Fieldbus System (Output device for driving port solenoid valves) Compact 8mm (Actual size) Space-saving Installation Daisy-chain wiring communication New IP67 For units with D-sub connector, and when connected to manifolds, it is IP0. Drives up to solenoids RoHS EtherNet/IP added! Applicable Fieldbus protocols New Top ported valve Bottom ported valve Side ported valve Mixed valve sizes manifold 7 mm width valve Series EX60 IP67 IP67 IP67 IP0 CAT.NAS0-B
E Manifold length is shortened by the small fieldbus output module (SI unit). 8. mm 8 mm Wiring and piping from the same direction is possible. (for side ported) Effective for installation in locations where space is limited above the valve. Existing model EX0 External branch connector is not necessary. Daisy-chain wiring is possible. Reduced wiring space EX60 Branch connector Existing model (EX0) External terminating resistor is not necessary. (Only available for PROFIBUS DP, CC-Link communication connectors) Product Specification Variations ON/OFF switching is possible with an internal terminating resistor. External terminating resistor is not necessary. External terminating resistor Number of outputs P Output polarity Internal terminating resistor / B B B B B / E A A A A A Communication connector D-sub Communication connector examples / E B B B B B / E SI unit Features Fieldbus A A A A A communication connector (PROFIBUS DP) D-sub communication connector (PROFIBUS DP)
Series / Pressure switch Valve piping direction variations " Piping is possible from directions. Top ported <Example of Use> Bottom ported Side ported By mounting top ported valves on side ported and bottom ported type manifolds, it is possible to detect the output of the A/B port with a pressure switch. Side ported Mixed mounting of top ported and side ported is possible. Valves can be freely connected up to stations. Mixed valve sizes manifold " It is possible to connect only the number of valves required, from to stations, to suit the application. (Maximum number of solenoids connected: ) Series " Valves of different sizes, and, can be mounted on the same manifold. " It is possible to connect only the number of 7 mm width valves required, from to stations. (Maximum number of solenoids connected: ) 7 mm width valves can be connected.! Applicable Valve Series Flow-rate characteristics (/ /) Maximum number of C [dm/(s bar)] b solenoids Series.6 Power consumption (W) Enclosure 0. (standard) 0. (with powersaving circuit) IP67 page 7 0. IP0 page 8 0.6 IP67 0.9.6 0.7 0.7 0.9 SV000. 0. SV000. 0.8 Standards Page page SV. 0. VQC000.0 0.0 0. (standard) VQC000. 0.0 VQC000 7. 0.8 IP67 page 9.0 (standard) Note) For units with D-sub communication connector, it is IP0. Features
Fieldbus System Variations IP67/6 specification models I/O separated type I/O integrated type Valve outputs only Inputs only Gateway-type valve outputs only inputs only Valve outputs with multiple I/O s Valve outputs with inputs Number of valve outputs EX60 EX6 EX EX00 EX600 EX0 Number of inputs Number of valve outputs Number of inputs SI unit series EX60 None EX6 EX (total 6) (total 6) EX60 EX00 EX600 EX0 PROFINET EtherCAT Open network EtherNet/IP PROFIBUS DP DeviceNet CC-Link AS-Interface CANopen CompoNet (Plug-in connector connecting base) (Stacking base) 0700 Applicable valve series SV VQC VQ 000 000 000 000 000 000 000 000 000 Features
Fieldbus System Variations IP0 specification models I/O separated type I/O integrated type Valve outputs only Inputs only Gateway-type valve outputs only inputs only Valve outputs with multiple I/O s Valve outputs with inputs Number of valve outputs EX0 EX EX EX0 EX80 EX0 Number of inputs Number of valve outputs Number of inputs SI unit series EX0 (total 6) None (total 6) EX EX EX0 EX80 EX0 Applicable valve series Open network PROFINET EtherCAT EtherNet/IP PROFIBUS DP DeviceNet CC-Link AS-Interface CANopen CompoNet (Plug-in connector connecting base) SJ (Plug-in metal base) (Bar stock) (Bar stock) (Stacking base) SV VQ SQ SZ VQZ J 000 0700 7000 7000 000 000 000 000 000 000 000 000 000 000 7000 Features
SI Unit Integrated-type/For Output Series EX60 Note) RoHS Compact design Compact design for space saving Number of outputs Each / digital output type available in the series Output polarity Each negative common () / positive common () type available in the series Enclosure IP67 (For units with D-sub connector, and when connected with manifolds, it is IP0.) Internal terminating resistor ON/OFF switching is possible with an internal terminating resistor for communication. (Only for units compatible with PROFIBUS DP, CC-Link communication connectors) / VQC000/000/000 SV000/000/ D D D D Note) The /, VQC000/000/000, and are not yet UL-compatible. How to Order SI Units EX60 S PR Communication protocol Symbol Protocol DN DN DeviceNet DN DN PR PR PR PR PROFIBUS DP PR PR6 PR7 PR8 MJ MJ CC-Link MJ MJ EC EC EtherCAT EC EC PN PN PROFINET PN PN EN EN EtherNet/IP EN EN Number of outputs SI unit output polarity Note) Enclosure is IP0 when the communication connector is D-sub. Communication connector D-sub Note) Manifold symbol QAN QA QBN QB NAN NA NBN NB NCN NC NDN ND VAN VA VBN VB DAN DA DBN DB FAN FA FBN FB EAN EA EBN EB
Integrated-type/For Output Series EX60 SI Unit Specifications Applicable system I/O occupation area (Inputs/Outputs) Communication speed Power supply Power supply voltage for control Internal current consumption Power supply for output Power supply voltage Power supply for Power supply voltage communication Internal current consumption Communication connector specification Terminating resistor switch Output Environmental resistance Standards Weight Model EX60-SPR/ EX60-SPR/ EX60-SPR/7 EX60-SPR6/8 EX60-SDN/ EX60-SDN/ EX60-SMJ/ EX60-SMJ/ Protocol PROFIBUS DP DeviceNet CC-Link Version Note ) DP-V0 Volume (Edition.) Volume (Edition.) Ver..0 Configuration file Note ) GSD file EDS file SPR: 0/ SPR: 0/ SPR: 0/ SPR6: 0/ SDN: 0/ SDN: 0/ SMJ: / SMJ: / SMJ: / SMJ: / SPR: 0/ SPR: 0/ SPR7: 0/ SPR8: 0/ SDN: 0/ SDN: 0/ ( station, ( station, remote I/O stations) remote I/O stations) k/0 k/00 kbps 6 k/6 k/. M/ M/0 Mbps Output type Number of outputs Load Supplied voltage Supplied current Enclosure Operating temperature range Operating humidity range Withstand voltage Insulation resistance Mounting screw Accessories Seal cap (for connector socket) SPR: points SPR: points SPR: Max..0 A SPR: Max..0 A 9.6 k/9. k/. k/9.7 k/ 87. k/00 k/. M/ M/6 M/ Mbps.6 to 6. VDC 00 ma or less Built-in SPR: points SPR: points.8 to 6. VDC to VDC 00 ma or less D-sub None Built-in SPR: points SPR7: points SPR6: points SPR8: points SDN: points SDN: points Solenoid valve with protective circuit for surge voltage of VDC/. W or less (SMC) VDC SPR: Max..0 A SPR: Max..0 A SPR6: Max..0 A SDN: Max..0 A SDN: Max..0 A SMJ: Max..0 A SPR: Max..0 A SPR7: Max..0 A SPR8: Max..0 A SDN: Max..0 A SDN: Max..0 A SMJ: Max..0 A IP67 IP0 IP67 to F ( 0 to 0 C) to 8%RH (No condensation) 00 VAC for minute between terminals and housing 0 MΩ or more (00 VDC measured via megohmmeter) between terminals and housing CE marking, UL (CSA) compatible 0. lbs (00 g) pcs. SDN: points SDN: points EX9-AWTS ( pc.) EX9-AWTS ( pc.).6 to 6. VDC 00 ma or less SMJ: points SMJ: points SMJ: points SMJ: points SMJ: Max..0 A SMJ: Max..0 A EX60 SV Applicable system I/O occupation area (Inputs/Outputs) Communication speed Power supply Power supply voltage for control Internal current consumption Power supply for output Power supply voltage Power supply for Power supply voltage communication Internal current consumption Communication connector specification Terminating resistor switch Output Model EX60-SEC/ EX60-SEC/ EX60-SPN/ EX60-SPN/ EX60-SEN/ EX60-SEN/ Protocol EtherCAT Note ) PROFINET Note ) EtherNet/IP Note ) Version Note ) Conformance PROFINET Specification Volume (Edition.8) Test Record V.. Version. Volume (Edition.9) Configuration file Note ) XML file GSD file EDS file SEC: 0/ SEC: 0/ SPN: 0/ SPN: 0/ SEN: / SEN: / SEC: 0/ SEC: 0/ SPN: 0/ SPN: 0/ SEN: / SEN: / 00 Mbps Note ) 0 M/00 Mbps Note ).6 to 6. VDC 00 ma or less.8 to 6. VDC None Output type Enclosure Operating temperature range Environmental Operating humidity range resistance Withstand voltage Insulation resistance Standards Weight Mounting screw Accessories Seal cap (for connector socket) Number of outputs SEC: points SEC: points SPN: points SPN: points SEN: points SEN: points SEC: points SEC: points SPN: points SPN: points SEN: points SEN: points Load Solenoid valve with protective circuit for surge Solenoid valve with protective circuit for surge Solenoid valve with protective circuit for surge voltage of VDC/. W or less (SMC) voltage of VDC/.0 W or less (SMC) voltage of VDC/. W or less (SMC) Supplied voltage VDC Supplied voltage SEC: Max..0 A SEC: Max..0 A SEC: Max..0 A SEC: Max..0 A SPN: Max..0 A SPN: Max..0 A SEN: Max..0 A SEN: Max..0 A SEN: Max..0 A SEN: Max..0 A SPN: Max..0 A SPN: Max..0 A IP67 to F ( 0 to 0 C) to 8%RH (No condensation) 00 VAC for minute between terminals and housing 0 MΩ or more (00 VDC measured via megohmmeter) between terminals and housing CE marking, UL (CSA) compatible 0. lbs (00 g) pcs. EX9-AWTS ( pc.) Note ) Please note that the version is subject to change. Note ) Use a CAT or higher transmission cable for EtherCAT, PROFINET, EtherNet/IP. Note ) Each file can be downloaded from the SMC website, http://www.smcworld.com VQC
Series EX60 SI Unit Dimensions (mm) communication connector type D-sub communication connector type 0. 90.9 0. 90.9 8. 0.6. 9 76. 8. 8.7 9. 9 76. Functions of SI Unit Parts <LED indication and setting switch> <Setting switch> Address switch Communication speed switch Terminating resistor switch Others Note) The setting switch varies depending on the model. Refer to the operation manual for details. Please download it via the SMC website, http://www.smcworld.com <LED indication> Communication state Unit power supply state Valve power supply state <Connector> communication connector type Part Communication protocol Communication connector () BUS OUT Communication connector () BUS IN Ground terminal Power connector () D-sub communication connector type Ground terminal Part Communication protocol Communication connector (D-sub) BUS IN/OUT Power connector () EX60-SPR/-SPR -SPR/-SPR PROFIBUS DP pins, socket, B code pins, plug, B code pins, plug, A code EX60-SDN DeviceNet pins, socket, A code pins, plug, A code pins, plug, A code M EX60-SPR/-SPR6/-SPR7/-SPR8 PROFIBUS DP M 9 pins, socket pins, plug, A code EX60-SMJ CC-Link pins, socket, A code pins, plug, A code pins, plug, B code EX60-SEC EX60-SPN EX60-SEN EtherCAT PROFINET EtherNet/IP pins, socket, D code pins, socket, D code pins Note), pins Note), plug, A code Note ) For EtherCAT, PROFINET Note ) For EtherNet/IP
Integrated-type/For Output Series EX60 Accessories q Communication cable with connector For SI units compatible with PROFIBUS DP, DeviceNet, CC-Link For SI units compatible with EtherCAT, PROFINET, EtherNet/IP Refer to the catalog (CAT. NAS00-7) for details. EX9 AC 00 Cable length (L) 00 000 [mm] 00 000 [mm] 00 [mm] 00 [mm] 00 0000 [mm] EN ø6.7 PSRJ Connector specification PSRJ plug (straight) RJ- connector 7. L RJ- EX60 Plug connector D code Shield Connections (Straight cable) Core wire colors White Orange Pair White Pair 6 Green 7 8 6 7 8 Plug connector For SI units compatible with EtherCAT, PROFINET, EtherNet/IP PCA 666 Cable length 666 [mm] SV ø.8 7. 0 Plug connector D code SPEEDCON (ø6.) Wire guide color Yellow: TD+ White: RD+ Orange: TD Blue: RD VQC Connections For SI units compatible with EtherCAT, PROFINET, EtherNet/IP Fieldwireable connector PCA 6 6 ø7. Plug connector D code ø9 Width across flats Width across flats
Series EX60 Accessories w Power cable with connector (for SI units) For SI units compatible with PROFIBUS DP, DeviceNet, EtherCAT, PROFINET, EtherNet/IP EX00 AP 00 Cable length (L) 00 000 [mm] 00 [mm] Straight connector type S Connector specification S Straight A Angle Angle connector type ø.9 ø6 8. ø6 Socket connector A code 8 8 Connections (PROFIBUS DP/EtherCAT) For SI units compatible with CC-Link Straight connector type L 0 A code Core wire colors Brown: VDC +0%/ % (Solenoid valve power supply) White: 0 V (Solenoid valve power supply) Blue: VDC ±0% (Control power supply) Black: 0 V (Control power supply) Gray: Not connected e Seal cap: For connector socket PCA Use this on ports that are not being used for communication connector ( connector socket). Use of this seal cap maintains the integrity of the IP67 enclosure. Note) Tighten the seal cap with the prescribed tightening torque. (For : 0.07 lbf ft (0. N m) EX9 SPEEDCON Cable length (L) 080 00 [mm] 080 [mm] 0806 [mm] EX9 AC 00 Cable length (L) 00 000 [mm] 00 [mm] 00 [mm] PCA 080 SPEEDCON 0807 Cable length (L) 0807 00 [mm] 0808 [mm] 0809 [mm] AW TS Connector type TS For connector socket (0 pcs.) Socket connector Socket connector B code 0 Socket connector B code ø.8 ø.8 Connections Socket connector A code 0.. Core wire colors Connections (DeviceNet, EtherNet/IP ). L 0 SPEEDCON 8.. SPEEDCON ø.0±0. ø.0±0. L Cable core wire colors x For connector socket L L 0 Brown: Not connected Note ), VDC ±0% (Control power supply) Note ) White: VDC +0%/ % (Solenoid valve power supply) Blue: Not connected Note ), 0 V (Control power supply) Note ) Black: 0 V (Solenoid valve power supply) Gray: Not connected Note ) For DeviceNet Note ) For EtherNet/IP ø6. Brown: VDC +0%/ % (Solenoid valve power supply) White: 0 V (Solenoid valve power supply) Blue: VDC ±0% (Control power supply) Black: 0 V (Control power supply) Gray: Not connected 0 0 0 0