We protect IT DC-MONITORING. When more surveillance leads to added value. Member of the DATA CENTER GROUP

Similar documents
DATA CENTER GROUP WE PROTECT IT. Without compromises. Because it is all about your IT security. We protect IT

DC-ITSafe GUARDIAN OF IT

STULZ Digitronic software Complete control for more reliability and maximum efficiency in data centers

Data Center Infrastructure Management (D.C.I.M.)

VT608 / Switched PDU with 8 outlets

Engineering and Manufacturing Excellence in Data Centre Infrastructure

Self-Contained Equipment Cabinets

SALAMANDER. Automated Infrastructure Management

VT805 / Monitoring system

ROOM GUARD VT335. Environmental Infrastructure monitoring

ROOM GUARD VT335. Environmental Infrastructure monitoring

24/48V Battery Bank Ah High Cycling Long Life

Monitoring system LN-VT325. Environmental Infrastructure monitoring

Next Generation Data Center Facilities Design. Presenter: Ping Lin

VizioGuard Tiny. Datasheet

Monitor ~ Manage ~ Reduce ~ Control

FCU (FREE COOLING UNIT)

RiMatrix S Make easy.

PowerNetGuard INVENTORY MANAGER SOFTWARE HIGHLIGHTS. Features

VT825 / Environmental Monitoring unit. Environmental Infrastructure monitoring

Comprehensive Data Center Energy Management Solutions

APC by Schneider Electric Elite Data Centre Partner

IBM Site Enablement Services

CA ecometer. Overview. Benefits. agility made possible. Improve data center uptime and availability through better energy management

ZLJ\YP[`7YVIL, :[HUKHYK

Innovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s

Product Catalogue 2015 Power Distribution Monitoring & Remote I/O Radio Time Systems Isolators

TEMPERATURE AND ENVIRONMENT MONITORING MONITORE * CONTROL * ALERT * RECORD * ANALYZE

IT infrastructure Next level for data center. Rittal The System Yavor Panayotov Data center Day

How to Increase Data Center Efficiency

GEN II Wireless GSM/GPRS Data Acquisition System

Jack van der Horst, Regional Technology Manager, Asia Pacific. ABB

IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems

COLOCATION 1/4 RACK RACK COLD AISLE CONTAINEMENT PRIVATE CAGE PRIVATE SUITE FLEXIBLE PRICING OPTIONS

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

VMU-C/Y, Em 2 CARLO GAVAZZI. The evolution in Energy Management. Monitoring system for Energy Management. A u t o m a t i o n C o m p o n e n t s

ARCHIMOD HE 240/480 HIGH POWER MODULAR UPS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE

Data Center Infrastructure Management (DCIM) By Jesse Zhuo

Power Monitoring in the Data Centre: Is the Right Time Now? Jacarta Ltd

SERVICE LEVEL AGREEMENT SERVICE LEVEL AGREEMENT ADDENDUM COLOCATION BIT-1 VERSION

Data Center Optimized Controls

Technical System Catalogue CMC III Monitoring System

Run a Smart Workplace Introducing the Digital Building. Digital Building Solutions

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Compatible with all of the AKCP range of Intelligent Sensors it provides a complete environmental, access control and security monitoring solution.

Service Perfect all-round support package for your data centre

Sensor Control... Access Control... securityprobe 5E-X20

Twin Core Data Center Munich

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway

We protect IT. We protect IT

SERVICE DESCRIPTION COLOCATION

securityprobe 5E Standard

The Most Comprehensive DCIM Solution

Technical Overview CM-5 The Compact Climate Monitor Bundle. Get yours direct at:

Control systems. Efficient room control

FRONIUS IG. PV Central Inverter

Temperature Control and Cooling Technology First Choice in Temperature Control

Com X 210, Com X 510 Technical Datasheet

IXcellerate Moscow One Datacentre - Phase 1 & 2 Overview

Command and Control Center

enalyzer enalyzer security

DATACENTER COLOCATION. Flexible, Secure and Connected

Intelligent infrastructure monitoring for software-defined data centers. Intelligent Power Manager Infrastructure Simplified IT-centric monitoring

DATACENTER CAMPUS FRANKFURT. Plan for Every Second

ICT Infrastructure Solutions. Real power for virtualisation

Data Centre. Design and Build. Everything you need to know about designing, installing and maintaining a. Data Centre

Environmental Monitor (RSMICRO)

Delivered the Way Yo u Want

Liebert. DCL up to 35 kw. Modular Rack Cooling

Repeatable IT Hub Rooms

White paper adaptive IT infrastructures

Liebert. DCL up to 35 kw. Modular Rack Cooling

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

Software and accessories

SERVICE DESCRIPTION MANAGED BACKUP & RECOVERY

FRONIUS IG. PV Central Inverter

IBM 42U and 47U 1200mm Deep Static and 42U 1200mm Deep Dynamic Racks for System x

EnergyLok Environmental Monitoring System 300 Product Training. Stephanie Christensen National Account Manager 03/24/16

A modular solution for mobile data storage

FOUR FUNCTIONS ONE SOLUTION

DATACENTER BERLIN Definitely a Good Perspective

StruxureWare TM. Data Center Expert. Data Center Infrastructure Management (DCIM) Software

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

Out of Band Networking Device, Infrastructure, and Environmental Management for Communications Networks

ARTO LIND ABB Ability Datacenter Automation. The way to monitor & control your DC infrastructure (DCIM) Datacenter Infrastructure Management

BUILDING AUTOMATION OF THE FUTURE

Perfect Cooling. A perfect climate for high performance servers

6-Channel power analyser UMG 96RM-E. Operating current and RCM fault current monitoring. Smart Energy & Power Quality Solutions RCM.

POWER SUBSTATIONS. High available switches for power substations

1.0 Executive Summary. 2.0 Available Features & Benefits

84 kw, Tier 3, Direct Expansion, 937 ft 2

INFO GMM EC. Advanced controls system for ECOSS. The New Choice In Evaporative Cooling

Factsheet. Power Generation Service Energy efficiency in power generation and water

Rack Colocation Hosting. Data Centre Solutions Expertly Engineered

Technical Manual Nova: Cabinet Security Management System (CSMS)

ELECTRIC ACTUATORS with PROFINET interface

proudly presents HW group Environment Monitoring Systems

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

IMServ. The power behind energy efficiency. Comprehensive energy and carbon management solutions for your organisation

Data Centre Solutions Expertly Engineered APC Management Software

Transcription:

We protect IT DC-MONITORING When more surveillance leads to added value Member of the DATA CENTER GROUP

DC-MonIToring How more surveillance leads to added value What is your data center doing right now? No alarm does not necessarily mean optimal operation. Because alongside security and availability, efficiency is one of the core challenges of a data center. In order to operate a data center effectively and strategically, there is a basic prerequisite: comprehensive monitoring. Constant monitoring of the data center does not just show its operating status. It makes it easier for managers from IT, facility and finances to avoid foreseeable interferences, increased energy consumption and unnecessary costs in equal measure. We fulfil all these requirements for our customers. In DC-MonIToring, our many years of experience and market knowledge are combined into a complementary solution. They monitor the data center with all its equipment, analyse and above all visualise the data amounts and raise the alarm for the relevant employees where needed. This interplay makes it possible for IT managers and facility managers to immediately identify defective equipment and rectify any damage. Secondly, processes can be adapted and improved at a glance. Last but not least, the management benefits due to the short amortisation periods in terms of the cost-effectiveness of the data center (rapid return on investment). MANAGEMENT Analysis Optimisation Controlling Service SOFTWARE Browser-based portal Recording Visualisation Evaluation HARDWARE Data logger Measuring devices Interfaces Transfer

Monitor größer 3

How DC-MonIToring works Alarm and energy management for your data center The analysis, monitoring and evaluation of alarm and energy data increase the availability and efficiency of your IT infrastructure! The DC-MonIToring products have been developed from the knowledge of the life cycle and functional principle of data centers and offer demand-based tools for the individual phases of the alarm and energy management. For this reason, they not only selectively evaluate various systems. They also provide a comprehensive and long-term analysis of infrastructure, such as air-conditioning systems, UPS, PDUs and much more. In this way, the data center operator quickly becomes aware of where and what potential is in their own resources and how they can operate their data center more securely and economically. Physical Security Notification Management (PSNM) Our Physical Security Notification Management does just that: It shows a wide variety of physical components of the data center network and evaluates them. As a result, both the data center s security and its efficiency can be managed. 7 6 4 3 1 5 1 Energy meter Air conditioning systems 3 UPS 4 Temperature sensor / humidity sensor 5 PDU 6 DCM Agent 7 DCM Delivery 4

Can more secure and efficient operation of the data center be guaranteed? Yes, if the monitoring architecture is adapted to that of the data center. ed. The data can be graphically and chronologically prepared here. In case of failure, the DCM Agent can also raise the alarm with the customer or the Network Operation Center (NOC). IT infrastructure Energy meter 1 Air conditioning systems UPS For this reason, the DCM Agent communicates via measuring stations with all sectors and components of the IT infrastructure. It collects energy-specific key data, which it continually delivers, and transfer this to the DCM Delivery when request- Temperature sensor PDU 3 4 5 Error message 6 7 Hardware DCM Agent records all information / data through defined interfaces + Software DCM Delivery visualises the identified key data graphically and in a chronological sequence. Locationindependent online access Alarm management Customer or Network Operation Center* receives an error message by SMS or email Physical Security Notification Management (PSNM) Customer or Network Operation Center* can access the visualised key data online. *Information about the Network Operation Center can be found on Page 10/11 5

DCM Agent The Collector What is the basis of trade? Information. Ultimately, information leads to knowledge in action. This also applies to data centers. However, two aspects are particularly important for procuring information. Firstly, the maximum degree of security. Secondly, flexibility, interface communication and the option to integrate with existing system and measuring technology. For this reason, the initial basic component and central solution of DC-MonIToring is the DCM Agent. It offers countless options in the smallest space. At each of the measuring stations, it reads and collects the functional and operational information of the entire IT infrastructure that is installed in the data center. Through predefined properties, it compares and evaluates the actual and target values. If any anomalies in the temperature, relative air humidity, water penetration, fire, smoke or motion detection were to occur in the access control or current monitor, the DCM Agent sends an error message via email or SMS to the customer or the Network Operation Center (NOC). Technical details of the DCM Agent 16 digital inlets 1 power supplies (4 VDC for sensors) 4 analogue inlets (0 to 0 ma) digital outlets 1 RS485 interface for expansion (DCM Extension) 1 RS485 interface for expansion (measuring devices) mains adapter (64 W redundant supply) Network connection (RJ45 10/100 Mbit/s) Configuration via the browser SNMP Email, SMS GPRS modem (redundant communication) Dimensions: 44.45 (1HE) x 48.6 mm (19 ) x 300 mm Working temperature: 0 to 50 C (non-condensing) Additional options DCM Extension Hybrid sensor 0 to +50 C / 0 to 100 % air humidity Smoke alarm Water sensor Door contact switch Antenna extension (10 m) External antenna (5 m / -40 to +80 C) 6

DCM Delivery The Compiler But what happens with the information if no faults are reported? Benefits! The performance data can be analysed and visualised. In other words: compiled. Using software, the visible, energy-related key figures can improve the operational procedures in the data center. For this reason, the second basic component and central solution of DC-MonIToring is the DCM Delivery. The software makes the operational and system data transparent on a standard browser, allowing it to be compared and interpreted. As a result, the monitoring of the data center and its IT components can be used directly to continually improve the IT infrastructure in line with requirements. As DCM Delivery is a browser-based software solution, data center operators can access the system at any time using a secure internet connection. Visualisation of the key figures Structuring of the measuring stations and sites Visualisation of the performance data Comparison chart of several IT components Range of services User access through a standard browser (https) Multi-client capable SaaS (Software as a Service) Connection via DCM Agent Recording of equipment, such as USV, air conditioning, PDUs, energy meters via ModbusTCP and SNMP Real and virtual data points Individual structure of data points Consistent saving of data Visualisation of trends in a diagram Historic display of notifications Notifications if the target is deviated from via email or SMS Acknowledgement of alarms Reproduction of escalation processes User-specific dashboard for rapid overview Multilingual 7

DCM Extension The Multi-Collector DCM Extension is then used if more inlets are needed for measuring stations than the DCM Agent already provides. Designed as a slave unit, the DCM Extension connects with the DCM Agent and can collect and transmit further information or data in this way. Technical details 16 digital inlets 1 power supplies (4 VDC for sensors) 4 analogue outlets (0 to 0 ma) digital outlets 1 RS485 interface for connection to the DCM Agent mains adapter (64 W redundant supply) Configuration via the browser of the DCM Agent Dimensions: 44.45 (1HE) x 48.6 mm (19 ) x 300 mm Working temperature: 0 to 50 C (non-condensing) Additional options Hybrid sensor 0 to +50 C / 0 to 100 % air humidity Smoke alarm Water sensor Door contact switch DCM Detection The Detector DCM Detection offers basic monitoring of the most important equipment in the smallest space. The notifications are defined on the web interface of DCM Detection and can be forwarded via the relevant interfaces. As DCM Detection is smaller than the DCM Agent, it is suitable for use in the DC-ITSafe or in peripheral network cabinets. Technical details 4 digital inlets 4 digital outlets sensor connections (RJ45) Wall power supply Network connection (RJ45 10/100 Mbit/s) Configuration via the browser SNMP Email, SMS Dimensions: 104 x 104 x 8 mm Working temperature: 0 to 50 C (non-condensing) Additional options GSM modem Smoke alarm Water sensor Door contact switch Antenna extension (10m) External antenna (5 m / -40 to +80 C) 8

DC-MonIToring in practice Analysis, optimisation and controlling these are the three important points to guarantee a significant increase in the security and profitability of a data center. The PDCA cycle (Plan-Do-Check-Act): analysis (plan), optimisation (do) and controlling (check) are subject to a continual improvement process and integrate the energy management into the day-to-day business of the data center operator. CHECK ACT DO PLAN The use of DC-MonIToring creates added value Example of a customer from the public services sector Starting situation: Upon the initial analysis with DC-MonIToring, it is clear to see that the performance of the cooling plant is extremely high despite the low external air temperature. The refrigeration should work in an operating state of indirect free cooling with the existing external air temperatures. The plant operation mode found here is very inefficient, but remains unnoticed as there are no measurements or visualisation. Optimisation of the operation of a cooling plant Starting situation Result: from here, optimised operation dependant on the external air temperature 5000 4000 3000 000 1000 Watt 5. Feb. 6. Feb. 7. Feb. 8. Feb. 11 10 9 8 7 6 5 4 3 1 0 C Blue = External air temperature Red = Power consumption of water cooler Result: By integrating DC-MonIToring, the customer is able to make the operation and interrelationship of his data center components considerably more effective and efficient in terms of the operating and life cycle costs, with very few resources. After the optimisation is before the optimisation With the support of the RZservices specialists, the customer can continue to optimise and control his IT infrastructure using the PDCA cycle, so continually saving energy and maintenance costs. 9

A professional system must be used professionally By making the decision to integrate DC-MonIToring, an important step towards transparent and effective data center operation is taken. It makes no difference whether this is integrated into an existing IT environment or into one that is currently in planning. RZservices (a sister company of RZproducts) offers professional services for individual data center operational management systems. These mainly consist of special maintenance strategies and operational services that are tailored to the requirements. DC-MonIToring creates the compulsory transparency and supplies reliable data for secure and efficient data center operation. 1 Security technology Air conditioning systems 3 Emergency standby systems 4 Patch / cable management 5 Electrical engineering 6 Cleaning 7 Relocations 1 1 5 6 6 4 4 1 3 7 Service hotline Available 4 hours a day Troubleshooting 4 hours 7 days a week 365 days a year Cost transparency through defined services and prices 10

DC-MonIToring is as individual as every data center. Information management Delivery and assembly of DCM components Connection of the signal contacts Set-up of the customer s internal alarm process System introduction Information management PLUS Delivery and assembly of DCM components Connection of the signal contacts Definition of the SLAs (Service Level Agreements) Set-up of the alarm process to the NOC (Network Operation Center) System introduction Physical Security Notification Management Delivery and assembly of DCM Agent and/or DCM Extension Connection of the signal contacts, energy meters and operating data Use of DCM Delivery with location-independent online access Set-up of the customer s internal alarm process System introduction Physical Security Notification Management PLUS Delivery and assembly of DCM Agent and/or DCM Extension Connection of the signal contacts, energy meters and operating data Use of DCM Delivery with location-independent online access Definition of the SLAs (Service Level Agreements) Set-up of the alarm process to the NOC (Network Operation Center) System introduction The Network Operation Center (NOC) of RZservices is available 4 hours a day, 365 days a year. The team of specialists continually monitor and manage alarm and procedural messages. This occurs on the basis of the agreed Service Level Agreements and the defined processes. In addition to the PSNM modules, RZservices offers services to evaluate and analyse the collected operating data. This includes the analysis of energy supply, key energy figures and the mode of operation of infrastructure components such as refrigeration and cooling distribution, etc. Regular energy efficiency reports, training and workshops to maintain and increase operational quality are also part of the service. Ask for a tailored tender and create the basis for a professional data center operational management system. 11

Premium protection for your IT DC-ITRoom: Customised protection for your IT! Resistance against external influences and risks is one of the decisive factors for IT security rooms. The DC-ITRoom solutions depending on the design and requirement are available in different protective categories and can be adapted individually to the specific practical requirements. DC-ITSafe: for the security of your IT infrastructure DC-ITSafe is a mini data center, which offers individual racks a high level of security and can be expanded at any time. It withstands all fundamental physical risks, is quick and easy to disassemble and reassemble due to its size and can also be used in any location. Its space-saving properties make it possible to use it in very small IT locations. RZingcon Consulting, Strategieentwick- DC-Datacenter-Group GmbH In der Aue 57584 Wallmenroth Germany Phone +49 741 931-0 Fax +49 741 931-111 info@datacenter-group.com datacenter-group.com rz-products.com -1086 0.5 03/016