Centra Workbench (V3.12 onwards)

Similar documents
Jonas Activity Management Technical Deployment Guide

Administrator s Guide

Pension System/Windows. Installation Guide

3M Occupational Health and Environmental Safety 3M E-A-Rfit Validation System. Version 4.4 Software Installation Guide (Full) 1 P age

KYOCERA Net Admin Installation Guide

InventoryControl Quick Start Guide

Version 4.1 Software Installation Guide (Full)

HR-Lite Database & Web Service Setup Guide

1 Overview. 2 Installation. exacqvision-entrapass Installation Guide.

How to install the software of ZNS8022

LiNC-NXG for Windows 8 Professional, Windows 7 Professional, Vista Business Edition and XP Professional

Fleet Manager 2002 Professional Network Configuration Guide

Acronis Backup & Recovery 11 Beta Advanced Editions

LiveNX Upgrade Guide from v5.1.2 to v Windows

PAL Installation Instructions

Elmhurst Design SAP 2012 Software Installation Guide VERSION 1.2 (January 2016)

License Server

Installation Reference

PerTrac Analytical Platform. SQL Version Setup Guide

STATISTICA VERSION 10 STATISTICA MONITORING AND ALERTING SERVER (MAS) INSTALLATION INSTRUCTIONS

ZAVANTA Standalone Installation

Print Audit 6. Print Audit 6 Documentation Apr :07. Version: Date:

Migrating ABECAS Insight

OFFSIDER. Standalone Installation Guide. Updated: August 2018

TPP Server INSTALLATION AND SET-UP

WA1976 WebSphere Application Server 7.0 Administration Fundamentals. Classroom Setup Guide. Web Age Solutions Inc.

3M Molecular Detection System Software Upgrade/Installation Instructions

UOB Offline Data Input Software (ODIS)

This is a GENERAL Servant Keeper Network Installation help sheet. If you need further assistance, please contact your network administrator.

Desktop Deployment Guide

Pension System/Windows. Installation Guide

JPRO Fleet Service Portal User s Guide

Document Management Upgrade Guide

Connect Install Guide

UC for Enterprise (UCE) NEC Centralized Authentication Service (NEC CAS)

T E KLYNX CENTRAL I N S T A L L A T I O N G U I D E

Elmhurst Design SAP 2009 Software Installation Guide

Copyright Autodesk, Inc.

WA2031 WebSphere Application Server 8.0 Administration on Windows. Classroom Setup Guide. Web Age Solutions Inc.

Xactimate 25 Demo Request

CorpSystem Workpaper Manager Installation Guide

1. ECI Hosted Clients Installing Release 6.3 for the First Time (ECI Hosted) Upgrading to Release 6.3SP2 (ECI Hosted)

APPENDIX B: INSTALLATION AND SETUP

AnySite. Australia. Install Guide. AnySite v9.1 Install Guide

Deployment Guide Installing WhatsUp Gold Distributed Edition to Central and Remote Sites

C-MagSys and Q-MagSys Components Installation Guide (20 January 2010) C-MagSys and Q-MagSys Components Overview at Clinic

Version 12.0 Component Installation and Configuration. January 31, 2007

Avigilon Control Center Virtual Matrix User Guide

Version 6.3 Upgrade Guide

Valley Library Consortium

Microsoft Windows Servers 2012 & 2016 Families

Installation Guide. Version 2600

Installing Authoring Manager

U3 Encryption Utility User Guide

WEBSEWSS SINGLE SERVER INSTALLATION INSTRUCTIONS

EasyLobby Database Setup EasyLobby Family of Products Version 10.0

Avigilon Control Center Server User Guide

UNGASS DATA ENTRY SOFTWARE: GLOBAL REPORTING 2008 SETUP NOTES

LABEL ARCHIVE Administrator s Guide

Image Backup and Recovery Procedures For Windows 7

DISCON Specialists Metabuilder Install Guide

TEKLYNX BACKTRACK I N S T A L L A T I O N G U I D E

School-to-Home Connection Instructions

Restoring data from a backup

UNICORN Administration and Technical Manual

SEMS SOFTWARE SUITE INSTALLATION WHERE TO DOWNLOAD THE INSTALLERS

Controlsoft Identity and Access Management Software Controlsoft Identity Access Client Software

Installing Switched-On Schoolhouse 2007

EventMaster PLUS! Version 4 Installation and Upgrade Guide. Enterprise Deployment Microsoft SQL Server

MapMarker Plus Desktop Installation Guide

Avigilon Control Center Server User Guide

x10data Application Platform v7.1 Installation Guide

User Guide MapRoad 2.3 Install Guide Windows 7

ProSightPC Version 2.0 SP1

exacqvision-entrapass (W10) Installation Guide

Accountants. Enterprise. Installation Guide. Administration Centre. Version 3.0

IT Essentials v6.0 Windows 10 Software Labs

Upgrading from Call Center Reporting to Reporting for Call Center

Junxure Code Upgrade Instructions

Saral TDSPlus. Installation & Registration. User Manual

ISM Provision Installation Guide

Lasso Continuous Data Protection Lasso CDP Client Guide August 2005, Version Lasso CDP Client Guide Page 1 of All Rights Reserved.

NTP Software File Auditor for Windows Edition

HP Video Over Ethernet. User Guide

Installation and Upgrade Guide Zend Studio 7.0

Practice and Review Activities Software

Important notice regarding accounts used for installation and configuration

DOCUMENT HISTORY REV. NO. CHANGES DATE. 000 New Document 30 Mar Document Revision:

EntraPass (W10) Installation Guide Kantech-OnBoard systems

1) Installing Bluetooth software for Windows (A) Place installation CD into PC and setup should launch automatically.

Installation Guide for Pulse on Windows Server 2012

Upgrading Software and Firmware

Copyright SolarWinds. All rights reserved worldwide. No part of this document may be reproduced by any means nor modified, decompiled,

Agilent SureCall 3.5. Installation Guide. Agilent Technologies. For Research Use Only. Not for use in diagnostic procedures.

Viewer Software. Installation Guide

IM10- Elmhurst SAP2005 Design Software Installation Instructions

Lab: Deploying Operating System Images Using SMS 2003

WA1561 WebSphere Application Server v6.1 Administration. Classroom Setup Guide. Web Age Solutions Inc. Copyright Web Age Solutions Inc.

Mobile Inventory Tracking & Sales Management Software. Installation Procedure

EvaluNet XT v1.2. Setup Guide

Transcription:

Workbench Installation Guide Centra Workbench (V3.12 onwards) Create and Customize User Interfaces for Router Control snellgroup.com

Introduction Description This guide describes the system requirements and procedures for installing Centra Workbench. Fig 1. shows two typical installation scenarios: A standalone installation where everything resides on a single PC. A distributed installation where the database and SQL server are installed on the server PC, and client PCs have individual components that connect through the network to the database. Standalone PC Database SQL Server Workbench Management Studio Server Database SQL Server Network PC1 PC2 PC3 Workbench Management LiveRunner Studio* Client * Management Studio may be installed on any, or several, PCs on the network. Fig 1. Installation on a single PC or on a Network Issue 1 Rev 2 Page 2 2012 Snell Limited

System Requirements The software can run in any resolution. We recommend that you use a resolution of 1920 x 1024 for Run mode, and a minimum of 1024 x 768 for Workbench (1280 x 1024 is ideal). 27BRecommended specification: A PC running MS Windows XP SP2 or higher (Vista, Windows 7 32-bit or 64-bit) A multi-core processor (>1. 6 Ghz). 2 GB RAM. Support for DirectX 9 graphics with a WDDM driver, 128 MB of graphics memory (minimum), Pixel Shader 2.0 and 32 bits per pixel. System performance is dependent on PC s available resources. The PC should be as clean as possible from other running processes. Note: For Windows 7, the user must have local Administration rights for installing and running Centra Workbench. Minimum Installation Requirements For a distributed installation, the minimum installation requirement consists of the mandatory items and the LiveRunner component. For a standalone installation, the minimum installation consists of the mandatory items and the SQL Server Express component. Issue 1 Rev 2 Page 3 2012 Snell Limited

Installing Centra Workbench Installation Note: During the installation process additional screens may display, due to the nature of different operating systems and initial PC setups. Refer to the Troubleshooting section to see what actions to take in the event of these screens displaying. 1. Insert the Centra Workbench DVD into the CD-ROM drive. The installation application starts automatically. If it does not, browse to the installation CD-ROM and click WorkbenchInstaller.exe. 2. The end user license agreement (EULA) displays. Fig 2. License Agreement 3. Read through the license, and click I Agree. 4. The Choose Components screen displays. Fig 3. Choose Components Issue 1 Rev 2 Page 4 2012 Snell Limited

5. Select the Centra Workbench components that you want to install and clear those that you do not want to install. Table 1. lists the available options. Note: Greyed-out ( ) items are mandatory. The installer checks to see whether the item is already present, and only installs it if it is not found. Component Description Required for Client Required for Server MSI 4.5 Microsoft Windows Installer 4.5 NET Framework 3. 5 SP1 NET Framework 3 5 SP1 NET Framework 4 NET Framework 4 Visual C++ 2010 Visual C++ Redistributable Windows Powershell Microsoft's task automation framework that integrates with the.net Framework SQL DB Tool Used to backup/restore/create Databases. Can be used in place of the SQL Management Studio Core Files Core Installation files Workbench The Centra design and configuration files Live Runner The Centra live control and monitoring Rules Server The Centra rules server application Logging Tools Tools and utilities for viewing and gathering log messages Example Resources Example screen files and database Controllers Windows and embedded controller executable files Pbak Deploy Tool Used to upgrade software on embedded controllers Documentation Manual and Getting Started guide in PDF format Table 1. Installation Components Note: For SQL installation on a server, refer to the readme.rtf file on the DVD (MCM\Resources\Installers\readme.rtf) for the various dependencies. 6. Click Next. Issue 1 Rev 2 Page 5 2012 Snell Limited

7. The Install Location screen displays. Fig 4. Install Location 8. Either accept the default destination or browse to a new destination. 9. Click Install. The selected components begin to install. Note: During the installation, do not close the installation wizard or the Centra Configuration Helper. Wait until the entire setup process is complete before exiting the install wizard and Centra Configuration Helper. 10. Once the installation is almost complete, the Centra Configuration Helper displays in a new window. Fig 5. Centra Configuration Helper Issue 1 Rev 2 Page 6 2012 Snell Limited

The Centra Configuration Helper indicates the status of each of the Centra Workbench components. The components can be in one of three states: Green: The component installed correctly. Orange: Optional item that has not been installed. Red (yellow during update): Required by Centra Workbench, but not yet installed. 11. If the Centra Configuration Helper indicates that all components are installed correctly (green), click OK. The Configuration Helper screen closes, and the Completing installation screen dislpays. If the Centra Configuration Helper displays components that have not installed (red) these need to be manually installed before continuing. See Manually Installing Components on page 8. Note: If you try to run Centra Workbench while there are components marked as red, an error message displays. Finish the Installation Fig 6. Completing Installation If you do not wish to start the Centra Workbench immediately untick the Launch Workbench tick box. Click Finish. See Starting Centra Workbench on page 18. Issue 1 Rev 2 Page 7 2012 Snell Limited

Manually Installing Components Centra Configuration Helper Display The Centra Configuration Helper graphically shows the installation status of the Centra Workbench Components. The Centra Configuration Helper is also available from the Windows Start Menu: Start All Programs Snell Centra Utilities Configuration Helper Each component has information about its status. Click on to expand each component s details. Click on to close the component details. The different components are listed in Table 2. Computer Microsoft Data Access Components (MDAC) Visual C++ Redistributable SQL server [1] SQL Server [1] Management Studio Workbench Database Licensing Database Table 2. Centra Workbench Components [1] Not required for distributed systems. Displays information about the PC on which the Centra Workbench is installed. Displays information about the MDAC such as installed yes/no, Version number and whether or not the MDAC installation meets the requirements of Centra Workbench. Displays information about the Visual C++ installation. Displays information about the SQL server such as installed yes/no, version number and type of installation. Displays information about the SQL Server Management Studio. Displays information about the Workbench Database and allows connection changes. Displays information about the Licensing Database. Note: Until you connect to a Workbench Database and Licensing Database, these components display in red as, required but not installed. Support If you have problems with the installation at any time and you contact customer support (customersupport@snellgroup.com), you may be asked to provide information about your installation. Click Copy to Clipboard, and paste the information into the email. Issue 1 Rev 2 Page 8 2012 Snell Limited

Computer Displays information about the PC on which the Centra Workbench is installed. Fig 7. Installed Computer Component If this component installs but displays orange, check that the PC conforms to the system requirements at the beginning of this guide. See System Requirements on page 3.. Microsoft Data Access Components Displays information about the Microsoft Data Access components, for example, version number and installation status. Fig 8. Installed Microsoft Data Access Components Issue 1 Rev 2 Page 9 2012 Snell Limited

This component is required to run the Centra Workbench. If the component displays as red the installation was incomplete. Restart the installation. Visual C++ Redistributable Displays information about the Visual C++ Redistributable component, for example, version number and installation status. Fig 9. Installed Visual C++ Redistributable Component This component is required to run the Centra Workbench. If the component displays as red the installation was incomplete. Restart the installation. SQL Server Important: The version of SQL Server on the installation DVD is 2008 R2. If you already have SQL Server 2005, it is not essential to upgrade. However, the default database on the installation DVD is version 2008 R2 and cannot be imported to the 2005 or 2008 version. If any version of SQL server is installed, the Centra Workbench Installation Helper displays this component as installed (green). The SQL Server is optional. For a server installation where the database server is elsewhere on the network, do not install this component. Issue 1 Rev 2 Page 10 2012 Snell Limited

Fig 10. SQL Server Component To install the SQL Server or to upgrade from the 2005 version on a standalone installation, click Click here to install the SQL Server Express Edition. An install wizard starts and runs through several screens installing both the SQL Server and SQL Server Management Studio. Do not interrupt the wizard. Once the wizard is complete, both the SQL Server and SQL Server Management Studio components display green. SQL Server Management Studio To install the SQL Server Management Studio on a server installation, click Click here to install the SQL Server Management Studio Express Edition. For a standalone PC this SQL Server Management Studio component is also installed automatically when the SQL Server wizard is run. See SQL Server on page 10. Workbench Database Important: The Workbench database must be installed on the server. Therefore, unless already installed, you must install SQL Server Express and SQL Server Management Studio (or optional SQL DB Tool) on the server. Centra Workbench requires a working connection to the Workbench database. Until you connect to the database, the Centra Install Helper displays the connection as red (required by Centra Workbench, but not yet installed). Issue 1 Rev 2 Page 11 2012 Snell Limited

Fig 11. Workbench Database There are two options for connecting to a Centra Workbench database: Create a new blank database. Connect to an existing database either locally or on the network. Create a New Workbench Database To create a new Centra Workbench Database: 1. Expand the Workbench Database section. 2. Click Click here to create databases and permissions. A command window displays briefly and connects to the database. 3. From the Centra Install Helper, click the Refresh button. 4. The Workbench Database displays green (installed correctly). Connect to an Existing Workbench Database If you have an existing Workbench database, you must provide the file path, and login credentials: 1. Expand the Workbench Database section. Click Click here to alter database connection settings. 2. The Connection String Editor dialog box displays. Issue 1 Rev 2 Page 12 2012 Snell Limited

Fig 12. Workbench Database Connection Settings 3. Either, type the server details, or edit the Database Connection String.. Note: The Server Name can be an IP address or a name. On a standalone PC only, the Server Name must also contain \SQLEXPRESS at the end. 4. Click OK. 5. From the Centra Install Helper, click the Refresh button. 6. The Workbench Database displays green (installed correctly). Licensing Database Important: The Licensing database must be installed on the server. Therefore, unless already installed, you must install SQL Server Express and SQL Server Management Studio on the server. Centra Workbench requires a working connection to the Licensing database. Until you connect to the database, the Centra Install Helper displays the connection as highlighted red (required by Centra Workbench, but not yet installed). Issue 1 Rev 2 Page 13 2012 Snell Limited

Fig 13. Licensing Database There are two options for connecting to the Licensing database: The database is installed locally as part of the Centra Workbench core installation. Connect to an existing database either locally or on the network. Connect to the Example Licensing Database To connect to the Licensing database: 1. Expand the Licensing Database section. 2. Click on Click here to create databases and permissions. A command window displays briefly and connects to the database. 3. From the Centra Install Helper, click the Refresh button. 4. The Licensing Database displays green (installed correctly). Connect to an Existing Licensing Database If you have an existing Licensing database, you must provide the file path, and login credentials: 1. Expand the Licensing Database section. 2. Click on Click here to alter database connection settings. 3. The Connection String Editor dialog box displays. Issue 1 Rev 2 Page 14 2012 Snell Limited

Fig 14. Licensing Database Connection Settings 4. Either, type the Server details (including file path), or edit the Database Connection String. 5. Click OK. 6. From the Centra Install Helper, click the Refresh button. 7. The Licensing Database displays green (installed correctly). Managing Databases Using the SQLDBTool The SQLDBTool simplifies the management of databases. It allows for the creation of new blank databases and the backup and restoring of existing databases. The SQLDBTool is available from the Windows Start Menu: Start All Programs Snell SQLDBTOOL SQLDBTool Fig 15. SQLDBTool Screen Issue 1 Rev 2 Page 15 2012 Snell Limited

Create a Blank Database 1. Select the server name from the drop down list at the top of the screen. 2. Click Connect and Get Databases. 3. Type a name for the new database in the Target database field. 4. In the Operation section of the screen ensure that the Backup Mode radio button is selected. 5. Browse to the path of where the backup files for the database are to be saved. 6. Click Create Database. Restore a Database 1. Ensure the Restore Mode radio button is selected. 2. Click Retrieve file names from backup. 3. Click Restore Database. When prompted to Overwrite existing database, click Yes. 4. When the restore is complete, a dialog box displays. Click OK. Backup a Database 1. Ensure the Backup Mode radio button is selected. 2. Browse to the path of where the backup files for the database are to be saved. 3. Click Backup Database. Create a Blank Database Using SQLMS To create a new database, you must have SQL Server Express and SQL Server Management Studio installed on the server. To create a new database: 1. Start SQL Server Management Studio. You are prompted to confirm the server name and login credentials. 2. Right-click the databases node in the object explorer and select New Database. 3. Type the name of the database in the Database name field (the default is Workbench). 4. Click OK. No further configuration of this database is required. The Workbench application configures the remainder of the database settings and builds all of the tables. Install Default Databases Important: The default databases on the installation DVD are SQL version 2008 and cannot be imported to 2005. To install the Centra Workbench default databases, you must upgrade to SQL Server 2008. When a Centra Workbench database is converted to SQL Server 2008, it is not possible to revert back to SQL Server 2005. Therefore, if you have an existing version of the Centra Workbench database, it is important that you make a full backup before upgrading. Issue 1 Rev 2 Page 16 2012 Snell Limited

The default databases each have several example controllers and hardware panels, and are on the installation DVD. To install the sample database: 1. Browse to the installation CD-ROM and open the Nucleus Default Configurations folder. The example databases are in.zip folders. 2. Right-click the required.zip file and select Extract All the Extraction Wizard displays. Click Next. 3. Browse to an appropriate location for the files, and click Next. A.bak file is extracted to the selected location. Click Finish. 4. Make sure that Centra Workbench is not open. 5. Open SQL server management express and connect to the server. 6. Expand the Databases folder. Right-click on the Workbench database and select Tasks Restore Database. 7. In the Source for restore section, select From device and click the (browse) button. The Specify Backup dialog box displays, click Add. 8. Locate the.bak file, select it and then click OK. 9. In the Specify Backup dialog box, click OK. 10. Select the file from the Select the backup sets to restore section of the Restore Database dialog box. 11. In the Select a page section, click Options. Select Overwrite the existing database and Leave the database ready to use (RESTORE WITH RECOVERY). 12. Click OK, and close SQL server management express. The first time that you start Centra Workbench, you must Update the Database. Issue 1 Rev 2 Page 17 2012 Snell Limited

Starting Centra Workbench Start the Workbench Application When the Centra Install Helper indicates that all required components have installed correctly, you can start the Centra Workbench. If you did not launch the Workbench from the installer, do one of the following: Double-click the Workbench icon on the desktop. Start the program from the Windows Start menu. The path to Workbench in the Start menu is: Start All Programs Snell Centra v3 Workbench The first time that you start Centra Workbench, the database must be updated. Fig 16. shows the initial screen. This screen displays whenever you install a new version of Centra Workbench, or make changes to the database. For example, if you install one of the sample databases. Important: If you have not made any changes and this dialog box displays, contact your system administrator. Fig 16. Update Database To view the differences between the databases, click the button. The Database Analyzer screen displays, showing the parts of the database that will change when you update the database, see Fig 17. Note: You cannot start Centra Workbench without agreeing to update the database. Fig 17. Database Analyzer - Example list of possible changes 1. Click Update Database, and the enter password dialog box displays. Type the Database Update password. The default Database Update password is workbench. Issue 1 Rev 2 Page 18 2012 Snell Limited

Note: The password is case-sensitive; by default, all lower-case. A progress screen displays, indicating that the database update is in progress. The database update can take several minutes to complete. 2. Click OK. The login screen displays, see Fig 18. Fig 18. Login Screen Log In to Workbench When Workbench is first installed, there are only two users, see Table 3. User admin user Table 3. Password admin (none required) Default Users Note: If you are using a touch-screen interface, an on-screen keyboard is available. Click on the keyboard symbol. 1. Type a user name. 2. Type a password, if required. 3. Click Login or press the Return key. The home screen displays, see Fig 19. Fig 19. Initial workbench Administration Screen Issue 1 Rev 2 Page 19 2012 Snell Limited

Home Screen The Home screen provides access to the various Workbench functions. You can open the Workbench functions from the icons on the screen, toolbar buttons or menu, see Fig 20. Fig 20. Home Screen (with Full Access) LiveRunner LiveRunner an optional component of the Centra Workbench installation. LiveRunner is the Centra live control and monitoring (run mode) client. It makes it possible to run a screen without running Centra Workbench. LiveRunner is available from the Windows Start Menu: Start All Programs Snell Centra LiveRunner The Login Window displays, see Fig 21. 1. Type a user name. 2. Type a password, if required. 3. Click Login or press the return key. Fig 21. LiveRunner Log-in Note: You must assign an Initial Screen to a user otherwise an error message displays when the user logs in to LiveRunner. This error also displays if you try to enter Run mode. Issue 1 Rev 2 Page 20 2012 Snell Limited

Command Line Parameters You can create a shortcut to LiveRunner that includes several command-line parameters so that the shortcut displays a specific screen. The options are: -username (or -user or -u) followed by a Centra Workbench user name. -password (or -pass or -p) followed by the matching Centra Workbench password. -fullscreen (or -f) = Run in full screen mode To create a shortcut: 1. From Windows, browse to C:\Program Files\Snell\Workbench\LiveRunner.exe. 2. Create a shortcut to LiveRunner.exe. 3. Right-click on the shortcut and select Properties. 4. At the end of the Target (after the LiveRunner. exe ), type the required command-line parameters. 5. Click OK. 6. Double-click the shortcut to open the screen. Configuration Helper Utility The Configuration Helper can be accessed from the Start menu, in case further configuration is necessary afer the initial installation. Configuration Helper is available from the Windows Start Menu: Start All Programs Snell Centra Utilities Configuration Helper Issue 1 Rev 2 Page 21 2012 Snell Limited

Add a Controller Adding a New Controller In this example a Pyxis router is added. Select the settings relevant to your controller. 1. Click Add Controller and the Controller Wizard displays. Fig 22. Controller Wizard - Select Controller Type 2. From the drop down list, click Nucleus Controller (2450). 3. Click on the appropriate radio button according to the configuration required. To Configure a New Router on the Network: 1. Select the first radio button I have a controller available on the network and I need to copy to my local settings. 2. Click Next. Issue 1 Rev 2 Page 22 2012 Snell Limited

Fig 23. Controller Wizard - Set Controller Name 3. Type a name for the controller. 4. Edit the IP Address and Port to match those set in the CompactFlash in the controller. If these are unknown, extract the CompactFlash from the controller and place it into a card reader to view the IP address. Refit the CompactFlash back into the controller. 5. Click Next. Fig 24. Controller Wizard - Check Details Issue 1 Rev 2 Page 23 2012 Snell Limited

6. Confirm that details for the controller configuration are correct. 7. Click Finish. 8. The controller is configured. Fig 25. Controller Added To Configure a New Controller for Future Use: 1. Select the first radio button I am working offline and want to create a new controller to use at a later time. 2. Click Next. Issue 1 Rev 2 Page 24 2012 Snell Limited

Fig 26. Controller Wizard - Set Controller Name 3. Type a name for the controller. 4. Edit the IP Address and Port to match those set in the CompactFlash in the controller. If these are unknown, extract the CompactFlash from the controller and place it into a card reader to view the IP address. Refit the CompactFlash back into the controller. 5. Click Next. Fig 27. Controller Wizard - Set Router Type Issue 1 Rev 2 Page 25 2012 Snell Limited

6. Click the radio button to Use a Factory Or User Default. 7. From the Router Type drop down list, click Pyxis. 8. From the Router Configuration drop down list, click on the relevant row for the router which has the closest specification to the router you are configuring. 9. Click Next. 10. A summary screen displays. If any of the parameters on this screen are incorrect, click Previous to return to the screen that requires amendment. Edit the details, and continue through the Controller Wizard as before. 11. Click Finish. Issue 1 Rev 2 Page 26 2012 Snell Limited

Troubleshooting Introduction This section describes the extra screens that may display during the installation process on different operating systems, or when installing on a PC that already has a Centra Workbench installed. User Account Control On Windows 7, the User Account Control screen displays when starting the installer. Fig 28. Allow Changes Click Yes to continue..net Framework 4 Installation If your PC does not have ".NET Framework 4." the Workbench installer will install the required files. Fig 29. Restart PC You must restart your PC when prompted. Click Yes to restart the PC. The PC will reboot and the installation restart automatically after logging into the PC. If you click No another prompt displays asking you to restart the PC to proceed. Now you have to cancel the Workbench installation yourself, reboot your PC and then once logged in restart the installation manually. Issue 1 Rev 2 Page 27 2012 Snell Limited

Windows Installer The Windows Installer screen may display during the installation process. Fig 30. Windows Installer Screen Click OK. The installation continues. Install Checker If the Install Checker screen displays, it is probably due to you not having Administration rights on your PC for when the Configuration Helper starts. Fig 31. Install Checker Screen To run the Centra Configuration Helper, open: Start All Programs Snell Centra Utilities Configuration Helper Right-click on Configuration Helper and select Run as Administrator. Issue 1 Rev 2 Page 28 2012 Snell Limited

Fig 32. Run as Administrator Issue 1 Rev 2 Page 29 2012 Snell Limited