GE Infrastructure Sensing

Similar documents
ECHO Process Instrumentation, Inc. Modbus RS485 Module. Operating Instructions. Version 1.0 June 2010

Interface Definition RISH EM 2340/1320/30/ _Rev. D - 8/2016

MODBUS Message Protocol MODEL FT3

Webinar Organizers. Ryan Shea. Bruce McDuffee. Joe Ryan. Webinar Moderator. Applications Specialist. Product Manager. Precision Digital Corporation

MODBUS MESSAGE PROTOCOL FOR MODEL FT2 THERMAL MASS FLOWMETER & TEMPERATURE TRANSMITTER

MODBUS-IN. Modbus Card. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

1.Eastron SDM530-Modbus Smart Meter Modbus Protocol Implementation V1.1

EM23-DIN COMMUNICATION PROTOCOL. Version 0 Revision 0

Master-Touch and ValuMass. Modbus Communications. INSTRUCTION MANUAL (Rev. 3.1)

NF770 Temperature Compensation Liquid Flow Computer

GE Measurement & Control. PanaFlow Z1G. General-Purpose Gas Flowmeter (1 Channel) User Manual

MultiCube. Modbus Data Tables. August Northern Design (Electronics) Ltd Bradford UK

Appendix to the Operating Instructions RMx621 with ModBus Interface V Connection to ModBus-IDA System

ALTOSONIC V12 Modbus manual. Protocol description & set-up

Real Time Clock with Temperature Sensor and RS485/Modbus Comunications

INTEGRA DL1 DUAL LOAD DIGITAL METER COMMUNICATIONS GUIDE DIGITAL ENERGY METER FOR MULTIPLE LOADS IN AN ELECTRICAL SYSTEM

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

Modbus Module. Data sheet. Communication module for MULTICAL 403 and MULTICAL 603

WM4-96 (Rev. C04 and following) SERIAL COMMUNICATION PROTOCOL

8 data bits, least significant bit sent first 1 bit for even/odd parity (or no parity) 1 stop bit if parity is used; 1 or 2 bits if no parity

RS485 MODBUS Module 6RO

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. Version 3.0

NF760 Batch Controller

Modbus. Interface. Description ISO 9001:2008

Communications guide. Line Distance Protection System * F1* GE Digital Energy. Title page

SKD-005-M Protocol. 2 RS485 General Information 2.1 Half Duplex 2.2 Connecting the Instruments 2.3 A and B terminals 2.

MicroStrain LXRS Wireless Base Station EEPROM Map

A36D/TPSD DNP 3.0 & Modbus SCADA INTERFACE

HRT-710. User s Manual Version HRT-710 User Manual (Version 1.23, Dec/2012) PAGE: 1

Fox Thermal Instruments, Inc.

Modbus Communications October Programming Meters fitted with the Modbus option have two additional stages in the front panel programming menu.

This document assumes the user has a reasonable understanding Modbus, RS485 communications, and Rockwell Software s RSLogix product line.

1.Eastron SDM230Modbus Smart Meter Modbus Protocol Implementation V1.2

AP25-3DO PROTOCOL. Modbus Guide - Issue 1.0 SUBJECT TO CHANGE WITHOUT NOTICE

Serial Connection of HC900 Hybrid Controller to 900CS Control Station

F-3100 FLOW METER NETWORK INTERFACE Installation and Operation Guide

SMARTRAIL X100 Protocol

GE Sensing A November Foundation Fieldbus Communications for the XMT868. Network Connection and Factory Reset

EM300 Series. ET300 Series

Instruction Manual. Save These Instructions. Centrifugal Compressor Control System. Model Xe-145F Modbus. Instruction Manual

GNM3D Series COMMUNICATION PROTOCOL. Version 1 Revision 0

HRM-0800 Instruction Manual

HC900 Hybrid Controller Communications User Guide

Fox Thermal Instruments, Inc.

MX200 SERIES Modbus Card 50P GE Zenith Controls. Operation and Maintenance Manual 50R-2200B 12/00

The Omega product you have just received is of the highest quality available, offering superior performance, reliability and value to the user.

RS485 S-Protocol Communications Supplemental Manual for Brooks GF40/GF80 Series Mass Flow Controllers and Meters

EMDX3 Multifunction meter Cat No ModbusTable LGR EN v1.01.xls

RISH Master 3440i/3440iDL 0.2S

EM100 Series and ET100 Series

Modbus Communications Board

Setup Instructions. This manual is only valid for A12B Chargers equipped with the following: S2A-225C card with software version P225C0630

DRS-100-3P MID Energy Meter Direct Connect, 100A, Three phase Communications Guide

EM24-DIN PFA, PFB & X models

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

Modbus Module. Data sheet. Communication module for MULTICAL 403 and MULTICAL 603

EM21 COMMUNICATION PROTOCOL. Version 1 Revision 0

Automationdirect.com. D i r e c t L o g i c M O D B U S S L A V E F 4 S L V - M B

IFC 100 Supplementary instructions

ABB LVP&S Training AC500 to EMAX Modbus RTU ABB Automation Technologies

AutomationDirect Application Note Connecting an EZ-Touch panel to a Entivity (Think & Do) Studio/Live WinPLC

Number. Number. Error Address. Check (Hi) Points. Points. (Hi)

HC900 Process Controller Communications User Guide

Optidrive VTC Modbus RTU Register Map

BCT SERIES CONTROLLERS (VERSION 3.0) RS-485 COMMUNICATION INSTRUCTION MANUAL MODBUS Protocol Reference Guide

VD SERIES CONTROLLERS (VERSION4.0) RS-485 COMMUNICATION INSTRUCTION MANUAL MODBUS Protocol Reference Guide

Integra Ri3 Digital Meters. Communications Guide

EM24-DIN COMMUNICATION PROTOCOL. Version 3 Revision 1

MS Protocol Converter. User Manual. Firmware version 2.0 ISI. Instrumental Solutions, Inc.

Modbus RTU Serial Communication User Manual

Integra, INT-0220 and INT-0230 (MID) Power Measurement Digital Metering System Communications Guide

Sidewinder Pumps Inc. AC Timer/Controller

Modbus Communications Board

XONIC 100L ULTRASONIC TRANSIT-TIME FLOWMETER. User s Manual FOR LIQUID FLOW. Industrial & Military Instruments. January 2016

RS485 MODBUS Module 8AO

Modbus Protocol For TGP03 / THP03

EMS_ _Measure_MonoPh_R_2P_ModbusTable_LG_EN_v1.01.xlsx

EM210 COMMUNICATION PROTOCOL. Version 3 Revision 1

Modbus user manual PRO1-Mod & PRO380-Mod

Operating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2. Level Indicator L150 and L160

User Manual V1.1. SDM120-Modbus(mV) Single-Phase Multifunction DIN rail Meter

General Specifications. P2-SCM Serial Communications

installation Operation ADDRESS product diagram H8030/8031 INSTALLATION GUIDE

Gateway Ascii Command Protocol

Modbus Protocol For FTS/FTM 3x&8x

Integral Electronics with Local Menu System

Using the MODBUS Protocol with Athena Series C (1ZC, 16C, 18C, and 25C) Controllers

Solumetrix Toroidal Conductivity Sensors

8S RS232/422/485 Combo to USB2.0 Module Box Installation Guide

Modbus RTU Serial Communications User Manual

Intrinsically Safe Temperature Concentrator System

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

Serial Output Option for MAGNA & Intuitive Series: RS232 & RS485 / RS422

HART Field Device Specification: CiDRA SONARtrac

QEL - DEDESCO 5935 Ottawa Street Richmond, Ontario, Canada, K0A 2Z0.

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

CURRENT PROTECTION RELAY SMPR-1

VISY-Command. Technical Documentation. with Modbus Protocol. Edition: Version: 1 Art. no.:

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

Transcription:

GE Infrastructure Sensing 913-299A January 2005 MODBUS Communications for the GC868 Introduction Your Model GC868 hardware and software (GC3E.MBS) have been modified to provide improved MODBUS communications. The MODBUS option card (703-1358) provides an RS485 interface with a host system, while the main circuit board continues to support RS232 communications for use with a PC running PanaView software. To properly set up the instrument, use this addendum along with the standard GC868 flowmeter User s Manual (910-226). This document shows how to install the MODBUS option card and how to program the modified GC868 to access this special feature. When equipped with the optional MODBUS output card, the GC868 flow transmitter can send flow data and diagnostic information to a flow computer (or SCADA) serially, using a Gould-type RTU protocol. In this case, only the MODBUS function command, 3 (read multiple registers), 6 (write multiple registers) is valid. The format for the data exchange is as follows: The send command (initiated by the host flow computer or controller) comes in the form: [time delimiter]<addr><3><first Register MSB> <First Register LSB><Register Count MSB> <Register Count LSB><CRC Low><CRC High>[time delimiter] The response (initiated by the host flow computer or controller) comes in the form: [time delimiter]<addr><3><byte count><data...> <CRC Low><CRC High>[time delimiter]

Introduction (cont.) The format for the returned data types is as follows: Integer (16 bit Integer) <MSB><LSB> 1 Register - 16 bit integer Integer (32 bit IntegerI) <MSB><LSB><LSB><LSB> 2 Register - 32 bit integer Floating Point (FP) <EXP><MAN><MAN><MAN> 2 Registers - 32 bit IEEE floating point number Installing the MODBUS Option Card IMPORTANT: The installation information presented here supersedes the information in the standard GC868 User s Manual. The modified GC868 uses the RS485 standard for MODBUS communications. This standard allows up to 32 nodes (drivers and receivers) on one multidrop network, at distances up to 4,000 ft (1,200 m). To connect the instrument(s) to the host system, GE Infrastructure Sensing recommends using a 24-gauge (24 AWG) twisted-pair cable with a characteristic impedance of 120 ohms and a 120-ohm termination at each end of the communications line. The MODBUS option card must be plugged into either slot 5 or slot 6 of the GC868. On the option card, pin 1 is the [TMT-] inverting or negative connection and pin 2 is the [TMT+] non-inverting or positive connection. To link the GC868 to the control system, connect the two wires of the twisted-pair cable from these terminals to the corresponding terminals at the control system. Note: If two MODBUS option cards are installed in the GC868, only the card in slot 5 is activated. Setting Up MODBUS Communications To set up MODBUS communications, enter the User Program as described in your Programming Manual. Then, refer to the menu map in Figure 1 on page 9 and complete the following steps: Note: Any time the following settings are changed, the GC868 must be rebooted to load the new settings into the option card. PROGRAM Start Press the [ ] key and then the [F3] key to select the COMM submenu. (On a two-channel GC868, pressing the [ ] key PROGRAM status ACTIV SYSTM PIPE I/O and the [F3] key accesses the GLOBL menu. Then press [F4] to select the COMM submenu.) IMPORTANT: The serial port settings of the GC868 must match those of the MODBUS control system. 913-299A 2 of 9

Setting Up MODBUS Communications (cont.) [This baud rate applies only to PROGRAM Comm port BAUD RATE current value appears here the RS232 serial port.] Press the [ ] until the desired RS232 baud rate appears on the option bar and press the appropriate [Fx] function key to select it. 4800 9600 19200 The available RS232 baud rates are 300, 600, 1200, 2400, 4800, 9600, and 19200. [The UART bits setting applies BAUD RATE current value appears here UART bits only to the RS232 serial port.] Press the [ ] until the desired RS232 UART bits setting appears on the option bar and then press the appropriate [Fx] 8,no 8,odd 8even 7,no function key to select it. See Table 1 below for a description of the options available at the above prompt. Table 1: UART Bits Options Option Bar # Data Bits # Stop Bits Parity 8,no 8 0 None 8,odd 8 0 Odd 8even 8 0 Even 7,odd 7 1 Odd 7even 7 1 Even UART bits Network I.D.? current number appears here [The Network ID number is used by the IDM software only.] Enter a Network ID number between 1 and 254 and then press [ENT]. The default ID number is 1. Note: If more than one meter is connected to a network, each meter must have a unique Network I.D. 913-299A 3 of 9

Setting Up MODBUS Communications (cont.) Network I.D.? current number appears here MODBUS BAUD RATE current value appears here 2400 4800 9600 Press the appropriate [Fx] function key to select [2400], [4800], or [9600] for the MODBUS baud rate. MODBUS BAUD RATE current value appears here MODBUS PARITY none odd even Press the appropriate [Fx] function key to select [NONE], [ODD], or [EVEN] for the MODBUS parity setting. MODBUS PARITY MODBUS STOP BITS 1 2 Press the appropriate [Fx] function key to select [1] or [2] for the MODBUS stop bits setting. MODBUS STOP BITS Enter a MODBUS Address number between 1 and 247. Then, press [ENT]. MODBUS Address? current address appears here Press [EXIT] until you return to RUN mode and the screen resumes the display of data measurements. Then reboot the meter to load the new settings into memory. MODBUS Register Map To request specific parameters from the GC868 via the MODBUS, the control system must enter the appropriate register number. Only registers 1 through 90 are available for MODBUS communications, while registers 508 through 512 are used by the GC868 to store the MODBUS parameters. For details, see Table 2 on the next page for a 1-Channel meter or Table 3 on page 6 for a 2-Channel meter. Note: If you request Ch2 or AVE data from a 1-Channel meter, the values will all be zero. 913-299A 4 of 9

Table 2: MODBUS Registers for a 1-Channel GC868 MODBUS DPR Scaling Reg # Hex Addr Description (decimal places) Size in Bytes 1 0 1 Clear Ch1 Totalizers -- 2 (16 bit signed) 2 2 Not Used -- 2 (16 bit signed) 3 4 Velocity 2 4 (2 16-bit int) 5 8 2 Act Volumetric #Q DIGITS 4 (IEEE 32 bit) 7 C 2 Std Volumetric #Q DIGITS 4 (IEEE 32 bit) 9 10 3 Fwd Totals #T DIGITS 4 (2 16 bit int) 11 14 3 Rev Totals #T DIGITS 4 (2 16 bit int) 13 18 #Tot Digits 0 2 14 1A 2 Mass Flow #M DIGITS 4 (IEEE 32 bit) 16 1E 4 Fwd Mass Totals #MT DIGITS 4 (2 16-bit int) 18 22 4 Rev Mass Totals #MT DIGITS 4 (2 16-bit int) 20 26 #Mass Tot Digits 0 2 21 28 Timer 2 4 (2 16-bit int) 23 2C Error Code 0 2 24 2E Sound Speed 3 4 (2 16-bit int) 26 32 Density 4 4 (2 16-bit int) 28 36 Signal Strength Upstream 1 4 (2 16-bit int) 30 3A Signal Strength Downstream 1 4 (2 16-bit int) 32 3E Temperature 2 4 (2 16-bit int) 34 42 Pressure 3 4 (2 16-bit int) 36 46 Signal Quality Up -- 4 (IEEE 32 bit) 38 4A Signal Quality Down -- 4 (IEEE 32 bit) 40 4E Amp Discriminator Up -- 4 (IEEE 32 bit) 42 52 Amp Discriminator Down -- 4 (IEEE 32 bit) 44 56 SNR Up -- 4 (IEEE 32 bit) 46 5A SNR Down -- 4 (IEEE 32 bit) 508 3F6 6 MODBUS baud rate 0 2 509 3F8 7 MODBUS parity 0 2 510 3FA 8 MODBUS stop bits 0 2 511 3FC MODBUS meter addr 0 2 512 3FE RESERVED --- --- 913-299A 5 of 9

Table 3: MODBUS Registers for a 2-Channel GC868 MODBUS DPR Scaling Reg # Hex Addr Description (decimal places) Size in Bytes 1 0 1 Clear Ch1 Totalizers -- 2 (16 bit signed) 2 2 1 Clear Ch2 Totalizers -- 2 (16 bit signed) 3 4 Ch1 Velocity 2 4 (2 16-bit int) 5 8 2 Ch1 Act Volumetric #Q DIGITS 4 (IEEE 32 bit) 7 C 2 Ch1 Std Volumetric #Q DIGITS 4 (IEEE 32 bit) 9 10 3 Ch1 Fwd Totals #T DIGITS 4 (2 16 bit int) 11 14 3 Ch1 Rev Totals #T DIGITS 4 (2 16 bit int) 13 18 Ch1 #Tot Digits 0 2 14 1A 2 Ch1 Mass Flow #M DIGITS 4 (IEEE 32 bit) 16 1E 4 Ch1 Fwd Mass Totals #MT DIGITS 4 (2 16-bit int) 18 22 4 Ch1 Rev Mass Totals #MT DIGITS 4 (2 16-bit int) 20 26 Ch1 #Mass Tot Digits 0 2 21 28 Ch1 Timer 2 4 (2 16-bit int) 23 2C Ch1 Error Code 0 2 24 2E Ch1 Sound Speed 3 4 (2 16-bit int) 26 32 Ch1 Density 4 4 (2 16-bit int) 28 36 Ch1 Sig Strength Upstream 1 4 (2 16-bit int) 30 3A Ch1 Sig Strength Downstream 1 4 (2 16-bit int) 32 3E Ch1 Temperature 2 4 (2 16-bit int) 34 42 Ch1 Pressure 3 4 (2 16-bit int) 36 46 Ch2 Velocity 2 4 (2 16-bit int) 38 4A Ch2 Act Volumetric #Q DIGITS 4 (IEEE 32 bit) 40 4E Ch2 Std Volumetric #Q DIGITS 4 (IEEE 32 bit) 42 52 Ch2 Fwd Totals #T DIGITS 4 (2 16 bit int) 44 56 Ch2 Rev Totals #T DIGITS 4 (2 16 bit int) 46 5A Ch2 #Tot Digits 0 2 47 5C Ch2 Mass Flow #M DIGITS 4 (IEEE 32 bit) 49 60 Ch2 Fwd Mass Totals #MT DIGITS 4 (2 16-bit int) 51 64 Ch2 Rev Mass Totals #MT DIGITS 4 (2 16-bit int) 53 68 Ch2 #Mass Tot Digits 0 2 54 6A Ch2 Timer 2 4 (2 16-bit int) 56 6E Ch2 Error Code 0 2 57 70 Ch2 Sound Speed 3 4 (2 16-bit int) 59 74 Ch2 Density 4 4 (2 16-bit int) 61 78 Ch2 Sig Strength Upstream 1 4 (2 16-bit int) 913-299A 6 of 9

Table 3: MODBUS Registers for a 2-Channel GC868 (Continued) MODBUS Reg # DPR Hex Addr Description Scaling (decimal places) Size in Bytes 63 7C Ch2 Sig Strength Downstream 1 4 (2 16-bit int) 65 80 Ch2 Temperature 2 4 (2 16-bit int) 67 84 Ch2 Pressure 3 4 (2 16-bit int) 69 88 Avg Velocity 2 4 (2 16-bit int) 71 8C Avg Act Volumetric #Q DIGITS 4 (IEEE 32 bit) 73 90 Avg Std Volumetric #Q DIGITS 4 (IEEE 32 bit) 75 94 Avg Fwd Totals #T DIGITS 4 (2 16 bit int) 77 98 Avg Rev Totals #T DIGITS 4 (2 16 bit int) 79 9C Avg #Tot Digits 0 2 80 9E Avg Mass Flow #M DIGITS 4 (IEEE 32 bit) 82 A2 Avg Fwd Mass Totals #MT DIGITS 4 (2 16-bit int) 84 A6 Avg Rev Mass Totals #MT DIGITS 4 (2 16-bit int) 86 AA Avg #Mass Tot Digits 0 2 87 AC Avg Timer 2 4 (2 16-bit int) 89 B0 5 Avg Error Code 0 2 90 B2 Avg Sound Speed 3 4 (2 16-bit int) 92 B6 CH1 Signal Quality Up -- 4 (IEEE 32 bit) 94 BA CH1 Signal Quality Down -- 4 (IEEE 32 bit) 96 BE CH1 Amp Discriminator Up -- 4 (IEEE 32 bit) 98 C2 CH1 Amp Discriminator Down -- 4 (IEEE 32 bit) 100 C6 CH1 SNR Up -- 4 (IEEE 32 bit) 102 CA CH1 SNR Down -- 4 (IEEE 32 bit) 104 CE CH2 Signal Quality Up -- 4 (IEEE 32 bit) 106 D2 CH2 Signal Quality Down -- 4 (IEEE 32 bit) 108 D6 CH2 Amp Discriminator Up -- 4 (IEEE 32 bit) 110 DA CH2 Amp Discriminator Down -- 4 (IEEE 32 bit) 112 DE CH2 SNR Up -- 4 (IEEE 32 bit) 114 E2 CH2 SNR Down -- 4 (IEEE 32 bit) 508 3F6 6 MODBUS baud rate 0 2 509 3F8 7 MODBUS parity 0 2 510 3FA 8 MODBUS stop bits 0 2 511 3FC MODBUS meter addr 0 2 512 3FE RESERVED --- --- 913-299A 7 of 9

Notes: 1. Clear Totalizers: flag from the 8051 to clear either the Channel 1 or Channel 2 totalizers. 2. Values in these registers are floating point numbers and require no scaling. The number of decimal digits is set in meter programming. 3. Require scaling by value in register 13. 4. Require scaling by value in register 20. 5. AVG Error Code: 0=Both Ch1 and Ch2 are in error. 1=Ch1 only is in error 2=Ch2 only is in error 3=Both channels are error free 6. MODBUS baud rate: 5 = 2400, 6 = 4800, 7 = 9600 7. MODBUS parity: 0 = none, 1 = odd, 2 = even 8. MODBUS stop bits: 1 = 1 stop bit, 2 = 2 stop bits 913-299A 8 of 9

1-Ch Meter 2-Ch Meter GLOBL COMM Baud Rate (RS232) F3 F4 300 600 1200 2400 4800 9600 F3 19200 UART Bits (RS232) 8,no 8,odd F3 8even F4 7,odd 7even Network I.D.? MODBUS Baud Rate 2400 4800 F3 9600 MODBUS Parity NONE ODD F3 EVEN MODBUS Stop Bits 1 2 MODBUS Address NOTE: Plain text represents prompt area messages and boxed text represents option bar choices. Fx represent function keys to select option bar choices. Figure 1: MODBUS Menu Map 913-299A 9 of 9