How to use a project file with an out of date firmware with actual firmware version

Similar documents



Position Control with SIMATIC S and SINAMICS V90 via IRT PROFINET SINAMICS V90 PROFINET. Application description 03/2016



Firewall Settings for SIMATIC B.Data


Acyclic communication between S and V90PN via PROFINET. Application example 12/




How do you establish MODBUS-RTU communication?


How do you access an SQL database in WinCC Runtime Advanced using a script?





Configuration of an MRP Ring and a Topology with Two Projects


SINAMICS G120/G120D/G120C/G120P/G110M



Communication between HMI and Frequency Converter. Basic Panel, Comfort Panel, Runtime Advanced, SINAMICS G120. Application Example 04/2016

Determination of suitable hardware for the Process Historian 2014 with the PH-HWAdvisor tool

SINAMICS G/S: Integrating Warning and Error Messages into STEP 7 V5.x or WinCC flexible

SINAMICS G/S: Tool for transforming Warning and Error Messages in CSV format


SIMATIC PDM - Central access to MODBUS RTU devices






Encoder Configuration for the Positioning Axis Technology Function

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2.

SIMATIC. Industrial PC Microsoft Windows 7 (USB stick) Safety instructions 1. Initial startup: Commissioning the operating system

Configuration of an MRP ring with SIMOCODE and SIMATIC S SIMOCODE pro V PN, SIMATIC S Siemens Industry Online Support


SIMATIC. Process Control System PCS 7 Advanced Process Functions Operator Manual. Preface. Security information 1. Overview 2. Material management 3


Plant Security Services Protecting productivity in the digital era October

Setting up 08/2017. Setting up the SIMATIC IOT2000 SIMATIC IOT2020, SIMATIC IOT2040

SIMATIC. Industrial PC Microsoft Windows Embedded Standard 7. Safety instructions 1. Initial startup: Commissioning the operating.


Industrial Controls. Motor management and control devices SIMOCODE pro. Introduction 1. Configuring a reversing starter. List of abbreviations

SIMATIC. PCS 7 Process Control System SIMATIC Logon Readme V1.6 (Online) Security information 1. Overview 2. Notes on installation 3.

SIMATIC. Industrial PC Microsoft Windows 7. Safety instructions 1. Initial startup: Commissioning the operating. system

Setting up 01/2017. Setting up the SIMATIC IOT2000 SIMATIC IOT2020, SIMATIC IOT2040

Application example 02/2017. SIMATIC IOT2000 Connection to IBM Watson IoT Platform SIMATIC IOT2040

Data Storage on Windows Server or NAS Hard Drives

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example

SIMATIC NET. Industrial Remote Communication TeleService TS Gateway. Preface. Application and properties. Installation, commissioning and operation 2

Multiuser Engineering in the TIA Portal


Application example 12/2016. SIMATIC IOT2000 OPC UA Client SIMATIC IOT2020, SIMATIC IOT2040


SIMATIC. Process Control System PCS 7 Configuration Symantec Endpoint Protection V14. Security information 1. Preface 2.


Migration of a Process Historian database


SIMATIC Energy Suite Visualization example of the "*.csv"-energy Data Files

V90 controlled by EM253

RAID systems within Industry


Single Message Report for the Information Server. SIMATIC PCS 7, SIMATIC Information Server Siemens Industry Online Support


Siemens Drives & PLCs

Tabular SIMATIC BATCH report for the Information Server. SIMATIC PCS 7 / SIMATIC Information Server 2014 / Customized Reporting


Display of SINAMICS Error Messages in Runtime Professional

SIMATIC NET OPC Server Implementation


Display of SINAMICS Fault Messages in WinCC V7.4


Siemens Industrial SIMATIC. Process Control System PCS 7 Configuration Trend Micro OfficeScan Server XG. Security information 1.

Industrial Security Co-Sourcing: Shifting from CapEx to OpEx Presented by Vinicius Strey Manufacturing in America 03/22-23/2017

Integration of Process Historian / Information Server in a Domain

Visualizing Energy Data of a SITOP PSU8600

IO-Link Master (6ES7147-4JD00-0AB0) SIMATIC. ET 200pro IO-Link Master (6ES7147-4JD00-0AB0) Preface. Documentation guide. Product overview.

SIMATIC. SIMATIC Energy Manager V1.0 App for ios and Android. Preface. SIMATIC Energy Manager app. Establish connection to SIMATIC Energy Manager PRO

SIMATIC. Process control system PCS 7 Operator Station (V9.0 SP1) Security information 1. Preface 2


PNDriver V2.1 Quick Start Guide for IOT2040 SIMATIC IOT

SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Functions 1. Software installation 2. Operation. Configuration Manual

Message Cycle Report for the Information Server. SIMATIC PCS 7, SIMATIC Information Server Siemens Industry Online Support

SIMATIC. Process Control System PCS 7 Compendium Part D - Operation and Maintenance (V8.2) Security information 1. Preface 2

Check List for Programming Styleguide for S7-1200/S7-1500




SIMATIC. SIMATIC Logon V1.6. Security information 1. Conditions for secure operation of SIMATIC Logon 2. User management and electronic signatures 3

SIMATIC. PCS 7 Licenses and configuration limits (V9.0) Security information 1. Preface 2. Selecting the correct license keys 3

House Control with Touch Panel

Plant Automation Accelerator 2.1 Readme (Online)




Siemens AG Industrial Communication. SINEMA Server. Making your network transparent. Edition 09/2017. Brochure. siemens.

Transcription:

FAQ 02/2017 How to use a project file with an out of date firmware with actual firmware version SINAMICS V90 https://support.industry.siemens.com/cs/ww/en/view/109745062

This entry is from the Siemens Industry Online Support. The general terms of use (http://www.siemens.com/terms_of_use) apply. Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement and continuously maintain a holistic, state-of-the-art industrial security concept. Siemens products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks. Systems, machines and components should only be connected to the enterprise network or the internet if and to the extent necessary and with appropriate security measures (e.g. use of firewalls and network segmentation) in place. Additionally, Siemens guidance on appropriate security measures should be taken into account. For more information about industrial security, please visit http://www.siemens.com/industrialsecurity. Siemens products and solutions undergo continuous development to make them more secure. Siemens strongly recommends to apply product updates as soon as available and to always use the latest product versions. Use of product versions that are no longer supported, and failure to apply latest updates may increase customer s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under http://www.siemens.com/industrialsecurity. Table of content 1 Introduction... 3 1.1 Preliminary remark... 3 1.2 SINAMICS V-ASSISTANT... 3 2 How to use a project file with an out of date firmware with actual firmware version... 4 2.1 Issue Description... 4 2.2 Solution... 5 3 Contact... 8 4 History... 8 Entry-ID: 109745062, V1.0, 02/2017 2

1 Introduction 1 Introduction 1.1 Preliminary remark In a lot cases, the firmware in saved project file is different to the drive at customer site; for example, V1.05 in the project but V1.06 in the drive. When you try to go online with the save project file to make same parameter configurations into the drive, there is an error message reported. This frequently asked question (FAQ) will show you how to handle this problem. 1.2 SINAMICS V-ASSISTANT NOTE The latest version of SINAMICS V-ASSISTANT can be downloaded from the link below: https://support.industry.siemens.com/cs/ww/en/view/109738387 Currently SINAMICS V-ASSISTANT cannot support the operating system of Windows 8 and Windows 10. SINAMICS V-ASSISTANT engineering tool is designed for faster commissioning and diagnostics for SINAMICS V90 drive. The software runs on a personal computer with Windows operating systems and utilizes graphical user interface to interact with users and communicates with V90 drive via USB. It can be used to modify parameters and monitor status of SINAMICS V90 drive. Siemens AG 2017 All rights reserved Entry-ID: 109745062, V1.0, 02/2017 3

2 How to use a project file with an out of date firmware with actual firmware version 2 How to use a project file with an out of date firmware with actual firmware version 2.1 Issue Description The SINAMICS V90 firmware versions and corresponding V-ASSISTANT versions are as follows: Table 2-1 SINAMICS V 90 Firmware Version PTI V10400 PTI V10500 PTI V10600 PTI V10600, PN V10000 PTI V10700, PN V10002 Least Required V-ASSISTANT Version V1.01.00 V1.02.00 V1.03.00 V1.04.00 V1.05.00 NOTE The latest V-ASSISANT version is compatible with all the previous versions. For example, the firmware version in SINAMICS V90 currently is V10600 but the V- ASSISTANT project file has been saved with the firmware version of V10500. If you have updated V-ASSISTANT to V1.03.00 and open the project file, there will be an error message when you are trying to go online for integrating drive parameterizations into current drive: Figure 2-1 Entry-ID: 109745062, V1.0, 02/2017 4

2 How to use a project file with an out of date firmware with actual firmware version 2.2 Solution NOTICE Data lost! Please make a backup of your project file in case that there is a failure for following operations, which may result in data lost. To solve above-mentioned problem, you can proceed as followings: 1. Find the saved project file (for example, X.prj): Figure 2-2 2. Right-click the project file and open it with Notepad: Figure 2-3 Entry-ID: 109745062, V1.0, 02/2017 5

2 How to use a project file with an out of date firmware with actual firmware version 3. Currently the firmware value in the project file is 10500 : Figure 2-4 4. You can change this value to 10600 : Figure 2-5 5. Go online again to connect SINAMICS V90 and it will work. Entry-ID: 109745062, V1.0, 02/2017 6

2 How to use a project file with an out of date firmware with actual firmware version 6. When the connection finishes, there will be a dialog box popping-up: Figure 2-6 7. Click the button PC to drive to finish the data synchronization from the project file to current drive. Entry-ID: 109745062, V1.0, 02/2017 7

3 Contact 3 Contact Siemens Ltd., China DF M3-BF GMC No. 18 Siemens Road Jiangning Development Zone Nanjing, 211100 China mailto: mc_gmc_mp_asia.cn@siemens.com 4 History Table 7-1 Version Date Modifications V0.1 08/2016 First version Entry-ID: 109745062, V1.0, 02/2017 8