Published by and copyright 2015 Siemens AG Energy Management Freyeslebenstr Erlangen, Germany

Similar documents
VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

VCL-TP, Teleprotection Equipment

The power line carrier solution for digital transmission grids siemens.com/powerlink-ip

FL MC 2000E (SM40) LC

VCL-TP, Teleprotection Equipment with Trip Counter Display

SWT 3000 Teleprotection siemens.com

SIPROTEC easy 7SJ45 Numerical Overcurrent Protection Relay Powered by CTs

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

Technical Data TICRO 100

TM3AI4 module TM3-4 analog inputs

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Bus Bar Protection Relay B-PRO 4000

Relion 611 series. 611 series Type Test Certificate

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

TM3TM3 module TM3-2 temperature inputs and 1 analog output

TM3TI4 module TM3-4 inputs temperature

RT4B-110V/12A RECTIFIER

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Connection Master. Datasheet. siemens.com

TM221CE40R controller M IO relay Ethernet

TM221M16R controller M IO relay

TM3TI8T module TM3-8 inputs temperature

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

RT4F-110V/25A RECTIFIER

TF501, TF521 Terminal Bases

RT4F-120V/20A-WAC RECTIFIER

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

TM221CE24R controller M IO relay Ethernet

Ha-VIS econ 2000 Fast and Full Gigabit Ethernet Basic. Features

TM3TI4 module TM3-4 inputs temperature

Features and Benefits. Certifications

TM200CE24T controller M IO transistor Source+ Ethernet

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

TM241C40U controller M IO transistor NPN

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

TU531, TU532 Terminal Unit

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

TM241C24T controller M IO transistor PNP

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

TM221M16TG controller M IO transistor PNP spring

RT4F-48V/50A-WAC RECTIFIER

TM221CE40T controller M IO transistor PNP Ethernet

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

TM200C24R controller M IO relay

LMC058LF42 compact base - 42 I/O - 24 V DC supply

TM241CE24T controller M IO transistor PNP Ethernet

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

TM221CE24T controller M IO transistor PNP Ethernet

SEL-2730M 24-Port Managed Ethernet Switch

TM221ME32TK controller M IO transistor PNP Ethernet

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

AI531 Analog Input Module

TM221M32TK controller M IO transistor PNP

TM221ME16T controller M IO transistor PNP Ethernet

TM221CE40R controller M IO relay Ethernet

RuggedMC RMC RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. Ethernet Media Converter (Copper to Fiber) Universal Power Supply Options

TM3DI16 module TM3-16 inputs

HMISCU6A5 3 5 color touch controller panel - Dig 16 inputs/10 outputs

TM241C40R controller M IO relay

Rugged MediaConverter

Type VRLTC tap changer

HMISCU8A5 5 7 color touch controller panel - Dig 16 inputs/10 outputs

LineMaster 100. Continuous-line Recorder. ABB Instrumentation 10/ EN

TM241CE24U controller M IO transistor NPN Ethernet

CM597 Ethernet Communication Module

General information. Display. Supply voltage

PHOENIX CONTACT - 10/2009

TM241CE40R controller M IO relay Ethernet

General information. Display. Supply voltage. Input current. Encoder supply. Output current

AO523 Analog Input Module

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

Binary output and supervision 520CSD01 Data sheet

TM258LF42DT compact base M I/O - 24 V DC - CANopen

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

TM251MESE. Main. [Us] rated supply voltage. 14 with remote I/O architecture W with max number of I/O expansion module

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RuggedMC RMC40 RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. 4-Port Ethernet Media and Speed Converter

TM241CE24T controller M IO transistor PNP Ethernet

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

AX522 Analog Input/Output Module

PHOENIX CONTACT - 11/2008

TM241CE40T controller M IO transistor PNP Ethernet

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS

General information. Display. Supply voltage. Input current

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

HMISCU6B5. Main. 60 right 40 top 60 bottom

Arc protection relay. Features Three-phase overcurrent function. Application

General information. Display. Supply voltage. Input current. Encoder supply. Output current

TM251MESC controller M251 Ethernet CAN

General information. Display. Supply voltage

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

TM241CE40R controller M IO relay Ethernet

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

TM3DI16G module TM3-16 inputs spring

Scout-S Station Controller

General information. Display. Supply voltage. Input current

Transcription:

Published by and copyright 2015 Siemens AG Energy Management Freyeslebenstr. 1 91058 Erlangen, Germany For more information, please contact our Customer Support Center Phone: +49 180/524 84 37 Fax: +49 180/524 24 71 (Charges depending on provider) E-mail: support.ic@siemens.com Article No.: EMDG-B10011-00-4A00 Printed in Germany Dispo No. 6200 GB 150516 WS 08150.0 Printed on elementary chlorine-free bleached paper. All rights reserved. Trademarks mentioned in this document are the property of Siemens AG, its affiliates, or their respective owners. Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should therefore be specified in the contract.

Power network telecommunication SWT 3000 Teleprotection technical data siemens.com

Sustainable success for high-voltage power networks The SWT 3000 Teleprotection system has been the first choice for reliable high-voltage networks for 50 years. The technology is refined on an ongoing basis to offer a high level of system stability and reliable signal transmission. Errors can not only be detected but isolated extremely fast. The SWT 3000 is known for its high degree of versatility, so it can be used in many different ways in analog and digital networks. In addition, it allows gradual changeover of existing substations to the IEC 61850 communication standard. Operators can enter the new network era step by step in line with their strategic objectives and available budgets. Power companies also have many options when it comes to transmission paths. Whether operators want to connect two SWT 3000 devices directly via analog interfaces or Power Line Carrier (PLC), whether the transmission should run via digital PDH, SDH or IP networks, whether different types of fiber-optic connections will be used, or whether SWT 3000 will be completely integrated into a PLC connection: Nearly anything is possible. The existing infrastructure is the decisive factor, and SWT 3000 accommodates its requirements flexibly, affordably, and without breaking the budget. 2

Commands Nominal input/threshold Command interface Number of commands Analog transmission Digital transmission IEC 61850 command input/output EN 100 1) Electrical interface Optical interface Binary command input IFC-P/IFC-D Up to 4 Up to 8 RJ45; 100 Base-T; max. range 20 m 1,310 nm; LC connector; max. range 1.5 km Input voltage range 24 V 250 V DC (tolerance 20% to +20%) Inputs per module 4 24 V 48/60 V 110 V 250 V Polarity Pulse suppression Input current Binary command output IFC-P for normal contact load Contacts per module 4 Switching current Switching current < 2.5 ms Continuous current Insulation withstand voltage Binary command output IFC-D for high contact load Contacts per module 4 Switching current Continuous current Insulation withstand voltage Binary command output IFC-S for signaling Contacts per module 8 Switching current Continuous current Insulation withstand voltage Low level Uin < 15 V; high level Uin > 18 V Low level Uin < 40 V; high level Uin > 47 V Low level Uin < 72 V; high level Uin > 85 V Low level Uin < 167 V; high level Uin > 198 V Independent 1 ms to 100 ms; programmable in 1-ms steps Max. 2 ma Relay NO; normal open 250 W/250 VA 250 V AC/DC 1.5 A AC/DC 5 A AC/DC 1.5 A AC/DC Relay NO; normal open 150 W/1250 VA 250 V AC/DC 5 A AC/DC (30 A 0.5 ms) 5 A AC/DC Relay CO; changeover with common root 150 W/1,250 VA 250 V AC/DC 5 A AC/DC (30 A 0.5 ms) 1 A AC/DC 1) Not applicable in combination with Ethernet line interface 3

Transmission line digital networks Digital interface DLE 64 Kbps X.21; G703.1 2 Mbps G703.6 sym. 120 Ω; G703.6 asym. 75 Ω Path protection (1+1) Digital Ethernet interface EN100 5) ETH electrical ETH optical Path protection (1+1) Digital and digital line Digital and FO line Digital and analog line Digital and Ethernet line Ethernet and analog line 100TX/100 Base-T; two RJ45 ports; max. range 20 m 100FX/100 Base-FX; two ports; LC connector; SFP transceiver 1,310 nm; max. range 1.5 km Ethernet and analog line Ethernet and digital line Transmission time 1) 2 Mbps t₀ 3 ms 64 kbps t₀ 5 ms Security and dependability Security PUC < 10-8 Dependability PMC < 10-4 at BER of 10-6 Optical budget Range Optical budget Range Optical budget Range Transmission line fiber optics Fiber-optic interface FOM Data rate Optical module Connector Path protection (1+1) Long-range single-mode FOL1 Wavelength Short-range single-mode FOS1 Wavelength to PowerLink to PowerLink Short-range multimode FOS2 Wavelength to PowerLink to PowerLink 64 Kbps and 2 Mbps for direct connection N = 1 to 12 x 64 kbps acc. to IEEE C37.94 for connection to multiplexer SFP transceiver single-mode; multimode LC FO line and digital FO and FO line FO and analog line FO and Ethernet line 1,550 nm 43 db 33 db 154 km 2) 118 km 2) 1,310 nm 33 db 17 db 13 db 87 km 3) 45 km 3) 34 km 3) 850 nm 7 db 7 db 7 db 2 km 4) 2 km 4) 2 km 4) 4

Short-range multimode FOS3 Wavelength 830 nm Optical budget for C37.94 7 db Alarm output Mechanical design Range for C37.94 2 km Fiber-optic box interface FOB Input voltage Power consumption Continuous current Dimensions Mounting 20 V to 72 V DC/22 V to 60 V AC Max. 3.5 W Changeover contact 150 W/300 VA 200 V DC/140 V AC 5 A AC/DC 230 mm x 110 mm x 60 mm DIN rail Insulation withstand voltage Alarm outputs Digital I/O G703.6 Fiber-optic modules (SFP transceiver) 500 V AC Optical budget and range are identical to FOL1; FOS1; FOS2 as specified for FOM Transmission line analog networks Broadband modulation Analog interface CLE Modulation type Trip frequencies Guard Narrowband modulation Channel 1 Channel 2 Channel 3 Channel 4 Voice frequency interface Transmitter Receiver Path protection (1+1) F6 frequency shift keying or CT-coded tripping 0.3 to 2.03 khz 2.61 or 3.81 khz 0.63 to 1.26 khz 1.64 to 2.27 khz 2.65 to 3.28 khz 3.16 to 3.79 khz Level max. +15 dbm Impedance 600 Ω Level range 40 db to +4 db Impedance 600 Ω or 5 kω Analog and digital line Analog and FO line Analog and Ethernet line Broadband modulation Transmission time SWT 3000 stand-alone 1) Single-purpose Alternate multipurpose (voice) Narrowband modulation t₀ 10 ms (F6, CT) t₀ 15 ms (F6, CT) t₀ 15 ms (F6) Broadband modulation Transmission time SWT 3000 integrated into PowerLink 1) Single-purpose Alternate multipurpose Alternate multipurpose Simultaneous multipurpose Narrowband modulation Security and dependability t₀ 10 ms (F6, CT) t₀ 15 ms (F6, CT); F2+AMP t₀ 19 ms (F6, CT); DP+AMP t₀ 10 ms (F6, CT) t₀ 15 ms (F6) Security direct tripping PUC < 10-6 Dependability direct tripping PMC < 10-4 at SNR of 6 db Security blocking/permissive tripping PUC < 10-4 Dependability blocking/permissive tripping PMC < 10-3 at SNR of 6 db 1) Values are given for the IFC-P module and permissive tripping. If the IFC-D module is used for increased contact load, all specified signal transmission times are prolonged by about 4 ms. For direct tripping schemes the transmission time increases about 5 ms. Ethernet line interface will prolong the digital transmission time about 2ms. 2) Assumed fiber attenuation 0.28 db/km 3) Assumed fiber attenuation 0.38 db/km 4) Assumed fiber attenuation 3.5 db/km 5) Not applicable in combination with IEC 61850 command interface 5

132 57.15 132 37.4 Common system data Input voltage 24 V to 60 V DC ( 20% to + 20%) or 110/220/250 V DC ( 20% to +20%) and 115/230 V AC ( 20% to +10%); 47 Hz to 63 Hz Power consumption Alarm output ALR Contacts per module 3 Carry current Binary input Nominal voltage BI1/ BI2 Polarity Clock synchronization input Sync pulse IRIG-B Ethernet Nominal voltage binary input Nominal voltage IRIG-B Event recorder Events Trip counter Element manager Approx. 30 W/VA Relay CO; changeover 300 W/1,000 VA 250 V AC/DC 5 A AC/DC 24 V to 250 V DC, tolerance 20% to +20% Independent Minutes/hour B00x, B000, B004 NTP 24 V to 250 V DC, tolerance 20% to +20% 5 V/12 V/24 V DC 8,000; nonvolatile; 1 ms time resolution Individual counter for each received and transmitted command; size 128 Interface USB; type B; 115 Kbps; local front access RS 232 local/remote; rear Ethernet; RJ45; 100 Base-T local/remote; front Application PowerSys Operating system Windows XP; Vista; Win7 Network management Interface Ethernet; local; RJ45; 100 Base-T NMS integration SNMPv2/3 Mechanical design Dimensions Height 132 mm/3 U Width 482.6 mm/19 inch Depth 240 mm Weight Approx. 5 kg Color White aluminum; RAL 9006 Maintenance Preventive maintenance not required 482.6 240 84TE = 426.72 465.1 SWT 3000 mechanical design 6

Standards Performance/EMC/Environmental/Safety Performance and testing of teleprotection IEC 60834-1 equipment Electromagnetic compatibility (EMC) directive IEC 61000-6-2; IEC 61000-6-4; IEC 60870-2; 2004/108/EC (EMC directive) Environmental conditions IEC 60721-3; IEC 60870-2 Product safety IEC 60950-1 NMS integration SNMPv2/3 Bursts Surges Damped oscillatory waves Electromagnetic compatibility (EMC) Immunity IEC 61000-6-2, IEC 61000-6-4, IEC 61000-4-2/3/4/5/6/8/12, IEC 60870-2 Electrostatic discharge 8 kv (contact discharge); 15 kv (air discharge) Radiated electromagnetic fields 10 V/m; 80 MHz to 2 GHz Data lines Common mode Differential mode Direct coupling into shield Conducted disturbances Common mode Differential mode Direct coupling into shield 2 kv 2 kv 2 kv (line to ground) 1 kv (line to line) 2 kv (communication cable) 10 V AC, 150 khz to 80 MHz 2.5 kv (line to ground) 2.5 kv (line to line) 2.5 kv (communication cable) Emissions IEC 61000-6-4, CISPR 11/22, IEC 60834-1 RF disturbance emission radiated Limit class A; 20 MHz to 1,000 MHz Conducted emission CISPR; power supply and signal cable Conducted noise IEC 60834-1; 3 mv; 0 Hz to 4 khz Insulation withstand voltage IEC 60950-1 VF input/output 500 V AC Command input/output Alarm outputs G703.1 G703.6 sym. Insulation withstand level 1.2/50 μs IEC 60950-1 VF input/output Digital input/output Command input/output Alarm outputs 500 V AC 500 V AC 1 kv 1 kv 5 kv 5 kv 5 kv Ambient conditions Climatic IEC 60721-3 During operation 5 C to +55 C During storage and transport 40 C to +70 C Relative humidity 5% to 95% Absolute humidity 29 g/m³; no condensation Mechanical IEC 60721-3-3 Degree of protection IP 20 Vibration Stationary use; class 3M3 2 Hz 9 Hz: 1.5 mm amplitude 9 Hz 200 Hz: 0.5 g acceleration Shock Resistance, class 2M1 11 ms pulse duration; 10 g acceleration 7