HT2000 Transverter Installation & Operation Manual

Similar documents
Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

5 B&W Rear View System Camera

Modified Sinewave Series. Power Inverter 1000/1500 MW 1210, MW1215. True Sinewave Power Inverter 1000/2000 SW 1210, SW 1220.

Installation/User Manual

Satellite INSTALLATION GUIDE

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

PV Rapid Shutdown device

INSTALLATION INSTRUCTIONS

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

Touch Panel Dimmer MH-P511. Introduction

SA-150, SA-300 Series Pure Sine Wave Inverter User s Manual

INSTALLATION INSTRUCTIONS

Mercury Helios ASSEMBLY MANUAL & USER GUIDE

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

Installation/User Manual

MONOPRICE. ShowPony 12-Watt LED Derby FX Light (RGBW) User's Manual P/N

PACKAGE CONTENTS SPECIFICATIONS

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

InnoMedia ipbx-400. Quick Install Guide.

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

Wa r n i n g-wa r n i n g-wa r n i n g

SAVE THESE INSTRUCTIONS

PV Inverter SUNNY BOY 2000HF-US/2500HF-US/3000HF-US

List of contents. 7-2 CE (ENC EN55022) declaration of conformity CE (LVD EN60950) declaration of conformity. 15 發行章

Super Stack. (Little Stack Wireless + Big Stack)

Manual. Network Expansion Port 2 NEP-2. English. Brands by Navico - Leader in Marine Electronics

OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

User Manual Back-UPS Pro BN 1100/1350/1375/1400/1500 M2 BN 1100/1350/1500 M2-CA

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

USER GUIDE. Element Wireless Smart Plug Model: E1C-NB6

NEW ERA METER. Installation & Operation Guide NE METER

C ookie User Manual BC

Before you get started

Laser Stakes. FarmTek. Laser Positioning System For Barrels and Poles. User s Manual. Sport Timing Specialists

Neets Switching Relay - 2. Installation manual

Installing the Enphase Envoy-S Metered

COMMERCIAL. VAM24-90-(A) Series Installation Instructions

RAINWATCH WIRELESS RECEIVER WIRING

Installing the Enphase IQ Commercial Envoy

FCC Regulatory Information

KS-SB200 BOOM BOX INSTRUCTIONS LVT B [J]

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

4170 POS System Installation Guide

Micro Dimmer MH-P220. *Note: For non-resistive load, a derating output is highly suggested.

USER MANUAL. Model NAME : Anker USB 2.4G Wireless Vertical Mouse MODEL NO. : A VERSION : 0.1 DATE : A User Manual VER: 0.

Unity 100-watt Bridgeable Power Amp

SPECIAL APPLICATION MANUAL PART NUMBER: TNP121UL. Tilt N Plug Jr. Table Top Interconnect Box USER'S GUIDE

WS must be used in a temperature controlled place. It is compliant to ETS Class T


ALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE. Version 1.0 Date: September, Altai Technologies Ltd. All rights reserved

MONOPRICE. Blackbird 4K Pro 1x2 Ultra Slim HDMI Splitter. User's Manual P/N 21612

XBR V4 INSTALLATION AND USER GUIDE

Installation/User Manual

LED FOLDING WORKLIGHT TM

PNP415/417 POP 'N PLUG WITH CUSTOM TABLETOP SURFACE USER'S GUIDE

Innovative Circuit Technology Ltd.

N331 Wireless Mini Optical Mouse User s Guide

HomePro ZRF113. Z-Wave Radio Frequency (RF) Controlled, 120 VAC, Isolated Contact Fixture Module, Series 200, Release 2.2

+Cam Quick Start Guide

Laser Light Projector User s Manual Shenzhen Optlaser Technologies Co., Ltd Model: AL-RG130-RM1

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Now with Picture Memory

888385_01 Install.book Page 1 Wednesday, November 11, :45 PM. SMDR6 Installation Guide

PRODUCT DIAGRAM PACKAGE CONTENTS

Always there to help you. Register your product and get support at SPA1330. Question? Contact Philips.

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

OWC Mercury Pro Optical ASSEMBLY MANUAL & USER GUIDE

Documentation on all Paxton products can be found on our web site -

INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B

Instruction Manual. for. Audio Ape Remotes. 1

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

Charging Pad / Charging Stand

PRO-HC IRRIGATION CONTROLLER

SPK User Manual. 900MHz Wireless Stereo Headphones INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

3190 Series Touch Screen POS Workstation

PACKAGE CONTENTS SPECIFICATIONS PRODUCT DIAGRAM

Lightshow Box with Speaker

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

1. Product Description. 2. Product Overview

WIRELESS BLUETOOTH BOOMBOX

PeopleNet Display.4. User Manual

Contents Attentions... 2 Preparation... 4 Technical Specification... 7

Series Amp Pad Mount Quick Connect Input and Output Power Panels

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Toll Free: Tel: Fax:

AURA SSD FOR MAC PRO. Installation Guide

TABLE OF CONTENTS INTRODUCTION...1 DEVICE SETUP...4 SUPPORT RESOURCES...9

System Design Guide. APsystems YC Photovoltaic 3-Phase Grid-connected Microinverter. APsystems. Version 1.1 3/15

SOHO Access TM Module. User Guide. SAM-SW5U: 5-port 10/100 Ethernet Switch

Model HM-535 Power Supply Installation and Service Instructions

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

ICS Entrance Management Sign Installation Guide. Version 1.0

SAFETY WARNINGS AND GUIDELINES

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

HD40H(X) Performance Series Camera. User Guide

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

True Sinewave Power Inverter 1000W & 2000W 230V , Owner s Manual

User Guide Microsoft Portable Power (DC-21)

The Solution. Multi-Input Module IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

Transcription:

HT2000 Transverter Installation & Operation Manual 1

A message from the team at Heart Transverter S.A. Thanks for your recent purchase of the HT2000 Power inverter in combination with the HTREM Remote Panel. Heart Transverter S.A. takes great pride in manufacturing high quality products specially design to meet the demand of today s busy world. You have taken the first step for achieving a better world, and saving energy; the HT2000 and the HTREM will allow you to manage the energy demand in your house or small appliances, by providing safe connection, UPS support, power factor correction and grid energy injection. If you have any questions about the HT2000 Power Module or HTREM Panel, please contact Heart Transverter at 011-506-2293-3468 (direct). For technical support and additional information about Heart Transverter S.A. products, visit our Web site at www.transverter.com or e-mail us at sales@transverter.com. 4009679 CONFORMS TO UL STD 1741 CERTIFIED TO CSA C22.2 No. 107.1 HEART TRANSVERTER S.A. MODEL: HT2000 2

Table of Contents IMPORTANT SAFETY INSTRUCTIONS 5 FCC Information to the User.7 General Overview..8 Hardware description.....8 DC SIDE.. 9 AC SIDE....10 Getting Started with your HT2000 11 Installation 13 Hardware Installation (mounting).13 AC power installation.13 Brief description of the AC Panel box.14 AC GRID source check.15 AC access panel removal.17 AC wiring check.20 AC access panel placement 20 DC Power Installation 21 Brief description of the DC Inputs 21 DC INPUTS VBA & VBB 21 DC INPUT V50.25 DC source check.25 3

Enclosure Grounding...25 Terminal covers..25 HTREM Module..26 Maintenance Instructions.26 Appendixes.29 Unit ratings.27 Mechanical Drawings...29 Installation Drawing..30 HTREM Mechanical drawing..31 Utility Interactive 32 Stand Alone 32 Utility - interactive with charge control... 32 Stand alone with charge control.32 4

IMPORTANT SAFETY INSTRUCTIONS Save these instructions This manual contains important instructions for Models HT-2000 and HT-2000T that shall be followed during installation and maintenance of the HT-2000 and HT-2000T models. Read all of the instructions and cautions in the manual before operating the HT2000. This guide includes safety operational instructions for the HT2000 Transverter. The following safety symbol conventions are used throughout this guide to indicate potentially dangerous conditions and/or important safety instructions. Please be advised that, for all Transverter installations, qualified personnel are required. Do not attempt to perform this installation on your own. The HT2000 produces voltages and currents capable of causing severe injury or even death. Caution must be taken when installing and operating the HT2000. Ensure that all power (both AC and DC) have been disconnected BEFORE installing, servicing, or removing theht2000transverter. Do not install the HT-2000 on, near or over combustible surfaces. Do not install the HT-2000 on a confined space where there is presence of combustible fumes! Always follow the proper electrical code regulations during installation for proper wiring (i.e. ANSI/NFPA 70 for United States or CEC for Canada) 5

Symbols Caution! Watch! Take notice! High voltage risk High temperature 6

FCC Information to the User This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, you are encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and the receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. Changes or modifications not expressly approved by the party responsible for compliance may void the user s authority to operate the equipment. 7

General Overview The HT2000 power module is a Universal Power Interface that, by using intense amounts of logic, can bi-directionally transfer power between any combinations of its four connections. Each power module has two DC connections and two AC connections. Each DC terminal can connect to anything from 10-50 volts to things like batteries of any chemistry, solar panels, fuel cells, DC wind generators, alternators, etc. The AC connections are for AC loads, the Grid and generators. The HT-2000 power module requires the HTREM to be operated, with the control panel in place, it s very easy to operate the unit. The user can read the power consumption, battery status and also, send information to a personal computer for further analysis. Hardware description The HT-2000 is a 2 kw power interface and UPS system. It serves as a bi-directional interface between any two DC sources or loads between 10 to 50 volts, also an AC interface with an input or output of 110 117 volts in single phase. The HT 2000 supports 2000 watts continuously, and is compatible with 60 Hz AC power. The unit has automatic power factor compensation, pure sine wave output, precisely regulated AC and DC outputs, line conditioning, surge and brownout protection. The unit is divided in several sections for a convenient AC DC installation. 8

DC SIDE DC Connection V50 for multiple units DC Connection for solar panels, VBB. DC Connection for batteries, VBA. Figure 1. DC connection side The unit can allow the user to connect solar panels and batteries on these terminals, also the V50 terminal allows multiple module connections, this terminal works as a power transfer between the units. 9

AC SIDE AC Output of the unit (A) AC Input (from the GRID) (B) DOWN connector (C) UP connector for HTREM (D) Ground lung or chassis ground (E) Figure #2. AC connection side The unit has several connection points on the AC side A. This is the output of the unit, here you can connect your AC loads, it is highly recommended that after the AC output a circuit breaker and a UL 943 listed Ground Fault Circuit Interrupter, GFCI, to be connected in series, this will allow extra security to the people using the system. B. This is the input of the unit, in this section the GRID gets connected, this input must be protected by the means of a circuit breaker. 10

C. This is the DOWN connector, this connector allows to connect multiple units in a daisy chain fashion. The DOWN connector connects to the next unit UP connector. D. This is the UP connector, on this point the HTREM must be connected to allow the operation of the unit. E. This point is the grounding lung, in local installation this point must be connected to ground. Getting Started with your HT2000 HT Identification For future easy troubleshooting, and easy access information, please fill this sheet for future references. HT2000 Identification TAG Date Purchased: Dealer Name: Dealer Address: Dealer phone number: HT-2000 Serial number(s) : HT-2000 HW Revision(s): 11

HTREM Identification TAG HTREM Serial number: HTREM HW revision: HTREM Revision Firmware: Date: Notes: Your 13 digit serial number can be found on the side of the HT-2000 (HT000xxxxxxxx), for the HTREM this can be found on the bottom of the unit (TR000xxxxxxxx). 12

Installation The HT-2000 power module must be installed by a qualified electrician, to avoid electrical wiring mistakes as well as to assure that the HT-2000 will operate in a safe manner. Care should be given in picking a place for the HT-2000 to operate. It is desired to have the power modules reside in a well-ventilated, dry area, away from the weather elements. Ideally, they are to be mounted on the same wall as your existing facility circuit breaker panel and near your DC input sources. Short connections between the DC inputs and the HT-2000 result in power saving. Hardware Installation (mounting) The HT-2000 should be mounted on a vertical wall, this will prevent the entrance of water to the unit or the accidentally intrusion of foreign material inside the unit. Also the HT-2000 has a side ventilator; this section must be free to allow the proper ventilation and cooling of the unit when a heavy load is being used. Also, for the mounting, six 3/8 bolts are needed to secure the device firmly to the mounting surface. (Check appendix drawings for an example on a wall installation) AC power installation Prior to making the electrical installation, verify that all breakers are turned off, all the installation to the HT-2000 must be without voltage. Placing energized cables during the installation of the system is dangerous and can create a voltage arc that can damage the unit and also can cause severe shock to the installer or user. The HT-2000 must be connected to a breaker box on the input of the 13

unit, the following diagram can be followed to have an idea of an example installation of the unit (Figure #3) Brief description of the AC Panel box The HT-2000 has a connection box that allows the wiring of the system to the AC Grid, and to supply AC power to the different loads. AC INPUT (ACIN): This is where the grid connects to the unit, this section supplies energy to the HT-2000 and allows the unit to function with AC power. This input can accept voltages in the range from 105 to 132 volts AC, with a working frequency of 60 Hz. An important feature is that, if the system is installed in a remote location, an AC power generator can be connected to this input. AC Output (ACOUT): This is the output of the unit, on this section the user can get 117 VAC at 60 Hz pure sine wave, this output must be connected to a circuit breaker and then to a GFCI outlet. Note: The GFCI will detect if there is a ground fault. The GFCI provides additional safety for the user. Such electrical GFCI it s NOT provided with the HT-2000 unit. A ground-fault circuit-interrupter must comply with the Standard for Ground-Fault Circuit-Interrupters, UL 943. A tested unit that works with the HT-2000 system is GF20ILA from Hubbell, this GFCI has a capacity of 20 A. Other types of GFCI can be used as long as they are UL 943 Listed and with a capacity to support 20 amps in current. 14

AC GRID source check This verification of voltages must be made on the main breaker panel box. The AC Grid connection to the HT2000 needs to be verified prior to the installation of the HT2000 and TREM units. That is, a quick check of the proper 1 or 2 phase AC wiring from the incoming Grid connection to make sure that single or two phase AC grid connection yields the correct voltage range below: AC Grid Phase 1 Voltage (with respect to the AC Neutral) - 110 o 125 VAC. AC Grid Phase 2 Voltage (with respect to the AC Neutral) - 110 to 125 VAC. AC Two Phase Voltage (with respect from Phase 1 HOT to Phase 2 Hot) - 210 to 250 VAC. If the voltages are not in these ranges, please make an additional verification of the voltage grid. If the system HT-2000 is connected and the voltages are not in the proper range, damage to the unit can occur. 15

Line Neutral AC AC AC Power In (MAIN PANEL) AC power Out (Your breaker box can be bigger with more circuit breakers inside!!!!) 20 SWD 2 0 S W D Green White All the wire connections must be made with AWG #10 GFCI Outlet White AC Connection box on the HT-2000 Figure #3.Circuit breaker connection on the HT-2000 and output breaker box. Note: The input and output breakers must be installed to ensure safety of the equipment and your electrical appliances, such breakers are NOT supplied with the HT-2000 unit. You can use breakers rated at 20 amps, such as the CH120 from Eaton. Other types of circuit breakers can be used as long as they are UL Listed. The circuit breaker for the output AC 16

circuit should be rated at 20 amps and the circuit breaker for the input AC circuit should be rated at 30 amps. AC disconnect and over current protection The input and output circuit breakers provide over current protection and can be used as a manual disconnect by switching the breakers off. AC access panel removal When the AC voltages are checked and within the specified ranges, the AC access panel can be removed to begin the hard wire of the unit, the access panel is located on the front section of the unit and has 2 hex screws. After removing the screws the wires can be fed into the box and connected as properly. Figure #4.AC access panel removal. 17

After the panel is removed, the wiring compartment can be accessed, there are 5 connections, and from TOP to BOTTOM are as follows: (5) AC INPUT LINE (4) AC INPUT NEUTRAL (3) GROUND (2) AC OUTPUT LINE (1) AC OUTPUT NEUTRAL Note: The diagram on figure #3 can be followed for reference, follow the number references. This compartment allows the installer to feed the cables to connect the unit to the grid and to the loads, a Scotchlok PIN Terminals (P/N: MNG10-55P) from 3M can be used to allow a faster easy installation (these pins are not supplied with the HT-2000, and can withstand an amperage equal to the wire AWG 10) To place the terminal on the wire: 1. Strip away the end 3/8 inch of wire insulation. 2. Make the crimp using the a recommended crimp tool, like TH- 440, TH-450, or TR-490 all of them from 3M The figure #5 shows a typical installation and wiring. 18

Figure #5 AC Output and Inputs wired If the terminals are not going to be used, the wire can be feed directly into the connector following these instructions. 1. Loosen the tightening bolts on the connector 2. Strip away3/8 inch of wire insulation 3. Place the wire inside the connector 4. Tighten the screw to secure the cable The unit requires a cable clamp connector knockout conduit fitting to secure the wire in place and to avoid displacement, such cable clamps are not supplied with the unit but must be used to ensure proper installation. The proper size is a ½ diameter conduit clamp connector. 19

WARNING! a. These instructions must be followed and performed while the unit is not energized or connected to batteries, due to risk of electrical shock b. Do not connect the terminals backwards, by doing so, the unit can suffer damage voiding the warranty. All installations must be performed by a qualified technician. AC wiring check After the wires are connected to the system, verify for connection order, verify color code of the cables according to your current electrical code, also, check that the screws that holds the cables in place are tight enough to secure the cable. All this cable connections must be made with a cable size 10 AWG. Also, the grounding terminal in the AC connection box can support two wires 12 AWG. AC access panel placement After the wires are installed, in place and properly secure, follow the back sequence from AC panel removal to finish the AC electrical installation of the unit (figure 4). AC Grounding The HT-2000 has an AC grounding lug located on the external chassis; this ground point must be used to ground the unit locally at the installation place. 20

DC Power Installation The DC power is another important section for the functionality of the HT- 2000. This power can be supplied by batteries (any configuration and chemistry), solar panels, energy cells, or fuel powered electric generators or wind generators. Brief description of the DC Inputs The system has a series of DC connections that allows the HT-2000 receive and feed different types of DC power sources. DC INPUTS VBA & VBB These inputs are coded RED and BLACK, and their purpose is to allow the unit to connect to different power DC sources like batteries, power cells or solar panels. The voltage range for these terminals is between 10 and 50 volts. These connections must be made using at least a 4 AWG wiring. VBA is normally connected to batteries and VBB is normally connected to solar panels. Note: If the power source comes from a bank of batteries configured in 12 V modes, the amount of current that can travel through these wires can go as high as 200 Amps. For this case, a 0 AWG wire must be used and properly secure to the terminal. ADDITIONAL EQUIPMENT THAT MUST BE PROVIDED FOR THE DC INPUTS Additional equipment must be provided to provide the DC disconnect, over current protection and ground fault protection for solar arrays. You can use DC UL rated circuit breakers for the battery connection as well as for the solar panel connection. Many solar combiner boxes include these DC UL listed circuit breakers. You can also use UL listed DC rated fuses with listed fuse blocks. 21

WARNING: This unit is not provided with a GFDI device. This inverter and charge controller must be used with an external GFDI device as required by the Article 690 of the National Electrical Code for the installation location. This system could have the battery negative or the solar negative connected to ground. If there was some damage to the insulation of the positive wire from the solar panels and it was touching a piece of metal of the structure of the building that was grounded then it could act like a small arc welder and possibly cause a fire. If you have the GFDI device installed then it will automatically detect this condition and disconnect the negative wire of the solar panels and protect against this situation. Some examples of high quality GFDI devices you could use from MIDNITE SOLAR www.midnitesolar.com are MNDC-GFP80 Breaker and MNDC-GFP63 Breaker. There are several configurations of batteries that can be used with the HT-2000, here are some examples of interconnection with the unit: 1. The first example it s an interconnection of a single 12 V battery or a bank of 12 batteries to increase the current. 22

Solar Panel 120 A 215 A HT-2000 Solar Panel 12 V 120 A 215 A HT-2000 12 V 12 V 12 V Figure #6. Sample configuration for 12 volts. 23

2. This configuration is for a 24 V battery bank using 12 V batteries in series. Solar Panel 120 A 200 A HT-2000 12 V 12 V 12 V 12 V Figure #7. Sample configuration for 24 V using 12 V batteries. The circuit breakers or fuses should be rated for DC and UL Listed. These are not supplied with the HT-2000 unit. 24

DC INPUT V50 This connection is a special feature of the HT-2000. This output/input allows the unit to distribute power between multiple HT-2000 units connected together. This terminal allows the units to balance the power between each another. It is also used for Telecom devices to get power at a stable 48 V DC. DC source check Prior to connecting the DC power to the unit, verify the voltages that will be connected to the system, both voltages sources must be in the range from 10 50 volts DC. After the voltage is checked, the actual installation can proceed. The system allows the connection of solar panels in terminal VBB, batteries must be connected on terminals VBA. Figure #6 explains in a graphic manner how the system must be connected when these types of power sources are used. Enclosure Grounding After the AC inputs and the DC inputs are in place, installed and verified, the grounding can be installed, the grounding lug it s located on the AC side of the unit, a green wire must be installed to properly ground the chassis. A cable AWG #8 must be used. Terminal covers The terminals covers are for the DC connection side, when the DC power source are properly installed and bolted to the terminals. The covers should be in place to avoid accidental contact with metal objects. The batteries have a capacity to provide enormous currents if they are short circuited. 25

HTREM Module Its highly recommend to install the HTREM in an easy to access location. It is designed to be easily flush mounted on any flat surface such as a wall or desktop, and must be located within 2 meters of the HT-2000 power module. The Standard Ethernet Cable provided must be routed/connected to the HTREM and then four screws anchor the REM module to the desired flush surface. To access advanced features of the HT2000 power module, the HTREM can be connected to a computer via the front/rear panel USB connectors. In this case the HTREM must be within 5 meters (USB2.0 Specification) of the computer you will be using. Note: Avoid excess pressure when installing the screws to secure the HTREM module. If too much torque its applied, the polycarbonate face plate may break causing damage to the unit. Maintenance Instructions Prior to the maintenance activities, verify the safety instructions at the beginning of this manual. Also, if the unit requires servicing, disconnection of all electrical power supplies is a must. The HT-2000 requires very little maintenance, since the internal parts of the unit are not serviceable, the recommended maintenance activities is to verify that there is no dust on top, side and bottom of the unit, also, verify that the exhaust vent it s not blocked or dirty. Additionally, with constant operation and normal vibration, the battery and solar array connectors might get a little loose, once in a while, the tightening must be checked to ensure proper connection. If the terminals connections appear to have concentrations of corrosion, use a brush to clean and to remove these residues. These adjustments must be made with the unit power off from the AC Grid. 26

27

STORAGE TEMPERATURE -20 C to 50 C OPERATING TEMPERATURE -6 C to 43 C DIMENSIONS (H X L X W ) 8.2" X 18.75" X 11.8" BOX SIZE (H X L X W ) 11.0" X 14.5" X 21.0" BOX WEIGHT 33.28 lb (15.1 kg) 4009679 CONFORMS TO UL STD 1741 CERTIFIED TO CSA C22.2 No. 107.1 HEART TRANSVERTER S.A. MODEL: HT2000 28

Appendixes Mechanical Drawings 29

Installation Drawing 30

HTREM Mechanical drawing 31

32