Samples Preparing the GC to run samples Running samples - Manual Injection Running samples - GC ALS or Valve Injection

Similar documents
Agilent 7890B Gas Chromatograph

11 Analytical Sequences

Agilent 7820A Gas Chromatograph

Agilent Intuvo 9000 Gas Chromatograph

Agilent G2070BA GC ChemStation

Agilent 7890GC. Firmware Bulletin. Revision B and A External use only

Agilent GC Drivers A

Agilent 7890 Series Gas Chromatograph

Agilent GC/MSD Instructions

SCN 848 Release Notes

Agilent Instrument Control Framework for Agilent LC/CE and GC instruments in Non-Agilent Chromatography Data Systems A.02.

Retention Time Locking Operation

FOCUS GC. Gas Chromatograph. Spare Parts Catalog

Warning 101 Invalid heater power for front detector, inlet, and aux 1 Warning 102 Invalid heater power for back detector, inlet, and aux 2

Agilent 7890GC. Firmware Bulletin. Revision B and A External use only

The minimum version of Microsoft's Internet Explorer is version If you need to upgrade, install version 6.0, service pack 1.

Agilent 7697A Headspace Sampler

Table of contents. Page

GRAPHPACK 2M ferrule. The GRAPHPACK 2M ferrule is a cylindrical metal cartridge packed with graphite.

The Agilent 5975 inert MSD: New Tools for the Forensic Analyst

Agilent 7890B Gas Chromatograph

Agilent SimDis System

Agilent MassHunter Workstation Software 7200 Accurate-Mass Quadrupole Time of Flight GC/MS

GC-MS ChemStation Reference Guide. Last Updated July 2014

EZChrom Elite Supported Modules and Firmware Updated 8/12/2009

6820 GC (G1176A & G1180A) RS-232/TCP/IP

Getting low-resolution GC-MS data on the JEOL GCMate Introduction

Agilent GC, MS, and ALS

A. About this Manual

Agilent 7890 GC Instrument Control Software Version 2.5

Agilent G1701DA MSD ChemStation

Agilent ICF Support v3.0

5975 inert MSD. Chris Sandy European GC-MS Product Specialist Agilent Technologies

Data Acquisition with 3800 GC Control

True Blue Performance

Manual HPLC-4 Alliance-UV

Instrument Network (INET) or Local Area Network (LAN) Communications Interface Board Installation Guide

MICRO GC FUSION Micro GC Fusion 3/17/2014 1

Agilent G1732AA MSD Security ChemStation

Agilent MassHunter GCMS Data Acquisition for the 5977 Series MSD System

Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes. System Information. Agilent Technologies

Detailed procedures, operation instructions, maintenance, and emergency contact information list is attached.

Technical Support Information No January Complementary Service Information for MicroSAM Part 4

Agilent Instrument Control Framework A for Agilent LC/CE and GC Instruments in Non-Agilent Chromatography Data Systems Release Notes

How to Run the CASPiE GCMS

HITACHI LACHROM ELITE

Process Gas Chromatograph

IONSCAN -LS. Quick Start Guide. Revision A, April 2005 Part Number USA

Operating Manual. High Performance Liquid Chromatograph. Scientific Equipment Center, Prince Of Songkla University

To NeSSi or Not to NeSSi: A Fast and Micro GC Experience Review

5973 Network Mass Selective Detectors

MassLynx TM 4.1 SCN 916 Release Notes

CryoFocus-4 GC Cryogenic Trap

UniPoint System Software User s Guide

Agilent OpenLAB Chromatography Data System

Process Gas Chromatograph PGC5000 Series. PGC5000A Master Controller Designed for Reliability and Simplicity

Agilent 1100 HPLC ChemStation 1) Turn on all the modules for HPLC system (CapPump G1376A, DAD G1315B) and allow for system to initialize.

ABB Analytical ABB Process Analytics. VistaII. Model 2000 Process Gas Chromatograph

Fatty Acid Methyl Ester (FAME) RTL Databases for GC and GC/MS

3 Starting the chiral HPLC and logging into LC Real Time Analysis.

Data Acquisition with 3400/3600 GC Control

Chemical Analysis Group Gas Chromatograph Common Cabling \ Pin-outs Document A15707

Introduction to the HPLC ChemStation and Acquisition

Soprane II Documentation

When Quality Counts. Valve Gate Control Installation and Setup. RJG, Inc Valve Gate Control. July 9, 2013 Rev 5.3

FROG-4000TM Quick Start Guide

Customers should provide all necessary operating supplies upon request of the engineer.

1100/1200 Series Injector Programming

Precision Instruments for Research and Industry. J-KEM Scientific Syringe Pump

Isolera. User Manual

DFS High Resolution GC/MS High Performance Magnetic Sector GC/MS

Peak Performer 1 PDHID User Manual

MOVING FROM PIPELINE TO PROCESS APPLICATIONS

Quick Setup Instructions for the Knauer HPLC-System. Quick Setup Instructions for the Knauer HPLC-System For windows XP (using CHANCE vers. 2.

Chromeleon software orientation

Using the Chromeleon Summit 2 Tandem Operation Wizard

HT3X00A. Clarity Control Module. Code/Rev.: M153/50E Date: 11/13/2018. Fax: Petrzilkova 2583/ Prague 5

Agilent G1732AA MSD Security ChemStation

Agilent OpenLAB Chromatography Data System (CDS)

Agilent SP in-1 GC/MSD DRS Analyzer

9 Maintenance and Repair

Getting Started. Environmental Analysis Software

CTC Sampler Implementation in the GC/MSD ChemStation. Technical Overview. Introduction

Operation of the Kratos Profile Mass Spectrometers Table of Contents

Data Acquisition with CP-2002/2003 Micro-GC Control

EZ-ZONE CONTROLLERS. Profile Programming Guide. SHEL LAB Ovens

Retention Time Locking with the MSD Productivity ChemStation. Technical Overview. Introduction. When Should I Lock My Methods?

700XA Process Gas Chromatograph

Waters 600E Multisolvent Delivery System Quick Start Guide

Dryer. M720 Programming and Operation Manual. July 15, 2015 Revision 1.51

Process Gas Chromatograph

Peak Performer 1 PDHID (930- Series) User Manual

Micro GC Fusion Quick Start Guide

Agilent G1732BA MSD Security ChemStation

Agilent Instrument Control Framework (ICF) Update A Driver Update 1 (DU1) Hot Fix 2 (HF2)

VERSION RELEASE NOTES... 2 VERSION RELEASE NOTES... 3 VERSION RELEASE NOTES... 5

QUICKSTART GUIDE. Infrared Gas Analyzer. Teledyne Analytical Instruments

Guidebook for Installation and Familiarization. HP 1100 Series Combinatorial Chemistry Analysis System

Agilent 3396 Series III Integrator

Sniffer 9100 Series. GC-O GC/MS-O, State of the art... GC-Olfactometry Method for Food, Flavor and Fragrances. Principle

Transcription:

27 Samples Preparing the GC to run samples Running samples - Manual Injection Running samples - GC ALS or Valve Injection Methods Creating Methods Setting a Column Flow Rate or Pressure Sequences Creating sequences Procedure: Modifying a previously stored sequence Start/Stop/Pause a sequence Maintenance Changing the Column Checking Performance Shutting down the GC 657

Samples Samples Preparing the GC to run samples Preparing the GC to run samples 1. Check gas supplies and source pressures. 2. Check the power supply. Restore power if interrupted. 3. Turn on the GC, computer, and communication systems. 4. Check the identity of the installed column(s). 5. If needed, change the column. See Changing the Column. 6. Check the availability of the samples to be analyzed. 7. Confirm what sequences and methods are required. Running samples - Manual Injection 1. Prepare the GC. See Preparing the GC to run samples. 2. Prepare sample(s) for injection. 3. Load the desired method. Press [Load] [Method], then input the desired method number and press [Enter]. See Procedure: Loading a previously stored method. 4. Wait for the Ready prompt. 5. Load the syringe. 6. Simultaneously inject the sample and press [Start]. The run light will come on and stay on until the run is completed. 658

Samples Running samples - GC ALS or Valve Injection Running samples - GC ALS or Valve Injection 1. Prepare the GC. See Preparing the GC to run samples. 2. Prepare sample(s) for injection. 3. Load sample vials into the ALS tray or turret, if GC ALS is used. Remember the turret or tray position of each sample vial. To edit injector setpoints, see Procedure: Editing injector setpoints. To configure the injector, see Configuring the injector. To edit the sample tray setpoints, see Procedure: Editing the sample tray setpoints. To configure the bar code reader, see Procedure: Configuring the bar code reader. 4. Load the desired sequence. Press [Load] [Sequence]. Input the sequence number and press [Enter]. To create a sequence, see Creating sequences. To create a sampler subsequence, see Procedure: Creating a sampler subsequence. To create a valve subsequence, see Procedure: Creating a valve subsequence. To modify a sequence, see Procedure: Modifying a previously stored sequence. 5. Start the sequence. Press [Seq control]. Scroll to Start sequence. Press [Enter]. The Run light will come on and stay on until the sequence is completed. 659

Methods Methods Creating Methods Creating Methods For more information, see Analytical Methods. 1. Set the oven parameters. Press [Oven], and scroll down. To create an isothermal run, see Procedure: Setting up an isothermal run. To create a single-ramp program, see Procedure: Setting up a singleramp program. To create an oven program with up to six ramps, see Procedure: Setting up a multiple-ramp program. 2. Set your column parameters. Press [Col 1] or [Col 2] and enter: a. The column length and diameter (capillary columns). See Procedure: Configuring a capillary column. b. A column mode, if available. See Procedure: Selecting a column mode. c. The column head pressure or column flow. See Procedure: Configuring a capillary column, Procedure: Selecting a column mode, or Procedure: Setting initial flow or pressure or average linear velocity. 3. Set the inlet parameters. Press [Front Inlet] or [Back Inlet]. Select inlet mode, if available. Enter parameters. For example, set the temperature, pressure, split ratio, split flow, and total flow. See Using a Split/Splitless Inlet, Using a Purged Packed Inlet, Using a Cool On-Column Inlet, Introducing the Agilent PTV, or Using a Volatiles Interface. 4. Set the detector parameters. Press [Front Det] or [Back Det]. Enter parameters. For example, set temperature, hydrogen flow, air flow, makeup gas and flow. See Operating with EPC, Operating the TCD, 660

Operating with EPC, Procedure: Operating the µ-ecd, or Operating the FPD. 5. Save these parameters as a method. Press [Store] [Method]. Input a method number (1 through 9), then press [Enter]. Setting a Column Flow Rate or Pressure 1. Set the new value in the column control table. See Procedure: Setting initial flow or pressure or average linear velocity. 2. To save the change, press [Store] [Method]. Input a method number (1 through 9), and press [Enter]. 661

Sequences Sequences Creating sequences Creating sequences To create a sequence 1. Press [Seq] to open the sequence control table. Title line this title will change depending on where the cursor is placed within the control table Priority sequence Subsequences Post-sequence events Figure 92 Example sequence table 662

Sequences Creating sequences 2. Scroll to SEQUENCE (Priority). Use the priority sequence (set it to On) only if you want to interrupt a running sequence to run urgent samples now. Otherwise set it to Off. See Priority sequence. 3. Scroll to Subseq 1. Set the sequence type (sampler or valve) using the [Mode/Type] key. Define the samples to be run, where they are located, and what method to use for them. For details about creating a sampler subsequence, see Procedure: Creating a sampler subsequence. For details about creating a valve subsequence, see Procedure: Creating a valve subsequence. For general information about sequences, see Analytical Sequences. 4. Create additional subsequences as needed. Create a subsequence for each set of valve or automatic liquid sampler samples you wish to run with a given method. Create a subsequence for each set of samples that require a different method. You can create up to five subsequences. 5. Set any desired post sequence events. Scroll to SEQUENCE (Post Seq). Input the Post Sequence method number. Enter 0 to not load a method. To repeat the sequence indefinitely, turn Repeat Sequence On. See Post Sequence or Procedure: Setting the Post Sequence events for more information. 6. Store the completed sequence. See Procedure: Storing a sequence. For more information, see Analytical Sequences. 663

Sequences Start/Stop/Pause a sequence Start/Stop/Pause a sequence To control a sequence, access the Sequence control table by pressing [Seq Control]. What do you want to do? Start a sequence Stop a sequence after the current run Pause a sequence Run a priority sample now, then continue the sequence Abort the run and sequence immediately See Procedure: Starting/running a sequence Procedure: Stopping a sequence Procedure: Pausing and resuming a sequence Priority sequence Press the [Stop] key to immediately halt the current run and the sequence. See Aborting a sequence for more details. 664

Maintenance Maintenance Changing the Column Changing the Column To change a column: 1. Select the appropriate fittings and adapters for your: Capillary columns, see Ferrules for capillary columns. Packed metal columns, see Fittings and Ferrules for packed metal columns. Packed glass columns, see Ferrules and O-rings for glass packed columns. 2. Prepare your column. If using a capillary column, see Procedure: Preparing capillary columns. If using a packed metal column, see Preparing packed metal columns. 3. Lower the temperatures of the oven, inlet, and detector to <40 o C. 4. Check the liner. Be sure you have the correct liner (or other inlet hardware) installed. For instructions on choosing and installing liners, see Liners. Inlet Split/splitless Purged packed Cool on-column Programmed temperature vaporization Refer To Liners Liners and inserts Hardware Inlet adapters 665

Maintenance Changing the Column 5. Install the column. Column Type Inlet or Detector Refer To Capillary Split/splitless inlet in the split/splitless inlet Cool on-column inlet Purged packed inlet Programmed temperature vaporization inlet and Volatiles interface FID NPD TCD µ-ecd FPD in the cool on-column inlet in the purged packed inlet in the PTV inlet and Volatiles Interface in NPD and FID detectors in the TCD in the µ-ecd in the FPD Packed Metal Any Procedure: Installing an adapter in a detector fitting and Procedure: Installing packed metal columns Packed Glass Any Procedure: Installing glass packed columns 6. Condition your column, if needed. See Conditioning columns. 7. If using a capillary column, configure (define) it if desired. See Procedure: Configuring a capillary column. Now may be a good time to check your inlet septum and change it if needed. 666

Maintenance Checking Performance Checking Performance To check the performance of your GC, run the recommended sample mixture for your detector type as described below. 1. Install the checkout column. For the FID, TCD, NPD, µ-ecd, and FPD, use an HP-5, 30 m x 0.32 mm x 0.25 µm capillary column (part number 19091J-413). 2. Install the appropriate liner or insert, if needed: Inlet Item Split/splitless Liner, part no. 5062-3587 (splitless) Purged packed Liner, part no. 5181-3382 (deactivated) Cool on-column Insert, part no.19245-20525 Programmed temperature vaporization Baffled liner, part no. 5183-2037 320 µm adapter part no. 5182-9761 3. Set the checkout conditions on your GC. Detector Type: FID TCD NPD µ-ecd FPD Refer to: FID checkout conditions TCD checkout conditions NPD checkout conditions µ-ecd checkout conditions FPD checkout conditions 4. Prepare your sample(s). 5. When the GC is ready, make the injection and start the run. If using manual injection, see Running samples - Manual Injection. If using sampler injection, see Running samples - GC ALS or Valve Injection. 667

Maintenance Checking Performance 6. Compare your result against the appropriate reference chromatogram: Detector Type: FID TCD NPD µ-ecd FPD Refer to: Typical FID checkout chromatogram Typical TCD checkout chromatogram Typical NPD checkout chromatogram Typical µ-ecd checkout chromatogram Typical FPD checkout chromatograms Remember that the reference chromatogram is typical and is only intended to serve as a guide. 668