Metalclad Plus Technical

Similar documents
Metalclad Plus Technical

Metalclad Plus Technical

Grosvenor Plus Technical

Logic Plus Technical. Switchsocket Outlets TD1. Standards and approvals. Description. Technical specification

Switchsocket Outlets. 382 Logic Plus Technical. wiring devices white. Standards and approvals. Description

Chroma Plus 130 decorative High quality, lustrous finish with modern curved design Total safety

Slimline. Technical Hotline

to modern interiors. As trends in contemporary décor increasingly include the use of chrome

Logic Plus. Logic Plus wiring devices from MK Electric have been designed to perfectly complement modern

Logic Plus. wiring devices white.

Vimark. t: e: w: detaelectrical.co.uk

Elements Collection Technical

Alloy. technical hotline +44 (0) decorative wiring devices

LOGIC PLUSTM RANGE INTRODUCTION

Wiring Devices Technical

Logic Plus. wiring devices white

Slimline Plus. Catalogue No. R6. For reference only.

10AX SP 1g/2w switch, min. 25mm deep back box required, IEC , BS EN , Rated Voltage: 250V, screw-type terminals, studiowhite

Kalo Attraction in simplicity

Ergonomic Electrical Accessories

Ergonomic Electrical Accessories

Decorative Flat Plate Electrical Accessories in Various Plate Finishes Issue 5

RCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions

Sentry. The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its

Decorative Metal Wiring Accessories in Assorted Plate Finishes

Sentry. The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its

Weathersafe Vision. Installation & Operating Instructions

Metal Clad Wiring Accessories. A rugged scratch resistant metal, suitable for everyday use in commercial and industrial environments

BRITISH STANDARD WIRING ACCESSORIES NEW PRODUCTS Synergy. Sleek Design equipped mechanisms (p. 560 to 564)

Decorative Flat Plate Electrical Accessories in Various Plate Finishes

A premium range of bright white accessories

Ergonomic electrical accessories

XTRA Surface Metalclad Accessory Range

Simply Stylish Wiring Accessories

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

DIMENSIONS Screwless Wiring Devices

Trade Product Catalogue 2018/2019. Trade CELEBRATING YEARS OF. Product Catalogue 2018/

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Technical data Consumer units and enclosures dimensions and data 12.4

46MM 47MM FLUSH 35MM FLUSH 35MM FLUSH 866ZIC 10 1 GANG ONE ADJUSTABLE LUG 886ZIC 5 2 GANG ONE ADJUSTABLE LUG DIMENSIONS

46mm 47mm FLUSH. 35mm FLUSH. 35mm FLUSH 866ZIC 886ZIC. 1 gang: 60.3mm 2 gang: 120.6mm

Sentry. Flush mounting versions Flush mounting available for even neater installations.


The right solution for every home

Electrical Demand Specification (Reference SOP: )

Vimark Curve Vimark Evo

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

Niloé. Getting it just right

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

ECO 60 RANGE INTERNATIONAL DOMESTIC RANGE

Plexo IP 55/IP 66 Makes your day, rain or shine

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Surge Protection Products for the small office/home office and professional grade

CONTROL MICROSYSTEMS and 5402 Digital I/O Module. Hardware Manual

Stylish Electrical Essentials

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Operating instructions. Switching amplifier DN0210 DN / / 2015

Nexus Flatplate. Nexus Flatplate Wiring Accessories. Slimline screwless and screwed accessories available in a range of decorative metal finishes

ELECTRICAL ACCESSORIES - E SERIES

MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A

Consumer Units IP Rated & Metal Enclosures Devices - MCBs, RCBOs & RCDs. Control Devices & Accessories

BlueWave ~ Intelligent Energy Control. Installation and User Manual for BW2/C and BW3/C versions. Quick Guide

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

The EMITEX PRODUCT GUIDE 2018/19

Sentry Technical. Consumer Units and Enclosures TD255. Standards and approvals. Description. Features. Technical specification

InForm Superstructures

Surface-Mounting Product Ranges

訂 貨 熱 線 香 港 批 發 / 分 銷 澳 門 批 發 / 分 銷

Myrius TM mechanisms - white

Nexus Flatplate. Nexus Flatplate Wiring Accessories. Slimline screwless and screwed accessories available in a range of decorative metal finishes

Panasonic top level series with super panel and vigorous outlines bringing elegance to your everyday life. BS-TYPE

MMLG 01, 02, 03, 04 MMLB01

Plexo IP 55/IP 66. Makes your day, rain or shine PLEXO / WEATHERPROOF PRODUCT GUIDE. For reference only.

THIS PAGE LEFT BLANK

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

IT power distribution Power distribution units (PDU) Basic. Versions available:

Operating instructions. Speed monitor D / / 2014

Never Beaten by Seasons

4.5 Components for TV/SAT, telephone installations and Category DATATEL Series - TEL DATATEL Series - CAT5 DATATEL Series - TV/SAT

NEW 74 PS RANGE. Push-buttons, selectors and indicators ø 22mm

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable

Enhancing Business Performance

Home Networks. Principles, Applications and Desirability

Measurement Systems Datascan Installation and User Guide

Disconnect Switches. Safe Switching and Disconnecting

TABLE OF CONTENTS. IEC and IEC Pin and Sleeve Devices. IEC and IEC Mechanical Interlocks. Manual Disconnect Switches

FLEX Ex Spring Clamp Terminal Base

Myrius TM mechanisms - white

Protect Circuit Protection

COOKER AND APPLIANCE CONNECTION BOXES RUBBER SCHUKO PLUGS AND CONNECTORS FOR FIXED CONNECTIONS

MiCOM Agile P99x. Grid Solutions. Testing & Commissioning. Test Block, Multi-finger Test Plug and Single-finger Test Plug. Design Flexibility

ADVANCED SWITCHING TECHNOLOGY Miniature switch for a lighter and more comfortable touch. H A R M O N Y HIGHLY RELIABLE SAFETY FEATURES.

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Installation manual for for Schleifenbauer DPM3

4100 and 4100/R Controllers

Power Distribution Units with 13A Sockets

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

BOOSTMASTER ELECTRONIC BOOST TIMER

07. har-link INTERFACE CONNECTORS

Transcription:

TD83 TECHICAL HOTLIE +44 (0)68 56370 Socket Outlets All Metalclad Plus 3A socket outlets comply with BS 363: Part : 995. Electrical Voltage rating: 50V a.c. Current rating: 3A per socket outlet Terminal capacity: Live, neutral & earth 3 x.5mm 3 x 4mm x 6mm (stranded) (Dual earth terminals on list os. K850 ALM, K977 ALM, K477 ALM, K945 ALM Physical Ambient operating temperature: 5 C to +40 C (not to exceed an average of more than 5 C in any 4 hour period) IP rating: IPXD Max. installation altitude: 000 metres Box Knockouts: gang 6 x 0 dia in one side in each of the other 3 sides in base gang 8 x 0 dia 3 in top in bottom in each side A range of socket outlets designed for ease of installation and having all the advantageous design features of the Metalclad Plus range. The gang sockets with outboard rockers are of particular value for use by the infirm and partially sighted. on-standard, clean earth sockets are for use on installations where restricted access is required and will only accept MK L647 3A non-standard plug with T-shaped earth pin. The sockets have two independent earth terminals so that they can also be used for clean earth installations. K850 ALM, K977 ALM, K477 ALM, K945 ALM and K757 WHI are fitted with two earth terminals on a common busbar to provide a double earth facility for use when installations are to comply with Section 607 of BS 767, IEE Wiring Regulations. The products can be quickly installed as replacement for existing 3 amp sockets or in a new installation. Round pin sockets A range of round pin sockets is also available, switched and unswitched. in base Moulded on indicator flash on switches will not rub off totally safe Optional neon indicators in the switch rockers with 75 visibility in the horizontal and vertical planes Unique 3 pin operated safety shutter White terminal markings on grey rear mouldings for clearer identification Top access, angled terminals make wiring easier and quicker 3mm switch contact gap Double pole switching Choice of inboard or outboard positioned rockers Frontplates and backboxes manufactured from heavy gauge steel Additional electrical safety from neutral make first, break last feature Switch contacts with silver contacts on both surfaces for good continuity Only one size of screwdriver required for installation Dual earth terminals for high integrity earthing on list os. K850 ALM, K977 ALM, K477 ALM, K945 ALM, K757 WHI Backed out and captive terminal screws on-standard clean earth sockets available Socket inserts manufactured from tough thermoplastic see page 40 in the product selector.

TD84 www.mkelectric.co.uk Socket Outlets Installation Metalclad Plus socket outlets can be wall or bench mounted. Do not mount or use as a trailing socket or where they may be subject to excessive moisture or dampness. gang switchsocket view from rear Top-facing, angled, backed-out terminals make wiring easier and quicker. BOX TYPES Flush Flush (for extra Surface Metal wiring space) gang ZIC 6 ZIC as supplied gang ZIC 8 ZIC as supplied Dimensions (mm) gang 30 5 7 47 gang 46 30 5 0.6 7 47 46 30 5 0.6 7 47

Flag below Reset (R) button. Red : O Black: OFF ALWAYS TEST BEFORE USE Press Test (T) button, Red flag should disappear. If it does not, do not use. Press Reset (R) after testing. TD85 TECHICAL HOTLIE +44 (0)68 56370 Sentrysocket RCD Protected Switchsocket Outlets Compliance with EC Directives, All Sentrysockets comply with the following EC Directives and are CE marked: Low Voltage Directive (73/3/EEC) Electromagnetic Compatibility Directive (89/336/EEC) Sentrysocket RCD Sockets also comply with the requirements of the following standards: BS 788: 990 (993) BS 0 Part. Db (Damp Heat - cyclic) BS 0 Part. Ka (Salt mist) BS E 5008- Sentrysocket RCD Double Sockets comply with BS 788: 990 (993) and BS E 6543: 996 for EMC Electrical Rated Voltage: 40V a.c. Current rating: 3A resistive Rated tripping current: 30mA and 0mA versions Terminal capacity: 3 x 4mm Physical Sentrysocket provides a high level of protection against electrocution and gives further protection when used with appliances vulnerable to insulation damage, particularly when they are in damp environments or outdoors. Sentrysocket is not suitable for mounting in damp environments or outdoors. Sentrysocket, incorporating an RCD, is part of a complete range of fixed and portable wiring devices and circuit protection devices suitable for use in domestic, commercial and industrial applications. Active control circuit Sentrysocket products with an active control circuit incorporate a Re-set mechanism and are mains failure sensitive, i.e. they will function under all the normal conditions expected of an RCD, but will also trip in the event of a power cut or a sudden, dramatic reduction in mains voltage. This makes them ideal for use where it would be hazardous for equipment to suddenly energise after return of mains power, such as use with rotating machinery and heat developing apparatus. Passive control circuit Sentrysocket products with a passive control circuit incorporate a Stay-set mechanism and is mains failure proof, i.e. it will function under all the normal conditions expected of an RCD and will not trip in the event of a power cut. This makes it suitable for use with freezers or in inaccessible or unmanned locations. Ambient operating temperature: 5 C to +40 C IP rating: IPXD Max. installation altitude: 000 metres BOX TYPES Metalclad Plus Surface K897 ALM (Spare Box) Metalclad Plus products have the mounting box included with the product. They are suitable for surface mounting only. Available for Single or Double Sockets. Suitable for most residential, commercial and light industrial applications Active and passive control circuit applications Comply fully with current Wiring Regulations Double pole switching Dimensions (mm) Single socket 46 Flexible and versatile in use Ideal for use with equipment subject to wet weather or high humidity Part of a complete range of MK circuit protection devices They are a.c. and pulsating d.c. sensitive for residual current Double socket 46 6 5 T test before use press button - T sentrysocket rcd protected white off (tripped) red on on active control device trips with loss of mains 0mA tripping current sentrysocket rcd protected T R 0.6 0.6 9 see page 40 in the product selector.

TD www.mkelectric.co.uk Round Pin Socket Outlets Round pin socket outlets comply with BS 546: 950. Electrical Voltage rating: 50V a.c. Terminal capacities: amp sockets (K84): 7 x mm 4 x.5mm x.5mm x 4mm 5 amp sockets (K84): 3 x.5mm x 4mm x 6mm (stranded) 5 amp sockets (K843): 3 x.5mm 3 x 4mm x 6mm (stranded) Physical Ambient operating temperature: 5 C to +40 C (not to exceed an average of more than 5 C in any 4 hour period) IP rating: IPXD Max. installation altitude: 000 metres A range of socket outlets designed for ease of installation and having all the advantages and design features of the Metalclad Plus range. These products can be quickly installed as replacements for existing socket outlets or in new installations. Top access terminals make wiring easier and quicker Integral O indicator on switches will not rub off totally safe 3mm switch contact gap Double pole switching Terminal screws backed out Additional electrical safety from neutral make first, break last feature on switched sockets Switch contacts with silver contact points on both surfaces for good continuity 5A and 5A sockets contain a unique 3 pin operated safety shutter Printed terminal markings on grey rear mouldings for clearer identification A socket shuttered Installation Dimensions (mm) Metalclad Plus socket outlets can be wall or bench mounted do not mount or use as a trailing socket or where they may be subjected to excessive moisture or dampness. 9 5 Cable management Metalclad Plus socket outlets can be mounted in a variety of MK trunking systems. Depth Amp sockets: mm 5 Amp sockets: mm 5 Amp sockets: 3mm 47 see page 4 in the product selector.

TD87 TECHICAL HOTLIE +44 (0)68 56370 5A American Socket Outlet Complies with SSA: 444:985 5A American Electrical Voltage rating: 7V a.c. Current rating: 5A Terminal capacity: Live, neutral & earth 3 x.5mm x 4mm x 6mm (stranded) Dimensions (mm) 46 30 5 Physical Ambient operating temperature: 5 C to +40 C (not to exceed an average of more than 5 C in any 4 hour period) IP rating: IPXD 0.6 5 47 Max. installation altitude: 000 metres see page 4 in the product selector.

TD88 www.mkelectric.co.uk Connection Units and 0A DP Switches Connection units comply with BS 363: Part 4: 995. 0A DP switches comply with BS 3676: Part : 989. Fuses are to BS 36. Electrical Voltage rating: 50V a.c. Current rating: Connection units 3 amp DP switches 0 amp Terminal capacity: Supply terminal: x 6mm stranded x 4mm 3 x.5mm Load terminals: Flex outlet/cord grip capacities: Connection units: x 6mm stranded x 4mm 3 x.5mm min: core, 0.5mm max: 3 core,.5mm 0 amp DP switches: min: 3 core,.5mm max: 3 core,.5mm Physical Ambient operating temperature: 5 C to +40 C (not to exceed an average of more than 5 C in any 4 hour period) IP rating: With flex outlet: IPXD Without flex outlet: IP4X Max. installation altitude: 000 metres A range of 3A fused connection units and 0A DP switches designed for the connection of refrigerators, water heaters, central heating boilers and other fixed appliances. The ranges are designed for ease of installation and have the advantageous design features of the Metalclad Plus range. eon indicators eon indicators can be included in the rockers of the switched connection units. In the case of unswitched units, they are located centrally and uppermost on the face plate. eon indicators are integrally wired into the product and do not require separate connection when installing. The design gives 75 visibility in the horizontal and vertical planes. Fuse carriers These are captive and are opened by a fast acting, screwdriver operated worm drive for ease of replacement. A tamper-proof version is also available. Fuse carriers can be locked open using a padlock, List o. K000. Flex outlets The products are equipped with very strong, push-fit nylon cord grips making installation safe, quick and easy. see page 4 in the product selector.

TD89 TECHICAL HOTLIE +44 (0)68 56370 Connection Units and 0A DP Switches Optional indicators in the switch rockers with 75 visibility in the horizontal and vertical planes Worm-drive operated fuse carriers for additional security (tamper-proof version available) Fuse carrier lockable in open position All supply and load cables can be cut and stripped to the same length Integrally wired indicators save installation time Push-fit cord grips, for safer, quicker installation Angled, top mounted terminal screws simplify wiring Moulded on indicator flash on switches cannot rub off totally safe Captive fuse carrier Additional electrical safety from neutral make first, break last feature Secure cable and flexible cord connection All terminal and fixing screws operated by one-size (4mm) screwdriver Backed out and captive terminal screws Front outlet cord grip Box types Supplied with a box having x 0 mm knockouts in one side, as well as x 0 mm knockouts in each of the other three sides and the bottom of the box. Spare boxes are available without side knockouts (K89 ALM). All boxes have a knockout in the base. Lockable fuse carrier Installation Dimensions (mm) 49 Metalclad Plus connection units and 0A cable outlets and switches can be wall or bench mounted. Do not use on a trailing lead. fuse Wiring Products must be installed in accordance with current IEE Regulations. dia 9 Box types Supplied with a box having x 0 mm knockouts in one side, as well as x 0 mm knockouts in each of the other three sides and the bottom of the box. Spare boxes are available without side knockouts (K89 ALM). All boxes have a knockout in the base.

TD90 www.mkelectric.co.uk Plateswitches All Metalclad Plus plateswitches comply with BS E 60669-: 000 Electrical Voltage rating: 50V a.c. 50Hz Current rating: 0 amps no derating when used on fluorescent or inductive loads Terminal capacity: All products 4 x mm 4 x.5mm 3 x.5mm x 4mm x 6mm Contact gap: 3mm switch contact gap Physical Operating temperature: 5 C to +40 C) IP rating: IP4X A comprehensive range of tough, impact resistant, surface mounted plateswitches. They have been designed to suit a wide variety of applications in factories, workshops, plant rooms, warehouses, schools and hospitals. The frontplate has smooth chamfered edges engineered to fit flush with the backbox. Backboxes with or without side knockouts are available and all have a central knockout in the base. Wide rocker switches are also available. Max. installation altitude: 000 metres Operational testing (all plate switches): tested to 00,000 operations for mechanical life tested to 30,000 operations at 0 amp rating Two way switches can be wired as one or two way All products clearly printed with BS os., ratings, etc Matching Grid switches available in 0 or 0A ratings 3mm switch contact gap Positive switch action Top access, backed out and captive terminal screws Metalclad Plus is supplied with white inserts only An earth terminal is provided attached to rear of product and in base of mounting box BOX TYPES Flush Surface All, and 3 gang switches 3995 ZIC K60 WHI All these products are designed primarily for surface mounting and are supplied complete with mounting box. If flush mounting is required then recommended box is 3995 ZIC 6mm deep. see page 43 in the product selector.

TD9 TECHICAL HOTLIE +44 (0)68 56370 Plateswitches Dimensions (mm) gang gang 3 gang 9 Wiring Diagrams One-way switching Common L Lamp/s Two-way switching wire control Wide rocker Common Common 5 9 L Two-way switches Lamp/s Dotted lines show alternative switch positions Two-way switching plus intermediate switching wire control 47 Common Common L Two-way switch Intermediate switch Two-way switch Lamp/s Dotted lines show alternative switch positions Two-way switching 3 wire control Common Common L Lamp/s SW.L Two-way switches Dotted lines show alternative switch positions Two-way switching plus intermediate switching 3 wire control Common Common L Lamp/s SW.L Two-way switch Dotted lines show alternative switch positions Intermediate switch Two-way switch.b. Terminal positions may alter. The above diagrams are to show wiring layout.

TD9 www.mkelectric.co.uk High Current Switches All DP switches in the range conform to BS 3676: Part : 989 Electrical Voltage rating: 50V a.c. Current: 3/45A resistive Switch: 3mm contact gap Double pole operation Terminal capacity, 45A Switches 4 x 4mm 3 x 6mm x 6mm Terminal capacity, 3A Switch: 3 x.5mm x 4mm x 6mm Physical A range of switches and cooker control units harmonising with the Metalclad Plus style, suitable for the switching of all domestic, commercial and industrial appliances where higher current ratings are required, i.e. cookers, heaters, commercial refrigeration units etc. Metal units are particularly suitable for refurbishment projects. Ambient operating temperature: 5 C to +40 C (not to exceed an average of more than 5 C in any 4 hour period) IP rating: IP4X Positive switch action Positive double pole switching Toggle action switches Very robust paint finish Metal frontplates Replaceable neon indicators Max. installation altitude: 000 metres ote: These switches are not recommended for switching large banks of PCs Box types 3A switch supplied with a box having x 0mm knockouts in one side, as well as x 0mm knockout in each of the other three sides and the bottom of the box. 45A switch supplied with a box having 3 x 0mm knockouts in one of the long sides and x 0mm knockouts in the other. Both short sides and the bottom of the box have x 0mm knockout. Spare boxes are available for both size of product with no knockouts in any of the sides (K89 ALM for 3A, K830 ALM for 45A). A knockout is retained in the bottom of each box. BOX DEPTHS BOX REFERECES List o. Max. cable size Flush Surface Flush 3A 45A Switches 3A 0mm 46mm 40mm Box depth 46mm 877 ZIC 45A 0mm 47mm 40mm 47mm 878 ZIC Dimensions (mm) K540 ALM 49 off on K530 ALM 87 49 off 47 on 60 see page 43 in the product selector.

TD93 TECHICAL HOTLIE +44 (0)68 56370 Three Pole Fan Isolators Comply with BS E 60947: 99 Electrical Voltage rating: 50V a.c. 50Hz Current rating: 0 amps Terminal capacity: 4 x mm 4 x.5mm 3 x.5mm x 4mm x 6mm Contact gap: 3mm switch contact gap Classifications Method of operation: Stored energy operation Suitability for isolation: Suitable for isolation Ratings Utilisation category AC3B Rated operational voltage (Ue) 50V Conventional free air thermal current (Ith) 0A Rated frequency 50Hz Rated making capacity 00A rms Rated breaking capacity 80A rms Rated conditional short-circuit current 6000A rms (with supply side protective device GEC IT 6 BS88: part : 988 6A 550VAC utilisation category gg 80KA breaking capacity fuse links.) Physical The MK Three Pole Fan Isolator provides a safe and simple method of isolating mechanical fan units and is particularly useful in bathrooms, toilets, storerooms and basements where there is little or no natural light. For example, timer controlled fans are often linked into the lighting circuit for energy saving and convenience. In such an installation there is often a need for the lighting circuit to remain live to provide light whilst the fan unit is externally isolated so that routine maintenance and repairs can be carried out in complete safety. The K857 fan isolator can be used as a double pole or triple pole isolator. In addition it includes a clear on/off indicator and the frontplate features a fan isolator symbol for easy circuit identification. Dimensions (mm) on isolator off 9 47 Operating temperature: 5 C to +40 C) IP rating: IP4X Max. installation altitude: 000 metres Switchlock list no. K4858 is available to allow the isolator to be locked in the disconnected position to facilitate fan maintenance see page 43 in the product selector.

TD94 www.mkelectric.co.uk Three Pole Fan Isolators Wiring Diagrams Two pole switching for fan units without timers L Supply TOP L L L L Rear view of Fan Isolator To Fan Unit without Timer (see Fan Unit Intructions) L (switched) L Supply TOP L L L L Rear view of Fan Isolator To Fan Unit without Timer (see Fan Unit Intructions) L (switched) Three pole switching for fan units incorporating timers L Supply TOP L L L L Rear view of Fan Isolator To Fan Unit with Timer (see Fan Unit Intructions) L (unswitched) L (switched) L Supply TOP L L L L Rear view of Fan Isolator To Fan Unit with Timer (see Fan Unit Intructions) L (unswitched) L (switched)

TD95 TECHICAL HOTLIE +44 (0)68 56370 Euro and LJU6C Data Frontplates BS 5733 Dimensions Height: mm Width: mm (G) 46mm (G) Depth: 9mm Aperture Dimensions Frontplates used for mounting snapfit data modules. Euro Frontplates Height: Width: 50mm 50mm (G) Dimensions (mm) LJU6C Frontplates 00mm (G) Euro Frontplates Height: Width: 37mm mm gang K8 ALM 9 G and G frontplates Metalclad Plus style Accept industry standard (Euro) and LJU6C snapfit modules G Euro frontplate accepts Euro modules, (50 x 50mm aperture) G Euro frontplate accepts 4 Euro modules, (00 x 50mm aperture) G LJU6C frontplate accepts two LJU6C modules (7 x 37mm aperture) gang K84 ALM 46 9 module (.5 x 50mm) blank available for Euro frontplates Interchangeable modules clip into frontplate LJU6C Frontplates K7 ALM 0.6 9 see pages 44 45 in the product selector.

TD96 www.mkelectric.co.uk RJ45/ISD Data Outlets BS E 5073. IEC 80. TIA/EIA 568A. Suitable for use in all LJU6C, Euro and MK Modular frontplates, available in the Metalclad Plus range, Cat5/5e and ISD modules suitable for use in structured cabling distribution systems. ISD modules incorporate a line terminating resistor. Installation Maximum cable length 90m. Cable bend radii, 40mm during installation, 0mm after installation. Maximum pull force 8.7kg. Do not over tighten cable ties. Do not unwind the twists in the wire pairs by more than 3mm max. BOX TYPES Depth UTP STP 5mm 3mm DIMESIOS Euro LJU6C 5 x 50mm x 37mm MK Modular: Decorative 5 x 50mm (only fit into MK decorative modular frontplates and require grid plus mounting frames) Installation details and wiring diagram illustrations TIA WIRIG SCHEME COLOUR CODES: Euro and LJU6C modules are to be wired as follows Pin o. 568A 568B WHITE / green WHITE / orange GREE / white ORAGE / white 3 WHITE / orange WHITE/ green 4 BLUE / white BLUE / white 5 WHITE / blue WHITE / blue P3 P P 568A P4 P P3 P 568B P4 4 6 8 7 5 3 6 ORAGE / white GREE / white 7 WHITE / brown WHITE / brown 8 BROW / white BROW / white Pair BLUE/white & WHITE/blue Pair ORAGE/white & WHITE/orange Pair 3 GREE/white & WHITE/green Pair 4 BROW/white & WHITE/brown see pages 44 45 in the product selector.

TD97 TECHICAL HOTLIE +44 (0)68 56370 Telephone, RJ/, BC Data and Blank Modules Telephone sockets K580 and K58 comply with the following: BS 63:., OFTEL Approval S/G/3/L/00005. Data sockets K580, BS 5733:995 (where applicable). K5887 complies with FCC68. Electrical Cable types: Telephone: CW3, CW93, CW308, CW36 o. of cables per termination: Telephone: RJ/: BC 50. impedance cable RG58, RG4, URM43 Belden 9907 Frequency range: BC connector: 0 to 4GHz Impedance: BC Connector: 50. nominal Termination type: Telephone module IDC BC module Crimped connection Physical Temperature range: Ambient air 0 C to +60 C IP rating: IPXD K580, K58, K580 and K5787. IP4X K80, K88, K and K70 Max. installation altitude: 000 metres DIMESIOS (mm) List o. Dimensions K580 / K58 / K580/ K88 / K5887 5 x 50 K80 50 x 50 K.5 x 50 K5787/K70 x 37 Meet all relevant BS, OFTEL and cabling standards Interchangeable modules clip into frontplates Front fixing facilitates easy exchange of modules Part of a complete range of products for telephone and data processing requirements Telephone sockets 00% tested before delivery Quick, simple and reliable IDC connectors A range of telephone, data and blank modules to fit Euro and LJ6UC front plates. BC Euro modules with a 50Ohm crimp connector suitable for use with RG58, URM43, URM76 and Beldon 9907 type co-axial cables are also available. Installation (Telephone socket modules) Product performance, systems compatibility Master Sockets: For use as the first socket outlet on a direct exchange. They contain the required surge protector (for line protection against electrical surges) and ringing capacitor. Secondary Sockets: for use as extension sockets when connected on the same line as a Master Socket. Installation tools required IDC Connectors (telephone & RJ45 outlets) MK insertion tool List o. 400 or 630. Wire pull-out force: 0.5 ewtons when installed correctly. Wiring regulation restrictions Domestic Installations: The total RE (Ring Equivalent umber) value of all telephone equipment connected on a line must not exceed 4. BOX TYPES K580 / K58 K580 / K5887 / K5787 6mm 5mm Can be specified for all applications Fit in plaster depth boxes Data sockets Latest specification for high performance systems Made to stringent quality assurance procedures Wide range of data connectors available For information on TV Satellite and FM Modules see pages TD98 TD99 BT Wiring Scheme GREE / white BLUE / white 3 ORAGE / white 4 WHITE / orange 5 WHITE / blue 6 WHITE / green ote: Main wire colour is shown in capitals IDC terminals 6 5 4 Cable tie First Socket Outlet Master 3 Cable tie hole Extension Outlet Secondary 3 4 5 6 3 4 5 6 RJ/ Wiring Scheme PI STRIPPED COLOUR SOLID COLOUR O. WIRE WIRE WHITE / green White WHITE / orange Black 3 BLUE / white Red 4 WHITE / blue Green 5 ORAGE / white Yellow 6 GREE / white Blue ote: Main wire colour is shown in capitals 3 5 6 4 see pages 44 45 in the product selector.

TD98 www.mkelectric.co.uk Digital TV Outlets All MK Digital TV Outlets comply with BS 5733 and BS E 50083 where applicable. Also IEC 69-, BS E 6069-4 and BS 63 part Modular products are Euro compatible. Frequency Specification TV outlet Single Modules: DC - 950MHz Diplexer Modules:DC - 68.5MHz, 74 - MHz Triplexer Modules: 5-68.5MHz, 74 - MHz FM outlet Single Modules: DC - 950MHz Diplexer Modules: 87.5-08MHz Triplexer Modules: 87.5-08MHz SAT outlet Single Modules: DC -.75GHz Diplexer Modules: n/a Triplexer Modules: DC - 00kHz: 950-400MHz Diplexer modules are for connecting to a single co-axial aerial down lead carrying combined TV and FM signals. The filtering in the diplexer splits out the appropriate signal and feeds it to the relevant output connection. A DC control path is provided in the TV signal path through the diplexer. Triplexer modules are for connecting to a single co-axial aerial down lead carrying combined TV, FM and SAT signals. The filtering in the triplexer splits out the appropriate signal and feeds it to the relevant output connection. A DC control path is provided in the SAT signal path through the triplexer. Dimensions (mm) Euro module (monobloc) 50 38 Installation When installing the TV Co-axial cable ensure that all cable bends are smooth so that the inner insulation is not crushed or squashed. Otherwise the TV signal quality may be affected. ot suitable for loop-in loop-out installations on Isolated Fully screened Earth terminal provided on TV modules Cable management Digital TV outlets can be mounted in a variety of MK trunking systems. 50 Euro module (monobloc) 5 38 use CT00 cable (or equivalent.) TV Co-axial cable stripping details 6.5 6.5 Screening braid to remain in place over the inner insulation Earth terminal 50 Cable clamping plate ote: Minimum box depth: 47mm Co-axial cable Foil EMC screening gasket Clamping plate fixing screws Earth terminal View with cable clamp removed see page 44 in the product selector. Co-axial cable Clamping fixing screws Cable clamp

TD99 TECHICAL HOTLIE +44 (0)68 56370 Digital TV Outlets Installation (Digital TV sockets) Product Performance, System Compatibility Isolated Outlets are intended for use where safety isolation (rated at 000V ac) is required to provide protection against faults occurring within any mains powered product used on different parts of the distribution system. They are not suitable for use in systems where DC signals are passed through the socket, (e.g. where masthead/headend equipment is controlled by receiver/decoder equipment). Diplexer Outlets are used in distribution systems where both TV and FM band signals are combined on a single aerial downlead. The filtering in the diplexer separates the appropriate signals and feeds them through to the relevant output connection port. Triplexer Outlets are used in distribution systems where TV, FM and Satellite band signals are combined on a single aerial downlead. The filtering in the triplexer separates the appropriate signals and feeds them through to the relevant output connection port. Cable Routing and Use of Cable Clamp Sharp bends in the cable must be avoided during installation. The single TV/FM socket is fitted with a cable clamp that can be fixed on either side of the termination position to facilitate this. When tightening the screening braid clamps ensure that the cable is firmly gripped and that the inner insulation is not squashed flat beyond a slight oval shape. Safety Information TV outlets or modules must not be installed in the same enclosure as equipment rated in excess of 50V, (e.g. mains rated 3A sockets or switches). Distribution system for Digital TV, FM and Satellite signals using a single aerial downlead. TV VID TV 3 FM 4 4 TV DIST 4 TV TV VID SKY/DIG HI-FI Method of installation of TV and FM aerial connection by using MK co-axial socket outlet and only one downlead. Conventional distribution system for TV and FM signals using a single aerial downlead. The signals form the TV and FM aerials and the satellite dish are combined together using two products. The first combines the TV and FM signals and the second adds the Sky signal to the TV/FM signal and provides a DC control path to power the LB unit on the satellite dish. (These products are not supplied by MK). TV SAT The single aerial down lead feeds into the triplexer of a K3563 outlet. (Black lines in wiring diagram). 3 4 The separated satellite signal is then fed to the decoder. The decoded satellite signal is then fed into the VCR along with the TV signal from the Triplexer. The output signal from the VCR then feeds into the TV and also back to the single outlet on the K3563 and onto the distribution amplifier (black lines in wiring diagram). The single cable back-feed from the K3563 then feeds back to the input of a multi way distribution amplifier, (typically located in the loft or garage) (red lines in wiring diagram). Each individual output from the distribution amplifier is then fed to the individual rooms in the house to a standard TV (single or diplexer) outlet to which the TV/VCR and/or Hi-Fi can be connected (blue lines in wiring diagram).

TD00 www.mkelectric.co.uk MK Modular Datacoms Metalclad Telephone and Data sockets comply with the following: Telephone sockets K45 and K457 BS 63:., OFTEL Approval S/G/3/L/00005 Data sockets K90 to K45, K458 BS 5733: 995 (where applicable) Data sockets K455 Cat 5e performance to EIA/TIA TSB568, BS E 5073, IEC80 Electrical Cable types: Telephone CW3, CW93, CW308, CW36 RJ45: 0 to 6 AWG, 00 ohm Cat 5e UPT cable o. of cables per termination (Telephone & RJ45): Telephone: RJ45: BC 50Ω impedance cable RG58, RG4, URM43 Belden 9907 Frequency range: BC connector: 0 to 4GHz Impedance: BC Connector: 50Ω nominal Termination type: RJ45& telephone module IDC BC module Crimped connection Physical Temperature range: Ambient air 0 C to +60 C IP rating: IPXD Max. installation altitude: 000 metres A unique modular system in the distinctive Metalclad Plus style comprising a range of socket modules for Data and Telephone use, with 4 to matching frontplates capable of accepting combinations of interchangeable modules. Modules clip into mounting frames which, when attached to frontplates, provide a high degree of versatility, making the system ideal for use in all commercial and industrial applications. Meet all relevant BS, OFTEL and cabling standards Part of a range of products for telephone and data processing requirements Interchangeable modules clip into grid frame which attaches to frontplate Dimensions Data and TV modules (mm) (Minimum box depth 6mm) Telephone sockets and frontplates Quick, simple and reliable IDC connectors Can be specified for all applications Data sockets and frontplates Cat 5e specification performance Made to stringent quality assurance procedures 5 3 5.5 5.5 58 58 58 4 K45 WHI K455 / K45 / K457 / K458 WHI K90 WHI see pages 45 46 in the product selector.

TD0 TECHICAL HOTLIE +44 (0)68 56370 MK Modular Datacoms Dimensions Modular frontplates (mm) 46 Installation (Data sockets) RJ45 modules In order to maintain Category 5e performance, install cabling in accordance EIA/TIA or ISO General Cabling Standards. Installation (Telephone socket modules) module K9 ALM 3 module K93 ALM 0.6 46 Product performance, systems compatibility Master Sockets: For use as the first socket outlet on a direct exchange. They contain the required surge protector (for line protection against electrical surges) and ringing capacitor. Secondary Sockets: for use as extension sockets when connected on the same line as a Master Socket. Installation tools required IDC Connectors (telephone & RJ45 outlets) MK insertion tool List o. 400 or 630. Wire pull-out force: 0.5 ewtons when installed correctly. module K9 ALM RJ Wiring Scheme PI STRIPPED COLOUR SOLID COLOUR O. WIRE WIRE WHITE / green White WHITE / orange Black 3 BLUE / white Red 4 WHITE / blue Green 5 ORAGE / white Yellow 6 GREE / white Blue ote: Main wire colour is shown in capitals 4 module K94 ALM 0.6 6 Rear View of Terminal Connection Block Wiring regulation restrictions Domestic Installations: The total RE (Ring Equivalent umber) value of all telephone equipment connected on a line must not exceed 4. Industrial and commercial installations: MK telephone sockets are suitable in all situations after the PBX/PABX has been installed by a recognised installer. For key systems and other special systems, the manufacturer s instructions should be referred to. Safety information one of the above products should be installed into the same fixing or mounting boxes as mains ratedequipment or cable. ote: For BT and RJ45 wiring scheme diagrams see pages TD97 and TD96 respectively. BOTTOM Cable management Metalclad Plus Modular Data and Telephone Sockets can be mounted in a variety of MK trunking systems. See main catalogue for further details.

TD0 www.mkelectric.co.uk Grid Plus Front Plates BS 5733: 995 Grid Plus is a comprehensive modular switching and monitoring system ideal for a variety of applications within the commercial, public and domestic sectors. Dimensions 46 46 module K349 ALM module K349 ALM 3 module K3493 ALM 4 module K3494 ALM 46 46 46 46 46 06 6 module K3496 ALM 46 8 module K3498 ALM 06 9 module K3499 ALM 06 06 06 67 module K350 ALM 8 module K3508 ALM see page 46 in the product selector. 4 module K354 ALM