General and Copyright Notice Warranty OmniConverter Limitation of Warranty Environmental Notices User Manual

Similar documents
OmniConverter GPoE+/M Managed 4 and 8-Port PoE/PoE+ Switch. Quick Start Guide

iconverter 2-Module Power Chassis

OmniConverterTM. OmniConverter GPoE+/Sx KEY FEATURES. Unmanaged 10/100/1000 Power Source Equipment (PSE) PoE/PoE+ Ethernet Fiber Switch

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

RuggedNet. RuggedNet GPoE+/Mi KEY FEATURES. Managed Industrial 10/100/1000 Power Source Equipment (PSE) PoE/PoE+ Ethernet Fiber Switch

OmniConverterTM. OmniConverter FPoE/SL, FPoE/S and FPoE+/S 10/100 Media Converter with Power over Ethernet (PoE or PoE+) KEY FEATURES

iconverter 1-Module Redundant Chassis

OmniConverterTM. OmniConverter GPoE/S, GPoE+/S and GHPoE/S 10/100/1000 Media Converter with Power over Ethernet (PoE, PoE+ or 60W PoE) KEY FEATURES

OmniConverterTM. OmniConverter GPoE/S, GPoE+/S and GHPoE/S 10/100/1000 Media Converter with Power over Ethernet (PoE, PoE+ or 60W PoE) KEY FEATURES

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Perle PoE/PoE+ 10/100/1000 Ethernet Media Converters

100Base-FX to 10/100Base-TX. PoE. Media Converter. FCU-1802Px. User s Manual

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

Perle PoE/PoE+ 10/100 Ethernet Media Converters

M727xSP. PoE Powered. Ethernet Media Converter 10/100BASE-TX TO 100BASE-SX/LX. Installation Guide

MF BASE-T to 1000BASE-X INDUSTRIAL MEDIA CONVERTER WITH SFP SUPPORT INSTALLATION GUIDE

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

MC100FX-TX-PoE Media Converter User Manual

PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide

PoE Giga-McBasic PoE+ Giga-McBasic with LFPT. Operation Manual

Quick Start Guide. Physical Description. The Port Status LEDs

5-Port 10/100Mbps with 4-Port PoE. Industrial Fast Ethernet Switch ISW-504PT / ISW-514PT / ISW-514PT15 / ISW-514PTF. User's Manual

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

MIL-S24002TGxx. 24-port 10/100/1000 TX 2 Combo SFP Slots Unmanaged Switch. User Guide

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS,

Optical DVI Dual Link Extension Module

IFS MC201-1P/1FS User Manual

PTC-101 Quick Installation Guide

Perle Gigabit Media Converter Module. Installation Guide P/N

A Line of Fixed-Port Industrial Ethernet 10/100 Mbps Switches INSTALLATION GUIDE

KFC-200. Installation Guide

Owner s Manual. Media Converters

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

Owner s Manual. Media Converters Models: N SC & N ST

800xA Networks. NE801 User Manual. Power and productivity for a better worldtm

Industrial 3-Port Fast Ethernet Media Converter Switches

SG Port 10/100/1000Base Switch with (8) 1000Base SFP Slots

PTC-101-M12 Hardware Installation Guide

M727xS 10/100BaseTX-FX Selectable Media Converter Installation Guide

EDS-G205A-4PoE Hardware Installation Guide

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

Hardened PoE Ethernet Switch

Features and Benefits. Certifications

DynaGST/2402G. 24 Port 10/100/1000Base-T Gigabit Ethernet Switch with two SFP (mini) GBIC Slots PN: GEP-33224T USER S MANUAL

Fast / Gigabit Ethernet Switch Module. MII series. User's Manual

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS. KC-300DM Series. Installation Guide

Optical DVI Module. User s Manual M1-2R2-TR. Doc No. : OEB-D R2 / Rev2.6

Perle Gigabit Media Converters

IMC-21GA Quick Installation Guide

exp-s1110pe PoE+ Gigabit Ethernet Extenders

Instruction Manual Series 46 PoE Ethernet Fiber Optic Transceivers

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001. Installation Guide

OmniRepeater TM 400FTD. Systems AS400/3X Fiber to Desk Repeater. User s Manual SPECIFICATIONS TECHNICAL SUPPORT

Features and Benefits. Certifications

SP-PoE Splitter User Manual

DynaGST/2402G USER S MANUAL

Optical DVI Daisy-chain Extender

87421/22A Power Supply. Operating and Service Manual

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

Copyright PLANET Technology Corp Contents subject to revision without prior notice.

Owner s Manual. Gigabit Fiber to Ethernet Media Converters with PoE

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual

Gigabit Ethernet Industrial Switch 10 Port with Ring- Redundancy and PoE

Industrial PoE Media Converter

Industrial Single-Port 10/100/1000Mbps bt PoE Injector. IPOE-171 Series User s Manual

8-Port 10/100TX 802.3at PoE + 1-Port 10/100/1000T + 1-Port 100/1000X SFP Desktop Switch FGSD-1011HP. User s Manual

OPERATOR MANUAL OSD2153 SERIES GIGABIT ETHERNET MEDIA CONVERTER

8-Port 10/100TX 802.3at PoE + 2-Port 10/100TX Desktop Switch FSD-1008HP. User s Manual

gigabit industrial ethernet user manual Models , ,

IMC-21A Quick Installation Guide

5 Port Industrial Ethernet Switch. IES5100 Instruction Manual

MEDIA CONVERTERS AND CHASSIS

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

TRENDnet User s Guide. Cover Page

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

Gigabit Ethernet Micro Switch 6 Port PoE

OPERATOR MANUAL. OSD2053P SERIES MICRO 10/100Base-T to 100Base-X MEDIA CONVERTER. WITH PoE SOURCE

LNX-0702G-SFP Series

USER S MANUAL. 5 and 8 Port 10/100/1000Base-T Gigabit Ethernet Switches

Quick Start Guide Elinx ESW200 Series. 5 and 8 port Unmanaged Ethernet Switch

Volition. Fast Ethernet Fiber Optic Media Converters. Installation Manual VOL-0205/VOL-0206 /VOL-0207/VOL December

Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide

Instruction Manual MX2-MM-LX-SC MXR2-MM-LX-SC MX2-SM-LX-SC MXR2-SM-LX-SC Media Converter

C Mb Ethernet Copper Tap

USB303HE. USB 3.0 HUB with Gigabit Ethernet Adapter. User s Manual

USB Ranger Fiber Optic USB 2.0 Extender. User Guide

User s Manual. 2-Fiber Detachable Dual Link DVI module, DDFX-100. Manual Contents.

LNX-1002C-SFP Series

User s Manual. 2-Fiber Detachable Dual Link DVI module, DDFX-100. Manual Contents.

Quick Start Guide Elinx ESW100 Series. 5 and 8 port Unmanaged Ethernet Switch

ex-s1110-xt Gigabit Ethernet Extenders

EIDX_M Series INSTALLATION GUIDE INTRODUCTION. A Line of Managed Ethernet Switching Hubs

FCC Warning. CE Mark Warning. VCCI Mark Warning

Gigabit Ethernet Industrial Switch 10 Port with Railway and Power Substation Certification

Transcription:

OmniConverter GPoE+/Sx Unmanaged 8-Port PoE/PoE+ Switch User Manual General and Copyright Notice This publication is protected by U.S. and international copyright laws. All rights reserved. The whole or any part of this publication may not be reproduced, stored in a retrieval system, translated, transcribed, or transmitted, in any form, or by any means, manual, electric, electronic, electromagnetic, mechanical, chemical, optical or otherwise, without prior explicit written permission of Omnitron Systems Technology, Inc. The following trademarks are owned by Omnitron Systems Technology, Inc.: FlexPoint TM, FlexSwitch TM, HybridNID, iconverter, miconverter TM, NetOutlook, OmniLight, OmniConverter TM, RuggedNet TM, Omnitron Systems Technology, Inc. TM, OST TM and the Omnitron logo. All other company or product names may be trademarks of their respective owners. The information contained in this publication is subject to change without notice. Omnitron Systems Technology, Inc. is not responsible for any inadvertent errors. Warranty This product is warranted to the original purchaser (Buyer) against defects in material and workmanship for a period of two (2) years from the date of shipment. A five (5) warranty may be obtained by the original purchaser by registering this product at www.omnitron-systems.com/support within ninety (90) days from the date of shipment. During the warranty period, Omnitron will, at its option, repair or replace a product which is proven to be defective with the same product or with a product with at least the same functionality. For warranty service, the product must be sent to an Omnitron designated facility, at Buyer s expense. Omnitron will pay the shipping charge to return the product to Buyer s designated US address using Omnitron s standard shipping method. Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate use and/ or maintenance of the equipment by Buyer, Buyer-supplied equipment, Buyer-supplied interfacing, unauthorized modifications or tampering with equipment (including removal of equipment cover by personnel not specifically authorized and certified by Omnitron), or misuse, or operating outside the environmental specification of the product (including but not limited to voltage, ambient temperature, radiation, unusual dust, etc.), or improper site preparation or maintenance. No other warranty is expressed or implied. Omnitron specifically disclaims the implied warranties of merchantability and fitness for any particular purpose. The remedies provided herein are the Buyer s sole and exclusive remedies. Omnitron shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any legal theory. Environmental Notices The equipment covered by this manual must be disposed of or recycled in accordance with the Waste Electrical and Electronic Equipment Directive (WEEE Directive) of the European Community directive 2012/19/EU on waste electrical and electronic equipment (WEEE) which, together with the RoHS Directive 2011/65/EU, for electrical and electronic equipment sold in the EU after July 1, 2006. Such disposal must follow national legislation for IT and Telecommunication equipment in accordance with the WEEE directive: (a) Do not dispose waste equipment with unsorted municipal and household waste. (b) Collect equipment waste separately. (c) Return equipment using collection method agreed with Omnitron. The equipment is marked with the WEEE symbol shown to indicate that it must be collected separately from other types of waste. In case of small items the symbol may be printed only on the packaging or in the user manual. If you have questions regarding the correct disposal of equipment go to www.omniton-systems.com/support or e-mail to Omnitron at intlinfo@omnitron-systems.com. 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 2

OmniConverter GPoE+/Sx User Manual Product Overview The OmniConverter GPoE+/Sx is an unmanaged Ethernet switch that features one or two 1000BASE-X Gigabit fiber ports and eight 10/100/1000BASE-T RJ-45 Power Sourcing Power-over-Ethernet (PoE and PoE+) ports. OmniConverter GPoE+/Sx provides network distance extension with fiber cabling, and function as PoE injectors providing power to eight Powered Device (PDs) over standard UTP cables that carry Ethernet data. OmniConveter GPoE+/Sx 8-Port The GPoE+/Sx is a Power Sourcing Equipment (PSE) that provides up to 30W PoE+ (IEEE 802.3at) per RJ-45 port and supports frame sizes up to 10,240 bytes. The GPoE+/Sx automatically negotiates and delivers the power level required by its Powered Device (PD) partner. When negotiating to PoE (IEEE 802.3af) it delivers up to 15.4 Watts per RJ-45 port. When negotiating to PoE+ (IEEE 802.3at) it delivers up to 30 Watts per RJ-45 port. Front Panel The front of the GPoE+/Sx provides access to the RJ-45 PoE, SFP and Fixed-Fiber ports. The SFP ports support 1000BASE-X SFP fiber and 10/100/1000BASE-T copper transceivers. RJ-45 PoE, SFP and Fixed-Fiber Ports The RJ-45 PoE Ethernet port supports 10BASE-T, 100BASE-TX and 1000BASE-T protocols, auto-negotiation, auto MDI/MDI-X crossover and can be manually forced to a specific speed and duplex mode. The SFP interfaces support SERDES 1000BASE-X fiber transceivers and SGMII 10/100/1000BASE-T copper transceivers. The SFP interfaces operate in autonegotiation and support full duplex operation. Fixed-fiber 1000BASE-X connectors are available with multimode (MM) dual fiber, single-mode (SM) dual fiber and single-mode single-fiber (SF) options. They support ST, SC and LC connectors. Installation Procedure 1) Configure DIP-switches 2) Apply AC Power 3) Connect Cables 4) Verify Operation 1) Configure DIP-switches Front Panel Layout DIP-switches are located on the side of the OmniConverter GPoE+/Sx. The DIP-switches are used to configure modes of operation, networking features and PoE reset. DIP-switch Bank Locations The table below provides a description of each DIP-switch position and function. Switch 1 Fiber Port 2 Fiber Ports 1 Mode Of Operation 2 3 Reserved 4 Reserved 5 MAC Learning 6 Pause 7 L2CP 8 PoE Reset Fiber Redundancy DIP-switch Definitions Page 3 Page 4

SW1 and SW2: Mode of Operation The GPoE+/Sx supports Switch, Directed Switch and Dual Device mode. The modes are described with MAC learning enabled. When MAC learning is disabled, unicast packets are forwarded to all ports. SW1 SW2 Function DOWN DOWN Switch Mode (factory default) DOWN UP Directed Switch Mode UP DOWN Dual Device Mode - Switch Mode UP UP Dual Device Mode - Directed Switch Mode Switch Mode Modes of Operation When configured for Switch Mode (factory default), the module operates as a standard layer 2 switch. Data flow will follow MAC address mapping. Directed Switch Mode When configured for Directed Switch Mode, traffic from Ports P1 - P8 is only forwarded to the fiber uplink port F1, preventing the broadcast traffic from flooding to other network ports. Incoming traffic from F1 follows MAC address mapping. Models with two fiber ports follow the same RJ-45 data flow as above, with the addition of fiber port F2 also being forwarded to the fiber uplink port F1. Two fiber ports models can be configured for Directed Switch Mode and Fiber Redundancy (per DIP-switches 3 and 4), traffic is forwarded to both the primary and secondary fiber ports. The secondary port will block all traffic while the primary port is active. When the primary port goes down, the secondary port will be active and all traffic will be forwarded out the secondary port (F2). Dual Device Mode Directed Switch Mode with Fiber Redundancy Dual Device Mode is only supported on GPoE+/Sx with two fiber ports. When configured for Dual Device Mode, the GPoE+/Sx is configured as two logically independent Layer 2 switches. Fiber port F1 is associated with RJ-45 Ports P1 - P4 and fiber port F2 is associated with RJ-45 Ports P5 - P8. Data flow will follow MAC address mapping. Directed Switch Mode Dual Device Mode Page 5 Page 6

When configured for Dual Device Mode and Directed Switch Mode, the traffic from Ports 1-4 is only forwarded to fiber port F1 and Ports 5-8 are only forwarded to fiber port F2. This prevents broadcast traffic from flooding other network ports. Incoming traffic from F1 and F2 follows MAC address mapping. Fiber redundancy is only supported on GPoE+/Sx models with two fiber ports. When configured for Redundant Mode no return to primary, the fiber ports operate as redundant links. A fault on the primary fiber port F1, will cause a fail over to the secondary fiber port F2 within 50msec. F1 will become the secondary port once the port has been restored because no return to primary has been selected. Dual Device with Directed Switch Mode SW3 and SW4: Fiber Redundancy SW3 and SW4 are valid on models with two fiber ports. The modes are described with MAC learning enabled. When MAC learning is disabled, the GPoE+/Sx will send data to all ports. SW3 SW4 Function DOWN DOWN Switch Mode (factory default) DOWN UP Switch Mode (factory default) UP DOWN Redundant Mode - no return to primary (F1) UP UP Redundant Mode - return to primary (F1) Fiber Redundancy Redundant Fiber When configured for Redundant Mode return to primary, a fault on the primary fiber port F1, will cause a fail over to the secondary fiber port F2 within 50msec. The module will return to the primary fiber port F1 after the fiber link has been restored for 6 seconds. SW5: MAC Learning - MAC Learning/Off When this DIP-switch is in the MAC Learning position (factory default), all ports on the module will learn the source MAC address of each received packet and store the address so packets destined for the stored addresses can be forwarded to the appropriate port on the module. When the DIP-switch is in the Off position, learning is turned off and all received unicast packets are forwarded to all ports. SW6: Pause - Pause Off/On Setting the DIP-switch to the Down Pause Off position (factory default) configures the module to advertise no Pause capability on all ports. Setting this DIP-switch to the Up On position configures the module to advertise Symmetrical and Asymmetrical Pause capability to all ports. SW7: L2CP - L2CP Tunnel/Discard When this DIP-switch is in the Down L2CP Tunnel position (factory default), all L2CP frames will be tunneled through the module. When this DIP-switch is in the Up Discard position, all L2CP frames will be discarded. SW8: PSE Reset - Off/PoE Reset The GPoE+/Sx can be configured to disable (reset) the PoE output power for 2 seconds after a loss of receive link on any fiber port. This feature is typically used to allow a PD to re-initialize after a failure on the incoming fiber. When this DIP-switch is in the Down Off position (factory default), PoE output power does not reset on fiber link loss. When this DIP-switch is in the Up PoE Page 7 Page 8

Reset position, the module will disable PoE output power for 2 seconds following a loss of receive link on any fiber port. When fiber redundancy is enabled, the loss of fiber link on either F1 or F2 will not cause the PD to be re-initialized even though the PSE Reset is enabled. The PD will be re-initialized on a loss of receive link on both fiber ports. When Dual Device Mode is enabled, the loss of fiber link will re-initialize the PDs associated with the that fiber port. RJ-45 ports 1-4 will drop PoE power when a loss of receive link on F1 is detected and RJ-45 ports 5-8 will drop PoE power when a loss of receive link on F2 is detected. 2) Apply AC Power To power the module using the AC/DC adapter, connect the AC/DC adapter to the AC outlet. Route the power cord through the provided strain relief for additional support. Then connect the DIN connector at the end of the wire on the AC/DC adapter to the DC power DIN connector on the module. Confirm that the module has powered up properly by checking the Power LED located on the front of the installed module. Installation of the equipment should be such that the air flow in the front, back, side and top vents of the module are not compromised or restricted. If the installation requires NEBS grounding, secure the grounding wire to the ground lug. See the figure below for the location of the grounding lug. 3) Connect Cables a. When using SFP models, insert the SFP fiber transceiver into the SFP receptacle on the front of the module (see the SFP Data Sheet 091-17000-001 for supported Gigabit transceivers). NOTE: The release latch of the SFP fiber transceiver must be in the closed (up) position before insertion. b. Connect an appropriate multimode or single-mode fiber cable to the fiber port on the front of the module. It is important to ensure that the transmit (TX) is attached to the receive side of the transceiver at the other end and the receive (RX) is attached to the transmit side. When using single-fiber (SF) models, the TX wavelength must match the RX wavelength at the other end and the RX wavelength must match the TX wavelength at the other end. c. Connect the Ethernet 10/100/1000 RJ-45 port using a Category 5 or better cable to an external 10BASE-T, 100BASE-TX or 1000BASE-T Ethernet device. RJ-45 Pinout Alternative B 1 Vport Positive 2 Vport Positive 3 Vport Negative 4 5 6 Vport Negative 7 8 Voltage Polarity of Alternative A PoE Power Rear View with AC Power Connector WARNING!!! NEVER ATTEMPT TO OPEN THE CHASSIS OR SERVICE THE POWER SUPPLY. OPENING THE CHASSIS MAY CAUSE SERIOUS INJURY OR DEATH. THERE ARE NO USER REPLACEABLE OR SERVICEABLE PARTS IN THIS UNIT. Page 9 Page 10

4) Verify Operation Verify the GPoE+/Sx is operational by viewing the LED indicators. Power LED Indicators Pwr Amber - ON Unit not powered Unit powered Over temperature condition Power LED Indicators Fiber Ports LED Indicators - SFP Models 100 1000 Green - Blinking at 1Hz Green - Blinking at 1Hz Port linked at 100Mbps Port data activity at 100Mbps Port linked at 100Mbps and in redundant standby mode Port linked at 100Mbps and receiving Far End Fault Indicator (FEFI) Port linked at 1000Mbps Port data activity at 1000Mbps Port linked at 1000Mbps and in redundant standby mode Port linked at 1000Mbps and receiving AN Remote Fault NOTE: 100M operation is only supported using copper SFP transceivers. Fiber LED Indicator - SFP Models Fiber Ports LED Indicators - Fixed Fiber Models RJ-45 Ports LED Indicators 100 1000 10 (100+1000) PoE/PSE Amber -ON Amber -ON Amber -ON Port linked at 100Mbps Port data activity at 100Mbps Port linked at 100Mbps Half-duplex Port data activity at 100Mbps Half-duplex Port linked at 1000Mbps Port data activity at 1000Mbps Port linked at 1000Mbps Half-duplex Port data activity at 1000Mbps Half-duplex Port linked at 10Mbps Port data activity at 10Mbps Port linked at 10Mbps Half-duplex Port data activity at 10Mbps Half-duplex Green - Blinking at 1Hz Port PSE is active and supplying 15.4W Amber - ON Port PSE is active and supplying 30W Port PSE error/inactive Port PSE inactive due to resistance too low (< 15k ohms) or short circuit detected Port PSE inactive due to resistance to high (33k to 500k ohms) Port PSE inactive RJ-45 LED Indicators 1000 Green - Blinking at 1Hz Port linked at 1000Mbps Port data activity at 1000Mbps Port linked at 1000Mbps and in redundant standby mode Port linked at 1000Mbps and receiving AN Remote Fault Fiber LED Indicators - Fixed Fiber Models Page 11 Page 12

Specifications Description Standard Compliances OmniConverter GPoE+/Sx 10/100/1000BASE-T to 1000BASE-X Fiber Unmanaged Ethernet Switch with PoE+ IEEE 802.3, IEEE 802.3af (15.40 watts max), IEEE 802.3at (30 watts max) PoE Supported Modes IEEE Alternate A (Alt A) Regulatory Compliances* Environmental Frame Size Port Types Cable Types AC Power Requirements Dimensions Weight Operating Temperature Humidity Altitude MTBF (hours) * Pending Warranty UL, CE, FCC Class A REACH, RoHS2 and WEEE Up to 10,240 bytes Copper: Fiber: Copper: Fiber: 10/100/1000BASE-T (RJ-45) 1000BASE-X (ST, SC, LC, SFP) EIA/TIA 568A/B, Cat 5 UTP and higher Multimode: 50/125, 62.5/125µm Single-mode: 9/125µm 100-240VAC/50-60Hz 2.4A @ 120VAC (typical) W: 6.28 x D: 5.2 x H: 1.5 L: 159.5 mm x B: 132.1 mm x H: 38.1 mm w/o Adapter: TBD lbs.; TBD grams w/ Adapter: TBD lbs.; TBD grams Commercial: 0 to 50 C (For -40 to +75 C, consult Omnitron) 5 to 95% (non-condensing) -100m to 4,000m (operational) AC Adapter: TBD 5 year product warranty with 24/7/365 free Technical Support 2 year AC power adapter warranty Customer Support Information If you encounter problems while installing this product, contact Omnitron Technical Support: Phone: (949) 250-6510 Fax: (949) 250-6514 Address: Omnitron Systems Technology, Inc. 38 Tesla Irvine, CA 92618, USA Email: support@omnitron-systems.com URL: www.omnitron-systems.com 040-09440-002A 10/17 Page 13 Page 14