(XP-8048-CE6/XP-8348-CE6/XP-8748-CE6)

Similar documents
Win-GRAF ViewPAC VP-1238-CE7. Features. Introduction. Windows Embedded Compact 7. Win-GRAF 5.7" TFT LCD. Win-GRAF ViewPAC Series 5.

Win-GRAF ViewPAC VP-4238-CE7 VP-6238-CE7 VP-1238-CE7. Features. Introduction. Windows Embedded Compact 7. Win-GRAF. Win-GRAF ViewPAC Series

Win-GRAF ViewPAC. Features. Introduction. Windows Embedded Compact 7. Win-GRAF. Win-GRAF ViewPAC Series

XP-8147-Atom-CE6. XP-8347-Atom-CE6. XP-8747-Atom-CE6

(XP-8137-CE6/XP-8337-CE6/XP-8737-CE6)

8.2. WinPAC-5000 Series

XP-8346-CE6 XP-8346-CE6-PRO

WP-8137 WP-8437 WP-8837 WP-8847 WP-8757

2.2. WinPAC-8000 Series

2.2. XP-8000 Series. Overview. XP-8000 Series. Compact PAC. XP-8000 Series XP-8000 IPC+I/O Cards

I-8KE4-MTCP I-8KE8-MTCP ET-7000 ET-7000 NS-205. RU-87Pn I-7000 M CAN/CANopen Devices I-7530 I-8KE4-MTCP NS-205 M-7000.

2.1. XP-8000 and XP-8000-Atom Series

2.4. LinPAC-8000 Series

VP-4147 VP IT and Instrumentation for industry. Features. Introduction. ISaGRAF Features

2.5. ipac-8000 Series

WP-8847 WP-8447 WP-8147

ViewPAC ViewPAC Overview P3-1-1

Win-GRAF Jul. 24, 2017

XP-8000-CE6 Series User Manual

UA Series IIoT Communication Server

UA-5200 IIoT Communication Server

Redundant System Redundant System P9-1-1

WinCon Programmable Automation. Controller

WISE-52xx Intelligent IIoT Concentrator

7188/7186 Series μpac

WISE I/O Modules Overview P10-1-1

RS-485 Products. ICP Electronics Australia Pty Ltd Communication Cards for PC/IPC P 2-1

Software Development: ISaGRAF V.S. C++ and VS.net Via I-7530 to connect CAN/CANopen devices

I/O Expansion Units. 5.1 I/O Expansion Units Overview P Overview P RS-485 I/O Expansion Unit P5-2-1

5.3. Ethernet I/O Expansion Unit

I/O Expansion Units I/O Expansion Units Overview P RS-485 I/O Expansion Unit P Modbus TCP I/O Expansion Unit P6-3-1

Table of Contents. 1. Overview Total Solutions for Machine Automation... 1

PAC Products Overview P1-1-1

UA-5000 Series User Manual

3-7 Tiny Serial-to-Ethernet Device Server & Modbus Gateway

ADAM-5000 Series. Distributed I/O Systems. PC-based Controllers. Introduction. Open Network and Fieldbus Solutions for Device Networking 13-27

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

Version January 18th, 2018

ICP DAS DeviceNet Total solutions

September 18th, 2018

XP 8X4X-Atom CE6 OS Release Note, Version [Mar., 18, 2011]

Features. Support XV-board

Our Intelligent Solutions and Comprehensive Service, Your Key to Success.

ICP DAS. ICP DAS 2013 M2M ZigBee Wireless Solutions

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

Features and Benefits. Certifications

Standard protocol support (e.g. MODBUS, SNMP, M-Bus), possibility to install dedicated user protocols

PROFIBUS Products. ICP Electronics Australia Pty Ltd Overview P 5-1

Touch HMI Devices. The Best Choice for Building/Factory/Machine/Home Automation. Introduction. Features. Touch HMI Devices.

Getting Started : VP-25W7, VP-23W7

HART Products. ICP Electronics Australia Pty Ltd Overview P 6-1

Getting Started: I / / 8437/8837/8417/8817

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

FCC 47 CFR PART 15 SUBPART B

Programmable Automation Controllers

Feature and Benefits. Certifications

Arm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits. Certifications

USB Keyboard Mouse. VGA Compact Flash

IP66. Features. Introduction. 1 ICP DAS CO., LTD. Professional Provider of High Quality Industrial Computer Products and Data Acquisition Systems

TouchPAD TPD/VPD Series HMI Device User Manual

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

WinPAC-8000 User Manual (Standard series solution)

IT and Instrumentation for industry. Features. Introduction. Applications

3-7 Tiny Serial-to-Ethernet Device Server & Modbus Gateway

Ethernet I/O Products

VERIFICATION OF COMPLIANCE

Related Products. Ethernet Modbus LED Display

User s Manual of ISaGRAF Embedded Controllers

XP-8000-CE6 User Manual, version Last Revised: February 2010 Page: 1

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

VP-23Wx-SC: Simplified Chinese VP-23Wx-TC: Traditional Chinese.NET Compact Framework 2.0.NET Compact Framework 3.5

WLAN Products 2.1 Overview P WLAN Remote Maintenance Device P WLAN Converter P Applications P2-4-1

LMC078CECS20T motion controller LMC078-20DIO transistor sercos compact Ethernet Canopen 24Vdc

DCON Utility User s Manual Version 1.1, April 2006

Standard protocol support (e.g. MODBUS, SNMP, M-Bus), possibility to install dedicated user protocols

Table of Contents. Multi-port Serial Cards. Serial Device Server. Converters, Repeaters, Hubs and Splitter. Ethernet Switches

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

Industrial Gateway Solutions

Overview. Complete Application-Ready Platforms for General Motion Control Tasks. AMONet - Advantech Distributed Motion Control Solutions 14-2

CIMON-PLC CIMON-HMI CIMON-TOUCH CIMON-Xpanel

DCON Utility Pro User s Manual Version 1.1, May 2015

ModBerry400 series. Features of ModBerry400 NEW PROCESSOR MODULE 3

VERIFICATION OF COMPLIANCE This Verification of Compliance is hereby issued to the product designated below.

RS-485 I/O Products P 3-2. Ethernet I/O Products P CAN Bus I/O Products P PROFIBUS I/O Products P FRnet Products P 3-44

This document provided by Barr-Thorp Electric Co., Inc

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

Getting Started : W-8037/8337/8737. The Web PAC

These modules also provide advanced features like data sharing and UDP ß ood attack protection as follows: Client C. Single-Board Computer (SBC)

NPEX500 series. Features of NPEX500 M3 NEW PROCESSOR MODULE 3

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System

Features and Benefits. Certifications

VP-23W1/VP-25W1 User Manual

User Manual. cmt-svr Startup Guide

WP 5000 CE 5.0 OS Release Notes

WinPAC 8000 User Manual

MGate 5105-MB-EIP Series


iologik E1200H Series

Standard protocol support (e.g. MODBUS, SNMP, M-Bus), possibility to install dedicated user protocols

RTU32S RTU32S Series Small Compact Utility RTU

Transcription:

Win-GRAF XPAC-8000-CE6 Series XP-8048-CE6 XP-8348-CE6 XP-8748-CE6 Features LX800, 500 MHz CPU Windows CE 6.0 R3 Core Embedded Win-GRAF SoftLogic (IEC 63-3) Hard Real-Time Capability VGA Port Output Modbus RTU/TCP (Master, Slave) Support Soft-GRAF HMI Redundant Power Inputs Support Dual PAC Redundant System Operating Temperature: -5 ~ +75 C Introduction The Win-GRAF XPAC-8000-CE6 Series (XP-8048-CE6/XP-8348-CE6/XP-8748-CE6) is the new generation WinCE 6.0 based (Programmable Automation Controller) from ICP DAS. Each is equipped with an AMD LX800 500 MHz CPU running a Windows CE 6.0 R3 Core operating system, a variety of input/output ports (VGA, USB,, RS-3/485), and a range of I/O slots (0/3/7) that can be used to integrate high performance parallel I/O modules (high profile I-8K Series) or serial I/O modules (high profile I-87K series). The benefits of running Windows CE 6.0 on a XPAC-CE6 device include hard real-time capability, achievable deterministic control and allowing PAC can have a PC-like window displays and operating environment. The PACs are capable of running Win-GRAF (IEC 63-3 Standard) software to develop logic control applications, and also supporting M.S. VS 008 software (VB.NET, C#) to develop HMI and data management applications that can exchange data with Win-GRAF applications. So the application's design is more convenient and more practical. Win-GRAF Win-GRAF is a powerful, PLC-like, softlogic development software. It is installed on PC with windows 7 or 8. It supports the international PLC language standard - IEC 63-3 - Ladder Diagram (LD), Function Block Diagram (FBD), Sequential Function Chart (SFC), Structured Text (ST), Instruction Set (IL), suitable to develop applications for the full range of Win- GRAF PACs from ICP DAS. The features of the Win-GRAF: IEC 63-3 Standard Open PLC Syntax (LD, FBD, SFC, ST, IL) Using ST Syntax in the FBD or LD Program Event Triggered Data Binding (Exchange Data between PACs) On Line Debug/Control/Monitor, Off Line Simulation On Line Change Various Protocols: - Modbus TCP/UDP, Modbus RTU/ASCII Master - Modbus TCP, RTU Slave - DCON... Plenty of Functions, Function Blocks, I/O Boards Redundancy (For XP-8xx8-CE6 PAC only) ICP DAS CO., LTD. Professional Provider of High Quality Industrial Computer Products and Data Acquisition Systems Vol. PAC.4.503

Programmable Automation Controller Products Applications Redundant System - Only CPU is Redundant Only CPU is Redundant Redundant System - Both CPU and I/O Modules are Redundant Both CPU and I/O Modules are Redundant Website: http://www.icpdas.com E-mail: sales@icpdas.com Vol. PAC.4.503

WP-8447 Win-GRAF XPAC-8000-CE6 Series Applications Modbus Master Ports On Line Change XPAC XP-8xx8-CE6 WinPAC WP-8xx8 WP-5xx8-CE7 ViewPAC VP-xx8-CE7 Modbus RTU/ASCII Master NS-08 Modbus Device M-7000 Modules RS-485 Modbus TCP/UDP Master Modbus TCP/IP Slave tm-7000 I/O Modbus TCP/IP Slave PLC Modbus TCP/IP Slave Meter or ISaGRAF PAC Replace the current running project to a new modified one without stopping the project Modbus TCP/IP Master Protocol idcs-8000 Redundant I/O ET-7000 I/O tpet-7000 I/O Win-GRAF XPAC support max. 00 devices. Win-GRAF WinPAC & ViewPAC support max. 3 devices. Modbus RTU/TCP Slave Ports HMI HMI SCADA RS-3 RS-485 RS-3 RS-3 RS-4 Support VS 008 Development The s support to use VS 008 (VB.net, C#) to develop user own HMI and data management programs, and can exchange variables with the Win- GRAF control programs. Multi-serial ports modules ( I-8iW/ 4W/ 4iW/ 4iW/ 44iW ) HMI SCADA DCON Remote I/O Data Binding 3 ICP DAS CO., LTD. Professional Provider of High Quality Industrial Computer Products and Data Acquisition Systems Vol. PAC.4.503

Programmable Automation Controller Products Soft-GRAF Colorful HMI Schedule Control Intelligent Win-GRAF 3G Solution Only the WG-Communication Server (behavior like a Cloud Server) needs a public IP (Support Domain Name). Other PACs and PCs that connect to this Server no need a public IP. The user can monitor the remote PAC by using a 3G wireless network or an intranet. The user can use the Win-GRAF Workbench to connect to a remote PAC to debug/update the Win-GRAF program or update the Win- GRAF PAC Driver. The PAC can actively send a Log File to a PC (WG-Communication-Server). Create Your Own Functions and Function Blocks For some reason (like business protection, integration with your own product protocol, and etc.), you can develop your own functions and function blocks by VS 008. Then, you can use these functions and function blocks in the Win-GRAF project. PID Control Can Control more than 00 PID in one PAC. Website: http://www.icpdas.com E-mail: sales@icpdas.com Vol. PAC.4.503 4

Win-GRAF XPAC-8000-CE6 Series Specifications Models XP-8048-CE6 XP-8348-CE6 XP-8748-CE6 System Software OS Windows CE 6.0 R3 Core.Net Compact Framework 3.5 Embedded Service FTP Server, ASP (Java Script, VB Script), SQL Compact Edition 3.5 SDK Provided Dll for Visual Studio.Net 005/008 Multilanguage Support Development Software English, German, French, Spanish, Russian, Italian, Czech, Japanese, Korean, Simplified Chinese, Traditional Chinese Win-GRAF IEC 63-3 standard. Win-GRAF Languages LD, ST, FBD, SFC & IL; Support Soft-GRAF HMI: WP-8xx8, WP-5xx8-CE7, WP-9xx8-CE7, XP-8xx8-CE6 and VP-xx8-CE7 PAC Software Max. Code Size MB Scan Time 3 ~ 5 ms for normal program; 5 ~ 50 ms for complex or large program Non-Win-GRAF Options: VS.NET 008 (VB.NET, C#.NET, C) CPU Module CPU LX800, 500 MHz System Memory 5 MB DDR SDRAM Dual Battery Backup SRAM 5 KB (for retaining variables) Flash 4 GB EEPROM 6 KB CF Card 4 GB (support up to 3 GB) RTC (Real Time Clock) Display seconds, minutes, hours, date, day of the week, month, year Programmable LED Indicator - 64-bit Hardware Serial Number Yes, for Software Copy Protection Dual Watchdog Timers Yes Rotary Switch Yes (0 ~ 9) DIP Switch - Yes (8 bits) Audio - VGA & Communication Ports VGA Yes (Resolution: 04 x 768, 800 x 600, 640 x480) RJ-45 x, 0/00 Base-TX (Auto-negotiating, Auto MDI/MDI-X, LED indicators). USB.0 COM RS-3 (RxD, TxD and GND); non-isolated Internal communication with the high profile I-87K series modules in slots COM RS-3 (RxD, TxD and GND); non-isolated COM 3 RS-485 (Data+, Data-) with internal self-tuner ASIC; 3000 VDC isolated COM 4 RS-3/RS-485 (RxD, TxD, CTS, RTS and GND for RS-3, Data+ and Data- for RS-485); non-isolated COM 5 RS-3 (RxD, TxD, CTS, RTS, DSR, DTR, CD, RI and GND); non-isolated I/O Expansion Slots Number of Slots 0 3 7 Note: For High Profile I-8K and I-87K Modules Only Mechanical Dimensions (W x L x H) 37 x 3 x 5 (mm) 3 x 3 x 5 (mm) 355 x 3 x 5 (mm) Installation DIN-Rail or Wall Mounting Environmental Operating Temperature -5 ~ +75 C Storage Temperature -30 ~ +80 C Ambient Relative Humidity 0 ~ 90% RH (non-condensing) Power Input Range +0 ~ +30 VDC Isolation kv Redundant Power Inputs Yes, with one power relay ( A @ 4 VDC) for alarm Capacity 5 W 35 W 35 W Consumption 4.4 W 4.4 W 6.8 W 5 ICP DAS CO., LTD. Professional Provider of High Quality Industrial Computer Products and Data Acquisition Systems Vol. PAC.4.503

Programmable Automation Controller Products Win-GRAF Specifications Protocols (Note that certain protocols require optional devices) NET ID ~55, for Modbus TCP/RTU Slave, user-assigned Modbus TCP Master A max. of 00 IP links to access/control the devices supporting Standard Modbus TCP Slave protocol. A max. of 3 ports: COM ~ 33 to connect other Modbus Slave devices (Like M-7000). Recommend Modbus RTU/ASCII Master connecting no more than 3 devices in each port for better scan rate. (*) Modbus RTU Slave A max. of 6 ports: COM ~ 33 for connecting SCADA/HMI/OPC Server. (*) Two ports (LAN & LAN) support up to 64 connections. If the PAC uses connection to connect Modbus TCP Slave each PC/HMI, it can connect up to 64 PCs/HMIs; If the PAC uses connections to connect each PC/HMI, it can connect up to 3 PCs/HMIs; If one of the port malfunctions, the other one can still be used to connect the PC/HMI. User-defined Protocol Custom protocols can be applied at COM~33 by using Serial communication functions or function blocks. (*) A max. of 6 RS-485 ports: COM ~ 33. Each port can connect max. 50 nos I-7000 series modules or 50 DCON Remote I/O nos I-87xxxW I/O modules in expansion units (I-87K4, I-87K8, I-87K9, RU-87P8, RU-87P4). Recommend connecting no more than 3 modules in each port for better scan rate. Local I/O Modules Supports only high profile I/O modules. Slot ~7 supports I-8xxxW parallel I/O modules and I-87xxxW serial I/O modules. (Refer Optional I/O List) Using the unique 64-bit (8 bytes) PAC serial number to generate a protection password by your own App Protection algorithm to protect your Win-GRAF application. Then, if someone intend to copy your application in the PAC to another new PAC with the same PAC model, this application will not work properly in that new PAC. XP-8xx8-CE6 can set a redundant system, when one is damaged or crashes, the other can still take up and continue the work. The system offers 3-line communication redundancy, LAN, LAN and Alive Port Redundancy (COM5), as long as one of the three communication lines still connects normally, this redundant system can normally control the process. The redundant system provides a public IP address that allows SCADA/HMI software to access it without needing to determine which one is the Active IP. Exchange data between ICP DAS via ports (LAN and LAN). The data Data Binding transmission is event triggered. It is much efficient than polling way. Beside, user can setup the Redundant Binding in two ethernet ports by Software, then if one port fail, it can switch to use the other port. On Line Change For application field that not allowed to stop the Win-GRAF program and wish to run a new program modified a little from the original program. Modbus RTU I/O When software enables Modbus RTU Master function, the PAC can connect ICP DAS M-7000 and tm series and LC series I/O modules which support Modbus RTU protocol. Modbus TCP I/O When software enable Modbus TCP Master function, the PAC can connect ET-7000, I-8KE4/8-MTCP and tpet/tet series I/O modules of ICP DAS which support Modbus TCP protocol. Hart Master Support I-87H7W modules in slot to 7 to communicate with other HART devices. Schedule Control Supports the "Schedule-Control Utility" (free) to implement schedule control. Each PAC can control max. 0 Targets (devices) with different schedule settings in each day / holiday / special day / season / year. Retain Variables Built-in the fast retain memory that can retain up to,000 Win-GRAF variables. File Access & Data Log The Win-GRAF supports file operation functions to read/write files in the PAC's micro_sd or flash memory to do data log or file access. Soft-GRAF HMI Support to run HMI program (developed by the Soft-GRAF Studio) together with the Win-GRAF logic-control program in the same PAC. Optional I/O List (Refer to http://www.icpdas.com/root/product/solutions/remote_io/rs-485/i-8k_i-87k/i-8k_i-87k_selection.html#a) Digital Input (DI) I-8040W, I-8040PW, I-8046W, I-805W, I-805W, I-8053W, I-8053PW, I-87040W, I-87040PW, I-87046W, I-8705W, I-8705W, I-87053W, I-87053PW, I-87053W-A, I-87053W-A5, I-87053W-E5 Digital Input/Output (DIO) I-804W, I-8050W, I-8054W, I-8055W, I-8704W, I-87054W, I-87055W Digital Output (DO) I-8037W, I-804W, I-804AW, I-8056W, I-8057W, I-87037W, I-8704W, I-87057W, I-87057PW Relay Output I-8060W, I-8063W, I-8064W, I-8068W, I-8069W, I-8706W, I-8706PW, I-87063W, I-87064W, I-87065W, I-87066W, I-87068W, I-87068W-A, I-87069W, I-87069PW AC Input I-8058W, I-87053W-AC, I-87058W, I-87059W Analog Input (AI) I-807DW, I-807HW, I-807HCW, I-8707W, I-8707RW, I-8707RCW, I-8707DW, I-8707W-A5, I-8707ZW, I-8708W, I-8708RW, I-8708PW, I-8708ZW, I-8709PW, I-8709RW, I-8709ZW Analog Output (AO) I-804W, I-8704CW, I-8704UW, I-8704DW, I-8704RW, I-8704W, I-8708CW, I-8708UW, I-8708VW, I-8708VW-0V Multifunction (DIO, AIO) I-8706W Temperature Input T/C: I-8708W, I-8708RW, I-8708PW, I-8708ZW, I-8709PW, I-8709RW, I-8709ZW Thermister: I-87005W; RTD: I-8703W, I-8705W, I-8705PW Strain Gauge I-8706W Counter/Frequency Input I-8084W, I-8708W, I-87084W Encoder Input I-8093W PWM Output I-8088W HART I-87H7W GPS GPS-7 Communication Module I-8iW, I-84W, I-84iW, I-84iW, I-844iW Temperature & Humidity Input DL-00T485, DL-00T485-W, DL-00T485P, DL-00T485P-W (DCON Protocol) DL-00TM485, DL-00TM485-W, DL-00TM485P, DL-00TM485P-W (Modbus RTU Protocol) * Note: The COM6 ~ COM33 ports are located in the expansion boards if they are installed in slot ~7 of XP-8xx8-CE6. * Only XP-8048-CE6 has COM. * ICP DAS recommends using NS-05/08 or RS-405/408 (Ring Switch) Industrial Switches. Website: http://www.icpdas.com E-mail: sales@icpdas.com Vol. PAC.4.503 6

Win-GRAF XPAC-8000-CE6 Series Appearance XP-8048-CE6 XP-8348-CE6 COM4 (RS-3/RS-485) Power Switch Rotary Switch COM5 (RS-3) Power LED Indicator Port USB.0 Ports COM5 (RS-3) Power & Ground COM3 (RS-485) COM (RS-3) Pin Assignment COM (RS-3) Redundant Power and Ground Relay Output R.COM and R.NO Frame Ground COM4 (RS-3/RS-485) COM (RS-3) COM3 (RS-485) Port CF Card Slot VGA Port 3 I/O Slots DIP switch COM: RS-3 COM: RS-3 COM3: RS-485 COM4: RS-3/485 COM5: RS-3 Note: Only XP-8048-CE6 has the above COM Port. Ordering Information XP-8048-CE6 CR XP-8348-CE6 CR XP-8748-CE6 CR 0 I/O slot WinCE 6.0 Based Win-GRAF XPAC (OS: Multi-Language version) (RoHS) 3 I/O slots WinCE 6.0 Based Win-GRAF XPAC (OS: Multi-Language version) (RoHS) 7 I/O slots WinCE 6.0 Based Win-GRAF XPAC (OS: Multi-Language version) (RoHS) Software and Accessories Win-GRAF Development Software Win-GRAF Workbench Win-GRAF Workbench Software (Large I/O Tags) with one USB Dongle Accessories DP-660 DP-00 CR MDR-60-4 CR NS-05 CR / NS-08 CR RS-405 CR / RS-408 CR TPM-400/TP-400 4 VDC/.5 A, 60 W and 5 VDC/0.5 A,.5 W Power Supply with DIN-Rail Mounting 4 VDC/5.0 A, 0 W Power Supply with DIN-Rail Mounting (RoHS) 4 VDC/.5 A, 60 W Power Supply with DIN-Rail Mounting (RoHS) 5-port / 8-port Unmanaged Industrial 0/00 Switch with Plastic Case (RoHS) 5-port / 8-port Real-time Redundant Ring Switch (RoHS) 0.4" (800 x 600) resistive touch panel monitor with RS-3 or USB interface 7 ICP DAS CO., LTD. Professional Provider of High Quality Industrial Computer Products and Data Acquisition Systems Vol. PAC.4.503