Operating Instructions

Similar documents
Micro-Ohmmeter Model 6292

TC100 Precision Thermocouple Calibrator

TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE...

Installation and Operation Back-UPS Pro 900

353 PRECISION ALTIMETER TESTER OPERATING INSTRUCTIONS

SERVICE MESSAGES FRONIUS GALVO SERIES 1 ST OF SEPTEMBER 2013

Automated Tuner System Power Distribution Hub

Maintenance station. For DePuy Synthes Power Tools Electric Pen Drive and Air Pen Drive Systems. instructions for use

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

DDE-B Robot station Ref. DDRE-B

Installation and Operation Back-UPS Pro 900

Operating Manual. Micro-Ohmmeter VG - CS200 VG - CS300 VG - CS400 VG - CS600

NETRONICS HS3500 CONTROLLER

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

CS Series. Digital Counting Scale. Operation Manual

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

Designed to make your job easier MSA 2.0 and MSA 2.1 Electrofusion Units

VIBRATION MONITOR CX-RLY

REGARD mA output module. Installation, operation and maintenance

dedicated KVM switch and rackmount screen technology User Manual CV-801 PS/2 DB-15 KVM Designed and manufactured by Austin Hughes

TC-9102 Series Surface Mount Temperature Controllers

LVS 7510 Integrated System Installation and Quick Start Guide for Zebra Printers

MAINS DISTRIBUTION UNIT MDU14-CO

Anatomage, Inc. 111 N. Market St. Suite 500 San Jose, CA USA Page 1 of 16 - TS001 Rev A. 9. Apr.

Zonit μats TM Users Guide μats1-lv Version 1.2

LVS 7510 Integrated System Installation and Quick Start Guide for Zebra Printers

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

TETRIS 2500 High Impedance Active Probe. Instruction Manual

User Manual - KVM Rear Kit Version

E-ACLM-V E-ACLM-P12/8/18 AC LINE MONITORS Installation and Operation Manual

Operation Manual Series W-500

Installation Job Aid for VSP 4850GTS

Getting Started Guide

Operating Instructions STX Series Digital Strap Tension Meter

CMSA-100 Manual. Cinema Media Server Automation

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

GOLDENI. Owners Manual & Safety Instructions. English. model# GOLDi600. Copyright 2017 Smart Grow Technologies, INC All Rights Reserved

MINI-PS AC/10-15DC/8

Operating Manual. Micro-Ohmmeter VG-CS200 VG-CS300 VG-CS400 VG-CS600

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Neutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A

Calder Centaur Workshop Manual

Installation, Operation and Maintenance Instructions

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

INSTRUCTION MANUAL C WA2 WELD ANALYZER

Operating Instructions. LSP-KONSTANTER Series 32K Laboratory Power Supply 8/10.13

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Portable Appliance Tester KT75 OPERATORS MANUAL

PanelView Plus/VersaView CE Terminals and Display Modules

Toll Free: Tel: Fax:

4170 POS System Installation Guide

99 Washington Street Melrose, MA Phone Toll Free Visit us at

OX 5022-CK OX 5042-CK

STEP-PS/1AC/24DC/1.75

Operating instructions. Standstill monitor A / / 2011

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

RT4F-120V/20A-WAC RECTIFIER

EPS Power Supply

Instruction Manual Standard Multi-Position Stirrers Advanced Multi-Position Stirrers

RT4F-110V/25A RECTIFIER

SSW06. Soft Starters.

RT4B-110V/12A RECTIFIER

Installation Job Aid for VSP 4450GTX-HT- PWR+

Technical Specification & Warranty mypos Europe Ltd. mypos Mini EN

Interactive WhiteBoard [ Conducting presentations become easier than ever ]

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

1 Tool Control Unit Ref. DI-D

CL-200A Manual, Rev Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

LCI User Manual mantracourt.com

STYLITIS-POWER OPERATOR S GUIDE

RT4F-48V/50A-WAC RECTIFIER

Back-UPS RS 550 Installation & Operation

B2800 FLOW MONITOR. - For Liquid Meters - PROGRAMMING & INSTALLATION MANUAL Simplified Version

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

BIPOLAR OPERATIONAL POWER SUPPLY

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

Phase comparator. User manual Document version: 02i00 Update:

E-Series Troubleshooting Guide

Getting Started. HP Business PCs

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

OV1000 Part No OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE

DOT MATRIX PRINTER SP6000 SERIES

±15 V Current-Limited Power Supply

WA4204-G2/G3 and WA4304-G2/G3

Quick Start Guide and Health and Safety Information

dedicated KVM switch and rackmount screen technology User Manual CV-1201D DVI-D KVM Designed and manufactured by Austin Hughes

Installation Job Aid for Ethernet Routing Switch 3600 Series

Valid for item nos.: (1-zone) (2-zone) (4-zone) (6-zone) HPS-C-Slot Hotrunner controllers Operating manual

TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE...

LF1-400 Frequency Converter, Operation and Maintenance

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY I INTRODUCTION

Operating Instructions

Quick installation guide

MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter

Transcription:

CHEMICAL DRAINAGE SYSTEMS Fusion Lock Welding Unit Operating Instructions

Table of Contents Specifications...................................................... 4 Important!......................................................... 5 Calibration and Warranty............................................. 5 Certificate of Conformity.............................................. 5 Instructions For Use................................................. 6 General Operation................................................... 6 Data Log Memory................................................... 6 Welding.......................................................... 7 Multiple Connections................................................ 8 Downloading the Weld Memory........................................ 9 Options.......................................................... 9 Passwords........................................................ 10 Error Codes.................................................... 11-13 Repair Information.................................................. 14 Contact Details.................................................... 14 Visit www.zurn.com for further information. 3

Specifications Operating Mode: Zurn Fusion Lock Operating Language: English (others on request) Operating Temperature: -4 to +104 Fahrenheit Data Entry System: Integrated Alpha-Numeric Keypad Data Log Memory: 2,000 Welds (minimum) Data Memory Download: USB Flash Memory Drive Input Voltage: 120 VAC +/- 20%; 96 V to 144 V Input Current: 1 A to 10 A Input Frequency: 50 Hz (40 to 70 Hz) Input Power [Peak]*: 1200 [3960] W Output Current: 15.5 A ac true rms Output Stability: +/- 1.5 % Output Voltage (fitting dependent): 4 V to 52 V Output Power: 62 W to 806 W Power Factor:.09.96 Welding Time: Automatic: Temperature Compensated Weight (with leads): 22 Lbs. Size: 18" x 14" x 8" Environmental Protection: IP65 Input Lead Length: 15 Feet Output Lead Length: 15 Feet *For this equipment to operate correctly, it must be used with a minimum 4 kw power source. Zurn has a policy of continuously improving product design, and as such reserves the right to change specifications of its products without prior notice and with impunity. 4

Important! RISK OF EXPLOSION! This unit must not be used in a gaseous atmosphere. RISK OF ELECTRIC SHOCK! Do not open. No user serviceable parts inside. To avoid damaging the welding unit, do not interrupt the supply voltage or disconnect the output lead while the unit is welding a fitting. This welding unit is Class 1 and must be used with an earthed supply (grounded). This welding unit has been designed for use with electrofusion fittings from the Zurn Fusion Lock System. Calibration and Warranty This welding unit has been manufactured, inspected, and tested in accordance with the quality control systems in place at Zurn. This welding unit has been calibrated using equipment that is traceable to national and international standards through a National Accreditation of Measurement and Sampling (NAMAS) accredited laboratory. NAMAS is a service of United Kingdom Accreditation Service (UKAS). This welding unit has a twelve month calibration and warranty period, active from the first use of the unit by the end user customer. (This date is logged by the welding unit and can be seen by entering the password SFWD in the More Options screen.) Zurn cannot be held responsible for any issues, including problems with installation or leaks, that may arise due to poor quality power supplied at the job site. Zurn specifi cally disclaims responsibility for poor power conditions related to low quality generators or temporary power sources that are feeding multiple devises. A circuit should be used that is able to supply the required power as specifically outlined in the welder manual provided with the product. Fluctuations in voltage, amperage, or frequency may cause inadequate welder performance. Certificate of Conformity This welding unit has been designed to comply with the harmonized standards under the New Approach directives and has been CE marked accordingly. The applicable standards are: 89/336/EEC Electromagnetic compatibility 73/23/EEC Low voltage equipment 98/37/EC Machinery safety 5

Instructions For Use Connect the welding unit to the correct supply voltage and switch it on. The screen will show a welcome message along with the software version and date. The owner information is now shown on the display. (For information on how to program this into the unit, see the Calibration Manual.) The main menu is now shown. During operation, except when welding, pressing the (star) key will jump back to this menu. Note: The operation of the unit can be customized by turning features on and off, such as data logging. This manual details all available modes and features. For infor - mation on how to customize the welding unit, see the Passwords section later on in this manual. General Operation The welding unit is fitted with an alphanumeric keypad which is used by the operator to input data. There are four Quick-Keys: A, B, C, D. These act as quick shortcut keys; their function being prompted on the screen. When entering data, letters and numbers can be selected by repeatedly pressing the same key, e.g. A B C 2 A B C 2. After a short pause the cursor will move to the next position. Special characters and spaces can be selected by pressing the 1 or 0 keys. (This is the same method used for text with mobile phones.) Pressing the A key will Accept the data entry. Pressing the B key will step Back one position. Pressing the C key will Clear the input field. Data Log Memory The unit can record information about the weld, along with the date and time, and additional operator-entered information. It is possible to enter three pieces of information to identify the weld. The first is the Operator s Name, the second is the Location where the weld is being done, and the third is an Information field for more details. The display will show all three pieces of information in turn: Enter the required information and press the A key to accept it. Note: This information will be saved when the weld has been completed and will be prompted the next time the unit is powered on. 6

Welding This mode of operation is designed to weld all fittings. From the main menu: Press the A Quick-Key to select welding, then: On Initial Power Up: The display will ask for first, the Operator s Name; second, the Location where the weld is being done; and third, any Information for more detail. Enter the information as required and press the A key to accept it. After Initial Power Up: The display will ask for the output leads to be connected to the fitting. The display will now ask what size group of fittings are being welded. 1-1/2"-4" can be welded at the same time or 6" can be welded. The display will now ask for the START button to be pressed. Press Start to begin welding. During the weld, the display will show the set welding time and the remaining welding time. This time will be temperature compensated according to the ambient air temper - ature. The unit will monitor the welding to make sure it does not go out of limits. Any faults that are detected will terminate the welding and cause an error message to be displayed. These are listed later on in this manual. The display will ask for the output lead to be disconnected from the fitting. Doing this will reset the unit back to the welding menu. 7

Multiple Connections The unit can weld multiple joints in series. These must be within the same size range (1-1/2"-4" or 6"), and not exceeding the numbers shown in the table below. Joints are connected in series using the link cables provided. Multiple Connection Guide Size - Inches 1-1/2 2 3 4 6 Joints 10 8 4 3 2 8

Downloading the Weld Memory The data log memory is downloaded by using an industry standard USB flash memory device. The data can be encrypted for protection to stop unauthorized alteration of the information. A download program is supplied that unencrypts the data and allows it to be viewed, filtered, graphed, and printed. This software is supplied on the USB memory pen. Run the Install file and follow the instructions. Plug the USB flash memory drive into the USB connector on the side of the welding unit. From the main menu: Press the D Quick-Key to select options. Press the A Quick-Key to select download data. Confirm that you want to download the data. The display will show that it is enumerating the device. While this is showing, the unit is initializing the memory drive. The data will now be downloaded. The display will ask if you want to reset the data log memory. Select Yes or No then disconnect the memory drive when prompted to do so. Options From the main menu: Press the D Quick-Key to select options. Press the B Quick-Key to select other options. From here the time and date can be set, along with supervisor and calibration options. These are password protected. 9

Passwords The following passwords are available: JFMA Set the date. The data can be set in the format dd/mm/yyyy. ATOZ AINF Set the operating language. The available languages are displayed. Press the letter shown to select the language. Show unit information. The serial number, part number, calibration date, and calibration period are shown. Press any key and the weld counters are shown. SFWD Show date of first weld. The date that the first weld was carried out is shown. This is used to set the start of the warranty period. AWKL Clear data log memory. The data log memory is erased. SWUD Update the software. The internal software can be upgraded. Copy the new software onto a USB memory pen and plug it into the USB connector on the side of the box. Enter the password. When prompted, press the A key to accept. The software will now be updated. When completed the screen will show Success!. Unplug the welding unit from the power supply to complete the process. DLEN Set download to plain text. The data download will be a Common Separated Variable (csv) file, with an.xls extension. AWHD Download all welds, including non-logged. This password will download all welds, including those done when the unit was not set to data logging mode. All visible and hidden welds are downloaded. The hidden, non-logged welds will show blank in the operator input fields. Other passwords are available for authorized repair centers. These include calibration, changing owner details, and setting/showing the distributor selling date. 10

Error Codes START-UP FAULTS Code Description Cause Remedy 1 Stuck button on startup Start, Stop, or Keypad is stuck. Free the stuck button. 2 Output fault on startup Welding voltage on output The unit must be returned lead at startup. to a repair agent. 4 No calibration The unit requires calibration. The unit must be returned to a repair agent. 5 Case temperature Case temperature thermal The unit must be returned sensor fault switch is faulty. to a repair agent. 6 Case temperature Case temperature thermal The unit is too hot. Allow it to out of limits switch has tripped. cool down and try again. PRE-WELD FAULTS Code Description Cause Remedy 10 Low supply frequency The supply frequency is Correct the generator speed <40 Hz lower than 40 Hz. or try a different generator. 11 High supply frequency The supply frequency is Correct the generator speed >70 Hz higher than 70 Hz. or try a different generator. 12 High supply voltage The supply voltage is Correct the generator voltage >140V higher than 140 volts. or try a different generator. 13 Low supply voltage The supply voltage is Correct the generator voltage <95V lower than 95 volts. or try a different generator. This can be caused by long extension leads and big fittings. Try removing extension leads. 14 Relay failed to latch on The power relays did not The unit must be returned to a weld start operate correctly when repair agent. weld started. 11

Error Codes, continued WELDING FAULTS Code Description Cause Remedy 0 No fault: Weld completed okay 20 Welding current excessive The welding current is excessively There is a short circuit inside the (>150%) high for more than 0.3 seconds. unit. It must be returned to a repair agent. 21 Welding current high The welding current is more than There is a short circuit inside the (>125%) 25% high for more than 1 second. unit. It must be returned to a repair agent. 22 Welding current high The welding current is more than This could be caused by a poor (>112.5%) 12.5% high for more than 1.5 quality generator with fluctuating seconds. voltage. Try a different generator. If the fault continues, return the unit to a repair agent. 23 Welding current high The welding current is more than This could be caused by a poor (>106.25%) 6.25% high for more than 2 quality generator with fluctuating seconds. voltage. Try a different generator. 24 Welding current high The welding current is more than This could be caused by a poor (>101.5%) 1.5% high for more than 3 quality generator with fluctuating seconds. voltage. Try a different generator. 25 User Stop button pressed The Stop button has been pressed. The operator stopped the weld. 26 Relay unlatched The power relays have Try a different generator. disconnected during welding. 27 Fitting open circuit The output lead has disconnected Reconnect the output lead onto from the fitting during welding. the fitting. Wait for the fitting to become cool to the touch and try again. 28 Welding current low The welding current is more than This could be caused by a (<98.5%) 1.5% low for more than 3 seconds. generator that is too small. Try a bigger generator. It can be caused by long extension leads. Try only using 30-foot extension of the same thickness. 29 Welding current low The welding current is more than This could be caused by a (<50%) 50% low for more than 1 second. generator that is too small. Try a bigger generator. It can be caused by long extension leads. Try only using 30-foot extension of the same thickness. This can be caused by a faulty fitting. Try another fitting. If the fault continues, it must be returned to a repair agent. 12

Error Codes, continued USB MEMORY FAULTS Code Description Cause Remedy 50 USB memory disk full The USB flash memory pen Delete some files from the is full. memory pen or use a different device. 51 USB memory file The USB flash memory pen s Defragment the memory pen. allocation table full file structure has become Follow the instructions in fragmented. Windows. SUPPLY POWER FAULTS Code Description Cause Remedy 126 Cooling time failure The supply power was Allow the cooling time to disconnected during cooling or complete. the cooling time was prematurely ended by the operator. 127 Supply power failure The supply power was Make sure the power does not while welding disconnected during welding. turn off during welding. 13

Repair Information There are no user serviceable parts inside the welding unit. If an internal fault happens with the unit it must be returned to Zurn Industries or one of its authorized service agents for repair. For sales, service and repair: Zurn Industries, LLC Chemical Drainage Systems Operation 1801 Pittsburgh Avenue Erie, Pennsylvania, U.S.A. 16502-1916 Phone: 814/898-1731 Fax: 814/898-2573 www.zurn.com 14

ZURN INDUSTRIES, LLC CHEMICAL DRAINAGE SYSTEMS OPERATION 1801 PITTSBURGH AVENUE ERIE, PA, U.S.A. 16502 PHONE: 814/898-1731 FAX: 814/898-2573 www.zurn.com In Canada: ZURN INDUSTRIES LIMITED 3544 NASHUA DRIVE MISSISSAUGA, ONTARIO L4V 1L2 PHONE: 905/405-8272 FAX: 905/405-1292 Form No. CDS34, 3/08