PTC/PT100 board 2.0 Option

Similar documents
PTC/PT100 board 2.0 Option

PTC/PT100 board 2.0 Option

PTC 2.0 Option board. PTC/RTC Option board. Instruction Manual English. For Emotron VFX/FDU 2.0-IP2Y AC drive. For Emotron FlowDrive-IP2Y

RTC- Real time clock board Option

Technical Catalogue Softstarters

Emotron Safe Stop board Option

Operating instructions. Switching amplifier DN0210 DN / / 2015

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Model 7705 Control Module

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

CPCI-PS24 24V-Power Supply

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours!

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Operating instructions. Speed monitor D / / 2014

MC 11 EB-2 Power supply cabinet with external bus, AC version

Product Data Sheet. Hochiki 8 Way I/O Card. Features

SIMOCODE 3UF Motor Management and Control Devices

Bulletin 817 Thermistor Protection Relay

Resolver to Digital Expansion Board

RTD-W Installation Instructions

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Supplementary operating instructions for your air curtain system Controller TMC 500

TRC-190 User s Manual

SM-I/O Plus. Solutions module for UNIDRIVE SP. User guide. This manual is to be given to the end user. Réf en / a

Chameleon Stand-alone

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

Non-communicating room controllers

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

CUS150M1 Instruction Manual

ASTAT XB/XBm Remote Operator

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

24/48/120 VAC Interface Card Instruction Manual

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC

Product and functional description

Super universal modules

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

TRC-190 User s Manual

Page 2 262/264 LaserMount User s Manual. Table of Contents

Vision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120.

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

SX90 Process Controller

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

IQ21x Series Controllers

F1000 User's Manual. (Version: V1.01)

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

02/11/2015

SMVector Additional I/O Module Installation and Operation Manual

TPE, TPED Series 2000

Expansion Module HZS 541-1S

Emotron AC drive Master-follower functionality

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

Display Panel BAT 100 LSN. en Operation Guide

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

TRIO-DIODE/12-24DC/2X10/1X20

PHOENIX CONTACT Features

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

Operation Manual Series W-500

Switched Mode Power Supply Operating manual PAP800

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Assembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN

See instructions to download and install the latest version of LinkBoxMB and the user's manual at


Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Faults on the system Proximity switch connection technology:

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Operating Instructions

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01

High frequency inverter ACO5000 by ACOMEL USER MANUAL

PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR

ISOMETER isopv with coupling device AGH-PV

ABB Drives. User s Manual Pulse Encoder Interface Module MTAC-01

High Performance Output Filter Instruction Manual

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

Installation Manual. Multi Power Controller MPC-1 multi-line D

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

ACS-30-EU-MONI-RMM2-E

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

InReg Volume flow controller Pa

InCos-P Pressure sensor 20 Pa Pa

Motor Control and Protection Unit M10x AO Module User Guide

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112

TM3TI8T module TM3-8 inputs temperature

USER MANUAL. Longo programmable controller LPC-3.IOR.001 Input Output Relay PLC. Version 2

Transcription:

PTC/PT100 board 2.0 Option Instruction Manual - English

PTC/PT100 board 2.0 Option Instruction Manual - English Document number: 01-3873-01 Edition: r1 Date of release: 2006-10-30 Copyright Emotron AB 2005-2006 Emotron retain the right to change specifications and illustrations in the text, without prior notification. The contents of this document may not be copied without the explicit permission of Emotron AB.

Safety Instruction manual Read this instruction manual first! Since this option is a supplementary part of the variable speed drive, the user must be acquainted with the original instruction manual of the main product. All safety instructions, warnings, etc. as mentioned in this instruction manual are to be known to the user. Safety instructions Read the safety instructions in the instruction manual for the main product. Installation Installation, commissioning, dismounting, making measurements, etc. on the main product may only be carried out by personnel who are technically qualified for the task. Installation must also be carried out in accordance with the local standards. Ensure that all necessary safety measures are taken. WARNING: Take all necessary safety precautions during installation and commissioning to prevent personal injuries, e.g. by an uncontrolled load. Opening the variable speed drive WARNING: Always switch off the mains supply before opening the variable speed drive and wait at least 5 minutes to allow the buffer capacitors to discharge. Always take adequate precautions before opening the variable speed drive, even though the connections for the control signals and jumpers are isolated from the mains voltage. Emotron AB 01-3873-01r1

Emotron AB 01-3873-01r1

Contents 1. Introduction... 3 2. Installation... 5 2.1 Polarisation of flat cables... 5 2.2 Mechanical mounting... 6 2.2.1 Option mounting plate... 6 2.3 Mounting the first option board... 8 2.4 Mounting another option board... 11 3. Connections and functions... 13 3.1 Board layout... 13 3.2 General information... 14 3.2.1 Menus... 14 3.2.2 Status LED... 14 3.2.3 Cable recommendations and shielding... 15 3.2.4 Isolation... 16 3.3 PTC input... 16 3.3.1 Electrical specification... 17 3.3.2 PTC connection example... 18 3.4 PT100 input... 19 3.4.1 Electrical specifications... 20 3.4.2 PT100 connection example... 21 Emotron AB 01-3873-01r1 1

2 Emotron AB 01-3873-01r1

1. Introduction This board is used to connect motor thermistors (PTC) acc. to DIN44081/ 44082 and/or PT100 sensors acc. to IEC 60 751 to the main product. Note that both the PTC and the PT100 sensors needs to be isolated from live voltage, see 3.2.4, page 16 for further details. There are three terminals on the option board, X1 - X3. X1 and X2 for PT100 input and X3 for PTC input. Both PTC and PT100 functions can be used for thermal motor protection. When the monitored temperature e.g. motor temperature becomes too high, the VSD will trip. The PTC and PT100 thermal motor protection function is activated in menu [234]. The PT100 function can also be used as a process temperature feedback to optimise the control. This function can be activated in menu [321]. The PT100 function can also be used for monitoring measured temperatures by the analogue comparators and the programmable levels. This function can be activated in menu [611] or [614]. Emotron AB 01-3873-01r1 Introduction 3

4 Introduction Emotron AB 01-3873-01r1

2. Installation This chapter describes how to mount the option mounting plate and an option board in the main product. Up to three different option boards and one communication board can be mounted. 2.1 Polarisation of flat cables The flat cable is marked with colour on one side and has a tap on the micromatch male contact. This side must be matched to the female micromatch contact on the control board and option board respectively, where a small hole in the board is located. Fig. 1 Polarisation of flat cable! CAUTION: Incorrect connection might cause damage to both the option and to the control board/external equipment. Emotron AB 01-3873-01r1 Installation 5

2.2 Mechanical mounting Make sure that the main product has been switched off for at least five minutes to ensure that the capacitor bank is discharged before continuing with installation! Also make sure that no external equipment connected to the drive s interface is switched on. NOTE: Correct installation is essential for fulfilling the EMC requirements and for proper operation of the module. 2.2.1 Option mounting plate Delivered with the option mounting kit The option mounting plate must be mounted before any option can be installed. The mounting plate may already be installed in the main product. In that case go directly to section 2.3 on page 8 for further mounting instructions. The option mounting kit consists of the following: Colour marked 75 +3-0 Fig. 2 Option mounting kit One mounting plate with the slots marked C, 1, 2 and 3. C = communication option. 2 screws One 16-pole flat cable for connection to the control board when mounting option boards on position 1. 6 Installation Emotron AB 01-3873-01r1

Mounting 1. Make sure that the power supply is switched off for at least 5 minutes before opening the variable speed drive. 2. Open the door to the variable speed drive. 3. Jack the option mounting plate on to the control board mounting plate as shown in Fig. 3. It can only be turned in one direction. 4. Drag the option mounting plate towards the control board until the screw holes match. Keep the side with the screw holes tilted up slightly until the RJ45 contact fits into its hole. NOTE: Be careful not to damage the RJ45 contact (connection for the control panel), see picture below. 5. Secure the plate with the two screws. RJ45 contact Fig. 3 Mounting the option mounting plate on the control board Emotron AB 01-3873-01r1 Installation 7

2.3 Mounting the first option board The first option board is always mounted on the slot marked 1 on the mounting plate. In this example we assume that no other option board is installed. Delivered with the option board kit Option board and four screws. 16-pole flat cable for connection between two option boards. Insulating sheet. Mounting 1. Connect the 16-pole flat cable to the X5 connector on the control board with the cable downwards as in Fig. 4. NOTE: The polarisation of the flat cable, see section 2.1 on page 5. Fig. 4 Flat cable connected to the control board 8 Installation Emotron AB 01-3873-01r1

2. Place the insulating sheet over the short spacers on the slot marked 1 on the mounting plate. Make sure the edge bent upwards is mounted towards the control board interface as in the figure below. Fig. 5 Mounted insulating sheet 3. Connect the other end of the 16-pole flat cable to the X5A connector on the option board. Make sure that the polarisation is correct as in section 2.1 on page 5. NOTE: Connect the micro match male contact to the option in the same manner as on the control board, i.e. the tap on the micro match contact must be fitted into the hole in the PCB. Emotron AB 01-3873-01r1 Installation 9

Fig. 6 Flat cable connected to the option board 4. Put the option board on the spacers. 5. Fasten the board using the four screws. Fig. 7 Mounted option board 10 Installation Emotron AB 01-3873-01r1

2.4 Mounting another option board 1. Place the insulating sheet on the spacers on the option board slot marked 2 or 3. It is necessary to select the slot closest to the already mounted option board. NOTE: Place the insulating sheet with the turned up edge facing the interface of the control board to achieve proper insulation between the option boards. 2. Put the option board on the spacers. 3. Fasten the option board on the spacers using the four screws. 4. Connect the short flat cable between the X5B connector on the first option board and the X5A connector on the option board you have just mounted. Fig. 8 Two option boards mounted on the option mounting plate Emotron AB 01-3873-01r1 Installation 11

12 Installation Emotron AB 01-3873-01r1

3. Connections and functions 3.1 Board layout X5B OUT IN X5A D3 STATUS 21 22 X3 X2 11 12 13 14 1 2 3 4 5 6 7 8 X1 Fig. 9 PTC/PT100 option board layout Emotron AB 01-3873-01r1 Connections and functions 13

3.2 General information 3.2.1 Menus The following menus are available when the PTC/PT100 option board is installed in the main product. All menus are described in the manual for the main product. Table 1 Menus available with the PTC/PT100 option board Menu Function Default Range/Selection 234 Thermal protection Off 235 Motor Class F140 71B PT100 1,2,3 - Off = No thermal protection PTC = PTC protection enabled PT100 = PT100 protection enabled PTC+PT100 = Both protections enabled A 100 C, E 115 C, B 120 C, F 140 C, F Nema 145 C, H 165 C Shows the measured temperature with a resolution of 1 degree, for all PT100 inputs. 3.2.2 Status LED For location of status LED, see Fig. 9. Table 2 Specification of status LED LED Specification D3 Flashing slow (1 Hz) = OK Flashing fast = communication error Off = no power supply 14 Connections and functions Emotron AB 01-3873-01r1

3.2.3 Cable recommendations and shielding Shielded twisted pair cables are recommended. Connect the cable shield firmly (low ohmic connection) to the mounting plate (PE) according to picture below. Mounted option board Shield Signal wires Fig. 10 General shielding The shield must end at the clamp. Only the signal wires should continue to the terminals of the PTC/PT100 option board. In most cases it is recommended that both ends of the shield are connected to PE. This will give a good attenuation of high frequency interference. Shield connection should be made with the largest possible area. Make sure that you select a cable of material appropriate for your environment. Consider ambient temperature, humidity and occurrence of chemical substances such as oil. Standard copper wire with crossing area of approximately 0.14-1.5 mm 2 will be sufficient in most cases. Emotron AB 01-3873-01r1 Connections and functions 15

3.2.4 Isolation The control board in the main product is a Separated Extra Low Voltage (SELV) circuit. This means that this board is safely separated from other circuits that carry higher voltages and is isolated from earth and protective eart conductors of other circuits. The PTC/PT100 circuit on this option board is separated from the control board SELV circuit with separation rated for: 1. Double insulation when used in drives rated up to 480 VAC. 2. Basic insulation when used in drives rated up to 690 VAC. It is recommended that the PTC/PT100 sensors are always separated from live parts with at least basic insulation for the relevant voltage. WARNING: For drives rated higher than 480 VAC it is mandatory to have at least basic insulation from the temperature sensor towards live voltage. 3.3 PTC input This PTC input is for safety reasons isolated from internal supplies and electronics, see 3.2.4, page 16 for detailed information. The PTC sensor should be connected to terminal X3. No polarisation is needed. Up to six PTC may be connected in series according to DIN44081/44082. Table 3 Terminal configuration for PTC connection X3 Name Function 21 T1 PTC input 22 T2 PTC input 16 Connections and functions Emotron AB 01-3873-01r1

3.3.1 Electrical specification R [kω] 100 10 2.825 1.500 1 Trip Reset 0.1-20 Fig. 11 Typical PTC-curve T switch T [ C] The figure above shows a typical PTC-curve. The resistance increases drastically with the temperature after a certain switch temperature, T switch, which is typically 60-120 C (depending on PTC type). Table 4 Electrical specifications for the PTC input Number of PTCs 1 to 6 in series acc. to DIN44081/44082 Trip at 2825 Ω ±10% Reset at 1500 Ω ±10% Measurement voltage U T1-T2 at T switch <1 VDC Emotron AB 01-3873-01r1 Connections and functions 17

3.3.2 PTC connection example 21 22 X3 Fig. 12 Connecting PTC T1 X3:21 L1 L2 L3 M T2 X3:22 3~ Fig. 13 Example of an application with three PTC in series. 18 Connections and functions Emotron AB 01-3873-01r1

3.4 PT100 input The PT100 input is according to EN60751. Connector X1 and X2 on the PTC/PT100 option board have the following terminal configuration: Table 5 Terminal configuration for PT100 input X1 Name Function 1 Feed_1+ Constant current feed channel 1 2 PT100_1+ Positive input for PT100 channel 1 3 PT100_1- Negative input for PT100 channel 1 4 Feed_1- Constant current feed channel 1 5 Feed_2+ Constant current feed channel 2 6 PT100_2+ Positive input for PT100 channel 2 7 PT100_2- Negative input for PT100 channel 2 8 Feed_2- Constant current feed channel 2 X2 Name Function 11 Feed_3+ Constant current feed channel 3 12 PT100_3+ Positive input for PT100 channel 3 13 PT100_3- Negative input for PT100 channel 3 14 Feed_3- Constant current feed channel 3 NOTE: PT100 inputs which are are left unconnected will indicate a temperature of approximately -99 degrees. Emotron AB 01-3873-01r1 Connections and functions 19

3.4.1 Electrical specifications PT100 [Ω] 175.84 138.50 100.00 0 100 200 T [ C] Fig. 14 Sketch of the PT100 resistance/temperature relationship. Table 6 Electrical specifications for PT100 input Standard Temperature range Accuracy EN60751-100 C to +300 C 1% off full scale Menu [71B] in the main product shows the by the PT100 element measured temperature, with a resolution of 1 degree, for all PT100 inputs. 20 Connections and functions Emotron AB 01-3873-01r1

3.4.2 PT100 connection example Three PT100 channels are available for temperature measurement. All three PT 100 channels (X1, pin 1-8 and X2, pin 11-14) can be used as a 4-wire input which can be used for precision measurement to avoid errors due to resistance in connecting wires. 11 12 13 14 X2 PT100 sensor 1 2 3 4 5 6 7 8 X1 PT100 sensor Fig. 15 Connecting PT100 sensors for 4-wire temperature measurement NOTE: To achieve proper 4-wire temperature measurement it is important that Feed_x+ is connected to PT100_x+ and Feed_x- is connected to PT100_x-. Emotron AB 01-3873-01r1 Connections and functions 21

It is also possible to use these 4-wire inputs as a 2-wire input. Then put a jumper between Feed_x+ and PT100_x+ and one between Feed_x- and PT100_x-. See figure below. 1 Feed_1+ PT100_1+ PT100_1- Feed_1- X1 PT100 sensor Fig. 16 Using 4-wire input as 2-wire input. Motor thermal protection When the PT100 function is enabled by selecting function PT100 or PTC+PT100 in menu [234] and the correct motor class is selected in menu [235] this PT100 function will automatically protect the connected motor against overheating. Process value When PT 100 is selected in menu [321], the PT100 element is used for feedback of the actual process temperature to establish an optimised temperature control. Monitoring When PT100_1, PT100_2 or PT100_3 is selected as a Comparator Value in menu [611] or [614] the measured temperature by the concerning PT100 can be used to monitor the temperature level. This analogue comparison can activate a (alarm) signal via Digital Output or Relay. It also can be used to start an action in combination with the comparator and the Virtual Connections. See the main product instruction manual for more information. 22 Connections and functions Emotron AB 01-3873-01r1

Emotron AB, Mörsaregatan 12, SE-250 24 Helsingborg, Sweden Tel: +46 42 16 99 00, Fax: +46 42 16 99 49 E-mail: info@emotron.se Internet: www.emotron.com Emotron AB 01-3873-01r1 2006-10-30