PCR43301RE ELSEMA. . and anywhere else you need a wireless signal to transmit a contact closure. Description

Similar documents
PCR43302RE, PCR43302R 2-Channel, 433MHz Penta Receiver with Relay outputs

PCR43301RE 1-Channel, 433MHz Penta Receiver with Frequency Hopping

PCR R 2 Channel, 433MHz Penta Receiver with Frequency Hopping

PCR43304R, PCR43304RE 4-Channel, 433MHz Penta Receiver with Frequency Hopping

PCR R, PCR RE 2 Channel, 433MHz Penta Receiver with Frequency Hopping

PCR43304R, PCR43304RE 4-Channel, 433MHz Penta Receiver with Frequency Hopping

PentaTimer Receiver Two Channels, 433MHz Penta Receiver with Time Clock Functions

ELSEMA GLR Applications Automatic gates. Security systems. Timer controlled outputs. Simple on/off functions.

GLR43303, GLR43304 Multi-Channel 433MHz Gigalink Receiver

Eclipse MCi. Variable Speed Drive Controller with Eclipse Operating System (EOS) 3rd Edition. VSD kits suitable for motors ranging from 0.4 to 2.

User Manual. PCKeypad Wireless Keypad

SHENZHEN Lejing INDUSTRY DEVELOPMENT CO.LTD Whatsapp:

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ )

Wireless Key fob, Key pad & Receiver Range

G G receiver with relay output for opening sliding, swing gates, doors or switching devices

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

ELSEMA 3 Phase Control Board, 3PH2, 3PHE

GL116 ENCODER/DECODER MANUAL GLOLAB CORPORATION

Installing Keypad and Backplate

Digital Keypad Introduction

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

Applications. Quark-Elec Application Note

RF4431 wireless transceiver module

SPX-5000 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface. RPT GHz Repeater. SPX GHz

Suprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316

e-ask electronic Access Security Keyless-entry RF Keyless-entry entry System TM-Multi Multi Installation Manual FCC ID: TV2EFOB1 (UM21 ~ )

902 MHz Wireless Relays Application Manual Bulletin B1867

WLS-TC Specifications

GL-104 ENCODER/DECODER MANUAL GLOLAB CORPORATION

U-FLASH Setup Guide U-FLASH.

Wiring Inside the card reader you will see a circuit board. The connections are as follows:

UP200-GSM Intercom and access control unit operating on mobile GSM network

SmartLock Controller INSTALLATION MANUAL

Wireless Expansion Module V2.0 OMN-RCV3. Reference & Installation Manual. Stand-Alone System

6222 Two Door Module Technical Operations Manual

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual

PS-4100 POWER SUPPLY MANUAL

e-ask electronic Access Security Keyless-entry

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

THE BRIDGE. Make any Wiegand device wireless with the Sure-fi Bridge FEATURES. Technology

Telephone Line Monitor USER GUIDE

UC-2000 Installation Manual Unicorn Computers Technology Limited

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

Seven Channel Remote Control

Installation & User Manual

AS Keypad User Manual

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

Blue Point Engineering

UP100-GSM. GSM based intercom and access control. Installation and user manual

SMART SHOT CONTROLLER FLUID USERS GUIDE

GSM GATE INTERCOM WITH KEYPAD Control your gate with your mobile phone

902 MHz Wireless Relays Application Manual Bulletin B1867

Installation & User Manual V2.08

VIS-3200 / VIS-3201 User Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual

PLEASE READ BEFORE INSTALL. ECGO-GKP Cellular Telephone Entry

RF4432 wireless transceiver module

Quick Start Guide. ELPRO 105U-L Wireless I/O Receiver Unit. man_105u-l-r_quickstart_v1-8.doc

Control Panel for Swing Gates. Model: CP-12 / January 2007

LH Long Range Business Wireless Doorbell Kit User Manual

Home Security System with Remote Home Automation Control

RFID/Digital Access Control Keypad

Click Save to return to the main Setup screen.

Comsec Protection Systems

CM-500 SK 500 USER CODES KEYPAD

page A.0240 Full_Product_catalogue_ BM.indb 118

ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox

SmartLock Pro INSTALLATION MANUAL

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD

Mobile Phone Smartphone WIFI Controller 8 Channel Relay Output

DO NOT LOSE THIS SHEET - YOUR FACTORY MASTER CODE IS UNIQUE TO YOUR KEYPAD

Model SFS01-V2 IMPORTANT! MULTI-ATTEMPT AUTOMATIC ENGINE SMART SWITCH

GSM HOME SECURITY SYSTEM

USERS MANUAL FOR ERNEST BLUETOOTH GATES

180 Series Keypad. Handbook. Revision 2.1

Each receiver has 4 switched outputs, which, using our one touch easy-learn process can be controlled from any switch on any compatible transmitter.

RadioRA 2 Visor Controls

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

GSM 2G/3G MULTI SWITCH 240v

4-Megabit (512K x 8) 5-volt Only CMOS Flash Memory AT49F040 AT49F040T AT49F040/040T AT49F040/040T. Features. Description. Pin Configurations

MSS-UP200-GSM Single Dwelling GSM Intercom Unit. Operation Manual. [Ver /5/2015]

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

SMS Transceiver V3 User manual

GSM 2G/3G MULTI SWITCH 12v

Technology Security Low consumption

2-Way Wireless I/O Expander Installation Guide

Installation advice / help

Innovative Electronics for a Changing World. NPM-R10 Remote Network Power Monitor. With optional relay board and GSM module INDEX

T4HD: Installation Supplement R8.1.13

Modules Programming Guide. paradox.com

Emergency Dialer DIAL-ALERT MODEL: AD-433S.

Remote control access is where security and convenience meet. Centurion Systems has a range to comply with your site s unique security requirements,

D2112 Keypad Diagnostics

Solid State Relays and Timers Family

212iL Rev. 1.1

CB17 CONTROL SYSTEM USER MANUAL

PC170 Control Box USER MANUAL 24V DC GEAR MOTOR FOR RESIDENTIAL

Stand-Alone Data Chip System

Torque Control Verifier

Transcription:

PCR43301RE 1-Channel, 433MHz Penta Receiver with Frequency Hopping Features Frequency hopping between 433.10 to 434.70MHz 12-way dipswitch or encrypted coding Compatible with PentaFOB and PentaCODE remotes Unlimited remotes can be programmed to the receiver Wide operating supply voltage and low current consumption Momentary and latching modes are user selectable. On-board diagnostic LED s to indicate correct power, reception and relay activation Applications Keyless access control for automatic gates and doors Home automation i.e. garden lights, swimming pool control etc. Security, lighting and automotive controls. and anywhere else you need a wireless signal to transmit a contact closure Description This receiver is compatible with PentaFOB and PentaCODE remotes. The receiver is so small that it can be easily installed into your existing automatic gate opener or garage door controls. Other applications include light control, security shutters or anywhere else you need a wireless signal to transmit a contact closure. The PentaCODE dual coding system gives the installer the option to use the classic 12-way dip switch coding or one of over 17 billion encrypted codes. With the 12-way dip switch, just match the keyring remotes and the receiver's dip switch and it's coded. With the encrypted code you switch all the 12-way dip switches OFF and the remote and receiver automatically goes into the encrypted coding. Please see coding instructions for encrypted coding procedure. Wiring Diagram

Output Modes (On receivers purchased after February 2017) Relay output on the receiver can be set to function in different modes. By default the mode is set to momentary. 3- way Dipswitch setting Ch1 Modes "Momentary" Relay stays ON for as long as the transmitter button is pressed. Press and hold "Latching" Relay remains ON until next press of the transmitter button. Similar to switching "on" and "off" a light. "Delayed Off " Relay stays ON for 1-300 seconds, adjustable by trimpot. "On-Off" This mode requires a 2-channel or a 4-channel remote. Receiver Relay 1: Channel 1 will always switch the relay ON Channel 2 will always switch the relay OFF "Instant OFF " Same is "Delayed Off " except relay will switch OFF as soon as the PCK43304W input is deactivated. "Security latching " Relay will switch ON and stay ON until supply to receiver is momentarily interrupted. Customised Software Custom output modes can be programmed to do special functions. Call Elsema for more details.

Products in the Range PCR43301RE 1-Channel Receiver with Relay Output. Enclosed in a case PCR43302P 2-Channel Plug in type Receiver with Open Collector Output PCR43302R 2-Channel Receiver with Relay Outputs PCR43302RE 2-Channel Receiver with Relay Outputs. Enclosed in a case PCR43301240R 1-Channel Receiver with 240VAC mains supply PCR43301240RE 1-Channel Receiver PCR43302240R 2-Channel Receiver with 240VAC mains supply PCR43302240RE 2-Channel Receiver PCR43304R 4-Channel Receiver with Relay Outputs PCR43304RE 4-Channel Receiver PCR43305R 5-Channel Receiver with Relay Outputs PCR43305RE 5-Channel Receiver

Technical Data Supply Voltage 12 to 24 Volts AC or DC Standby Current 21mA standby at 24VDC Current Consumption 42mA with relay On Frequencies 433.100 to 434.700MHz Receiver Sensitivity Better than 0.316uV (-117dBm) Operating Temperature Range -5 to 50 C Receiver Memory Storage Unlimited Remotes Decoding System Encrypted 17 billion codes combinations or On board 12-way code switch Outputs 1 change over relay output, rated at 8 Amps 240VAC Relay Contacts Common (C), Normally Closed (NC) & Normally Open (NO) Connections 50cm Flying leads for supply and relay output. See block diagram Antenna 1 ANT433 series for long range applications. Antenna wire for short range applications Operating Range Refer to the remote control or transmitter datasheet Dimensions 70mm x 55mm x 25mm Weight 70grams Useable Transmitters FOB433 series and PCK series

PentaFOB Programming Instructions Coding the PentaFOB remotes and receivers can be done in 2 different ways. 1. Remote to Receiver 2. Remote to Remote Remote to Receiver 1. Check that all switches are OFF on the receivers 12-way dip switch 2. Press and hold the program button on the receiver 3. Press the remote button for 2 seconds, receiver LED will flash and then turn Green 4. Release the button on the receiver and the remote 5. Press remote control button to test the receiver output 6. Remote to Remote (you should be near the receiver for this procedure) *Only follow the following procedure if your receiver has a red marking as shown in the picture. If your receiver does not have this marking, follow the procedure which is in the orange text. 1. Open the case of a remote control that is already programmed and press and release the program button on the back of the board (The receiver enters learning mode) 2. Press the button of the remote in step 1 which activates the receiver 3. Press the button on the new remote which needs to be programmed for 2 seconds 4. Press the program button again of the remote in step 1(The receiver exits learning mode) 5. Press the new remote control button to test the receiver output For receiver s which do not have the red marking 1. Open the case of a remote control that is already programmed and press and release the program button on the back of the board 2. Press the new remote control button for 2 seconds 3. Press the new remote control button again to test the receiver output Deleting Receivers Memory Short the Code Reset pins on the receiver for 10 seconds. This will delete all the remotes from the receiver s memory. PentaFOB Programmer This programmer allows you to add and delete certain remotes from the receiver memory. This is used when a remote control is lost or a tenant moves from the premises and the owner wants to prevent un-authorised access. PentaFOB Backup Chips This chip is used to backup or restore the contents of a receiver. When there are 100 s of remotes programmed to a receiver the installer normally backups the receiver memory in case the receiver is damaged.

PentaCODE Programming Instructions 12- Way Dip Switch Coding 1. Set a random code on the receiver dip switch by flicking the dip switches "On" or "Off". (DO NOT USE THE DEFAULT FACTORY SETTING FOR THE 12-WAY DIP SWITCH AS THIS IS A COMMON CODE) 2. Open the battery cover in the PentaCODE remote. 3. Match the 12-way dip switch to the receivers 12-way dip switch. 4. Press button 1 on the remote and the receiver output should activate. This is indicated by the receiver LED. To program the same PentaCODE remote buttons 2, 3 or 4 to another receiver change dip switch 11 and 12 in the 2nd, 3rd and 4th receivers. For example: Receivers Dip Switch 11 Receiver Dip Switch 12 Receiver 1 Off Off Receiver 2 On Off Receiver 3 Off On Receiver 4 On On Dip switches 1 to 10 should all be the same in the remotes and the receivers. Encrypted Coding - (All 12-Way Dip Switches must be "Off") Coding the PentaCODE remotes and receivers can be done in 3 different ways. 1. Receiver to a Remote 2. Remote to a Receiver 3. Remote to a Remote Receiver to a Remote 1. Press and hold the program button 1 on the receiver. 2. Press the remote button you want to program for 2 seconds, receiver LED will flash Green 3. Release the button on the receiver and the remote. 4. The LED on the PentaCODE remote will flash to confirm the coding has been successful. Remote to a Receiver / Remote to a Remote Set one of the remotes or receivers to broadcast its code. The broadcaster s code will be programmed to the other units. - To broadcast the remotes code make sure all 12 dip switches are "off". Then press and hold button 1 and flick dip switch 12 "on" and then "off". This is confirmed by the LED's being on for 10 seconds. You can release the remotes button 1. - To broadcast the receivers code make sure all 12 dip switches are "off" and then flick dip switch 12 "on" and then "off". This is confirmed by the green LED being on for 10 seconds. While broadcasting the code press button 1 on a different remote or receiver for 1 second and then release the button. The LED will flash twice to confirm successful programming. Broadcasting will be latched on for 10 seconds or stop if any dipswitch is turned on. Deleting Receivers Memory Short the CC pin on the receiver for 10 seconds. This will delete all the remotes from the receiver s memory.