JKA multi-valve controller

Similar documents
JKA STAGER CONTROLLER SERVICE MANUAL

C Heat Trace Controller

RS-FX-N01 wind transmitter user's Guide (485type)

FS-21.doc Status Filter Control FS-21. EasyRange

RS-FS-N01 Wind speed transmitter user's Guide (485type)

NF760 Batch Controller

Modbus communication module for TCX2: AEX-MOD

TORRIX RS485. Technical Documentation. with MODBUS Protocol. Edition: Version: 2 Art. no.:

F-3100 FLOW METER NETWORK INTERFACE Installation and Operation Guide

System Controller Programming Manual

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

GFC111-MB. Flow Computer With RS485 MODBUS FEATURES 1. DESCRIPTION APPLICATIONS

FP735Si Electronic 3-Channel Full Programmer for Heating and Hot Water with Service Interval Timer. Installation Guide MAKING MODERN LIVING POSSIBLE

ioselect Z-NET Z-SG Bridge Input Isolating I/O Module

SYSTEMAX 2014 MULTIVALVE ELECTRONIC CONTROLLER WITH DEMAND RECALL

Manual 09/11 MN Z-EN. NZM-XATS-C Automatic Transfer Switch-Controller Modbus Communication Protocol

SA-027WQ. Manual. 7-Day Timer. Lighting Systems Access Controls Security Systems Environmental Controls. Automate the following:

Modbus Integration Integration for Modbus Functionality for VTR8300 Series

T4HD: Installation Supplement R8.1.13

VAT series controller and transmitter. Manual

Scanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A

1. Supplied Items. 2. Connecting the DTS SKT. Input side. Input Side

VMB4PD Push Button and Timer Module for Velbus System

Induction Flow Meter. AcquaMAG. Installation and Operating Manual

Compressor Controller MAM 890

Instructions ECL Comfort 210 / 296 / 310, communication description

RHT-WM-485-LCD Transmitter and RHT-DM-485-LCD Transmitter

Zenith DS9000 Dispensing System

LDCL DIGITAL CONTROLLER OPERATING MANUAL

UniPak UP448 Bridge Input Isolating Signal Conditioner

VP Process Inc. Model: VP-EC-RDU Modbus RTU LCD Display

LC3 LIGHTING CONTROLLER OPERATIONS & MAINTENANCE MANUAL 2013 Dec

MEMS Mass Flow Meter. User Manual (V A.4) MF5700 Series SIARGO LTD.

NF770 Temperature Compensation Liquid Flow Computer

TORRIX RS485. Technical Documentation. with MODBUS Protocol. Edition: Version: 3 Art. no.:

G.S.I Controller Web Application. Getting Started Guide

PowerFlex 400 AC Drive Guide Specification

High Voltage DC Meter

BLDA-1 & 2 Water Leak Detection Manual. CMR Electrical Ltd Bolton House Five Chimneys Lane Hadlow Down East Sussex TN22 4DX Tel:

Strain Gauge Converter

Easy Arc Integration into a Simatic S7-300 Process Control System

Model OI x42 ProSafe

Transmitters RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P LCD

Installation and Operation Manual SPC1

Model OI x82 ProSafe

HIGH-VOLTAGE DC METER

COUNTIS Ci Notice d utilisation GB Operating instructions Bedienungsanleitung NL Gebruiksaanwijzing

Access Control Integration Host User s Manual

Model IR4000M. HART Field Device Specification Multi-Point Monitor. Instruction Manual 07-08

Millennium Simplicity Elite Parameter Points and Quirks

Enercept H8035/H8036 Modbus Energy Meter Networked kw/kwh Transducers

HAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL

Optidrive Applications Support Library

MOD. KBC HEAD KONTAX BATCH CONTROLLER

Optidrive Applications Support Library

MTP INSTRUCTION MANUAL

Communication Protocol Manual JOFRA ATC Copyright 2007 AMETEK Denmark A/S

UNILINER RF RTU SYSTEM GUIDE

installation Operation ADDRESS product diagram H8030/8031 INSTALLATION GUIDE

The Tracker. How the Tracker Works

BERMAD Irrigation. BIC Wire RTU

INDUSTRIAL ETHERNET MODULE TBOX Manual

Simplified Operating Instructions T105-C / T108-C / T106-C / T17B-C DISPLAYS DAY OR DAY BLOCK PROG 00:0000 PROG PROG ALWAYS OFF

Module 4. Programmable Logic Control Systems. Version 2 EE IIT, Kharagpur 1

E2 Modbus RTU Register Map Revision History Version Comments Author Date 1.02 Previous version PAE 11/06/ Revised to new format PAE 09/03/09

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703

RoomMaster ABR-2. Commissioning

D-100 FLOW DISPLAY MODBUS Network Interface Installation Guide

U-FLASH Setup Guide U-FLASH.

BIC 100 BERMAD Irrigation Control System

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

SC1000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703

DKM-407 DIN RAIL TYPE NETWORK ANALYZER

User s Manual RD-MV1000/RD-MV2000 M st Edition

Modbus Protocol. for VASCO, VASCO Solar and MIDA devices. manmodbus_eng_00

BNI IOL A027 BNI IOL A027

RADI-CEM. User manual. MPB S.r.l. Via Giacomo Peroni 400/ Rome - Italy. Tel Fax

Click Save to return to the main Setup screen.

Mini Agg 1-10 (DC/AC)

Model S665. Sound Level Analyzer. Users Manual

GPLS-25 DATASHEET Março 2012

EM26-96 COMMUNICATION PROTOCOL. Version 1 Revision 0

Model 500 Digital Weight Indicator

Installation & Operation Guide

45SD Series Bus Expansion Cards For use with Q45X Series Photoelectric Sensors on SDS Bus Networks

ATS CONTROLLER OPERATING MANUAL

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

LD-RTD / LD-TC Temperature Controller

Cảm ơn các bạn đã tham khảo tài liệu cân điện tử từ CÂN ĐIỆN TỬ GIA PHÁT!

HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL

Digital Frequency Divider INSTRUCTION MANUAL CONTENTS. 1. Working Principle Installation Setting Up Technical Data 4.

Installation and User Manual. version 1.00 MODWF 2014/53/UE EN : /30/UE EN55022:2010 EN :2005 EN :2007

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Communicative controller for VAV systems

Manual Control Unit GFCD 16

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

Model OI x22 ProSafe

Power Vision 1.5 (Cod )

Paperless Recorder. User s Manual KT200R IMA22-CP01

Interface Definition RISH EM 2340/1320/30/ _Rev. D - 8/2016

Transcription:

JKA multi-valve controller manual JKA4.0 BEIJING KANGJIE ZHICHEN WATER TREATMENT CO.,LTD Shahe Industrial Zone, Changping District, Beijing, China, 102206 Tel: (+86) 010 69730336 Fax: (+86) 01080706936 www.kangjiezc.com Email: kj@kangjiezc.com

Content 1. General introduction... 3 1.1 Function... 3 1.2 Key and display... 4 1.2.1 Keys... 4 1.2.2 Panel display... 5 2. Parameters setting... 5 2.1 Power supply connection... 5 2.2 Setting procedure... 5 2.2.1 Password input... 5 2.2.2 Time calibration... 6 2.2.3 Plan setting... 6 2.2.4 M program setting... 8 2.2.5 S program setting... 9 3. Input/output equipment... 10 4. Input/output device detection... 11 5. Process test and manpower control... 11 5.1 Main screen... 11 5.2 Manpower initiation or stop... 12 6. Communication... 13 6.1 Reading to device register... 13 6.2 Writing device... 14 6.3 The address of device register... 14 7. Appendix... 18 7.1 K value reference... 18 7.2 Control principle drawing... 18 -! 2 of 19 pages-

1. General introduction JKA Multi-valve controller manual v4.0 1.1 Function JKA multi valve controller is specially designed for filtration, Water Conditioning, Softening, and Desalination systems which consist of multi valves. It has the following superior features: Power: 150~250V/AC. 50/60Hz. The power of motor is 4W. Chinese or English language can be selected. Easily programmed, No knowledge of programming languages needed to operate. Instrument adopt the MODBUS (RTU) protocol with CRC checksum. Password protection design prevents parameter setting from accidental or unexpected alterations. Flexible regeneration initiation modes (Volume, Remote, Interval, Week, Remote control regeneration).the selection of regeneration modes depends on specific technical and systemic conditions. Under special circumstances (e.g. on-site debugging) can be forced to manually start the regeneration. Regeneration can also be interrupted at any time, and any sequence may be skipped. Displays all functions on LCD panel with long lasting backlight that provides over ten years of use. Regeneration and relevant outputs signals are all Relay Dry Contacts. The capacity is 220VAC/5A. JKA Stager Controller contains four specified parameters: a) Plan b) M program c) S program d) Commerce Remote control signal is dry contact. Signal can be reserved at least 2 seconds. JKA Controller equips two sets of level logic control unit with Relay Dry Contact output. -! 3 of 19 pages-

Multiple controllers can be realised peripheral logic chain functionality.that can pass between multiple controllers S1 or S3 program as a neighbouring state feedback from both devices in order to achieve mutual linkage between each other, to avoid the two controllers at the same time start the regeneration process. Peripheral logic interlock function can be implemented among multiple JKA Stager Controllers through using S1 or S3 program of one JKA Stager Controller as state feedback to adjacent one. Hereby, Regeneration initiation on two JKA Stager Controllers is thus avoided. For commercial lock, please contact our technical personnel for further details. 1.2 Key and display 1.2.1 Keys The Six function keys, located directly beneath the display, control the majority of JKA stager operation: ESC: functional exit. ENTER: confirmation/input.!": select /modify parameter. $: move cursor. The setting point is up by 1 when the upward key is pressed each time, and will be down by 1 when the downward key is pressed each time. The cursor on the screen will move right when the rightward arrowhead is pressed, and will move left when the leftward arrowhead is press. Note: keeping any key 5 seconds can get into setting state on main display. -! 4 of 19 pages-

1.2.2 Panel display Working light and Regeneration light separately indicates operational status. Frequent flashing denotes rotational frequency of flow sensor if flow sensor is implemented in system. Send and receive light separately indicate the status of communication when sending or receiving data. 2. Parameters setting 2.1 Power supply connection Properly link JKA Stager Controller to power supply before starting parameter setting. The screen displays as below: 2.2 Setting procedure 2.2.1 Password input Constantly press any key on main display for 5 seconds, the screen will display as follow: Use $ keys :to move cursor, push!" key to modify value, transfer 0000 to 2008. Then press ENTER to get into main menu, screen displays as below: -! 5 of 19 pages-

2.2.2 Time calibration Access to time calibration setting by pushing Clock and ENTER. Screen displays as below: If the time is not consistent with current time, push $ and!" keys to adjust. Then press ESC to return to main menu. 2.2.3 Plan setting Move the cursor to Plan and press ENTER to access plan setting program, display as follows: Mode Address Business Baud rate Mode setting: move the cursor to Mode and press ENTER to access to Modes choice, display as below Note: Which regeneration mode is identified in the light of actual technique. Volume mode selection requires flow sensor matched that can generates rectangular pulse. (We recommend JM-TT flow sensor to match JMA Stager Controller usage) If Volume mode is selected as regeneration initiation mode, then move cursor to Volume and press ENTER to get into Volume mode setting, display as below -! 6 of 19 pages-

Note: K value is pipe coefficient. P is Total volume. Press $ and!" keys to input K value and P value, and then press ENTER to confirm. Accumulative volume value checked by moving cursor on and press EN- TER, then display as below To remove accumulative volume value, press ENTER on the above display and type password 4321. Then press ENTER to confirm this performance. When setting week timing as system regeneration mode, moving cursor on Week timing and press ENTER to access, display as below: Use $ keys :to move cursor, push!" key to sets date and time requested to regenerate, then press ENTER to get into, display as below: Note: Week timing mode, can only be activated once a day. Once select the mode, the specific regeneration time every day need to be set one by one. If you want to regenerate more than once a day, please select the interval mode. Interval mode setting: Move cursor on Interval and press ENTER to get into, display as below: Set interval time from 1 to 9999 minutes, and then press ENTER. -! 7 of 19 pages-

Note: among four regeneration modes, remote mode is highest priority, namely no matter Week timing or Interval mode, as long as Stager controller receives remote signal, it will initiate regeneration program, only one of the other three modes can be selected. Business Lock: if its function is needed please contact to us. Instrument address settings: Use $ key to move the cursor to the "Address" and press the (ENTER) key to enter the "Address" setting, display as below Address 0 0 0 0 pressing the ( $) and (!") keys to modify the device address. The address range is 0 ~ 255. After the modification, press the ENTER button to save the setting and return to the main setting menu. Meter baud rate setting: Use $ key to move the cursor to the Baud Rate" and press the (ENTER) key to enter the setting, display as below Baud rate 29000 Pressing the $ button to modify the baud rate of the device. The baud rate can be set as 1200, 2400, 4800, 9600, 14400 and 19200. After the modification, press ENTER to save the setting and returns to the main setup menu. Note: Baud rate should not be higher than 9600 when RS485 transmission distance exceeds 1200 meters. Shielded cable is highly recommended for use to prevent the influence of other high-voltage or frequency converter on transmission data during transmission. 2.2.4 M program setting Move cursor on M Prog and press ENTER to get into M program setting, display as blow: -! 8 of 19 pages-

Change number of push $ key to change number of stages (1-16 total) and press ENTER (3 stager as example), display as below: Push $and press ENTER to access step width setting of first stage. Adjust this step width based on systematic requirement (from 1 second to 9999seconds). Up completion, press ENTER to confirm this setting. And then go to second stage setting by pressing $. Note: How many total stages needed should be identified by technique of water treatment. For example, normally, Media Filter needs two stages, fast rinse and back wash. Softening system needs three stages, back wash, brine, slow rinse and fast rinse. 2.2.5 S program setting Moving cursor to S Prog and pressing ENTER to access S program setting, screen displays as below. S program including 3 sub-program can be set: S1, S3 program setting: when the cursor is in the 1 position, use!" to select S1 or S3 program, and then press $ to go into setting display. Move cursor ( $) to certain - which stage needs assistant signal output. And then transfer - to * to activate by!". S1 and S3 programs can be any combination of multistep, but are restricted by M program on the number of stages and the step width of each stage. S2 program setting: after setting S1 and S3, press ENTER to go into setting display. -! 9 of 19 pages-

Select Step 00 and press ENTER. Push $ and!" keys to set the number of output stages (This number is limited by the number of main program stages). And then confirm by pressing ENTER. Select delay0000 and press ENTER to set the step width of delay that can not exceed the length of relevant stage in main program. S2 output can only be implemented in one step during regeneration process. Terminal # Connection Communication: Flow sensor input: Remote control: Distributor control: 01# 02# connect to PC, PLC or instrument. Level control output: 10# 11# S1 output 12# 13# S2 output 14# 15# S3 output 03# DC 10v 04# SIN 05# GND 220v power supply: 16# L 17# N 18# F 06 # Remote control signal 07# Interlock startup 08# Interlock startup 09# com 19# white 20# blue 21# black 22# yellow 23# green 24# brown 3. Input/output equipment Note: If SIGNET flow sensor is chosen, linking red line of flow sensor to 04 terminal SIN. And black line and shield line both link to 05 terminal GND. 03 terminal is no connection.if the JM-TT sensor is selected, it should be wired as follows: linking red line to 03 terminal + 10V, sensor black (white) line connected to 04 terminal SIN, shield line to 05 terminal GND. Instructions: 1) when terminal 05 and 09 are short circuit, the regeneration program can be started after 2 seconds. 2) regeneration of JKA Stager Controller is restrained in 5 seconds when terminal 07 and 09 are shorted. As far as disconnection, regeneration can be available. 3) Any time both 08 and 09 terminal short circuit will disable the device regeneration. -! 10 of 19 pages-

4. Input/output device detection Test setting: on the main menu display, operate $ button to select Test and press ENTER to get into setting state. Display as below. Press ENTER to go into the first step of program. Inspect validities of equipment and valve s connection before press ENTER to go into the second stage of program. The screen display is similar to the first step. Sequentially complete all the steps and then check if the process of all connected devices meets the requirements. 5. Process test and manpower control 5.1 Main screen According to various systematic operational states, Screen may display current systematic state information. Under the working status, display as below: Acquire present date, time, and next regeneration time from main screen, when Week timing mode is adopted. Easily obtain volume, flow rate, and total volume in a set time period on main screen, when Volume mode is adopted. -! 11 of 19 pages-

Know present date, time, week and remote regenerate control when Remote mode is selected. JKA stager controller activates regeneration when residual flow rate/time value reaches setting or received remote signal. Under the regeneration states, screen displays various stages information accorded with below: Manu Step 1/3 Pass 3s Regeneration startup and stager 3s delay Pass time and left time decrease by seconds. Program will go into next stage when Manu Step 1/3 Pass 900s Manu Step 2/3 Pass 3s Manu Step 2/3 Pass 3600s First stage of main program startup and related S program startup at the same time First stage of main program over and second stage startup, 3s delay Second stage of main program startup, related S program startup at the same time Manu Step 3/3 Pass 3s Second stage of main program, 3s delay Manu Step 3/3 Left 900s 2006-03-21 TU 14:18:58 Next Remote Third stage of main program startup, related S program startup at the same time Regeneration over and back to startup display. Stager go into service state 5.2 Manpower initiation or stop Move cursor by pressing $ to Manu, and then push 强制 to initiate regeneration. Display as below: -! 12 of 19 pages-

When regeneration program initiated, residual time of first stage decreases by 1. Till zero, program goes into second stage of the process, followed by all the steps. Regeneration program automatically exit after the program is finished. Press ESC constant for 5 seconds to stop regeneration, display as below. ENTER skip 1/3 Left 600 Press ENTER to skip one stage and proceed directly to the next step. Press again (EN- TER) key to skip all the steps until all over. 6. Communication Instrument is equipped with RS485 communication interface, and adopt the MODBUS (RTU) protocol with CRC checksum. Communication format: 8 data bits, 1 starting bit, 1 stop bit,no parity. In the use of configuration software, the equipment require Modicon PLC, which use Modbus-RTU address type, 16 bits integer data type. (For some configuration software, 3X register bank should be selected). 6.1 Reading to device register PC instructs format as below: Device address (1 byte) + Read (1 byte) + Register first address (2 bytes) + the number of Reading (2 bytes) + Check code (2 bytes) Device return data format: Device address (1 byte) + Read (1 byte) + number of bytes of data (1 byte) + data +Check code (2 bytes) For example, the device issues a read command: 00 03 00 00 00 01 85 DB; The instrument returns data: 00 03 02 00 10 84 48. -! 13 of 19 pages-

Description of the send command: 00 is the address of the machine, 03 is the read command, 00 00 is the first address of the read register, 00 01 is the number of read addresses, and 85 0B is the check code of the current data, which is calculated by program. Description of the returned Data: 00 the machine address, 03 for the read command, 02 returned data is 2 bytes; 00 10 returned data, 84 48 check code, run by the program. 6.2 Writing device PC sends the instruction in following format: Device address (1 byte) + Write (1 byte) + Register first address (2 bytes) + Written data (2 bytes) + Check code (2 bytes) Return from write device registers: 01 06 00 06 00 12 E9 C6 Here, 01 write device address, 06 write command, 00 06 register address, 00 12 data to be written, E9 C6 check code. 6.3 The address of device register Address of register Description Range Function 0 Year (Current time) 0-99 read and write 1 Month (Current time) 1-12 read and write 2 Day (Current time) 1-31 read and write 3 Hour(Current time) 0-23 read and write 4 Minute (Current time) 0-59 read and write 5 Second (Current time) 0-59 read and write 6 Week (Current time) 0-6 read and write 7 Mode: Volume, Week timing, Interval, Remote 0-3 read and write 8 To next start time (Hour) 0-99 read only 9 To next start time (Minute) 0-99 read only 10 To next start time (Second) 0-99 read only 11 Flow sensor coefficient (High) 0-65535 read and write -! 14 of 19 pages-

12 Flow sensor coefficient (Low) 0-65535 read and write 13 Instantaneous flow (high) 0-65535 read only 14 Instantaneous flow (low) 0-65535 read only 15 Set batch (high 2-bit) 0-65535 read and write 16 Set batch (low 4-bit) 0-65535 read and write 17 Remaining batch (high 2-bit) 0-65535 read only 18 Remaining batch (low 4-bit) 0-65535 read only 19 Accumulated flow (high 3-bit) 0-999 read only 20 Accumulated flow (low 4-bit) 0-9999 read only 21 Accumulated flow (1 decimal place) 0-9 read only 22 Weekly start (Sunday) 0,1 read and write 23 Weekly start (Monday) 0,1 read and write 24 Weekly start (Tuesday) 0,1 read and write 25 Weekly start (Wednesday) 0,1 read and write 26 Weekly start (Thursday) 0,1 read and write 27 Weekly start (Friday) 0,1 read and write 28 Weekly start (Saturday) 0,1 read and write 29 Sunday's start time (Hour) 0-23 read and write 30 Sunday's start time (Minute) 0-59 read and write 31 Sunday's start time (Second) 0-59 read and write 32 Monday's start time (Hour) 0-23 read and write 33 Monday's start time (Minute) 0-59 read and write 34 Monday's start time (Second) 0-59 read and write 35 Tuesday's start time (Hour) 0-23 read and write 36 Tuesday's start time (Minute) 0-59 read and write 37 Tuesday's start time (Second) 0-59 read and write 38 Wednesday's start time (Hour) 0-23 read and write 39 Wednesday's start time (Minute) 0-59 read and write 40 Wednesday's start time (Second) 0-59 read and write 41 Thursday's start time (Hour) 0-23 read and write 42 Thursday's start time (Minute) 0-59 read and write -! 15 of 19 pages-

43 Thursday's start time (Second) 0-59 read and write 44 Friday s start time (Hour) 0-23 read and write 45 Friday s start time (Minute) 0-59 read and write 46 Friday s start time (Second) 0-59 read and write 47 Saturday s start time (Hour) 0-23 read and write 48 Saturday s start time (Minute) 0-59 read and write 49 Saturday s start time (Second) 0-59 read and write 50 Interval of regeneration start time 1-9999 read and write 51 Steps of M program 1-16 read and write 52 Step width of 1st step 0-9999 read and write 53 Step width of 2nd step 0-9999 read and write 54 Step width of 3rd step 0-9999 read and write 55 Step width of 4th step 0-9999 read and write 56 Step width of 5th step 0-9999 read and write 57 Step width of 6th step 0-9999 read and write 58 Step width of 7th step 0-9999 read and write 59 Step width of 8th step 0-9999 read and write 60 Step width of 9th step 0-9999 read and write 61 Step width of 10th step 0-9999 read and write 62 Step width of 11th step 0-9999 read and write 63 Step width of 12th step 0-9999 read and write 64 Step width of 13th step 0-9999 read and write 65 Step width of 14th step 0-9999 read and write 66 Step width of 15th step 0-9999 read and write 67 Step width of 16th step 0-9999 read and write 68 S1 Step 1 (1 on, 0 off) 0-1 read and write 69 S1 Step 2 (1 on, 0 off) 0-1 read and write 70 S1 Step 3 (1 on, 0 off) 0-1 read and write 71 S1 Step 4 (1 on, 0 off) 0-1 read and write 72 S1 Step 5 (1 on, 0 off) 0-1 read and write 73 S1 Step 6 (1 on, 0 off) 0-1 read and write 74 S1 Step 7 (1 on, 0 off) 0-1 read and write -! 16 of 19 pages-

75 S1 Step 8 (1 on, 0 off) 0-1 read and write 76 S1 Step 9 (1 on, 0 off) 0-1 read and write 77 S1 Step 10 (1 on, 0 off) 0-1 read and write 78 S1 Step 11 (1 on, 0 off) 0-1 read and write 79 S1 Step 12 (1 on, 0 off) 0-1 read and write 80 S1 Step 13 (1 on, 0 off) 0-1 read and write 81 S1 Step 14 (1 on, 0 off) 0-1 read and write 82 S1 Step 15 (1 on, 0 off) 0-1 read and write 83 S1 Step 16 (1 on, 0 off) 0-1 read and write 84 The step for output in S2 1-16 read and write 85 Output delay time in S2 1-9999 read and write 86 S3 Step 1 (1 on, 0 off) 0-1 read and write 87 S3 Step 2 (1 on, 0 off) 0-1 read and write 88 S3 Step 3 (1 on, 0 off) 0-1 read and write 89 S3 Step 4 (1 on, 0 off) 0-1 read and write 90 S3 Step 5 (1 on, 0 off) 0-1 read and write 91 S3 Step 6 (1 on, 0 off) 0-1 read and write 92 S3 Step 7 (1 on, 0 off) 0-1 read and write 93 S3 Step 8 (1 on, 0 off) 0-1 read and write 94 S3 Step 9 (1 on, 0 off) 0-1 read and write 95 S3 Step 10 (1 on, 0 off) 0-1 read and write 96 S3 Step 11 (1 on, 0 off) 0-1 read and write 97 S3 Step 12 (1 on, 0 off) 0-1 read and write 98 S3 Step 13 (1 on, 0 off) 0-1 read and write 99 S3 Step 14 (1 on, 0 off) 0-1 read and write 100 S3 Step 15 (1 on, 0 off) 0-1 read and write 101 S3 Step 16 (1 on, 0 off) 0-1 read and write 102 Experimental operation (1 launch the experiment) 0-1 write 103 Experiment flag (1 in working) 0-1 read only 104 Experimental operation (1 next step) 1 write 105 Experimental operation (1 to Exit program) 1 write -! 17 of 19 pages-

106 Regeneration flag (1 in working) 1 read only 107 Forced regeneration (1 mandatory) 1 write 108 The number of steps for regeneration 1-16 read only 109 Remaining time in this step (Seconds) 0-9999 read only 7. Appendix 7.1 K value reference This table conforms to national PN10 and metric PVC pipe standard. Metric PVC Pipe Recommendatory K value DN40 DN50 DN65 DN80 DN100 6.8 10.0 3.6 4.2 2.8 3.3 1.8 2.2 0.8-1.2 Installation pattern Support base union connection Support base union connection Support base union connection Support base Flange connection Support base Flange connection * All K values in this table are for reference only. In case of discrepancy, the K value of test reference table for specific flow sensor shall prevail. 7.2 Control principle drawing -! 18 of 19 pages-