AC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

Hygro-Thermometer / Datalogger

Moisture Content Meter Plus Dew Point, Wet Bulb, and Thermocouple Temperature functions

Vibration Meter SD Card real-time datalogger

4-Channel Thermometer / Datalogger

User Manual. Heavy Duty Differential Pressure Manometer. Model SDL720. Additional User Manual Translations available at

ph/orp Meter SD Card real-time Datalogger

4-Channel Vibration Datalogger

USER GUIDE Current Calibrator

AC/DC MAGNETIC METER OPERATION MANUAL. Model : PCE-MFM G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

Sound Level Meter SD Card real-time Datalogger

Model A Mini AC/DC Clamp Meter. User's Guide

USER GUIDE. Heavy Duty Digital Light Meter with PC Interface. Model HD400

Thermocouple Calibrator

USER GUIDE. 3 Channel DC Current Datalogger Model SD900

Digital Sound Level Meter

Vibration Meter and Laser Combination Tachometer

Datalogging Hygro-Thermometer

User's Guide. EasyView K-Type Thermometer. Model EA11A

User Guide. Conductivity Meter. Model EC210

Formaldehyde Thermo-Hygrometer

Model A Current / Voltage Calibrator. User's Guide

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

User Manual. Thermocouple Datalogging Thermometer. Model EA15

USER GUIDE. Heavy Duty Differential Pressure Manometer. Model HD700

User's Guide. Hot Wire Thermo-Anemometer. Model

User's Guide. Datalogging Hygro-Thermometer Model SD500

Datalogging Hygro-Thermometer

Model A Current Calibrator. User Guide

3 Channel Datalogging Thermometer

User Guide True RMS Multimeter Extech EX205T

Barometric Pressure / Humidity and Temperature Datalogger

AC/DC MAGNETIC METER

User's Guide. 3 Channel Datalogging Thermometer Model SD200

User Guide. Indoor Air Quality Meter/Datalogger. Model EA80

User's Guide. Digital Multimeter. Model MN42

User's Guide. Barometric Pressure / Humidity and Temperature Datalogger Model SD700

USER GUIDE. Dual Input True RMS AC Voltage/Current Datalogger. Model DL160

Large Vane CFM/CMM Thermo-Anemometer

Heavy Duty Datalogging Light Meter

User Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model

USER GUIDE. Differential Thermometer Datalogger. Model HD200

Large Vane CFM/CMM Anemometer / Psychrometer

Heat Stress WBGT Meter

Mini Digital Multimeter

Digital Sound Level Meter MODEL

Heavy Duty Vibration Meter

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer

Personal Sound Level Meter

Dual Moisture Meter Pin / Pinless Moisture Meter

Indoor Air Quality Meter/Datalogger

USER GUIDE. Coating Thickness Tester. Model CG104

Humidity & Temperature Datalogger

User s Manual. Models Digital Force Gauge. Additional User Manual Translations available at

Earth Resistance and Resistivity Tester

Heavy Duty Pitot Tube Anemometer and Differential Pressure Manometer

User Guide. Moisture Meter. Model MO250

Fruit Hardness Tester

USER GUIDE Turbidity Meter Model TB400

11 in 1 Environmental Meter

True RMS Multimeter with IR Thermometer

Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer. User's Guide

User's Manual. Autoranging Datalogging Insulation Tester (Megohmmeter) with PC Interface. Model

Mini Digital Multimeter Model MN15. User's Guide

User Guide. Video Borescope. Models BR200 and BR250

Humidity + Temp. + Dew Point Pocket size HUMIDITY METER. Model : HT-315

User's Guide. Heavy Duty Conductivity / Temperature. Model Introduction

USER MANUAL Video Particle Counter with built in Camera Model VPC300

Wireless TRMS Multimeter and Insulation Tester

Video Borescope Inspection Camera

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

Digital Sound Level Meter

USER MANUAL. True RMS Multimeter. Extech EX430A

Humidity & Temperature Datalogger

LIGHT METER. Model : LM-81LX. Digital Measurement Metrology, Inc Digital Measurement Metrology, Inc

USER GUIDE. Salinity Meter Pen Style Water Quality Meter. Model EC170

True RMS Industrial Multimeter Extech EX520

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

High Definition VideoScope

Industrial Multimeter Extech EX510

Model LM-81LX. Instruction Manual. Illuminometer. reedinstruments. www. com

User Manual Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer

LIGHT METER OPERATION MANUAL. Model : LM-81LX

OPERATION MANUAL. Model : AM Wind speed measurement, pocket type, IP-65 CUP ANEMOMETER

User's Guide. Video Borescope. Models BR200 and BR250

User's Guide. Extech CG204 Coating Thickness Tester. 99 Washington Street Melrose, MA Phone Toll Free

USER GUIDE. Video Particle Counter with built in Camera. Model VPC300

40.00/400.0/4,000/40,000/400,000 Lux LIGHT METER

User's Guide. Cup Thermo-Anemometer. Model AN400

USER GUIDE. Video Particle Counter with built in Camera. Model VPC300

User's Guide. Vibration Meter and Laser Combination Tachometer Model

VB Model. Instruction Manual. Vibration Meter. reedinstruments. www. com

Autoranging Mini Multimeter

Transcription:

USER GUIDE AC/DC Magnetic Meter Model MF1

Introduction Thank you for selecting the Extech Instruments Model MF1. This device is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Please visit our website (www.extech.com) to check for the latest version of this User Guide, Product Updates, and Customer Support. Features DC and AC magnetic field measurements North and South pole indication Automatic temperature compensation Zero button for DC, AC magnetic function Separate probe for remote measurements High accuracy Advanced functionality with programmable user Settings Ideal for a variety of laboratory and field uses Heavy duty, compact housing with hard shell carrying case Auto power off feature conserves battery energy Easy to read LCD display with green backlight Data Hold and MIN MAX Record Recall features 2 MF1 en GB_V1.7 9/15

Safety International Safety Symbols This symbol indicates the user must refer to the manual for further information. Safety Notes Double insulation o o Remove the battery if the device is to be stored for longer than 6 days. Never dispose of batteries in a fire. Batteries may explode or leak. Cautions o o Read and understand this user manual before operating the meter. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. 3 MF1 en GB_V1.7 9/15

Description Meter Description 1. Probe Connection 2. LCD Display 3. HOLD Button 4. POWER Button 5. REC Button 6. ZERO Button 7. MODE DC/AC/SET Button 8. Tilt Stand and battery compartment on rear 9. Reset Button 1. DC 9V Power Adapter jack 1 2 Fig. 1 Meter Description 3 4 5 6 7 9 1 8 Probe Description 1. Probe Sensing Head 2. Probe Handle 3. Probe cable 4. Probe Head Cover 1 2 4 3 Fig. 2 Probe Description 4 MF1 en GB_V1.7 9/15

Display Description 1. North N or South S indication 2. Unit of measure (G for Gause or mt for millitesla) 3. AC or DC field and resolution information 4. Magnetic reading 1 2 3 Fig. 3 Display Description 4 Button Description 1. POWER Button: Press and hold to power the meter ON or OFF 2. HOLD Button: Short press to freeze displayed reading (HOLD icon will appear); another short press to return to normal operation 3. REC Button: Short press to start recording MAX and MIN readings. Additional short presses will scroll through the saved MAX and MIN readings. Press and hold to exit this mode 4. MODE DC/AC/SET Button: Short presses to scroll through the available units of measure and North/South modes. Long press to access the User Settings menu 5. ZERO Button: Short press to zero the display before taking a reading Reset Button (right side of meter; not pictured below): Press to restore the meter to factory default conditions. If the meter becomes unresponsive use the reset button to restore the meter. 1 2 3 5 4 Fig. 4 Button Description 5 MF1 en GB_V1.7 9/15

Operation AC/DC Magnetic Field Measurement Press and hold the POWER button for at least 2 seconds to switch the meter ON. Use the MODE button to scroll through the following screens in sequence: Under mt unit Under G unit N(S). mt a1 N(S) G a2 N(S). mt b1 N(S). G b2 mt. AC c1 G AC c2. mt AC d1 G. AC d2 Fig. 5 Programming screens Each screen represents the resolution for the respective unit of measure: a1 screen for.1 mt DC resolution measurements b1 screen for.1 mt DC resolution measurements c1 screen for.1 mt AC resolution measurements d1 screen for.1 mt AC resolution measurements a2 screen for 1 G DC resolution measurements b2 screen for.1 G DC resolution measurements c2 screen for 1 G AC resolution measurements d2 screen for.1 G AC resolution measurements 6 MF1 en GB_V1.7 9/15

For DC magnetic field measurements, the display will show either the N or S indicator. For the North Pole, the N indicator will be shown. Similarly, for the South Pole, the S indicator will be shown. For AC magnetic field measurements, the display will show the AC indicator (the N or S indicators will not then be shown). Press the probe head to the testing material (see Fig 6). The display will show the magnetic field value along with the unit of measure (mt = MilliTesla or G=Gauss) and AC, if an AC field. Fig. 6 Touching Probe to Test Material Note: When the meter is powered ON, the display may show a non zero value (because of environmental interference). Before taking a measurement press the ZERO button to null the display. Data Hold During measurements, press the HOLD button and the measured value will be held (the LCD will display HOLD). Press the HOLD button again to exit the data hold function. Data Recording (Maximum and Minimum Reading) Press the REC button to start the data recording function. The LCD will display REC. Press the REC button again and REC MAX along with the maximum reading recorded will appear on the LCD. Press the REC button again to display the minimum value (the LCD will display REC MIN). To exit the data recording function, press and hold the REC button for two seconds. The meter will return to the normal mode of operation. Note: When making DC magnetic field measurements while the RECORD function is active, the user cannot change from North to South pole or vice versa. 7 MF1 en GB_V1.7 9/15

User Settings Press and hold the SET button for two seconds to enter the advanced settings mode. Press the SET button to cycle through the three main functions: POFF Auto power OFF management CLr Factory only diagnostic function UNIt Select the magnetic field units (mt or G) Note: After 7 to 1 seconds the meter will return to the normal operating mode. (POFF) Auto Power OFF The MF1 uses an Auto Power OFF utility to switch the meter off automatically in order to conserve battery energy. This feature can be enabled or disabled: In the Advanced Settings mode, when the LCD displays POFF, press the REC button Use the Zero and Mode buttons to select YES or NO Selecting YES enables the Auto Power OFF feature Selecting NO disables the Auto Power OFF feature (user will then have to switch off manually) Press the REC button to save the setting (UNiT) Selecting Units of Magnetic Field In the User Settings mode when the LCD displays UNIT, press the REC button Use the ZERO or MODE button to select mt or G Select mt for millitesla units Select G for Gauss units Press REC to save the selection Factory only CLR function When in the User Settings mode, with CLr displayed, press REC to skip this step. This is a factory only utility AC Power Adaptor This meter is normally powered by one 9V battery; however an optional 9V power adaptor is available. When the adaptor is used, the meter is permanently powered and the power button is disabled. 8 MF1 en GB_V1.7 9/15

Factory Default Reset If the meter becomes inoperative, it can be reset to factory defaults. Open the side compartment and, with the meter on, press the reset switch. The meter will be reset and the User Settings will be cleared and reset to factory defaults. Battery Replacement When the low battery icon appears on the LCD, the battery must be replaced. Several hours of accurate readings are still possible in this condition; however batteries should be replaced as soon as possible: Remove the Phillips screw from the battery compartment on the rear of the meter. Remove and safely place the battery compartment and screw where they will not be damaged or lost. Replace the 9V battery observing correct polarity. Replace the battery compartment cover with the Phillips screw. Note: The meter can also obtain power from the DC 9V Power Adapter. The meter will be permanently powered ON when the adapter is used (the power button is disabled). All EU users are legally bound by the battery ordinance to return all used batteries to collection points in the community or wherever batteries / accumulators are sold! Disposal in the household garbage is prohibited! 9 MF1 en GB_V1.7 9/15

Specifications Circuit Display (LCD) Size Custom one chip microprocessor LSI circuit 52 x 38mm (2. x 1.5 in.) Measurement Units mt MilliTesla G Gauss Measurement Range, DC mt Range 1 3. mt x.1 mt Range 2 3,. mt x.1 mt G Range 1 3,. G x.1 G Range 2 3, G x 1 G Measurement Range, AC mt Range 1 15. mt x.1 mt Accuracy At 23 C +/ 5 C Frequency Response Sensor Field Direction Display Sampling Time Operating Temperature Operating Humidity Power Supply Power Consumption Weight (meter and probe) Dimensions Range 2 1,5. mt x.1 mt G Range 1 1,5. G x.1 G DC AC Range 2 AC Measurement: 5 Hz / 6 Hz 15, G x 1 G ± (5% rdg. + 1 dgt.) ± (5% rdg. + 2 dgt.) Hall Effect Sensor with Auto Temperature Compensation Uni axial Approx. 1 second to 5 C (32 to 122 F) Less than 85% R.H. 9V Battery Universal AC adaptors included Approximately 15mA DC 275g (9.7 oz.) Main Instrument: 198 x 68 x 3 mm (7.8 x 2.67 x 1.18 in.) Probe: 195 x 25 x 19 mm (7.68 x.98 x.75 in.) Copyright 215 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form ISO 91 Certified www.extech.com 1 MF1 en GB_V1.7 9/15