Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

Similar documents
Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

ABB i-bus KNX Binary Inputs BE/S Product Manual

PRODUCT MANUAL. ABB i-bus KNX SV/S KNX-Power Supplies

Intrusion Detection Technology SafeKey Switching Module SSM/A, SSM/U Product Manual

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

ABB i-bus KNX Application Unit Time ABZ/S 2.1 Product Manual

ABB i-bus KNX AC/S Application Controller

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

ABB i-bus KNX IP Router, MDRC IPR/S 3.1.1, 2CDG110175R0011

ABB i-bus KNX Blower/Fan Coil-Actuator LFA/S 1.1, LFA/S 2.1. Product Manual. Intelligent Installation Systems ABB

ABB i-bus EIB / KNX Blower/Fan Coil-Aktuator LFA/S 1.1, LFA/S 2.1. Product Manual. Intelligent Installation Systems ABB

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

ABB i-bus KNX Logic Controller ABA/S 1.2.1, 2CDG110192R0011

ABB i-bus KNX HCC/S Heating/cooling circuit controller

ABB i-bus KNX BCI/S Boiler/Chiller Interface

ABB i-bus KNX Blind/Roller Shutter Actuator JRA/S Product Manual

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

ABB i-bus KNX Fan Coil Actuator FCA/S 1.1M Product Manual

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating voltage Maximum

ABB i-bus KNX Weather Unit, 1-fold, MDRC WZ/S , 2CDG110184R0011

ABB i-bus KNX Blind/Roller Shutter Actuators JRA/S Product Manual

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

ABB i-bus KNX DALI Gateway Emergency Lighting DGN/S Product Manual

ABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011

Operating instructions. Speed monitor D / / 2014

252F 5WG FB_1 DELTA

CMC III Temperature/Humidity Sensor

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

CMC III Universal Sensor

ABB i-bus KNX SUG/U 1.1 Split Unit Gateway Product Manual

ABB i-bus KNX Blower Actuator FCL/S x Product Manual

Product Manual. Application Unit Logic

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Power supply CP-D 12/2.1 Primary switch mode power supply

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Operating instructions Evaluation system for flow sensors VS / / 2013

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

RTU500 series Data Sheet Power Supply CP-E 24/2.5

ABB i-bus KNX Thermoelectric Valve Drive, 230 V TSA/K 230.2, 2CDG R0011

Product and Function Description

Redundancy unit CP-A RU

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Power supply CP-E 48/1.25 Primary switch mode power supply

Air Quality Sensor KNX AQS

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

584 5WG AB_1 DELTA

Power supply CP-E 24/0.75 Primary switch mode power supply

Operating instructions. Standstill monitor A / / 2011

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power supply CP-E 24/10.0 Primary switch mode power supply

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

ABB i-bus KNX KNX/EnOcean Gateway EG/A , 2CDG R0011

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

PI-EX-ME-2NAM/COC-24VDC

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

TRIO-DIODE/12-24DC/2X10/1X20

PHOENIX CONTACT - 05/2007

Weather station AP 257/51

Overview of types. Technical data

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

PHOENIX CONTACT - 12/2007

Weather station GPS AP 257/61 Weather station AP 257/51

Push button UP 287, 4 - fold

PI-EX-ME-2NAM/COC-120VAC

QUINT-BUFFER/24DC/24DC/40

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

RТTH DUAL ROOM SWITCH

Operating and mounting instructions

MDM 011-Z1 Regen Resistor

KNX USB INTERFACE UIMtp

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

Display Panel BAT 100 LSN. en Operation Guide

Messaging module CP-C MM

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

KNX T-UP. Temperature Sensor. Technical specifications and installation instructions

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Product Manual V ABB i-bus EIB / KNX DALI-Gateway DG/S 1.1. Intelligent Installation Systems ABB

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Power supply CP-C 24/5.0

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power consumption In operation At rest For wire sizing

Technical data sheet. Technical data

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

PHOENIX CONTACT - 07/2006

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

Products no longer available

Transcription:

2 2.1 Air Quality Sensor LGS/A 1.1 The ABB i-bus KNX Air Quality Sensor 1.1 is a combined sensor for CO 2, temperature and humidity measurement (relative humidity). Three independent thresholds can be set for the CO 2 concentration and the relative humidity in addition to a threshold for the temperature. Exceeding or under-running the thresholds can trigger an action. A separate communication object Lock threshold x CO2 (x = 1, 2 or 3) is available for every threshold. Measured values can be transmitted directly on the bus. The communication object Ventilation can be used for speed control or as a position indicator for ventilation flaps. LGS/A 1.1 The parameterization is undertaken via the ETS. The connection to the KNX is established using the bus connection terminals on the interior of the device. 2.1.1 Technical data Supply Bus voltage 21 30 V DC Current consumption via bus < 12 ma CO 2 Measuring range 300 9,999 ppm Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm ± 120 ppm of actual measured value ± 250 ppm of actual measured value ± 300 ppm of actual measured value Humidity Measuring range 1 100 % Accuracy ± 5 % of actual measured value Temperature Measuring range 0 40 C Connections Operating and display elements Accuracy KNX Button/LED Programming in the device interior LED ± 2 % of actual measured value solid for assignment of the physical address Four-colour (green, yellow, orange, red, depending on the parameterization) to indicate the CO 2 concentration LED (relative humidity) Four-colour (yellow, green, red, blue, depending on the parameterization) to indicate the relative humidity Enclosure IP 20 To EN 60 529 Safety class IIl To EN 60 730-1 Isolation category Overvoltage category III to EN 60 664-1 Pollution degree 2 to EN 60 664-1 2010 ABB STOTZ-KONTAKT GmbH 7

KNX safety extra low voltage Temperature range SELV 24 V DC Operation Storage Transport -5 C +45 C -10 C +60 C -10 C +60 C Ambient conditions Maximum air humidity 93 %, no condensation allowed Design Device for wall mounting Dimensions 74 x 74 x 28 mm (H x W x D) Weight in kg 0.1 Mounting Surface Mounting (SM), screw mounted To EN 60 715 Mounting position As required Housing/colour Plastic, white (similar to RAL 9010) Approvals KNX to EN 50 090-1, -2 Registered CE mark In accordance with the EMC guideline and low voltage guideline Device designation Application program Maximum number of communication objects Maximum number of group addresses Maximum number of associations LGS/A 1.1 CO2, rel. humidity and temperature/1.1 27 128 128 Note ETS from version ETS3.0f or higher is required for programming. A *.VD3 or higher type file must be imported. The application program is available in the ETS3 at ABB/Heating, Ventilation, Air conditioning/air Quality Sensor. The device does not support the closing function of a KNX device in the ETS. If you inhibit access to all devices of the project with a BCU code, it has no effect on this device. Reading out data and programming is still possible. Danger The Air Quality Sensor is not suitable for safety-relevant gas measurements! Important Safeguard the device against falling. Vibrations can damage the sensor. Damage to the sensor can lead to incorrect measurement results. 2010 ABB STOTZ-KONTAKT GmbH 8

2.1.2 Circuit diagram 1 Label carrier 2 Button Programming 3 LED Programming 4 Bus connection terminal 5 Housing upper section 6 Housing lower section 7 LED (four-colour, CO 2 concentration) 8 LED (four-colour, relative humidity) 2010 ABB STOTZ-KONTAKT GmbH 9

2.1.3 Dimension drawing 2010 ABB STOTZ-KONTAKT GmbH 10

2.2 Assembly and installation The ABB i-bus KNX Air Quality Sensor is a wall mounted device. The device should be protected against draughts and heat irradiation as otherwise the measured data will be falsified. Do not mount on soft surfaces as otherwise an exchange of air will not occur. The connection to the bus is implemented via a bus connection terminal inside the device, refer to Connection to the KNX, page 13. The device is ready for operation after connection to the bus voltage. Accessibility to the device for the purpose of operation, testing, visual inspection, maintenance and repair must be provided compliant to VDE 0100-520. Commissioning requirements In order to commission the device, a PC with ETS and an interface, e.g. USB or IP, to the ABB i-bus are required. The device is ready for operation after connection to the bus voltage. The installation and commissioning may only be carried out by qualified electrical specialists. The appropriate norms, guidelines, regulations and specifications should be observed when planning and setting up electrical installations. Protect the device from damp, dirt and damage during transport, storage and operation. Only operate the device within the specified technical data limits! Protect the device from dirt and damage. The voltage supply to the device must be switched off before mounting work is performed! Supplied state The device is supplied with the physical address 15.15.255. The application program is pre-installed. It is therefore only necessary to load group addresses and parameters during commissioning. However, the complete application program can be reloaded if required. The entire application program is loaded after a change of the application program, after a discontinued download or after discharge of the device. The process takes significantly longer than loading parameters and group addresses. Download behaviour Depending on the PC, which is used, the progress bar for the download may take up to one and a half minutes before it appears due to the complexity of the device. 2010 ABB STOTZ-KONTAKT GmbH 11

Assignment of the physical address The assignment and programming of the physical address is carried out in the ETS. The device features a button Programming for assignment of the physical device address. The red LED Programming lights up after the button has been pushed. It switches off as soon as the ETS has assigned the physical address or the button Programming is pressed again, refer to Programming of the physical address, page 14. Cleaning If devices become dirty, they can be cleaned using a dry cloth. Should a dry cloth not remove the dirt, the device can be cleaned using a slightly damp cloth and soap solution. Corrosive agents or solutions should never be used. Maintenance The device is maintenance-free. No repairs should be carried out by unauthorised personnel if damage occurs, e.g. during transport and/or storage. 2010 ABB STOTZ-KONTAKT GmbH 12

2.2.1 Opening the device The device must be opened to connect it to the KNX. Connection to the KNX Open the housing cover with a screwdriver on one of the four side latching lobes. Feed the bus cable through the bottom of the opening and into the bus terminal (1). Ensure correct polarity! Close the housing cover. 1 Sensor membrane 2 Button Programming 3 LED Programming 4 Bus terminal connection Caution Do not touch the sensor membrane (1) during mounting! It could cause incorrect measured value detection. A section of the PCB beside the bus connection terminal is covered with cardboard for isolation purposes. This cardboard may not be removed. Failure to observe this instruction can cause damage to the device due to electrostatic discharge during installation. 2010 ABB STOTZ-KONTAKT GmbH 13

Programming of the physical address The Programming button is located on the LGS/A 1.1 in the interior of the device (2). To press the Programming button, push a screwdriver through the opening on the lower section of the device. The red LED Programming LED lights up. This is also easily recognizable with a closed upper housing section. 2010 ABB STOTZ-KONTAKT GmbH 14

2.3 Display elements Two indicator LEDs are located on the front of the Air Quality Sensor: Four colours are displayed on each indicating the quality of the room air as determined by the parameterized thresholds: Measured value LED CO 2 concentration LED Room state Humidity Below threshold 1 Green Low Yellow Humidify Between thresholds 1 and 2 Yellow Medium Green Humidity OK Between thresholds 2 and 3 Orange High Red Dehumidify Below threshold 3 Red Very high Blue Condensation alarm 2010 ABB STOTZ-KONTAKT GmbH 15