Surveillance Dell EMC Storage with Bosch Video Recording Manager

Similar documents
Surveillance Dell EMC Storage with Cisco Video Surveillance Manager

Surveillance Dell EMC Storage with Cisco Video Surveillance Manager

Surveillance Dell EMC Storage with Digifort Enterprise

Surveillance Dell EMC Storage with FLIR Latitude

Video Surveillance EMC Storage with Digifort Enterprise

Surveillance Dell EMC Storage with Verint Nextiva

Video Surveillance EMC Storage with Godrej IQ Vision Ultimate

Surveillance Dell EMC Storage with Milestone XProtect Corporate

Surveillance Dell EMC Storage with Synectics Digital Recording System

Video Surveillance EMC Storage with Honeywell Digital Video Manager

Video Surveillance EMC Storage with LENSEC Perspective VMS

Dell EMC SAN Storage with Video Management Systems

Surveillance Dell EMC Storage with IndigoVision Control Center

Dell EMC Storage with the Avigilon Control Center System

Dell EMC Storage with Panasonic Video Insight

Surveillance Dell EMC Storage with Genetec Security Center

Surveillance Dell EMC Storage with Synectics Digital Recording System

Surveillance Dell EMC Storage in Physical Security Solutions with Axis NAS-Attached Cameras

Dell EMC Storage with the Avigilon Control Center System

Dell EMC Storage with Milestone XProtect Corporate

Surveillance Dell EMC Storage with Aimetis Symphony

Video Surveillance EMC Storage with NUUO Crystal

Surveillance Dell EMC Storage with Infinova 2217 Security Management System

EMC STORAGE FOR MILESTONE XPROTECT CORPORATE

Video Surveillance EMC Storage with Genetec Security Center

Surveillance Dell EMC Storage with ISS SecurOS

Video Surveillance EMC Storage with LenSec Perspective VMS

Surveillance Dell EMC Storage with S-1 Video Management Software (SVMS)

Surveillance Dell EMC Storage with Milestone XProtect Corporate

Surveillance Dell EMC Storage with Honeywell Digital Video Manager

Dell Technologies IoT Solution Surveillance with Genetec Security Center

Surveillance Dell EMC Storage with Qognify

Dell EMC Storage with Genetec Security Center

DATA PROTECTION IN A ROBO ENVIRONMENT

Solution Overview. Surveillance Dell EMC Surveillance Validation Matrix. EMC VNX, EMC VNXe, and Dell EMC Isilon. H14530 REV 4.

Virtualizing SQL Server 2008 Using EMC VNX Series and VMware vsphere 4.1. Reference Architecture

Virtual Exchange 2007 within a VMware ESX datastore VMDK file replicated

EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH MICROSOFT HYPER-V

Solution Overview. Surveillance Dell EMC Surveillance Validation Matrix. Dell EMC Unity, Dell EMC SC series, Dell EMC Isilon andemc VNX,

Dell Technologies IoT Solution Surveillance with Genetec Security Center

EMC VSPEX END-USER COMPUTING

EMC Virtual Infrastructure for Microsoft Exchange 2010 Enabled by EMC Symmetrix VMAX, VMware vsphere 4, and Replication Manager

EMC VSPEX END-USER COMPUTING

Dell EMC Storage with Milestone XProtect Corporate

EMC Business Continuity for Microsoft Applications

Dell EMC Storage with Milestone XProtect Corporate

Surveillance Dell EMC Storage with LENSEC Perspective VMS

EMC VSPEX END-USER COMPUTING

EMC Performance Optimization for VMware Enabled by EMC PowerPath/VE

Dell EMC Storage with Verint Nextiva Configuration Guide

Dell EMC Unity Family

Surveillance Dell EMC Storage with Genetec Security Center

EMC Backup and Recovery for Microsoft SQL Server

Accelerating Microsoft SQL Server 2016 Performance With Dell EMC PowerEdge R740

EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH HYPER-V

Dell EMC. VxBlock Systems for VMware NSX 6.3 Architecture Overview

VMware vstorage APIs FOR ARRAY INTEGRATION WITH EMC VNX SERIES FOR SAN

Deploying VMware View in the Enterprise EMC Celerra NS-120. Reference Architecture.

EMC XTREMCACHE ACCELERATES VIRTUALIZED ORACLE

Surveillance Dell EMC Isilon Storage with Video Management Systems

Dell EMC Surveillance for Reveal Body- Worn Camera Systems

EMC Surveillance for Axon Commander

Dell EMC Surveillance for IndigoVision Body-Worn Cameras

Dell EMC. Vblock System 340 with VMware Horizon 6.0 with View

INTRODUCTION TO THE VVNX COMMUNITY EDITION

Data Protection at Cloud Scale. A reference architecture for VMware Data Protection using CommVault Simpana IntelliSnap and Dell Compellent Storage

EMC CLARiiON CX3-40. Reference Architecture. Enterprise Solutions for Microsoft Exchange Enabled by MirrorView/S

Physical Security EMC Storage with ISS SecurOS

EMC Backup and Recovery for Microsoft Exchange 2007 SP1. Enabled by EMC CLARiiON CX4-120, Replication Manager, and VMware ESX Server 3.

MIGRATING TO DELL EMC UNITY WITH SAN COPY

EMC Celerra NS20. EMC Solutions for Microsoft Exchange Reference Architecture

EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA

VMware Site Recovery Manager with EMC CLARiiON CX3 and MirrorView/S

EMC Integrated Infrastructure for VMware. Business Continuity

Surveillance Dell EMC Isilon Storage with Video Management Systems

Reference Architecture

Dell EMC Ready Architectures for VDI

Dell EMC. Converged Technology Extension for Isilon Storage Product Guide

EMC CLARiiON CX3-40. Reference Architecture. Enterprise Solutions for Microsoft Exchange 2007

EMC VSPEX END-USER COMPUTING

DELL EMC UNITY: BEST PRACTICES GUIDE

Maintaining End-to-End Service Levels for VMware Virtual Machines Using VMware DRS and EMC Navisphere QoS

VMAX3 AND VMAX ALL FLASH WITH CLOUDARRAY

Microsoft SharePoint Server 2010 on Dell Systems

VCP410 VMware vsphere Cue Cards

Dell EMC. VxRack System FLEX Architecture Overview

Dell TM PowerVault TM Configuration Guide for VMware ESX/ESXi 3.5

INTEGRATED INFRASTRUCTURE FOR VIRTUAL DESKTOPS ENABLED BY EMC VNXE3300, VMWARE VSPHERE 4.1, AND VMWARE VIEW 4.5

Dell EMC Surveillance for VIEVU Body- Worn Cameras

EMC CLARiiON CX3-80. Enterprise Solutions for Microsoft SQL Server 2005

Upgrade to Microsoft SQL Server 2016 with Dell EMC Infrastructure

Dell EMC PowerEdge R740xd as a Dedicated Milestone Server, Using Nvidia GPU Hardware Acceleration

EMC XTREMCACHE ACCELERATES MICROSOFT SQL SERVER

Dell EMC Unity: Data Reduction Analysis

Microsoft Office SharePoint Server 2007

Dell EMC. Converged Technology Extensions for Storage Product Guide

vstart 50 VMware vsphere Solution Specification

Dell EMC Microsoft Storage Spaces Direct Ready Nodes for VDI

Dell EMC Ready System for VDI on VxRail

Dell EMC Ready System for VDI on XC Series

Transcription:

Surveillance Dell EMC Storage with Bosch Video Recording Manager Sizing and Configuration Guide H13970 REV 2.1

Copyright 2015-2017 Dell Inc. or its subsidiaries. All rights reserved. Published December 2015 Dell believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. THE INFORMATION IN THIS PUBLICATION IS PROVIDED AS-IS. DELL MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. USE, COPYING, AND DISTRIBUTION OF ANY DELL SOFTWARE DESCRIBED IN THIS PUBLICATION REQUIRES AN APPLICABLE SOFTWARE LICENSE. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be the property of their respective owners. Published in the USA. Dell EMC Hopkinton, Massachusetts 01748-9103 1-508-435-1000 In North America 1-866-464-7381 www.dellemc.com 2 Dell EMC Storage with Bosch Video Recording Manager Sizing and Configuration Guide

CONTENTS Chapter 1 Introduction 5 Solution overview... 6 Purpose...6 Scope... 6 Audience... 6 Key recommendations... 6 Chapter 2 Solution components 9 Dell EMC arrays and clusters... 10 Storage protocols... 10 Bosch Video Recording Manager... 10 Chapter 3 Configuring the solution 13 BVMS architecture... 14 EMC VNX and EMC VNXe... 14 Tested architectures...16 Cameras writing to the virtual iscsi disks created on the Windows Server 2012 iscsi gateway... 16 Configuring the solution... 17 VNX and VNXe family sizing and configuration... 18 Minimum requirements and recommendations... 19 Chapter 4 Testing and validation 21 Test objectives... 22 Test parameters... 22 Testing storage bandwidth and configuration...22 Chapter 5 Conclusion 25 Summary... 26 Dell EMC Storage with Bosch Video Recording Manager Sizing and Configuration Guide 3

CONTENTS 4 Dell EMC Storage with Bosch Video Recording Manager Sizing and Configuration Guide

CHAPTER 1 Introduction This chapter provides an introduction to this solution. Solution overview...6 Purpose...6 Scope...6 Audience... 6 Key recommendations...6 Introduction 5

Introduction Solution overview This solution uses EMC VNX and EMC VNXe storage systems with VMware ESXi hosts running Bosch Video Management System (BVMS), Bosch Video Recording Manager (VRM), and Microsoft iscsi Gateway Servers. Purpose Scope Audience You can use this document to determine the requirements for a successful BVMS installation. This document also provides guidelines for sizing the Dell EMC storage arrays. The sizing recommendations are based on performance and storage protocols derived from Dell EMC testing. This document focuses on guidelines for storage array positioning and sizing for a customer's specific system design requirements. The scope of this document includes: Bandwidth recommendations for Bosch VRM release 3.0 or later and one or more Dell EMC systems. Bosch VRM version 3.0.0073 was tested for these guidelines Several Dell EMC storage system configurations that are ideal for physical security solutions with BVMS Results summary of the Dell EMC performance tests described in this document By using this document. you can determine the best configuration, including: Number of Bosch VRMs and number of Windows 2012 Gateway Servers required for a customer's solution Storage access protocol configurations for the iscsi protocol Load factors for building Dell EMC storage arrays for a customer's solution All performance data contained in this report was obtained in a rigorously controlled environment. Performance varies depending on the specific hardware and software and may be different from what is outlined here. The intended audience for this document includes internal Dell EMC sales and presales personnel. Key recommendations You can use the guidelines in this white paper to do the following through the Microsoft iscsi gateway: Determine the recorder services maximum bandwidth for the Dell EMC storage arrays. 6 Dell EMC Storage with Bosch Video Recording Manager Sizing and Configuration Guide

Introduction Measure sizing needs for Dell EMC storage options to correctly size the implementation with Dell EMC products that match the customer s requirements. Determine the VNX or VNXe bandwidth for each LUN. Determine the disk pool and LUN configurations. Recommend the applicable disk drive types Key recommendations 7

Introduction 8 Dell EMC Storage with Bosch Video Recording Manager Sizing and Configuration Guide

CHAPTER 2 Solution components This chapter describes the components for this solution. Dell EMC arrays and clusters... 10 Storage protocols... 10 Bosch Video Recording Manager... 10 Solution components 9

Solution components Dell EMC arrays and clusters Storage protocols Dell EMC storage systems are ideal for storing video and audio data. This document describes tests for each of the following systems: This document describes tests for each of the following systems: EMC VNX EMC VNXe All collection scenario tests were performed with at least one failed or recovered component. We 1 performed our testing with both single and dual storage processors on a VNX storage system with disk recovery processes for all systems. This document provides information about the following network protocols: iscsi Bosch Video Recording Manager A BVMS installation can consist of a single server and is a management superset of VRM. The VRM provides base level system-wide recording, monitoring, and management of Bosch iscsi storage, video servers, and cameras for a BVMS. You can configure VRM to manage a few cameras or thousands of cameras. The iscsi disk arrays are not attached directly to a VRM, but instead can be attached anywhere on a standard IP network through a 1 GbE uplink. The following table describes four primary Video Management System services. Table 1 BVMS primary services Service Video Recording Manager(VRM) Server VRM Monitor Configuration Manager Description VRM Server manages the recordings of the devices, configuration details, and system settings, and acts as a centralized service for communicating with individual modules. Cameras can record and store the video to the iscsi virtual disks. The virtual disks are created on an iscsi LUN that is mounted as a drive on a Windows 2012R2 server. The VRM Monitor module monitors the VRM system. This module is where information about the connected Bosch Video over IP (BVIP) devices, storage systems, and recordings is displayed. The module also monitors online and offline storage, the system health status for cameras, and any problems with the system. Use Configuration Manager to configure the VRM system. The program can be installed on one or more Windows PCs that provide network access to the computer on which VRM Server has been started. This program enables you to specify 1. In this document, "we" refers to the Dell EMC Surveillance Lab team that tested and validated this solution. 10 Dell EMC Storage with Bosch Video Recording Manager Sizing and Configuration Guide

Solution components Table 1 BVMS primary services (continued) Service Description the IP cameras and encoders for each recording, as well as which iscsi storage systems are used to store the recordings. Bosch Video Client Bosch Video Client is a Windows PC application for live viewing and playback of network-connected cameras, and the search and export of recorded video. Note The VRM comprises Bosch Video Streaming Gateway software. The solution validated in the Dell EMC Surveillance Lab is based on cameras writing through a Microsoft iscsi gateway. The Bosch video streaming gateway was not tested. The Microsoft iscsi gateway is a term that Bosch uses to describe Microsoft's iscsi target, which allows Windows Server to present itself as an iscsi disk array. Although the iscsi target was available for Windows Server 2008, it was not incorporated into Windows Server until the 2012 release. Bosch Video Recording Manager 11

Solution components 12 Dell EMC Storage with Bosch Video Recording Manager Sizing and Configuration Guide

CHAPTER 3 Configuring the solution This chapter describes how to configure the solution. BVMS architecture... 14 EMC VNX and EMC VNXe...14 Tested architectures... 16 Cameras writing to the virtual iscsi disks created on the Windows Server 2012 iscsi gateway... 16 Configuring the solution...17 VNX and VNXe family sizing and configuration...18 Minimum requirements and recommendations...19 Configuring the solution 13

Configuring the solution BVMS architecture There are many design options for a BVMS implementation, and Bosch offers many training courses related to design and implementation. These design details are beyond the scope of this paper. The Bosch VRMUser Manual Video Re-Operation Guide provides the necessary information to plan a BVMS. The data sheet on the Bosch Video Client provides a detailed explanation of how to use the video client application. The Bosch Video Management System 3rd Party Storage document provides a detailed explanation of how to create iscsi virtual disks on iscsi targets on a Microsoft Windows 2012R2 server. Note The size of a single LUN assigned on the Bosch VRM under iscsi System cannot exceed 2000 GB (or 2 TB); otherwise problems will occur when the LUN is formatted with Configuration Manager. These documents are available from a Bosch partner or through the Bosch Partner network. They are intended for systems integrators, architects, network IT planners, and system administrators. They assume readers know what BVMS software does, how it works, and how to deploy and configure Windows IP networks. This white paper is not intended to replace or supersede any Bosch document. The following figure represents the basic configuration that we tested for this solution. Figure 1 Solution configuration EMC VNX and EMC VNXe This section describes best practices for configuring a VNX or VNXe environment for the solution. For further details about best practices on VNX and VNXe, refer to the Performance Best Practices Guide of the appropriate storage system. Flash drives (not recommended) Due to the high percentage of sequential large block writes, we do not recommend the use of flash drives for video storage within a surveillance application. Disk drives Although any supported drive will work, video surveillance systems typically rely on the density of the storage system. We recommend Near Line (NL)-SAS drives of the highest available density in this solution. In general, we used terabyte (TB) or multiple TB NL-SAS drives when performing tests. 14 Dell EMC Storage with Bosch Video Recording Manager Sizing and Configuration Guide

Configuring the solution Storage pools (recommended) The tests we conducted with BVMS confirm that storage pools, defined with the maximum allowable number of disks per pool, perform as well as, or better than, traditional RAID groups, and we therefore recommend that you use storage pools. Storage pools also reduce the required storage-system management tasks. Building a storage pool is a straightforward process. You can configure either RAID 5 or RAID 6, depending on the VNX family member restrictions and the risk factors that the customer is willing to accept. When configuring storage pools, use large storage pools with large-sized LUNs and configure the LUNs as "thick" instead of "thin." Background zeroing (recommended) Background zeroing erases any data previously written to the drive. All drives for newly bound LUNs and new Virtual Provisioning pools are zeroed. New drives come from the factory pre-zeroed. Cameras that start writing to the Bosch storage while background zeroing is in progress will have performance issues. We recommend not starting any recording from the Bosch VRM until the zeroing process is complete. The zeroing rate varies between 20 MB/s and 50 MB/s, depending on the drive type, and the zeroing process can adversely affect storage performance, particularly when many LUNs or maximumsize storage pools are created simultaneously. If the drives have been used previously, the zeroing process can be accelerated by manually pre-zeroing drives before binding or pool creation. VNXe RAID configurations We recommend the following RAID configurations: RAID 5 or RAID 10 with SAS drives RAID 6 with NL-SAS drives (recommended) Note Do not use flash drives. See the Flash drives (not recommended) section for details. Bosch iscsi initiators Bosch VRM works based on the Bosch-defined iscsi initiator addresses for the IP cameras, Bosch VRM server, and the iscsi storage pools. To configure working iscsi storage, you need to add an iscsi system and assign the LUNs. Microsoft iscsi gateway We used Microsoft Windows Server 2012 64-bit iscsi target and iscsi software initiators in this solution, which act as a gateway server between VNX or VNXe storage, the cameras, and Bosch VRM. iscsi software initiators are 64-bit initiators. Microsoft Windows Server 2012 R2 or later supports the creation of iscsi target and iscsi virtual disks which can be assigned as LUNs on the Bosch VRM for the cameras to write to. Note At the time of publication, we had not tested the Cisco UCS unified adapter iscsi capabilities. This solution does not support Microsoft software initiators on Microsoft Windows Server prior to Windows Server 2012R2. EMC VNX and EMC VNXe 15

Configuring the solution Tested architectures In the Dell EMC Surveillance Lab, writes to the VNX or VNXe storage systems are tested using the following two methods: Cameras writing directly to the VNX or VNXe raw iscsi LUNs assigned using Bosch-defined IQN addresses. Based on test results, this configuration is not recommended. Cameras writing to the virtual iscsi disks created on an iscsi or Fibre Channel (FC) disk drive mounted on the Microsoft Windows iscsi Gateway Server Cameras writing to the virtual iscsi disks created on the Windows Server 2012 iscsi gateway Due to the limitation with the direct iscsi LUN architecture and errors with cameras writing to the VNX iscsi LUNs, Bosch and Dell EMC found a way to improve camera write performance to the VNX or VNXe storage systems when using Bosch Video Management Systems. This architecture uses Windows 2012R2 64-bit Server as Microsoft Gateway Server between VNX or VNXe using iscsi or FC, the cameras and the VRM. In this architecture, iscsi or FC LUN size can be any size supported by VNX or VNXe storage systems and can be mapped on the Gateway Server using Microsoft iscsi Initiator addresses. Once the LUN is formatted as a disk drive on the Gateway Server, we can create an iscsi target and as many virtual iscsi disks as we need on the disk drive. Note Each virtual iscsi disk size should not exceed 2000 GB as the Bosch VRM does not support LUNs greater than 2000 GB The maximum LUN size that can be created on a VNX5300, VSS-100, or VNXe3200 is 16 TB. The advantages in using this architecture are: The iscsi connection between VNX or VNXe and the Gateway Server is the Microsoft Software iscsi, which has been validated and shown to work well with the Dell EMC storage systems. If FC is used, raw LUNs can be mapped as disk drives. Note In the Dell EMC Surveillance Lab, tests were conducted using the iscsi protocol. The FC protocol has been tested for compatibility with the Bosch VRM and worked as good or better than the iscsi protocol. The cameras and VRM do not need an iscsi connection to the VNX or VNXe storage systems, thus reducing the number of I/O events happening concurrently through the separate connections. This had a significant impact on the write performance, and iscsi write errors and iscsi connection errors were reduced significantly. With this configuration, we are able to test the VNX VSS-100 storage system at the bandwidth of 322 MB/s on single SP, using 512 CIF cameras with each camera of 5 Mbps bandwidth. 16 Dell EMC Storage with Bosch Video Recording Manager Sizing and Configuration Guide

Configuring the solution Configuring the solution To configure the solution: Procedure 1. Before creating a storage pool, run disk pre-zeroing for all VNX systems that will store data. naviseccli zerodisk -messner <disk-id> <disk-id> <disk-id> start naviseccli zerodisk -messner <disk-id> <disk-id> <disk-id> status 2. Assign the IP addresses to the active and passive ports on the iscsi NICs of VNX or VNXe that will be used for I/O with Microsoft iscsi Gateway Server. 3. Create a storage pool with a maximum number of disks and create LUNs of the required size for Microsoft iscsi Gateway Server. For example, in the Dell EMC Surveillance Lab, we created 16 TB LUNs, the maximum size supported on the VNX5300 and VSS-100. 4. Register the Microsoft iscsi initiator address for the Gateway Server on which the LUN needs to be mounted as a disk drive. 5. Create a storage group on the VNX and connect LUNs and hosts to the storage group. 6. Format the raw LUN on the Gateway Server and create target and virtual iscsi disks (vdisks). Each vdisk needs to be less than 2000 GB. Wait until the vdisk creation process is complete. For detailed steps, refer to the Bosch Video Management System 3rd Party Storage document, which explains how to create an iscsi target and virtual iscsi disks on the Microsoft iscsi Gateway Server. For example, in the Dell EMC Surveillance Lab, we created a target on the same server and eight vdisks, each with a size of 1950 GB. 7. Allocate the cameras to the VRM using Device Allocator, which is managed and recorded to the VNX iscsi storage. 8. Add the Gateway Server address on the Bosch VRM as the iscsi System. 9. Assign the vdisks available to the VRM using LUN Assignment so that cameras can write to the vdisks. 10. Change the Max. Number of iscsi sessions and Max. Bit rate [Mbps] from the default based on the customer requirements and the supported values for Bosch VRM. 11. Set the Recording Preferences for the cameras by selecting the required iscsi system as Primary Target and Secondary Target under Camera > Recording > Recording Profiles. 12. Set the Maximum Retention Time and Minimum Retention Time under Camera > Recording > Recording Profiles. 13. Start and stop the camera recording by using the button under Devices > Recording > Recording Scheduler. Configuring the solution 17

Configuring the solution 14. Use the VRM monitor to monitor the camera recording, status of the cameras, number of LUNs, number of cameras, remaining space, bandwidth of camera recording, and so on. VNX and VNXe family sizing and configuration The following table presents the various measurements we took while testing Video Management System across selected VNX or VNXe family storage arrays. When implementing the solution in the Dell EMC Surveillance Lab, the following sizing guide was derived using a 16 TB per Microsoft iscsi Gateway Server, each eight 2 TB vdisks were created per LUN. The storage was configured with a single storage pool. Table 2 VNX or VNXe sizing guide Storage array Disks Array bandwidth VNXe1600* 35 256 VNXe3200 120 210 VNX-VSS100 90 381 VNX5200* 55 360 VNX5400* 120 476 VNX5600* 120 500 240 800 VNX5800* 500 800 120 530 240 847 360 1271 VNX7600* 750 1271 120 547 240 876 360 1314 480 1752 VNX8000* 1000 1752 120 655 240 1047 360 1571 480 2094 600 2618 1000 2618 * The disks used in the Dell EMC Surveillance Labs are NL-SAS, 7200 rpm unless otherwise stated. 18 Dell EMC Storage with Bosch Video Recording Manager Sizing and Configuration Guide

Configuring the solution Firmware at time of tests The following table lists the firmware builds used in these tests. Expect equal or better results if you use more recent firmware or newer models of VNX or VNXe storage. Table 3 Firmware builds Model Firmware VNX5300 VNX OE 5.32.000.5.206 VNX-VSS100 VNX OE 5.32.000.5.215 VNXe3200 VNXe OE 3.1.1.5395470 Minimum requirements and recommendations Refer to the installation guide for your VMS version to find the minimum and recommended hardware specifications. Video Management System Different VMS server types have different hardware specifications that include the processor speed and type, memory specifications based on the processor, storage concerns, and Ethernet NICs. Refer to the VMS installation guide for the VMS version you are implementing for software and operating system requirements. VMware ESX and ESXi VMware vsphere minimum system requirements are as follows: VMware ESX and ESXi 4.0 or later Four-core 1.99 GHz processors or greater 6 GB of memory for each vsphere guest running a VMS server Dell EMC PowerPath for block storage For a list of compatible hardware, refer to the VMware Compatibility Guide. Tested vcpu, memory, and network Our test environment had the following configuration: VMware ESXi 5.1 Update 1 and ESXi 5.5 20-core ESXi host at 2.2 GHz or greater 128 GB or greater memory per ESXi 5.1 host Each virtualized Bosch host featured: Eight (8) virtual CPUs (vcpu) 8 GB memory Network adapter type: VMXNET3 Private VLAN for storage Dedicated vnic for storage Storage adapter requirements The following are the storage adapter requirements: All storage adapters must be VMware certified. If used, FC and iscsi adapters must be VMware and Dell EMC certified. The following table shows the requirements for each of the storage types. Minimum requirements and recommendations 19

Configuring the solution Table 4 Storage requirements Storage type Datastore Video storage Requirements DAS or SAN devices and a minimum of 80 GB for each virtual machine SAN devices with unpartitioned space (VMware raw) and iscsi-attached 20 Dell EMC Storage with Bosch Video Recording Manager Sizing and Configuration Guide

CHAPTER 4 Testing and validation This chapter presents the findings from our testing. Test objectives...22 Test parameters...22 Testing storage bandwidth and configuration... 22 Testing and validation 21

Testing and validation Test objectives Test parameters Many factors should be taken into account when you are designing your solution using the Microsoft iscsi gateway solution. The Dell EMC Surveillance Lab tests focus on storage-related factors with the following objectives: Determine the bandwidth for various Dell EMC storage systems with iscsi. Determine the configuration parameters for VNX or VNXe storage. Determine optimal performance requirements for use with VNX or VNXe storage arrays based on various failure scenarios. Determine the maximum bandwidth with multiple Windows iscsi gateway servers. The following test parameters were used for performing tests of Bosch VMS: Tests were conducted by loading each Microsoft iscsi gateway server at a bandwidth of 80 MB/s with 128 CIF cameras. Note 80 MB/s (640 Mb/s) is the maximum recommended bandwidth. All test measurements were based on active failure scenarios. Failure scenarios include drive failures and recovery and storage processor failures. Testing with these realistic scenarios helps ensure a successful implementation that can withstand various types of failures. The IP network is a flat (Layer 2), high availability network with plenty of capacity, which allowed us to focus on the products we were testing. All tests assumed uniform distribution of bandwidth from the Video Management System Recorders. Testing storage bandwidth and configuration The storage bandwidth test evaluated video storage and applications with several different Dell EMC storage systems. Additional tests evaluated ESXi host hardware in relationship to vcpu settings and the resulting bandwidths. Before you begin These tests assumed that the Bosch Video Management System was configured as described in Bosch's best practices and operated within the recommended bandwidth, camera count, and other Bosch maximum requirements. Procedure 1. Configured the video storage for a Dell EMC storage system. 2. Configured Bosch VRM for the iscsi storage protocol to be tested. 3. Set up camera simulators (traffic generators) to produce a traffic load to each Microsoft iscsi gateway server at the recommended bandwidth. 4. Verified that motion detection was set to On for all cameras. 22 Dell EMC Storage with Bosch Video Recording Manager Sizing and Configuration Guide

Testing and validation 5. Evaluated the network and video storage to ensure an error-free environment at the induced bandwidth. 6. Introduced storage device errors, including: Disk failures and rebuilds on VNX and VNXe The use of only one VNX or VNXe storage processor 7. Captured the storage system and host statistics. 8. Based on the test results: If no issues were detected, we incremented the bandwidth. If issues were detected, we decremented the bandwidth. Repeated previous step until the maximum, error-free, bandwidth was reached. Testing storage bandwidth and configuration 23

Testing and validation 24 Dell EMC Storage with Bosch Video Recording Manager Sizing and Configuration Guide

CHAPTER 5 Conclusion This section presents a summary of our findings. Summary...26 Conclusion 25

Conclusion Summary VNX arrays As compared to traditional block-level storage, the use of storage pools to create LUNs within the VNX storage systems greatly simplifies the configuration and increases performance. iscsi can be implemented for this solution. VNX-VSS arrays The VNX-VSS is a storage solution that is purpose built to meet the unique demands of the video surveillance environment. We found that this high availability, low cost array performs comparably to other arrays in the VNX family. VNXe arrays The iscsi-connected VNXe, implemented with storage pools, provides a costeffective implementation while maintaining expected performance levels. VNXe may be used in many midsized deployments. 26 Dell EMC Storage with Bosch Video Recording Manager Sizing and Configuration Guide