ADDENDUM : APPA RS-232 PROTOCOL FOR DMM 301, 303, 305 USING WITH APPA RS-232 CABLE SOFTWARE LICENSE AGREEMENT FOR APPA WinDMM / 98 / NT

Similar documents
Model R5005. Instruction Manual. True RMS Industrial Multimeter. reedinstruments. www. com

PeakTech Prüf- und Messtechnik

Power Level Converter 3110 PC. C. Frame format The length of the frame is 26 bytes (compatible with FAB). The form is as the following:

15. Check this point when you can t communicate

DIGITAL MULTIMETERS. Accuracy +5% Resolution 1pF Accessories Test leads, Manual, 9V Battery included Options ST-265, C-90, C W x 6 L x 1.

The benefits are ease of set-up, more data available for the user from the drive, fast control, and state of the art technology.

AC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

Clamp meter with Data recorder SERIES set

AC/DC MAGNETIC METER OPERATION MANUAL. Model : PCE-MFM G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

Model A Mini AC/DC Clamp Meter. User's Guide

ATL55, AAC3, ATT29, ATT70, 9V Bat., AF38, AF39. Range Resolution Accuracy DC Current DM393 DM µA 0.1µA 1.0% % + 2

USER'S MANUAL DCL-650

PRODUCT. Data Sheet. Introducing the new Fluke-287 Advanced Logging Multimeters with Trend Capture

Monarch Instrument 2002 all rights reserved MONARCH INSTRUMENT. True RMS Multimeter. Instruction Manual. Monarch 120

Modbus Protocol For FTS/FTM 3x&8x

Product Family: GS Drives Number: AN-GS-006

AT45DB021D and AT45DB021E Comparison. Adesto Field Application

zigb232 & zigb485 User Guide User Guide TANGENT TECHNOLABS

Wireless TRMS Multimeter and Insulation Tester

VariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www.

OPERATING INSTRUCTION

DVIF10. Dry or Voltage Input Interface

NEW! 6.5 Digit Precision Multimeter from Fluke

AT45DB321D and AT45DB321E Comparison. Adesto Field Application

REV: C JAN 2008 GIGA-TMS REGISTERED TO ISO

MTP INSTRUCTION MANUAL

AT45DB642D and AT45DB641E Comparison. Adesto Field Application

True RMS Industrial Multimeter Extech EX530

TZW803+ 8x1 VGA/XGA & AUDIO SWITCHER. ELPRO Video Labs s.r.l. St.da della Pronda, 45/B Torino ITALY Tel Fax

OPERATION MANUAL. SD card real time data Recorder, USB/RS232 SOUND LEVEL METER. Model : SL-4023SD. Your purchase of this

PM PDRB X DATA SHEET. Memory Module Part Number. PM MByte Non ECC BUFFALO INC. (1/15)

AC/DC Modular Power Supply Series PMBus APPLICATION NOTES

VariTrans P The Problem The variety of tasks results in a large number of different devices.

Model R5010. TRMS Digital Multimeter. Instruction Manual

JSD81 series products are based on SCM's intelligent monitoring and control system, users set the calibration value,

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

AC/DC MAGNETIC METER

DSP860 Operation Manual

DSP840 Operation Manual Version 3.0

DT4250 Series DIGITAL MULTIMETER

Wireless TRMS Multimeter

DATASHEET 4D SYSTEMS. Serial JPG Camera Module TURNING TECHNOLOGY INTO ART. Document Date: 5 th September 2012 Document Revision: 1.

4K LASER FRONT PROJECTOR REMOTE CODES

Alarm Interface Utility Software V3.1.3

ShenZhen Top Create Electronic Co.,Ltd. Website: Tel: CJ - CAM User Manual.

True RMS Digital Bench Multimeter Model:

1:N REDUNDANT SWITCHING UNIT REMOTE CONTROL TERMINAL

User s Manual. Mini MultiScope II MODEL

ENGINEERING SPECIFICATION. 65W AC Adaptor. Part Number: PA P1

Digital Clamp Meter User Manual

INVERTER E510. Communication Addendum. ModbusRTU/ASCI. DOCUMENT-TECO-E510-AC001 Ver01:

Wireless TRMS Multimeter

OPERATING MANUAL INDUSTRIAL MULTIMETER CMM-40

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

Autoranging Mini Multimeter

BARCODE SCANNER. Configuration Guide - 1 -

Digital Projector X30N/X35N

RS-232 Command Protocols

Technical Description. Wired M-Bus. Water Meters flowiq 2101/3100

TENMA INSTRUCTION MANUAL MULTI-TESTER

Autoranging True RMS Multimeter User Manual

3 in 1, Type K/J, Pt 100 ohm, Infrared Thermometer Real time data logger, Data logger no., RS232 THERMOMETER.

Serial JPEG Camera Module Data Sheet

Analog signal to RS485 or RS232 Converter, A/D Converter

Citrix IMA Service Error Codes

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer. User's Guide

IT6800 series Frame Format

E2 Modbus RTU Register Map Revision History Version Comments Author Date 1.02 Previous version PAE 11/06/ Revised to new format PAE 09/03/09

DS1305. Serial Alarm Real Time Clock (RTC) FEATURES PIN ASSIGNMENT ORDERING INFORMATION

Wireless TRMS Multimeter and Insulation Tester

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this

Sound Level Meter SL-4035SD. Operation Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

ModBUS Protocol for SMART 3

EFE300 / EFE400 EFE300M / EFE400M

AC/DC Power Supply Series APPLICATION NOTE

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

Serial JPEG Camera Module Data Sheet

UNIVERSAL CURRENT CONVERTER

CT-510. Multifunctional CCTV Tester. User Manual

Digital Clamp-on Meter Instruction Manual

SBS 600. User Manual. Graphical Digital Multi-meter. SBS-600 Users Manual Revision 1.0-5/2014

Fluke 3000 FC Series Test Tools Technical Data

Tongta Inverter TDS-F8

DS1306. Serial Alarm Real Time Clock (RTC)

REV: PAGE: REVISION DESCRIPTION APPR: DATE: B - Released as a standard product. GRW 11/05/96

PRODUCT. Data Sheet. The new Fluke-289 Advanced Logging Multimeters with Trend Capture

RM35LM33MW liquid level control relay RM35-L V AC/DC

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

NC-1200 BARCODE SCANNER. Configuration Guide - 1 -

Sequential Event Recorder

RM35LM33MW liquid level control relay RM35-L V AC/DC

Before powering on your driver, read this manual thoroughly. If you have any doubt or suggestion, please do not hesitate to contact us!

190 Series. Digital Multimeter. Test Products International, Inc. 190 Specifications ±0.05% Basic DCV Accuracy. Instruction Manual

SMD SERIES INVERTER MODBUS CONTROL OPERATION MANUAL. Document: SLmod-e2

NF760 Batch Controller

TOA IC-100 Institutional Intercom. Remote Control and Monitoring Programmer's Guide

Transcription:

ADDENDUM : APPA RS-232 PROTOCOL FOR DMM 301, 303, 305 USING WITH APPA RS-232 CABLE SOFTWARE LICENSE AGREEMENT FOR APPA WinDMM300 95 / 98 / NT IMPOTANT : Please read carefully before using the Software Protocol. This APPA WinDMM Software License Agreement ("SLA") is a legal agreement between you ( either an individual or a single entity) and APPA TECHNOLOGY CORP. for the APPA WinDMM SOFTWARE PRODUCT AND DOCUMENTATION identified above, which includes RS-232 Protocol. The SOFTWARE PRODUCT AND DOCUMENTATION provided to you by APPATECHNOLOGY CORP. is protected by copyright laws and international copyright treaties, as well as other intellectual property laws and treaties. As you receive this SOFTWARE PRODUCT AND DOCUMENTATION, you are agree to became bound by the terms of this agreement. The license allows you to use the SOFTWARE PRODUCT AND DOCUMENTATION for internal purposes only on a single computer. You may not market, distribute or transfer copies of SOFTWARE PRODUCT AND DOCUMENTATION to others or electronically transfer the SOFTWARE PRODUCT AND DOCUMENTATION from one computer to another over a network, you may not decompile, reverse engineer, disassemble or otherwise reduce the of the SOFTWARE PRODUCT to a human perceivable form. The RS-232 protocol is one part of the APPA WinDMM and is exactly and completely the same as the APPA WinDMM, but no other warranties for the end user to write a driver using this RS-232 protocol. The RS-232 protocol : 1. Communication Type : RS-232C 2. Communication protocol : A : Baud Rate : 9600 bps B : Data length : 8 bits C : Parity check : None D : Stop bit : 1 bit 3. Data format : The data format is ASCII. 1

A. PC sends a command to DMM for requesting to read as follow : 55H 55H 00H 00H AAH After sending the command, wait for receiving data format from DMM, the time out setting must be bigger than 450ms. B. When DMM receives the command from PC, will send the data format to PC as follow : 55H 55H 00H 36H Model Name (8 bytes) Series Number (8 bytes) S/W Version (7 bytes) Switch Blue Key Range Reading of Code Code A/D Convert Data of Main Display (6 bytes) Data of Left Display (6 bytes) Data of Right Display (6 bytes) Reading(DC) of (AC+DC) (3 bytes) Reading(AC) of (AC+DC) (3 bytes) Check sum 4. 2

a. Model Name 41H 42H 31H 43H 32H 44H 33H (A) (B) (1) (C) (2) (D) (3) b. Series Number 45H 34H 46H 35H 47H 36H 48H 37H (E) (4) (F) (5) (G) (6) (H) (7) c. S/W Version 2EH 2EH 36H (.) (.) (6) d. Switch 00H 01H 02H 03H 04H 05H 06H 07H 08H 09H OFF V mv Ohm Diode ma A Cap. Hz Temp. e. Blue V mv Ohm Diode ma A Cap. Hz Temp. 00H DC DC Ohm Diode DC DC Cap Hz deg.c 01H AC AC Low Ohm Beeper AC AC ------- Duty Factor deg.f 02H AC+ DC AC+ DC ------- ------- AC+ DC AC+ DC -------- -------- -------- f. Key 01H 02H 03H 04H 05H 06H 07H 08H 09H 0AH F1 F2 F3 F4 Light Bar Digit Range o Blue g. Range 3

00H 01H 02H 03H 80H 81H 82H 83H DC V AC V (AC+DC) V DC mv AC mv (AC+DC) mv 4V 4V 4V 40mV 400mV 400mV 40V 40V 40V 400mV 400V 400V 400V 1000V 750V 750V 4V 4V 4V 40mV 400mV 400mV 40V 40V 40V 400mV 400V 400V 400V 1000V 750V 750V 00H 01H 80H 81H DC ma AC ma (AC+DC) ma DC A AC A (AC+DC) A 40mA 40mA 40mA 4A 4A 4A 400mA 400mA 400mA 10A 10A 10A 40mA 40mA 40mA 4A 4A 4A 400mA 400mA 400mA 10A 10A 10A Ohm Low Ohm Cap Hz Diode Temp 4

00H 01H 02H 03H 04H 05H 06H 07H 80H 81H 82H 83H 84H 85H 86H 87H 400Ohm 4kOhm 4nF 400Hz Diode Temp 4kOhm 40kOhm 40nF 4kHz 40kOhm 400kOhm 400nF 40kHz 400kOhm 4MOhm 4µF 400kHz 4Mohm 40MOhm 40µF 4MHz 40Mohm 400µF 4mF 10mF 400Ohm 4kOhm 4nF 400Hz Diode Temp 4kOhm 40kOhm 40nF 4kHz 40kOhm 400kOhm 400nF 40kHz 400kOhm 4MOhm 4µF 400kHz 4Mohm 40MOhm 40µF 4MHz 40Mohm 400µF 4mF 10mF h. Reading of A/D Convert 5

Low High Pole If pole byte > 7FH then Reading = [(Low byte)+(high byte x 256)] x (-1) other Reading = (Low byte)+(high byte x 256) i. Main display Low High Pole Point Unit Sub If pole byte > 7FH then Reading = [(Low byte)+(high byte x 256)] x (-1) other Reading = (Low byte)+(high byte x 256) j : left display Low High Pole Point Unit Sub If pole byte > 7FH then Reading = [(Low byte)+(high byte x 256)] x (-1) other Reading = (Low byte)+(high byte x 256) k. Right display Low High Pole Point Unit Sub If pole byte > 7FH then Reading = [(Low byte)+(high byte x 256)] x (-1) other Reading = (Low byte)+(high byte x 256) POINT CODE : 6

CODE POINT 00H NONE 01H POINT 1 02H POINT 2 04H POINT 3 08H POINT 4 Remark : 4. 0. 0. 0. 0 POINT 1 POINT 2 POINT 3 POINT 4 2.UNIT CODE : CODE UNIT CODE UNIT 00H NONE 0EH Delta 01H V 0FH Hz 02H mv 10H khz 03H A 11H MHz 04H ma 12H deg.c 05H db 13H deg.f 06H dbm 14H s 07H nf 15H ns 08H µf 16H µs 09H mf 17H ms 0AH Ohm 0BH kohm 0CH MOhm 0DH % 7

3.SUBFUNCTION CODE : CODE DATA 00H NONE 01H Input Reading 02H Freq. 03H Period 04H Duty Factor 05H Ambient Temperature 06H Time Stamp 07H Load 08H Number (Store, Recall) 09H Store 0AH Recall 0BH Reset 0CH Auto Hold 0DH Max 0EH Min 0FH Max-Min 10H Peak Hold Max 11H Peak Hold Min 12H Peak Hold Max-Min 13H Set High Indication 14H Set Low Indication 15H High 16H Low 17H Delta 18H % 19H Ref 1AH dbm 1BH db 1CH Send 1DH Setup Indication 1EH Set Beeper Indication 8

CODE DATA 1FH Set Auto Power off Indication 20H Set Back Light Indication 21H Set Hazard Indication 22H Set Line Frequency Indication 23H Set dbm Load Indication 24H Set Reset Indication 25H 26H Probe Indication 27H Error Indication 28H Fuse Indication Checksum: The last byte is the SUM of every byte in the received data format except Checksum itself, you can use the Checksum (using the last tow digits) to check the data receiving from DMM is correctly or not. Example for Checksum : 55+55+0+36+41+50+50+41+33+30+35+20+53+61+6E+64+72+61+20+20+30+ 2E+30+30+2E+30+36+1+0+0+0+1+0+80+1+0+0+8+1+1+0+0+0+0+0+0+0+0+ 0+0+0+0+0+0+0+0+0+0 = 732 9