LBP2 Series. 1X Image Converter P/N LBP2-UVIMG with Optional Beam Splitter P/N LBP2-UVBS. Laser Beam Analyzer. For Windows 7

Similar documents
LPM Series. LPM Series User s Manual

LBP2-SAM Series Beam Sampler for C-mount Cameras. User Notes

4X Beam Expander P/N SPZ17022 and Optional Beam Splitter P/N SPZ17027 User Notes

MDL Series Motorized Variable Optical Delay Line

LQx and RLx Series User s Manual

Fiber Optic Prism Switch USER S MANUAL

Model 1931/2931 Series Model 1936/2936 Series

1919-R 1919-R. Laser Power / Energy Meter User Manual. NEWPORT CORPORATION

1919-R 1919-R. Laser Power / Energy Meter User Manual. NEWPORT CORPORATION

OPERATOR S MANUAL FPD 50 WATT POWER SUPPLY. Flat Pack Single Output DC to DC Converter 50 Watt Output 24 Vdc Nominal Input

WAVELENGTH MANAGEMENT

WAVELENGTH MANAGEMENT

Instructions. Remote Controlled Rotator RCR

±15 V Current-Limited Power Supply

SVP48 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

Universal Switch Panel USP-KEYSERVER. User Manual

FA-2448 SIX POSITION Filter Wheel

MicroCure And MicroCure Plus Instruction Manual

SVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

VIP-812A DUAL NETWORKED STATION PORT

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

TABLE OF CONTENTS PRODUCT DESCRIPTION CINCAM CCD TECHNICAL DATA SENSOR RESPONSE DIMENSIONS CINCAM CCD LARGE FORMAT TECHNICAL DATA SENSOR RESPONSE

DP-222Q Color Video Door Phone Manual

PCMCIA Flash Card User Guide

What s in the box. SUP paddle sensor. Paddle sensor mounting track. Charger. USB cable. In your Motionize SUP kit you will find:

LED..O..M Series Diffused On-Axis Lights

Global Water Instrumentation, Inc.

Pro Isolation Chamber for Recording Microphones

Beam Profile Wavelength Temporal Profile

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK

DP-222Q Color Video Door Phone Manual

3-Lamp Fluorescent Ring Light 19" INSTRUCTIONS

Instructions. RM3000 Rackmount Kit for TDS3000 Series Oscilloscopes

V-9939B MICROPHONE ADAPTER

SC32A OPTICALLY ISOLATED RS232 INTERFACE INSTRUCTION MANUAL

OL-KT. Online Connection Kit Installation Manual

DP-234Q (NTSC) DP-734Q (PAL) Hands-Free Video Door Phone Manual

INSTRUCTION MANUAL. SGB20(D) Transient Protection System. June Copyright 2008 Campbell Scientific (Canada)Corp.

Model 764H Series. High Power LD Mount. User s Manual

Installation Guide for Flex Tap

4" AMPLIFIED RECESSED CEILING SPEAKERS 8" AMPLIFIED RECESSED CEILING SPEAKERS

AMERICA S PREMIER EXERCISE EQUIPMENT RCD-347. Chin-Dip / Ab-Back / Push-Up Stand. TuffStuff Fitness Equipment, Inc. 83 3/4" 43 1/4" 44 3/4"

Rackmount Keyboard Installation Instructions. Revision A A-0000

Wall. No opening (Example: LA-030-W)

C10-UM Universal Indoor Camera Mount

4620, Quick Start

V-9941A ONE ZONE HANDSFREE TALKBACK CONTROL UNIT

GVIS Video Inspection Scope

HeadMouse Extreme. Bracket Installation Instructions for DynaVox Maestro. Additional Resources. Bracket Installation Instructions for Maestro

MITSUBISHI ELECTRONICS AMERICA, INC.

OPERATION MANUAL SERIES MICRO BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085

OPERATIONS MANUAL PCM-DOC

V CHANNEL MODULAR PRE-AMP/MIXER V-9984 REMOTE INPUT MODULE V CHANNEL MODULAR PRE-AMP/MIXER

Fantasea Blue Ray Tray (Cat. No. 2040, 2045, 2050) Instruction Manual

Instruction Sheet. PCS Series. Fiber\Cable Management Spool

ACCELERATOR LENS ADAPTER

GageWay KW Keyboard Wedge

Contents. Warranty... Pg. 4. Assembly Option 1 : Upright... Pg Ladder Installation... Pg. 11. Assembly Option 2 : Upside down... Pg.

ACCU-SCOPE INC. 73 Mall Drive Commack, NY Phone: (631) Fax: (631)

OPERATION MANUAL SERIES BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085

PV Series. Owner s Manual. Photo Tripod

PalmScan P2000 FastPach User Guide

HD-SDI Vandal Dome Camera

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V

V-9964 Digital Feedback Eliminator/Message Stacker

VIP-480AL IP One-Way Horn

NOTE: The F2 button and the 4 LED annunciators do not function on the LD-ACF-I. To use these features, ask about the LD-ACF-R4/R4A.

12 Digital Photo Frame Instructional Manual

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

RS-600AF RS-850AF RS-1200AF. Camera. Track Slider. With Adjustable Feet

Installation Guide for Fiber Tap HD8

V-9964 Digital Feedback Eliminator/Message Stacker

62532 (EN649) Ethernet Adapter

MPP200 User s Manual

VCMDM MODEM INSTALLATION INSTRUCTIONS

VIP-148AL IP Talkback Horn

RS422 PORT SWITCHER REMOTE CONTROL PANEL

OptiView 250 OV-250 LCD VIEWFINDER USER MANUAL

GageWay SM. Copyright MicroRidge Systems, Inc.

10 Digital Photo Frame Instructional Manual

Universal Tablet Holder

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

MACROFIER Reverse Mount and Extension Tube with Automatic Functionality for Canon EOS Lenses. User Manual

AEXX-349 SERIES REMOTE DISPLAYS

Enable-IT 821 Ethernet Extender Quickstart Guide Professional Grade Networking

AMERICA S PREMIER EXERCISE EQUIPMENT RAB-336. Abdominal / Back Bench. TuffStuff Fitness Equipment, Inc. 46" 61 3/4" 44 1/4"

USB-A to Serial Cable

FLEXIBLE MACRO BRACKET WITH ARCA-STYLE MOUNT. User Manual

Indicator (Square) Ultra Bright LED Type

VIS Video Inspection Scope

D. Instruction Manual and Experiment Guide for the PASCO scientific Model OS-8523 SLIT ACCESSORY FOR THE BASIC OPTICS SYSTEM

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

10 Slim Digital Photo Frame Instructional Manual

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

20W Tungsten-Halogen Light Source. Operation Manual

CAT U S E R M A N U A L

OWNER S MANUAL RLE-382 AMERICA S PREMIER EXERCISE EQUIPMENT. Seated leg ext / curl bench RLE-382 L 61 W 44 H 38

CONTENDER LED FRESNEL SPOT FOCUSING LIGHT USER MANUAL

Transcription:

LBP2 Series 1X Image Converter P/N LBP2-UVIMG with Optional Beam Splitter P/N LBP2-UVBS Laser Beam Analyzer For Windows 7 Document No 50374-001 Page 1 of 7 Rev A 05/2016

Warranty Newport Corporation warrants that this product will be free from defects in material and workmanship and will comply with Newport s published specifications at the time of sale for a period of one year from date of shipment. If found to be defective during the warranty period, the product will either be repaired or replaced at Newport's option. To exercise this warranty, write or call your local Newport office or representative, or contact Newport headquarters in Irvine, California. You will be given prompt assistance and return instructions. Send the product, freight prepaid, to the indicated service facility. Repairs will be made and the instrument returned freight prepaid. Repaired products are warranted for the remainder of the original warranty period or 90 days, whichever first occurs. Limitation of Warranty The above warranties do not apply to products which have been repaired or modified without Newport s written approval, or products subjected to unusual physical, thermal or electrical stress, improper installation, misuse, abuse, accident or negligence in use, storage, transportation or handling. This warranty also does not apply to fuses, batteries, or damage from battery leakage. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE. NEWPORT CORPORATION SHALL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES RESULTING FROM THE PURCHASE OR USE OF ITS PRODUCTS. First printing 2016 2016 by Newport Corporation, Irvine, CA. All rights reserved. No part of this manual may be reproduced or copied without the prior written approval of Newport Corporation. This manual has been provided for information only and product specifications are subject to change without notice. Any change will be reflected in future printings. Newport Corporation 1791 Deere Avenue Irvine, CA, 92606 USA Document No 50374-001 Page 2 of 7 Rev A 05/2016

Technical Support Contacts North America Newport Corporation Service Dept. 1791 Deere Ave. Irvine, CA 92606 Telephone: (949) 253-1694 Telephone: (800) 222-6440 x31694 Asia Newport Opto-Electronics Technologies (Wuxi) Co., Ltd 理波光电科技 ( 无锡 ) 有限公司江苏省无锡市新区出口加工区 J3-8 厂房 204028 Lot J3-8, Wuxi Export Processing Zone, New District, Jiangsu China 204028 Telephone: +86-510-8113 2999 Fax: +86-510-8526 9050 Newport Corporation Calling Procedure Europe Newport/MICRO-CONTROLE S.A. Zone Industrielle 45340 Beaune la Rolande, FRANCE Telephone: (33) 02 38 40 51 56 If there are any defects in material or workmanship or a failure to meet specifications, promptly notify Newport's Returns Department by calling 1-800-222-6440 or by visiting our website at www.newport.com/returns within the warranty period to obtain a Return Material Authorization Number (RMA#). Return the product to Newport Corporation, freight prepaid, clearly marked with the RMA# and we will either repair or replace it at our discretion. Newport is not responsible for damage occurring in transit and is not obligated to accept products returned without an RMA#. E-mail: rma.service@newport.com When calling Newport Corporation, please provide the customer care representative with the following information: Your Contact Information Serial number or original order number Description of problem (i.e., hardware or software) To help our Technical Support Representatives diagnose your problem, please note the following conditions: Is the system used for manufacturing or research and development? What was the state of the system right before the problem? Have you seen this problem before? If so, how often? Can the system continue to operate with this problem? Or is the system nonoperational? Can you identify anything that was different before this problem occurred? Document No 50374-001 Page 3 of 7 Rev A 05/2016

Notice All rights to the product and any accompanying user guide(s) are reserved by Newport Corporation. Newport Corporation reserves the right to make improvements to the product described in this user guide at any time and without prior notice. While every precaution has been taken in the preparation of this guide, the publisher and author assume no responsibility for errors, omissions, or any loss of data because of said errors or omissions. Personal computer hardware and component manufacturers, along with operating system providers constantly revise their products and software upon which this product is dependent. While Newport Corporation endeavors to maintain maximum compatibility with a wide variety of personal computer configurations, Newport Corporation makes no guarantee that any one brand or model of personal computer will be compatible with any or all of the features contained in this application, either now or in the future. Obtain the latest version of this user guide at the product page in www.newport.com Document No 50374-001 Page 4 of 7 Rev A 05/2016

1X UV Image Converter (P/N LBP2-UVIMG) With Optional Beam Splitter (P/N LBS2-UVBS) User Notes The 1X Image Converter is an attachment to a beam profiler camera that enables it to operate better in the UV from 157nm to 360nm. The 1X Image Converter operates as follows (see diagram): The UV beam falls on the fluorescent plate which fluoresces in the visible. The fluorescent plate is transparent to the visible light but not the UV (1). Thus only the bright fluorescing image is seen by the camera. The optical system images the beam plane onto the CCD of the camera, keeping the image size the same as the object size. Replaceable ND filters are chosen by the user to optimize the light level on the camera to give maximum dynamic range without the light saturating the CCD. Beam profiler Camera Screw on ND Filters 8mm Spacer for 4.5mm spacing cameras UV laser beam converted to visible light CCD Imaging System Visible image on CCD Fluorescent plate 1. Attaching the 1X Image Converter to the beam profiler camera 1. Unscrew any filters on the beam profiler camera. 2. If the camera is a camera with 4.5mm back focal spacing (from the front of the camera to the CCD), leave the 8mm spacer on the converter. If you are using a camera with a CS mount having spacing of 12.5mm to the CCD, remove the 8mm spacer. Note: This device will not work with cameras that have a fixed C-mount spacing of 17.5mm. 3. If the energy density on the UV plate is larger than ~8mJ/cm², use the red ND filter attenuator. If the energy density is lower than this, use the empty (no ND glass inside) spacer. Note that these values are approximate and if in doubt, experiment to see which way gives an image with the best signal-to-noise without saturating the camera. Note also that for energy densities greater than the saturation of the UV plate (~15mJ/cm² at 193nm and ~25mJ/cm² at 248nm) you should use the optional beam splitter to reduce the UV light level on the phosphor plate to below saturation. 4. Screw the converter as assembled onto the camera until it is tight. Document No 50374-001 Page 5 of 7 Rev A 05/2016

5. Center the laser beam onto the fluorescent plate. If you have purchased the beam splitter for higher energy density beams, mount the beam splitter to the barrel of the X1 image converter behind the locking nut as shown. Optional wedge beam splitter (SPX17015) Focusing barrel for UV plate ND Filter 8mm Spacer for 4.5mm back focal cameras Locking ring for focusing barrel Locking ring for beam splitter X1 UV Image Converter with beam splitter option on a Spiricon camera Camera function is similar with both LBA and BeamGage software. Consult the respective operator s manuals to learn how to setup the system for either pulsed or CW mode whichever applies. Since UV converters are commonly used with pulsed Excimer lasers the following example discusses pulsed mode operation. The UV converter works best in darkened room light. 2. Operating the Image Converter with a Pulsed Laser Beam 1. The 1X converter may slightly reduce or magnify the imaged beam, thus the scaling values in the software may need to be adjusted to compensate for this error. The magnification number shown on the barrel of the converter will tell you if the beam is slightly larger or smaller. Use this factor as needed in BeamGage or LBA to adjust the spatial results computations. 2. Center the laser beam on the fluorescent plate at the entrance of the image converter. Make sure the energy density of the beam is within the limits given by the specification. It is best to eliminate sources of stray light such as excessive room light. If the 90 degree beam splitter is being used, place it so the reflected beam is centered on the fluorescent plate. 3. Set the camera to pulsed mode as described in the instruction manual. Synchronize the laser pulses with the camera as described in the manual. 4. If the laser is a strong source of visible light as well as UV light (such as the flash lamp light coming out of the laser) you may have to place the camera-image converter assembly at an angle of ~5 degrees to the laser beam. In this way, the CCD will see the light scattered from the fluorescent plate but not the visible light from the laser. Document No 50374-001 Page 6 of 7 Rev A 05/2016

5. Add or remove ND filter attenuation as needed, but maintain the 12mm spacing distance when used on 4.5mm back focus cameras or the 4mm distance when used on CS back focus cameras. 6. Adjust the Focusing barrel containing the fluorescent plate for the sharpest image on the CCD. When best focus is found lock it with the locking nut. (Note that the position has been adjusted in the factory and you should ordinarily not have to change the original focus setting). Spectral range Minimum signal Saturation intensity Specifications 193 to 360nm ~1uJ/cm² with blank filter ~15mJ/cm² at 193nm, ~20mJ/cm² at 248nm with included filter 20x greater with optional beam splitter Resolution 35µm x 35µm Damage threshold Aperture 100W/cm² or 2J/cm² with beam splitter Maximum beam size is the same as for the particular camera used since the image size is not changed from the original beam size. Table 1 X1 UV Image Converter specifications (1) Above 310nm the glass begins to transmit UV light. Therefore you may see some of the original laser s light also as background interference. Document No 50374-001 Page 7 of 7 Rev A 05/2016