UNIQUE DESIGN FEATURES

Similar documents
IS-DM220/IR/HB IS-DM220

WaterGlowTM. LL1020 Submersible Landscape Light Owners Manual. Thermal Overload Protection, Gasket, & Potting Eliminate Leaks.

GLOBRITE COLOR CHANGING UNDERWATER LED LIGHT FOR POOL AND SPA

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures)

Installation Notes TII Model 341 Protector

2M IR Mini Dome Quick Installation Guide

Arecont Vision MegaDome 2 Installation Manual (DN Models Only)

LIGHTING OVERVIEW. 170 Adagio PRO LED Lights and Controls. 174 Underwater Lights. 177 LED Replacement Bulbs, 300 W Replacement Bulbs

FortiCam FD40 Mounting Guide

Mounting on the Ceiling Using Flush Mount (Face Down)

FDS / FDS-R / FDS-PS

MC-1 OPERATION MANUAL MINI CAMERA JW FISHERS MFG INC 1953 COUNTY ST. E. TAUNTON, MA USA

BPL SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

Nano Liner Allegro AC XB RGB / DW INSTALLATION GUIDE V1.2

LUMOTAST 25 selector switch 1-28 LUMOTAST 25 selector switch, ring nut fixing LUMOTAST 25 keylock switch 1-30 LUMOTAST 25 keylock switch 1-31

Electrical Specifications

PIPE & WALL INSPECTION SYSTEMS ASSEMBLY AND OPERATING INSTRUCTION

Nominal. Mounting. Length foot foot RUN Nominal Lengths* Suspension Bracket 1 Studs (Factory installed) Rotating Crossbar

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

SignBOX II. Retrofit Guide for (X)WS201 and (X)WD201

Outdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03

A note about our online installation instructions:

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

ZC-OH5 TAMPER-RESISTANT INDOOR/OUTDOOR HOUSING INSTRUCTION MANUAL FOR USE WITH GANZ ZC-D5000 SERIES MINIDOME CAMERAS

OSRAM ReliaSys TM D15 LED Retrofit Kit INSTALLATION GUIDE

KEPLERO MINI HE Efficiency & Interchangeability

westelettric ELECTRICAL RUBBER BOXES

IGLOO IGLOO EASY INSTRUCTION MANUAL

Ravenna TM. Fixture Options: Ordered Separately from Fixture See page 2. Mounting Options: Ordered Separately from Fixture See pages 3-5

Additional Help For additional installation instructions and videos, please visit our website at What s Included

nls Product List 1st February, 2014 Tel: Fax: Coombes Drive, Penrith, NSW, 2750 Australia

INSTALLATION INSTRUCTIONS

LANCER / LANCER EVOLUTION (2008 ) REAR VIEW CAMERA MZ380462EX INSTALLATION AND HANDLING INSTRUCTIONS

Installing the Camera

WINSTA. Full Line Catalog 2008/2009

Standalone Night Sensor

TOKISTAR LIGHTING INSTRUCTION MANUAL. Advantage XF Series

Arecont Vision MegaDome Installation Manual

Terragraph Installation Guide. March 8, 2017 Version 0.3

GV-IPCam H.264. Hardware Manual. Vandal Proof IP Dome Target Vandal Proof IP Dome

PEREGRINE SERIES RETROFIT INSTALLATION GUIDE

SAVE THESE INSTRUCTIONS

AUREOL RECESSED BEAMSHAPER OPERATION MANUAL

JAN 16 Rev B

Switches and Indicators 84

WIRED REMOTE INSTALLATION GUIDE

ZAVIO Outdoor IR Mini Dome. Quick Installation Guide

User Manual. Trinocular Stereo Microscope

Wireless Inspection Camera and LCD Display Instruction Manual

Mi50 Inverted Microscope User s Manual. Fein.

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV

Lighting Controls and Connectivity DALI sensors. MSensor G3 SFI 30 PIR 10DPI WH Multi-sensor

Instruction Manual. B1 Series. Copyright 02/02 Motic Microscopes, European Division

Description: Detailed procedure on removing old bushing and installing new Brake Bushing Replacement Kit 10447

High Resolution Indoor Dome Camera

PLEASE NOTE: These instructions are intended to be used by a person with average mechanical and electrical skills.

INSTALLATION INSTRUCTIONS

MacBook Core 2 Duo Display Replacement

Removal and Installation8

Standard Strip Series

IKON PRO SENSORS FOR DECKING KITS Add extra functionality with our new Ikon Pro sensors Range includes PIR Presence or Photocell Twilight Detectors

SUN3 LED REV

WARNING. General Information

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

ASSET LGA1366 Top-side Probe

Arecont Vision MegaDome TM Installation Manual

Outdoor Motorized Dome. Quick Installation Guide 86085A

PHOS 20/40 downlight OWNER'S MANUAL

ASI Systems ML5740A Series

ASI Systems ML5720A Series

Sarix Professional IMP Series 3.75 Indoor Dome. Quick Start Guide IMP121-1IS IMP221-1IS IMP321-1IS IMP521-1IS C2291M-B-EN (12/16)

Ravenna TM. Fixture Options: Ordered Separately from Fixture. See page 2. Mounting Options: Ordered Separately from Fixture.

Plexo IP 55/IP 66. Makes your day, rain or shine PLEXO / WEATHERPROOF PRODUCT GUIDE. For reference only.

60 Watt Portable LED Work Area Light - Waterproof - Aluminum Frame - Adjustable Light Head

Installation Instructions MX LED Wall Wash Remodel

45 Magnified Viewfinder for DSLR and Mirrorless Housings Product Numbers and

Next Gen Sarix Enhanced IME Series Mini Dome Cameras

DIRECT POWER LIGHTING MANUAL

Supplemental guide on Camera Fabrication

Fixture Options: Ordered Separately from Fixture. See pages 2-3. Mounting Options: Ordered Separately from Fixture. See pages 4-6

AION LED WT SERIES. Custom Lengths. Made in the USA IP66* High Efficacy Exterior Rated Linear Fixture System

diode led VALENT X SPECIFICATION SHEET 24VDC OVERVIEW FEATURES & BENEFITS COMPATIBLE CHROMAPATH CHANNELS

KEPLERO ZOOM Flexibility

SERVICE PARTS MANUAL

Halo-5 Microdrive. Users Manual. Microdrive used for manually driving tetrodes for electrophysiology recordings

Chemlock PFA and PP Filter Housings

UNDERCARPET CABLING SYSTEM For Power and Communications

Yashica 635 On-line users manual Posted 4-21-'03

*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition).

A.A.G. Stucchi TRACK LIGHTING SYSTEM

MASTERLINE Ultimate Hybrid High Voltage 4/12 (MLUH HV 4/12) blunt cut at BTS side

-Verify that supply wiring voltage matches power supply voltage by comparing it with power supply label.

Manual No: Revision: D. Mag Retrofit Probe. Installation Guide

Three Phase Residential Solution for Australia, System Design and Installation Guidelines

Next Gen Sarix Enhanced IME Series Mini Dome Cameras

RCL-50B PRODUCT SUPPORT MANUAL. Remote Control Searchlight Master Controller Point Pad. Y Rev. B

STANDALONE NIGHT SENSOR

FOS PAR Innovative 1

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Transcription:

LIGHTING SYSTEM UNIQUE DESIGN FEATURES POWERITE The provides a totally new concept in Underwater Pool/Spa and Aquatic Landscape Lighting Design. Utilizing new technology moulding materials it has been possible to produce a compact light fitting with unique features that are not currently available from any other existing pool or spa lighting product. 3 5 /16" Compact Size Only 3 5 /16" Diameter Encapsulated Cable Terminations Ensures no external cable or water seal deterioration due to heat. Non Leak Water Seal No Polycarbonate that cracks is used in the water seal. Simple Lamp Replacement Flexible Lens Absorbs pressure due to the expanding air when light is operated. Even Light Distribution Created by unique moulded prismatic lens. Long Life Lamp Fitted with 10,000 Hour life 12V Xenon Lamp. Optional Color Change LED Lamp Can provide 7 different color effects. U.S. Master Distributor OEM and Dealer Opportunities Available 3120 E. Medina Rd. Tucson, AZ 85706 Ph. 866-388-3398 Fax 800-234-7894 Email pal2000@horizonparts.net

LIGHTING SYSTEM INTRODUCTION TO THE UNDERWATER LIGHTING SYSTEM POWERITE The is a unique Underwater Pool & Spa Lighting System. A soft evenly distributed light is now possible from the moulded prismatic lens design that provides the with an outstanding illumination eliminating the end shadow effect common with other existing pool lights, all with a 10,000 hour life lamp. The operates from a Safe 12V supply and is UL approved. The has a unique extraction system allowing the light to be simply removed from the pool wall when the lamp has to be replaced as illustrated below. The is set flush on the pool wall enhancing the side light feature and the overall appearance of the light. The lens cover is rotated 1/6 of a turn and the lamp housing is released from the light fitting body. The curled lead allows the lamp to be taken out of the water to the pool coping to replace the lamp. Unique Features Compact Size. 60% Smaller than normal pool lights. Flush Fit to Pool Wall. The other lights protrude off the wall. Even Light Distribution. No other light has a flexible moulded prismatic lens. Side Light Feature. The end shadow effect common in other lights has been eliminated. Long Life Lamp. Fitted with new extra bright 10,000 Hour 12V Xenon lamp. Fully Approved Product. UL Listed E239438. No Earth Bonding Required. Due to fully insulated design. Non Leak Water Seal. No polycarbonate that cracks is used in the water seal. Flexible Lens. Absorbs pressure increase due to the expanding air when light is operated. Encapsulated cable terminations. Ensures no external cable or water seal deterioration due to heat. The also has a range of Clip-On colored lenses. Blue, Green, Red & Orange. Optional Color Change LED Lamp. Can provide 7 different color effects. U.S. Master Distributor

LIGHTING SYSTEM CONCRETE/FIBERGLASS LIGHT POWERITE PAL- 2000RU 50w, 12v, Underwater Light with 10,000 hour Xenon lamp, complete assembly with 79 ft cord, locking nut, and seal. Must use UL listed outdoor transformer. Light includes blue, green, and clear lenses. Horizon # Manf. # 56-330-1000 39-2RU PAL- 2000RCUK Concrete conversion kit adapts standard PAL- 2000 light for use with concrete pool wall fitting. Horizon # Manf. # 57-330-1050 39-2RCUK PAL- 2000RCAS Concrete pool wall fitting, when used with the concrete conversion kit, allows for the installation of a standard PAL- 2000 underwater light into a concrete installation. Horizon # Manf. # 57-330-1055 39-2RCAS PAL- 2000 Light Lens Accessories Horizon # Description Manf. # 57-330-1060 Blue snap on lens 39-2CB 57-330-1062 Green snap on lens 39--2CG 57-330-1064 Red snap on lens 39-2CR 57-330-1066 Orange snap on lens 39-2CO 57-330-1068 Clear snap on lens 39-2CC 57-330-1075 Colored lens set 39-2CS 12v, 50W Xenon Replacement Bulb Kit Super bright, 10,000 hour replacement bulb, shipped with new PAL 2000 light body O-ring. Horizon # Manf. # 57-330-1080 39-2DL50 LAC MR-16 Digital Color Array Lamp 21 LED lights with 7 different color displays all rotating smoothly from one color to the next. Compatible with standard MR-16 Halogen bases, optional MR-16/GE912 adaptor available for use in standard spa light applications. Horizon # Description Manf. # 57-330-1100 LAC MR-16 color array 39-LACU 57-330-1120 MR-16/GE912 adapter 39-LAA U.S. Master Distributor

Assembly Information for RU light in Fiberglass Pools & Spas Assembly Details Important Information 1) Ensure that the electrical system for your pool conforms with all the requirements of the National Electrical Code (NEC) and all relevant local codes and ordinances. 2) This 12V Underwater Light must be installed in accordance with the National Electrical Code by a Certified Electrician or a Qualified Pool Technician. NOTE: No Bonding Terminal is required on the forming shell since the fixture is an all plastic construction and complies with NEC article 680 Requirements. 3) This Underwater light is designed for use with an Approved Low Voltage Transformer operating between 12-15V. DO NOT CONNECT THIS 12V LIGHT DIRECT TO A 120V CIRCUIT. 4) Do not operate this Underwater Light for more than 30 Seconds unless it is totally submerged underwater. 5) Fit your RU Underwater Light/s as outlined in the following detailed installation instructions. Installation Instructions for RU Retractable Fitting in Fiberglass Pools/Spas Step 1. Locate the position for mounting the RU fitting at the center of one end of the pool or the center of both ends if required. If the pool is an irregular shape the fitting should be located in a position to obtain the best light spread in the pool. The fitting should be placed 12" below the water level or 18" below the top of the pool coping to provide the best illumination of the water and enable the retractable part of the fitting to be taken out of the pool if the lamp in the RU has to be replaced. Step 2. Drill a 2 3/8" mounting hole (2 3/8" to 2 1/2") at the selected location. After the hole is cut out, clean the area around the hole to remove rough spots and dust. Step 3. Fit the RU fitting in the hole ensuring the rubber seal is fitted at the between the back of fitting and the pool/spa wall as shown in the diagram. Place a bead of silicon between the nut and the wall then tighten up the nut firmly. If desired the rubber seal can also be replaced by silicon. Step 4. Connect the wire to an approved Low Voltage Transformer in accordance with the National Electrical Code (NEC). The conduit adaptor should be glued with solvent cement to the gland nut and 1/2" PVC conduit can be glued to the inside of the conduit adaptor. Alternatively a standard 3/4" conduit adaptor can be glued to the outside to fit 3/4" PVC conduit to the light. 18" 12" Place a bead of silicon between wall & nut during installation RU 1/2" or 3/4" Adaptor 1/2" PVC Alternative Cover Lens Locking screw Rubber seal Locking nut Pool or Spa wall Standard 3/4" Adaptor 3/4" PVC

Assembly Information for RU light in Fiberglass Pools & Spas Lamp Replacement Instructions for RU Retractable Fitting Step 1. Unscrew the Cover Lens Locking Screw (shown in figure 2) until the lens cover can be twisted in an anti-clockwise direction to retract the lamp fitting from the housing (shown in figure 1). Step 2. Remove the clip-on lens cover with the aid of a screwdriver as shown in figure 3. Step 3. Unscrew the (6) six lens screws to unclip the lamp from the lamp socket as shown on the Assembly drawing. Step 4. Replace the Lamp. Note: To ensure reliable operation of your it is essential to use a genuine RU Lamp/Seal Replacement kit part no. 39-2DL50 or FNV/CG 50 watt Xenon Lamp with UV Cover Glass. (No other) When the Lamp is replaced it is essential to maintain the water tight seal that the "O" ring be also replaced, the "O" ring seal is supplied with the Lamp/Seal replacement kit. (39-2DL50) Step 5. When reassembling the RU fitting ensure the "O" ring is sitting correctly and replace the (6) lens screws and ensure the screws are not overtightened. Fit the lens cover. Step 6. Feed the wire back into the body and twist the fitting in a clockwise direction to lock into position. Extraction System Details U Lamp Fitting Lamp Holder Xenon Lamp "O" Ring Seal Lens Lens Clamp Ring (6) six Screws Lens Cover Figure 1 Cover Lens Locking Screw 1/2" PVC Dimensional Details 3 1/2" 7/8" 5/6" 7" (min) 5 1/2" No Niche required due to unique cassette construction. 2 5/16" φ 2 3/8" - 2 1/2" Mounting Hole Front View Figure 2 OF R IS K E LE CTR IC S HOCK Housing S UB ME R S E B E FOR E RU 1/2" or 3/4" Adaptor Side View of Lamp Fitting Figure 3 CAUTION L IGHTING Lens Locking Screw Clip off with Screwdriver

Assembly Information for RCU light in Concrete Pools & Spas Important Information 1) Ensure that the electrical system for your pool conforms with all the requirements of the National Electrical Code (NEC) and all relevant local codes and ordinances. 2) This 12V Underwater Light must be installed in accordance with the National Electrical Code by a Certified Electrician or a Qualified Pool Technician. NOTE: No Bonding Terminal is required on the forming shell since the fixture is an all plastic construction and complies with NEC article 680 Requirements. 3) This Underwater light is designed for use with an Approved Low Voltage Transformer operating between 12-15V. DO NOT CONNECT THIS 12V LIGHT DIRECT TO A 120V CIRCUIT. 4) Do not operate this Underwater Light for more than 30 Seconds unless it is totally submerged underwater. 5) Fit your RU Underwater Light/s as outlined in the following detailed installation instructions. Installation Instructions for RCU Retractable Fitting in Concrete Pools/Spas Step 1. Locate the position for mounting the RCAS fitting at the center of one end of the pool or at the center of both ends if required. If the pool is an irregular shape the fitting should be located in a position to obtain the best light spread in the pool. The fitting should be placed 12" below the water level or 18" below the top of the pool coupling to provide the best illumination of the water and enable the retractable part of the fitting to be taken out of the pool if the lamp in the RU has to be replaced. Step 2. Fit the RCAS wall housing into the selected position in the steel wire t secure it into position with the mounting lugs around the housing. Ensure the RCAS wall housing is level, square and flush with pool concrete wall. Glue 1/2" conduit into position and fit the draw ware as shown in Diagram 1 and 2. Step 3. After the concrete wall is set, trim the pipe down as shown below. Step 4. The standard RU light assembly now has the RCU adaptor glued with PVC glue o to the Light assembly as shown in Diagram 3 and the standard clear lens cover fitted on the RU light assembly replaced by the protective cover supplied in the concrete pool conversion kit. (39-RCUK) Step 5. Before the pool finish is applied the RU with the RCU adaptor fitted should be glued into the RCAS wall housing using PVC glue to seal and locate the fitting into position, as shown in Diagram 5. Step 6. WIth the fitting in position in the Concrete Wall the Pool Finish can be applied to the front face of the fitting as shown on the assembly drawing. Note: The disposable Lens Cover fitted to the RU will protect the fitting while the finish is being applied. The protective lens cover is replaced by the normal lens cover supplied with the RU when the pool is ready to be filled with water. Diagram 1 & 2 Front View Allow 18" Max. to top of coping Front of Concrete Point Steel Wire Cap 4 x construction lines in side of moulding indicates front of concrete point Side View Pool Wall Draw Wire 1/2" Electrical Alternative 3/4" Electrical 3/4" Electrical Adaptor Intermediate Bar Ensure the RCAS assembly is square, level and flush with pool concrete wall. RCA Housing Allow at least 7" to fit light body

Assembly Information for RCU light in Concrete Pools & Spas Diagram 3 At least 7" Diagram 4 Cut pipe flush Construction Lines Draw wire Glue RCU adaptor to light with PVC glue Tie light to draw wire Pull using draw wire Diagram 5 Glue RCU into RCAS housing with PVC glue Concrete wall Pull using draw wire Final Assembly 18" Coping Concrete wall RC housing 1/2" Electrical 12" Protective Lens Cover RU Concrete Wall Lens Cover Pool Finish Steel Rod Pool or Spa Concrete wall RCA Wall Housing Lamp Replacement Instructions for RCU Retractable Fitting Step 1. Unscrew the Cover Lens Locking Screw until the lens cover can be twisted in an anti-clockwise direction to retract the lamp fitting fro the housing (shown in figure1). Step 2. Remove the clip-on lens cover with the aid of a screwdriver. Step 3. Unscrew the (6) six lens screws to unclip the lamp from the lamp socket as shown on the Assembly drawing. Step 4. Replace the Lamp. Note: To ensure reliable operation of your it is essential to use a genuine PAL- 2000RU Lamp/Seal Replacement kit part no. 39-2DL50 or FNV/CG 50 watt Xeon Lamp with UV Cover Glass. (No other) When the Lamp is replaced it is essential to maintain the water tight seal that the "O" ring be also replaced, the "O" ring seal is supplied with the Lamp/Seal replacement kit. (39-2DL50) Step 5. When reassembling the RU fitting ensure the "O" ring is sitting correctly and replace the (6) lens screws and ensure the screws are not overtightened. Fit the lens cover. Step 6. Feed the wire back into the body and twist the fitting in a clockwise direction to lock into position. Extraction System Details U Fitting Lamp Holder Lamp "O" Ring Seal Lens Lens Ring (6) six Screws Lens Cover OF R IS K E LE CTR IC S HOCK S UB ME R S E B E FOR E CAUTION L IGHTING Cover Lens Locking Screw Lens Locking Screw Clip off with Screwdriver Housing

LIGHTING SYSTEM NEW LA MR16 LED ARRAY PRODUCT RELEASE POWERITE New Product Release! To complement the line of Underwater and Landscaping Lighting Products, the LACU Digital Color Change Array has been developed utilizing New Ultra-Bright LED Technology and is available at an attractive price point. With standard MR-16 dimensions and no external controller required, the outstanding new LACU Color Array can be used in any existing Underwater Pool or Landscaping Light or can be used to replace any standard 12V MR-16 Lamp. In addition, the use of a simple adapter allows the LACU Color Array to be retrofitted into applications using the GE-912 bulb! The LACU Digital Color Change LED Array automatically incorporates 7 different color effects and, with it s Color Unison feature, enables an unlimited number of lights to be synchronized to change color in unison. FEATURES Ultra-Bright LED Technology Long Life up to 100,000 hours Low Power, Low Heat Compatibility with existing MR-16 lamps Retrofits into GE-912 Base with adapter No external controller required Provides the only simple low cost conversion to color change in MR-16 type lights Can be used in fittings in and out of water Attractive price points U.S. Master Distributor OEM and Dealer Opportunities Available 3120 E. Medina Rd. Tucson, AZ 85706 Ph. 866-388-3398 Fax 800-234-7894 Email pal2000@horizonparts.net