Sustainable Data Centre

Similar documents
Server Virtualisation Assessment. Service Overview

Technology Lifecycle Management Assessment. Know your network - achieve business agility

Hybrid Wide-Area Network Application-centric, agile and end-to-end

Managed Network Services. Managing your network to enable your digital business

How to measure the real ROI of virtualisation

Software-defined Networking Development Model

Transforming networks and services for communications service providers

addendum Uptime Cisco customer interactive solutions

addendum Uptime Cisco security solutions

Dimension Data s Managed Intrusion Detection and Prevention Service

addendum Uptime Tandberg converged communications solutions

Why Business Model Changes for Higher Education Require New IT Infrastructure Strategies

Consulting services for cybersecurity

Dimension Data Cloud Services

Global entertainment and media outlook Explore the content and tools

Improving digital infrastructure for a better connected Thailand

Access Code and Phone Number

Customers want to transform their datacenter 80% 28% global IT budgets spent on maintenance. time spent on administrative tasks

Digital EAGLEs. Outlook and perspectives

PLEASE NOTE: firms may submit one set of research questionnaires covering both China and Hong Kong or separate sets for each jurisdiction

BSRIA Air Conditioning Worldwide Market Intelligence

Spoka Meet Audio Calls Rates Dial-In UK

Third Annual Green IT & Sustainability Survey: U.S. Results and Services Implications

No Purchase needed

ASSISTING OUR CUSTOMERS IN A WORLD OF CHANGE 2015 AT A GLANCE

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

Allianz SE Reinsurance Branch Asia Pacific Systems Requirements & Developments. Dr. Lutz Füllgraf

EventBuilder.com. International Audio Conferencing Access Guide. This guide contains: :: International Toll-Free Access Dialing Instructions

Insights for Clubs

Purchasing. Operations 3% Marketing 3% HR. Production 1%

Power Analyzer Firmware Update Utility Version Software Release Notes

Application of Green Technology For Data Centre

Benefits of Local Manufacturing

Cisco Aironet In-Building Wireless Solutions International Power Compliance Chart

EE Pay Monthly Add-Ons & Commitment Packs. Version

Collaborative Regulation in the APP Economy

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Excerpt Poland: LTE and Fiber Rollouts to Turn Telecom Market Around, M&A to Continue

MSYS 4480 AC Systems Winter 2015

Turquoise Terminal Returns User Guide for Creating & Uploading a Turquoise Terminal Return

Shell Global Helpline - Telephone Numbers

THE POWER OF A STRONG PARTNERSHIP.

Green Data Centers A Guideline

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

Dashboard. Feb 18, Feb 18, 2008 Comparing to: Site. 13,318 Visits 28,414 Pageviews 2.13 Pages/Visit


Innovative Fastening Technologies

END-OF-SALE AND END-OF-LIFE ANNOUNCEMENT FOR THE CISCO MEDIA CONVERGENCE SERVER 7845H-2400

CISCO IP PHONE 7970G NEW! CISCO IP PHONE 7905G AND 7912G XML

E-Seminar. Voice over IP. Internet Technical Solution Seminar

Cisco AVVID The Architecture for E-Business

Step 1: New Portal User User ID Created Using IdentityIQ (IIQ)

Global Trend and Challenges to Internet Data Centre: High Energy Efficiency Strategies

The Role of SANAS in Support of South African Regulatory Objectives. Mr. Mpho Phaloane South African National Accreditation System

Overcoming the Challenges of Server Virtualisation

Towards the Green Data Centre. Lex Coors Vice President Data Center Technology & Engineering Group

Dataliner Message Displays Using DL50 Slaves with a DL40 Master

EP s approach to Power & Energy efficiency in DCs & paradigms

Alternative phone number: Credit card/debit card number Expiry date: / / DD MM YYYY

INTERNATIONAL INFORMATION SYSTEMS SECURITY CERTIFICATION CONSORTIUM, INC. Annual Meeting Minutes October 15, 2005 Miami, Florida USA

Rockwell Automation ODVA Annual Meeting

Trends and Opportunities in the Global Printing Market. Thayer Long President Association for Print Technologies May 2018

International Business Mail Rate Card

Cisco ONS SDH 12-Port STM-1 Electrical Interface Card

Safety. Introduction

THE CISCO SUCCESS BUILDER PROGRAM THE CISCO SMALL OFFICE COMMUNICATIONS CENTER: AFFORDABLE, PROVEN COMMUNICATIONS SOLUTIONS FOR SMALL ORGANIZATIONS

Introduction to the Export Services Branch Programmes and Services Ministry of International Trade

2014 AT A GLANCE ASSISTING OUR CUSTOMERS IN A WORLD OF CHANGE

Wick Hill Group, River Court, Albert Drive, Woking, Surrey, GU21 5RP

ALL-IN-ONE PRESENTATION SYSTEMS

L-force Controller 3200 C. Control and visualisation compactly combined

MEASURE MONITOR UNDERSTAND

Optimization in Data Centres. Jayantha Siriwardana and Saman K. Halgamuge Department of Mechanical Engineering Melbourne School of Engineering

Digital Opportunity Index. Michael Minges Telecommunications Management Group, Inc.

iclass SE multiclass SE 125kHz, 13.56MHz 125kHz, 13.56MHz

ENHANCED INTERIOR GATEWAY ROUTING PROTOCOL STUB ROUTER FUNCTIONALITY

For: Ministry of Education From Date: 19 November 18-2 December 18 Venue: M1 Shops

Why would you want to use outdoor air for data center cooling?

A 3/25/99 4:23 PM Page 23 APC Global Services 1999 Al Specificat

High-Availability Solutions for SIP Enabled Voice-over-IP Networks

Consumer Insights. Evaluating mobile engagement. February GSMA Intelligence gsmaintelligence.com

Data Centre Energy Efficiency. Duncan Clubb EMEA Data Centre Practice Director CS Technology

Biorisk Management Professional Certification Program. Maureen Ellis Executive Director International Federation of Biosafety Associations

Multi-Site Parallel Testing with the S535 Wafer Acceptance Test System APPLICATION NOTE

Patent Portfolio Overview May The data in this presentation is current as of this date.

18 th National Award for Excellence in Energy Management. July 27, 2017

Griffin Training Manual Address Maintenance

EMC GLOBAL DATA PROTECTION INDEX KEY FINDINGS & RESULTS FOR ITALY

EMC GLOBAL DATA PROTECTION INDEX KEY FINDINGS & RESULTS FOR AUSTRALIA

MORE THAN JUST A PRODUCT, CABLOFIL IS A GLOBAL SOLUTION. Safer, more economic economic and more performant and A SYSTEM AN EXPERTISE A SERVICE

Maximising Energy Efficiency and Validating Decisions with Romonet s Analytics Platform. About Global Switch. Global Switch Sydney East

THE CURRENT STATE OF DATA CENTER ENERGY EFFICIENCY IN EUROPE. White Paper

FORGING A TRUE GLOBAL CONNECTION - BROADBAND PASSES 500 MILLION SUBSCRIBERS

Cisco CallManager 4.0-PBX Interoperability: Lucent/Avaya Definity G3 MV1.3 PBX using 6608-T1 PRI NI2 with MGCP

Cisco Voice Services Provisioning Tool 2.6(1)

Digital Context Pacific Alliance

Overcoming the Compliance Challenges of VAT Remittance. 12 April :55 to 16:30 (CEST)

Traffic Offload. Cisco 7200/Cisco 7500 APPLICATION NOTE

IATF Stakeholder Conference

Strategic IT Plan Improves NYCHA Resident Services While Reducing Costs US$150 Million

Transcription:

white paper Sustainable Data Centre Tackling the Ever-rising Data Centre Energy Costs Why Only Do Half the Job? By Kari Baden Managing Director, Dimension Data Advanced Infrastructure

A whitepaper on tackling the ever-rising data centre energy costs. Abstract Businesses today couldn t operate without IT and to many organisations this means building and running a data centre. This brings with it a whole new set of challenges which have evolved over time and are now focused on raising energy supply costs and energy security. This has come about because of the rapid growth of IT infrastructure and the rapid increases in energy provision. Energy simply didn t register on the data centre radar, but now is a cost line that must be addressed. There are a range of approaches that can be used to tackle the challenges specific to each client. It s important to consider the whole range of options to build your plans to tackle the situation and to get started. Introduction For those with a responsibility for running a data centre, there s most likely already pressure to deliver the availability of applications to internal and external users and to prevent security attacks. On top of these traditional pressures, there s now also the task of managing escalating energy costs. The good news is that there are a range of ways to address the energy question; the challenge is that many organisations are only presented with half the answers by suppliers in the market. The purpose of this whitepaper is to take a holistic view of the solutions available, in order to help those responsible for building, operating and managing data centres determine the options that are best for their organisation. Energy simply didn t register on the data centre radar, but now is a cost line that must be addressed. How did we get here? In the relatively short time span that IT has been deployed in business we have seen massive changes in the role of the data centre and the demands put upon it. In a 40-year period, the environment has changed massively, as figure 1 below highlights. But that s not the end of the story; organisations continue to experience rapid IT growth, while the data centres required to support this growth are aging. In May 2011, data centre research organisation Uptime Institute reported that 36% of the large companies it surveyed expect to exhaust IT capacity within the next 18 months. Aging data centres and infrastructure have considerable energy requirements and unnecessary operational costs, imposing capacity limits that affect uptime and flexibility. Poorly managed real estate and underutilised technology also lead to inefficiencies and high energy costs. Helen Tang Worldwide Lead, Data Centre Transformation Solutions HP Enterprise Business Figure 1: IT Evolution and the data centre Internal users only Non business critical Limited applications Limited storage volumes (data only) Specialist users & operations Limited security threats (maninly physical) Small number of large machines Energy costs not considered Internal & external users / borderless Business critical Multiple applications Explosion of storage volume (data, voice & video) Ubiquitous Many security threats Large number of machines Engergy a major consideration 1970 1980 1990 2000 2010 Next Large Mainframes Microcomputers Client Server Computing Internet Data Centres Dot Com Boom Hosting Energy Efficient Cloud Green Data Centre Private Data Centres 01

Hence, the stage is set for the need to build more data centres to cope with the capacity demand, and/or upgrade and expand existing data centres, and in either case ensure that the current energy inefficiencies are addressed. The facts and figures are: A Stanford University report published in 2011, entitled Growth in Data Center Electricity Use 2005 to 2010, estimated that the amount of electricity consumed by data centres worldwide grew by 56% between 2005 and 2010. Figure 2: Data centre carbon footprint IT energy costs are increasing by 16% every year, according to a report by McKinsey & Company and the Uptime Institute. Electricity used in global data centres in 2010 is likely to have accounted for 1.1 1.5% of total electricity use, respectively. For the US, that number was 1.7 2.2%, according to the Stanford study. Unless addressed, this will also influence carbon emissions to which IT data centres are a major contributor and, where applicable, the ability of a business to meet regulations and commitments. Greehouse gas emissions from data centres have already passed the output of Argentina and are due to pass those of all airlines by 2020 CO2 Souce of map http://mapsof.net/map/argentina-flag-map IT energy costs are increasing by 16% every year, according to a report by McKinsey & Company and the Uptime Institute. Electricity used in global data centres in 2010 is likely to have accounted for 1.1 1.5% of total electricity use, respectively. What can be done? The good news is that there are ways to address this excessive use of energy, but identifying the optimum combination of approaches to address the issue in your organisation is needed. The answers are typically split between technology infrastructure approaches and facilities infrastructure approaches. Technology infrastructure is often offered by manufacturers and resellers; facility infrastructure is generally offered by specialist facility builders and infrastructure equipment vendors, with facility services usually offered by specialist providers. Since suppliers tend to function in one of these two areas, only half of the solutions are presented for consideration. McKinsey created a 10-point list of areas to address in their report entitled 10 Game Changing Improvements to Double Efficiency. Figure 3: 10 Game Changing Improvements to Double Efficiency Facilities infrastructure Create data centre energy dashboard to identify pain points Reduce cooling loss through sealing cable cut-outs, rationalising cable plans, etc. Increase cold aisle temp, eliminate duelling cooling units, increase chilled water temp Implement free cooling where applicable Selectively turn off core components to increase remaining unit efficiency Technology infrastructure Remove dead servers Upgrade older equipment (non-virtualised) Deploy virtualisation for existing and new demand Reduce demand for new servers Introduce greener and more power efficient servers and enable power-saving feature Source: McKinsey and Company 02

For example, an average data centre runs at 18-21 C. However, the majority of hardware can easily run at 30 C. Therefore, as Quocira noted in its report entitled The Future of Green February 2010, running at 26 C will have minimal impact on the equipment s life, but a massive impact on energy used for cooling and raised output heat quality. One key point to emphasise about the hardware infrastructure is the impact of moving from current client server infrastructure to virtualisation, and then to unified infrastructure. The figures below show the significant reduction in server population, bringing with it the economic benefits of lower power, cooling and simpler management. The McKinsey list provides an excellent basis upon which to create additional ways of addressing the situation. Figure 4: Technology infrastructure Impact Client server infrastructure Typically 1 application per server Virtualised infrastructure Typically 2 3 application per server Unified infrastructure Typically 20 application per server Unleashing all the attendant power, cooling footprint benefits in addition to simpler management etc. Figure 5: What can we do? Technology infrastructure Remove dead servers Upgrade older equipment (non-virtualised) Deploy virtualisation for existing and new demand Reduce demand for new servers Introduce greener and more power efficient servers and enable power-saving features Take a green perspective to ILM Facility infrastructure Create data centre energy dashboard to identify pain points Reduce cooling loss through sealing cable cut-outs, rationalising cable plans, etc. Minimise under floor-cabling Increases cold aisle temp, eliminate duelling cooling units, increase chilled water temp Hot aisle / cold aisle layout Distribute power across racks Implement free cooling where applicable Selectively turn off core components to increase remaining unit efficiency Facility services Co-generation Trigeneration Alternative energy Low energy cooling Heat recovery Self-powering systems Energy recover Load shedding & store Investigate liquid cooling Dashboard 03

Below are definitions of the terms used in the Facility services section of Figure 5, as these may be less familiar: Cogeneration Cogeneration also known as combined heat and power (CHP) is the use of a heat engine or a power station to simultaneously generate both electricity and useful heat. Trigeneration Trigeneration also known as combined cooling, heat and power (CCHP) refers to the simultaneous generation of electricity, useful heating and useful cooling from the same original heat source such as fuel or solar energy. Waste heat insufficient in energy to produce electricity through mechanical means, such as through a steam turbine, contains usable energy that s harnessed for thermal regulation purposes as described in cogeneration. Trigeneration differs from cogeneration in that some of the waste heat is used for cooling. Trigeneration systems can attain higher efficiencies per unit fuel than cogeneration or traditional power plants. Alternative energy Alternative energy is an umbrella term that refers to any source of usable energy intended to replace fossil fuel sources and reduce the CO² output of the data centre without the undesired consequences of the replaced fuels. Such sources include air, water, solar, geothermal or a combination of these sources to increase the overall efficiency of the systems. Low energy cooling By using free cooling methods and intelligent building controls, the cooling requirements can be met at lower energy costs to those of a typical existing system. To name a few examples, these could include variable speed drives, low loss cooling towers, and evaporative cooling. Heat recovery In instances where the treated air still has useful energy left within it, this can be recovered or re-used instead of being exhausted. Load Shedding & Store Load shedding is used in times of mains failure where non-essential servers are shut down, which in turn reduces the size of back-up generators and UPS sets. Since any combination of solutions could address your situation, working with an organisation who can take the broader view is imperative. 04

How do we know we are making a difference? To measure progress, meaningful metrics need to be adopted. Lower energy consumption would be a good start, but being more sophisticated is necessary to fully understand the impact. A number of measures have been put forward, which are outlined below, and an additional measure has been added for consideration. Power Usage Effectiveness (PUE) is a metric used to determine the energy efficiency of a data centre and was created by members of the Green Grid, an industry group focused on data centre energy efficiency. PUE is calculated by dividing the amount of power entering a data centre by the power used to run the computer infrastructure. The resulting PUE figure is expressed as a ratio, with overall efficiency improving as the ratio decreases toward 1. PUE = Total Facility Power / IT Equipment Power Data Centre infrastructure Efficiency (DCiE) is the reciprocal of PUE, and is expressed as a percentage that improves as it approaches 100%. Although, the DCiE seems to be the same PUE, it uses the same numbers to express a different result. DCiE = IT equipment power / total facility power An alternative metric, proposed by McKinsey & Company and the Uptime Institute, is called Corporate Average Data Efficiency (CADE) and combines both IT and facilities costs to monitor energy. CADE combines measurements of the energy efficiency and utilisation of IT equipment and facilities into a single percentage. A higher CADE indicates a more energy efficient data centre. Figure 6: PUE and DCiE examples Figure 7: Measuring a sustainable data centre PGE Level of Efficiency 3.0 Very Inefficient 2.5 Inefficient 2.0 Average 1.5 Efficient IT Equipment Power Servers Storage Networking etc PUE Example: Having a facility that uses 1,000 kw of total power of which 800 kw is used to power your IT equipment, would generate a PUE of 1.25. The 1,000 kw of total facility power divided by the 800 kw of IT power. CADE = Facility Efficiency (FE) x Asset Efficiency (AE) Where: Facility Efficiency (FE) is equal to (facility energy efficiency) x (facility utilisation) Asset Efficiency (AE) is equal to (IT energy efficiency) x (IT utilisation) The PUE or DCiE takes into account how efficiently the energy is being used to power IT equipment, but these measurements don t calculate the sustainability of the data centre. Therefore, an additional measure could be defined, Power Generation Efficiency (PGE). 1.2 Very Efficient PUE DCiE Level of Efficiency 3.0 33% Very Inefficient 2.5 40% Inefficient 2.0 50% Average 1.5 67% Efficient 1.2 83% Very Efficient DCiE Example: Having that same facility that uses 1,000 kw of total power of which 800 kw is used to power your IT equipment, would generate a DCiE of.8. The 800 kw of IT power divided by the 1,000 kw of total facility power. PGE = Total facility power / total power from renewable sources As an example, a facility that uses 1,000 kw of total power, of which 800 kw is generated from renewable energy sources, would generate a PGE of 1.25. This number is derived from the 1,000 kw of total facility power divided by the 800 kw of renewable generation. To get an ample metric, a combination of PUE and PGE or CADE and PGE calculations would give a true figure of the overall sustainable credentials of the data centre. PGE 3 2.5 2 1.5 Example: Combining the 2 parameters 1 1 1.5 2 2.5 3 PUE Lower energy consumption would be a good start, but being more sophisticated is necessary to fully understand the impact 05

How do we get started? Improving and measuring the sustainability of your data centre is a large and complex problem and must be tackled both from a business and environmental perspective. Here s a recommended sevenpoint action plan to get started: 1. If you haven t already done so, appoint an individual with the authority, influence, credibility and respect within the organisation to take ownership and leadership of implementing solutions and monitoring your progress. 2. Establish a baseline of where you are today, using the appropriate metrics above, and set a tangible goal to achieve improvements that impact and benefit the business. 3. Set a performance indicator or measurement for the person you have appointed to deliver the improvement. Ensure that this person has the remit to work across functions within the business (e.g. IT development, IT operations, facilities, procurement, etc.). 4. Set up the appropriate governance to review progress and make sure organisational boundaries don t affect this progress. 5. Identify areas for improvement and build a plan with clear milestones looking at the impact and ease of addressing each area of improvement. 6. Implement the plan and work with organisations that share your holistic, cross-functional approach. 7. Monitor and measure the impact on the agreed metrics and reference this against the baseline (step 2) to ensure you are achieving the desired goals. Figure 8: Impact versus Ease analysis Define the parameters that would make up the Impact Vs Ease analysis: Examples Ease Ease of identifying solutions Ease of implementation Ease of integration Ease of on-going support Impact Impact on the metrics Impact on the business Cost Vs return Start by simply rating these H (high), M (medium) & L (low) and weight if required In conclusion Understanding and reducing energy in an organisation s data centre is a very real problem that must be addressed. This will influence the ability of a business to deliver cost-effective IT and meet regulations and commitment targets. It can be addressed by understanding what s available, how to measure the results, and how to progress from there. Figure 9: Call to action To Do... Drive Down IT Costs Drive down energy costs Every server virtualised saves up to 7000kWH of electricity annually Increase Asset Utilisation High Low Impact Improve server utilisation Running fewer, highly utilised servers frees up space and power Low High Ease Understanding and reducing energy in an organisation s data centre is a very real problem that must be addressed. Reduce your number of servers eliminating server sprawl and cutting maintenance costs Reduce Carbon Emissions For every kwh eliminated saves 0.5kg CO 2 CS / DDMS-0832 / 01/12 Copyright Dimension Data 2011 For further information www.dimensiondata.com 06

Middle East & Africa Asia Australia Europe Americas ALGERIA ANGOLA BOTSWANA CONGO BURUNDI DEMOCRATIC REPUBLIC OF THE CONGO GABON GHANA KENYA MALAWI MAURITIUS MOROCCO MOZAMBIQUE NAMIBIA NIGERIA RWANDA SAUDI ARABIA SOUTH AFRICA TANZANIA UGANDA UNITED ARAB EMIRATES ZAMBIA CHINA HONG KONG INDIA INDONESIA JAPAN KOREA MALAYSIA NEW ZEALAND PHILIPPINES SINGAPORE TAIWAN THAILAND VIETNAM AUSTRALIAN CAPITAL TERRITORY NEW SOUTH WALES QUEENSLAND SOUTH AUSTRALIA VICTORIA WESTERN AUSTRALIA BELGIUM CZECH REPUBLIC FRANCE GERMANY ITALY LUXEMBOURG NETHERLANDS SPAIN SWITZERLAND UNITED KINGDOM BRAZIL CANADA CHILE MEXICO UNITED STATES For contact details in your region please visit www.dimensiondata.com/globalpresence