Quick return on your investment. This powerful unit with high performance micro can drive simple thyristor unit Revo S with zero crossing firing. By using the REVO PC, simple thyristor units can be used reducing the overall financial investment. Simultaneous fast full wave control of 8-16-24 REVO S - 1PH 8-16-24 REVO S - 2PH/3PH for 3 phase loads 8-16-24 REVO S - 2PH/3PH for 3 phase load with current calculation for each phase. Each loop's process information is managed independently. Calculation of instant current and RMS Voltage, Current and Power. Calculation of load resistance with Heater Break Alarm. Modbus Master, Modbus slave, Profilbus DP, Modbus/TCP, Can-Open 4

Easy to start REVO-PC Set the operative current of the heater zone. Set the Total Power Limit. Set the Power of each zone The REVO-PC strategy is easy to implement. Do the same operation with a competitor s load management system and the operator must learn up to 15 pages of the manual and understand up to five models of synchronization. Synchronization On all controlled zones, the Live Predictive Synchronization is automatic resulting in superior performance: Total current is equal to a sinusoidal wave form. Power factor > 0,9. Instantaneous current close to average value. Cancellation of harmonics. Power saving by harmonic reduction. Flickering effect removed. Synchronization selection is available for normal resistive loads or short infrared. Smart Power limitation Smart power limitation works together with synchronization. If this function is enabled, REVO-PC makes a live calculation of power at each period and generates the output values for the next period. If the calculated power is below the power limit value, the previous values remain with each channel using full power. If the power is above the power limit value, the setpoint of each channel is reduced proportionally to restrict power overshoot. This function significantly reduces disturbances on the main network compared to a full power system, preventing any increase in energy tariffs imposed by the electricity supplier. This function can be activated/deactivated and the limit value changed at any time. 5

3 Identification and Order Code 3.1 Identification of the unit Caution: Before to install, make sure that the Thyristor unit have not damages. If the product has a fault, please contact the dealer from which you purchased the product. The identification's label give all the information regarding the factory settings of the unit, this label is on the unit, like represented in figure. Verify that the product is the same thing as ordered. 6

3.2 Order Code 7

4 Technical Specifications 4.1 General features: Cover and Socket material: PolymericV2 IP Code 20 Auxiliary voltage: 4.2 Input features: Current Transormer Input Configurable Digital Input calib. 12 21V ac (max 70mA)If requested max 50mA 12 24V dc/ac (max 4mA) 4.3 Output features(power device): 4.4 Environmental installation conditions Ambient temperature 0-40 C at nominal current. Over 40 C use the derating curve. Storage temperature -25 C a 70 C Installation place Altitude Humidity Don t install at direct sun light, where there are conductive dust, corrosive gas, vibration or water and also in salty environmental. Up to 1000 meter over sea level. For higher altitude reduce the nominal current of 2% for each 100m over 1000m From 5 to 95% without condense and ice Pollution Level Up to 2nd Level ref. IEC 60947-1 6.1.3.2 8

5 Dimensions and Weight REVO S 1PH Size W(mm) D(mm) H(mm) Weight (kg) 1PH (60-90A no Fan) 93 170 269 3,4 1PH (120-210A with Fan) 93 170 273 3,6 5.1 Fixing holes REVO S 1PH 1PH (60-90A no Fan) H1 256 9

6 Wiring instructions The Thyristor unit could be susceptible to interferences lost by near equipments or by the power supply, for this reason in accord to the fundamental practices rules is opportune take some precautions: The coil contactor, the relays and other inductive loads must be equipped with opportune RC filter. Use shielded bipolar cables for all the input and output signals. The signal cables must not be near and parallel to the power cables. Local regulations regarding electrical installation should be rigidly observed. Use copper cables and wires rated for use at 75 C only. 10

6.1 Supply Warning: Before connecting or disconnecting the unit check that power and control cables are isolated from voltage sources. Terminal M8 Description 1 Aux Voltage Supply for elettronic boards 21 V ac 2 n.c. 3 Aux Voltage Supply for elettronic boards 21 V ac 6.2 Serial Communication 6.2.1 RS485 modbus RTU SLAVE Terminal M9 1 RS485 B- 2 RS485 A+ Description 6.2.2 modbus RTU MASTER Terminal M10 1 RS485 B- 2 RS485 A+ Description 6.3 Digital Input 6.3.1 Terminal block M1 for Analog dinput or SSR input with HB Terminal Description M1 1 GND 2 GND 3 +12 Vdc 4 - Common Digital Input 5 + Digital Input 4 6 + Digital Input 3 7 + Digital Input 2 8 + Digital Input 1 11

6.4 Current Transformer Input 6.4.1 Terminal block M5-M6-M7 Terminal M5-M6-M7 1 CTI 1 - Current Transformer Input 2 CTI 2 - Current Transformer Input 3 +12 Vdc 4 GND 5-12 Vdc Description 6.5 Digital Output 6.5.1 Terminal block M2-M3-M4 Terminal Description M4 1 GND 2 +12 Vdc 3 + Common Digital Output 4 - Digital Output 1 5 - Digital Output 2 6 - Digital Output 3 7 - Digital Output 4 8 - Digital Output 5 9 - Digital Output 6 10 - Digital Output 7 11 - Digital Output 8 12 N.C. Terminal Description M3 1 GND 2 +12 Vdc 3 + Common Digital Output 4 - Digital Output 9 5 - Digital Output 10 6 - Digital Output 11 7 - Digital Output 12 8 - Digital Output 13 9 - Digital Output 14 10 - Digital Output 15 11 - Digital Output 16 12 N.C. 12

Terminal M2 Description 1 GND 2 +12 Vdc 3 + Common Digital Output 4 - Digital Output 17 5 - Digital Output 18 6 - Digital Output 19 7 - Digital Output 20 8 - Digital Output 21 9 - Digital Output 22 10 - Digital Output 23 11 - Digital Output 24 12 N.C. 13

Caution: this procedure must be performed only by qualified persons. 6.6 Connection Diagram NOTE: * The user installation must be protecting by electromagnetic circuit breaker or by fuse isolator. The semiconductor I2t should be 20% less than power controller I2t. Semiconductor fuses are classified for UL as supplemetar protection for semiconductor. They are note approved for branch circuit protection. *² The auxiliary voltage supply must be synchronized with load voltage power supply. If the Auxiliary Voltage (written on the identification label) is different from Supply Voltage (to the load), use an external transformer as designated. 14

15

7 Heater Break alarm and SCR short circuit (HB Option only) Caution: to work properly the load must be powered at least about 160msec. The Heater Break circuit read the load current with an Internal current transformer (C.T.). Minimum current is 10% of the current transformer size. If load current is below this value the Heater Break Alarm doesn t work properly. Heater break Calibration procedure An automatic function sets the Heater Break Alarm. The auto setting function can be activated using the CAL button on front unit, or supply with 12-24Vdc the digital input "Cal Ext." (See Connection Diagram). The Heater Break calibration procedure is performed in this way: The Unit gives the maximum voltage output all LEDS are on, this means that calibration procedure is active The current value is stored in memory After about 15 second the unit comes back to the initial situation If load current decreases for partial or total load failure (sensitivity 20%) the yellow LED HB become ON and alarm relay change status. If the unit is still in conduction with no input signal (LED green OFF) it means that there is a short circuit on thyristors and red LED (SC) become ON. If the load has been changed the Heater Break calibration procedure must be done again 16

8 Firing type Choose a correct firing type allows to optimize the thyristor unit for the installed load. The firing type has already configured in line with customer requirements,zero Crossing for SSR input and Burst firing for Analog Input. Caution: this procedure must be performed only by qualified persons. 8.1 Burst Firing (BF) with Analog Input The Burst Firing is similar to the Single Cycle, but consecutive cycles ON are selectable between 2 and 255, with input signal equal at 50%. Burst Firing is a method zero crossing that it reduces the electromagnetic interferences because the thyristor switches at zero voltage crossing. The example show the Burst Firing with Burst cycles: 4 ON OFF VOLTAGE SUPPLY (V) LOAD VOLTAGE (V) 25% 50% 75% 100% 17

9 Address Parameter 100 ADDR_OUT1_VAL % Out (in tenths) canal 1 (SP) 101 ADDR_OUT2_VAL 102 ADDR_OUT3_VAL 103 ADDR_OUT4_VAL 104 ADDR_OUT5_VAL 105 ADDR_OUT6_VAL 106 ADDR_OUT7_VAL 107 ADDR_OUT8_VAL 108 ADDR_OUT9_VAL 109 ADDR_OUT10_VAL 110 ADDR_OUT11_VAL 111 ADDR_OUT12_VAL 112 ADDR_OUT13_VAL 113 ADDR_OUT14_VAL 114 ADDR_OUT15_VAL 115 ADDR_OUT16_VAL 116 ADDR_OUT17_VAL 117 ADDR_OUT18_VAL 118 ADDR_OUT19_VAL 119 ADDR_OUT20_VAL 120 ADDR_OUT21_VAL 121 ADDR_OUT22_VAL 122 ADDR_OUT23_VAL 123 ADDR_OUT24_VAL % Out (in tenths) canal 24 (SP) 124 ADDR_OUT1_PWR Power Rating (in 0.1 KW) canal 1 125 ADDR_OUT2_PWR 126 ADDR_OUT3_PWR 127 ADDR_OUT4_PWR 128 ADDR_OUT5_PWR 129 ADDR_OUT6_PWR 130 ADDR_OUT7_PWR 131 ADDR_OUT8_PWR 132 ADDR_OUT9_PWR 133 ADDR_OUT10_PWR 134 ADDR_OUT11_PWR 135 ADDR_OUT12_PWR 136 ADDR_OUT13_PWR 137 ADDR_OUT14_PWR 138 ADDR_OUT15_PWR 139 ADDR_OUT16_PWR 140 ADDR_OUT17_PWR 141 ADDR_OUT18_PWR 142 ADDR_OUT19_PWR 143 ADDR_OUT20_PWR 144 ADDR_OUT21_PWR 145 ADDR_OUT22_PWR 146 ADDR_OUT23_PWR 147 ADDR_OUT24_PWR Power Rating (in 0.1 KW) canal 24 247 ADDR_PLIMIT Limit Value PWR 252 ADDR_STSALL_GRP1 Presence of group 1 alarms (bit 0 = alarm L canal 1 bit 7 = alarm L canal 8 bit 8 = alarm H canal 1 bit 15 = alarm H canal 8) 253 ADDR_STSALL_GRP2 Presence of group 2 alarms (bit 0 = alarm L canal 9 bit 7 = alarm L canal 16 bit 8 = alarm H canal 9 bit 15 = alarm H canal 16) 18

254 ADDR_STSALL_GRP3 Presence of group 3 alarms (bit 0 = alarm L canal 17 bit 7 = alarm L canal 24 bit 8 = alarm H canal17 bit 15 = alarm H canal 24) 255 ADDR_STSINPUT Digital Input Satus (bit 0 = status I1 bit 3 = status I4) 300 ADDR_STS_LOCREM3 Local Remote Status 301 ADDR_SYNC_MODE Synchronism Type (Half Double) 302 ADDR_OUT1_DEV Modbus Address master device 1 526 ADDR_I_CHN1 Canale 1 Current 527 ADDR_I_CHN2 528 ADDR_I_CHN3 529 ADDR_I_CHN4 530 ADDR_I_CHN5 531 ADDR_I_CHN6 532 ADDR_I_CHN7 533 ADDR_I_CHN8 534 ADDR_I_CHN9 535 ADDR_I_CHN10 536 ADDR_I_CHN11 537 ADDR_I_CHN12 538 ADDR_I_CHN13 539 ADDR_I_CHN14 540 ADDR_I_CHN15 541 ADDR_I_CHN16 542 ADDR_I_CHN17 543 ADDR_I_CHN18 544 ADDR_I_CHN19 545 ADDR_I_CHN20 546 ADDR_I_CHN21 547 ADDR_I_CHN22 548 ADDR_I_CHN23 549 ADDR_I_CHN24 Canale 24 Current 550 ADDR_P_CHN1 Canal 1 Power 551 ADDR_P_CHN2 552 ADDR_P_CHN3 553 ADDR_P_CHN4 554 ADDR_P_CHN5 555 ADDR_P_CHN6 556 ADDR_P_CHN7 557 ADDR_P_CHN8 558 ADDR_P_CHN9 559 ADDR_P_CHN10 560 ADDR_P_CHN11 561 ADDR_P_CHN12 562 ADDR_P_CHN13 563 ADDR_P_CHN14 564 ADDR_P_CHN15 565 ADDR_P_CHN16 566 ADDR_P_CHN17 567 ADDR_P_CHN18 568 ADDR_P_CHN19 569 ADDR_P_CHN20 570 ADDR_P_CHN21 571 ADDR_P_CHN22 572 ADDR_P_CHN23 573 ADDR_P_CHN24 Canal 24 Power 19

10 Maintenance In order to have a corrected cooling, the user must clean the heat-sink and the protective grill of the fans. The frequency of this servicing depends on environmental pollution. Also check periodically if the screw for the power cables and safety earth are tightened correctly (See Connection Diagram) 10.1 Warranty condition CD Automation gives a 12 months warranty to its products. The warranty is limited to repairing and parts substitution in our factory and does exclude products not properly used and fuses. Warranty does not include products with serial numbers deleted. The faulty product should be shipped to CD Automation at customer s cost and our Service will evaluate if product is under warranty terms. Substituted parts remain of CD Automation property. 20

21