Bosch solution 6000 cheat sheets

Similar documents
i Note Intrusion Control Panel Solution 64 Release Notes for Version Release Notes March, 2007

CP150B Vandal & Weather Resistant Keypad Security Systems

Solution 144 Security Systems

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

Solution 16 plus. User Guide Security System

DAS 250L CONTROL COMMUNICATOR INSTALLATION MANUAL

Control Panel ICP-SOL2-P/ICP-SOL3-P. en Quick Reference Guide

DAYLIGHT SAVINGS TIME START/END MONTH [ 0 ]0 = Disabled; 1 = Enabled. 1 Start End

Safecom Solution-16 Quick Reference Guide ISSUE 1.10

AMAX panel. AMAX panel 2100 AMAX panel 3000 AMAX panel 3000 BE AMAX panel en Operation Manual

Property of Monitronics Inc

Telephone and Reporting Setup in ElkRP

Created by: Alarm System Store Quick Start Guide. for Interlogix NetworX NX4, NX6 & NX8

Property of Monitronics Inc

2 IDS LCD Keypad User Manual C Issued March 2009

Ademco Vista-20SE/First Alert FA-162C Program Sheet

Control Panel Solution 2000 / 3000

Modules Programming Guide. paradox.com

Property of Monitronics Inc

Colour Graphic Terminal User Manual. Rev 3.1

Agility Installation Quick Start Guide 1

High Security and Access System EVO48 V2.1 EVO192 V2.1

Property of Monitronics Inc

Important Notice. Customer Information. 2 WisDom User Manual

ACTsmart2 Product Range Operating and Installation Instructions

Contents. 4. Disarming the Control Panel How to Disarm with a User Code How to Disarm using a Key-Switch or Remote...

Installation Quick Start Guide

Modules Programming Guide

Ademco/Protection One 250P1-1 Programming Form

*00 INSTALLER CODE Enter 4 digits, 0-9 [4140] *28 POWER UP IN PREVIOUS STATE [1=yes] 0=no; "1" for UL.

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO D ISSUED NOVEMBER 2002 VERSION 2.

MG/SP Series (V4.9/V5.1) What s New

First Alert FA160C/162C Installer Notes M. Leuck

Avantis AXI WEB SERVER MODULE USER MANUAL

PCX 46 App User Manual

VISTA-128BP/VISTA-250BP Programming Form

VISTA-20SEa. 3-Partition Security System. Programming Form. V20SEaPRV1 9/98

INT-KSG Keypad Quick user s guide

4140XMPT2 PROGRAMMING FORM

MCM Electronics MCM Electronics MCM Electronics. The Icon Series. Installation and Programming Information. Icon 8 Version 5.0

SUPERPLEX. User s Manual. High performance, simplified wireless home security controller. Products that work. Software Release: V2.

Installer Notes 4110DL/XM, Vista 10, Vista-20, Via-30PSE

INPUTS: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup)

SUPERPLEX 2. User s Manual. High performance, simplified wireless home security controller. Products that work. Software Release: V2.

1HWZRU;1;( Table of Contents. General Description...2. Ordering Information...2. Feature Definitions...3. Programming the LED Keypads...

VISTA-20BAY PROGRAMMING GUIDE SECURITY SYSTEM SINCE 1946

2015/09/24. M-Touch

INT-KSG Keypad Quick user s guide

to that area and whether or not the Cardax FT GBUS URI (Standard or person holds these competencies. Wiegand variant)

4 balanced inputs 1 relay output

TM50 Touch Intuitive Touchscreen

EVOHD. Programming Guide. Version

RANGER 9000E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Series. NX-8-EUR Control Panel. Installation manual

SILENCING AN ALARM. When the alarm bell or siren is sounding, enter your user code or present your keyfob to your keypad.

Operation manual For NG BIOSINGLE Version 1.1

PROGRAMMING HELP GUIDE

DSC POWERSERIES NEO INTEGRATION. This application note will explain how to setup the DSC PowerSeries NEO integration on a KT-400 or a KT-1-M

DAS LCD ALPHA NUMERIC CODEPAD

Digiplex EVO High Security and Access System What s New EVO192 V2.7

CUSTOMER INFORMATION

VISTA-50P VISTA-50PUL

ACTpro Single Door IP Controller. Operating & Installation Instructions

EC-11 Ethernet Converter

3 6HFXULW\6\VWHP 3URJUDPPLQJ)RUP K4332 9/99 BYPASS NOT READY ARMED READY 4 MAX 5 TEST 6 BYPASS 7INSTANT 8 CODE 9CHIME READY ARMED

RFID/Digital Access Control Keypad

Table of Contents. Phone number configuration...15 Alarm Phone numbers, 1, 2 & Divert phone numbers 1, 2 &

Integriti User Manual. Elite / EliteX LCD Terminal Keypads

Installation & User Manual

VANDERBILT PRODUCT CATALOGUE

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

UCM/KNX2 - Comfort to KNX Interface

Commercial Fire and Burglary Partitioned Security System with Scheduling. Programming Guide. K0376PRV5 2/11 Rev. A

SigNET 200/300 User Guide

PW6000 Modular Access Control System PW6000 Intelligent Controllers and Modules

THE OPERATOR INTRODUCTION 2 ACCESSING YOUR SYSTEM 2 FUNCTIONS OF THE "OPERATOR" 3 PROGRAMMING/CHANGING ACCESS CODES 12 ACTIVATING EMERGENCY ALARMS 13

IDS1200 INSTALLER MANUAL. Summary of Operation 2 IDS1200 INSTALLER MANUAL - NO B ISSUED AUGUST 2002 VER 1.18

SUPERPLEX. Superplex s User s Manual Draft. Thank you for purchasing this device CONTENTS

Dialler HA2000 RTC. Installation & Operating Manual

ACTpro 1500 Single Door IP Controller

ACCESS CONTROL SYSTEM

Installation Guidelines for KODAK SA101 Alarm System

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

PRO3200 Professional Modular Access Control Hardware

NX1700EIB02 (Supercedes NX1700EIA02) NetworX Series. NX-1700E Proximity Card Reader Installation and Startup

KeyWatcher Illuminated Specifications

DSC PowerSeries Neo Integration

FSK TX CELLULAR PLUS. Installation and Programming Guide. Tel:

ATS1190 Smart Card Reader Programming Manual

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

Installation Instructions

Waterproof Exit Button x40x30/44mm - IP68, 304 Stainless Steel - Voltage: DC12V, DC9-24V (-W402N)

Controller Cardax FT Controller The CardaxFT Controller 5000 is the intelligent field controller in the CardaxFT security system.

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

PRO2200 Professional Modular Access Control Hardware

CA111x-series Arming Station

Access control panel U-Prox IC E (Elevator control)

USER MANUAL. Alarm Control Panels. SATEL sp. z o.o. ul. Budowlanych Gdańsk POLAND tel Firmware version 1.

Simple & Easy Installation

IDS X-Series User Manual E Issued June 2013

Transcription:

Adding a token to a user Select add token and user if prompted by keypad select reader Menu 120 Select door/s that the user will have access to (if applicable) Menu 145 Select areas that the user will belong to Menu 141 Adding a keyfob Enable the receiver - Select option 4 bosch serial receiver Menu 350 Select add keyfob and select user, then enter 9 digit code Menu 130 Select areas that the user will belong to Menu 141 Adding a Fingerprint Select add a fingerprint Menu 180 Select door/s that the user will access to(if applicable) Menu 145 Select area's that the user will belong to Menu 141 Setting up a door for access only Assign user to a door/s Menu 145 Untick reader area control Menu 614 Assign reader/keypad to a door assignment Menu 617 Set output to required function (e.g. 60 Door) Menu 411 Select event assignment (door Name) Menu 412 Select output polarity (e.g. Open one shot low = 4) Menu 413 Set time parameter for the output (e.g. 10sec) Menu 414 Set any options required for the output Menu 415

Setting up a door & User with arm, disarm & badging required Assign user to a door/s Menu 145 Select reader & enable all on & disarming allowed. Menu 612 Select reader and enable reader badging (& egress if required) Menu 614 Select reader and enable reader area control Menu 614 Assign reader/keypad to a door assignment Menu 617 Set output to event type 60 Door Menu 411 Select event assignment (door Name) Menu 412 Select output polarity (e.g. Open one shot low = 4) Menu 413 Set time parameter for the output (e.g. 10sec) Menu 414 Set any options required for the output Menu 415 Setting up a door with D.O.T.L triggering an output Select options for reader/keypad (e.g.; arm/disarm/part) Menu 612 If required Select reader badging & reader area control Menu 614 Assign reader/keypad to a door assignment Menu 617 Set output to required function (e.g. 60 Door) Menu 411 Select event assignment (door Name) Menu 412 Select output polarity (e.g. Open one shot low = 4) Menu 413 Set time parameter for the output (e.g. 10sec) Menu 414 Set any options required for the output Menu 415 Select a zone for D.O.T.L function in pulse count ( 13 ) Menu 313 Set D.O.T.L time frame in pulse count time Menu 314 Select the door the the D.O.T.L will work with Menu 315 Set report route in Menu 316 Set alarm condition if required for door forced Menu 423 Select output type 61 D.O.T.L alarm Menu 411 Select the door the D.O.T.L is operating on Menu 412 Set output polarity for the output. Menu 413 Set time parameter for the output Menu 414 Select output options for the output Menu 415

Access control with time zones Assign user to a door/s Menu 145 Assign user to a time zone (e.g. time zone 2) Menu 144 Assign reader/keypad to a door assignment Menu 617 Select options for reader/keypad (e.g.; arm/disarm/part) Menu 612 If required Select reader badging Menu 614 Set output to required function (e.g. 60 Door) Menu 411 Select event assignment (door Name) Menu 412 Select output polarity (e.g. Open one shot low = 4) Menu 413 Set time parameter for the output (e.g. 10sec) Menu 414 Set any options required for the output Menu 415 Select door options in Menu 423 Select name for time zone Menu 750 Set time frame that the user will have access (e.g. 9am-5pm) Menu 751 Set the days that the time zone will be active Menu 752 Access control with door auto open/close Assign user to a door/s Menu 145 Assign reader/keypad to a door assignment Menu 617 Select options for reader/keypad (e.g. arm/disarm/part) Menu 612 If required Select reader badging Menu 614 Set output to required function (e.g. 60 Door) Menu 411 Select event assignment (door Name) Menu 412 Select output polarity (e.g. Open one shot low = 4) Menu 413 Set time parameter for the output (e.g. 10sec) Menu 414 Set any options required for the output Menu 415 Select unlock time zone for door (e.g. time zone 2) Menu 422 Select door options in Menu 423 Select name for time zone 2 Menu 750 Set the unlock time period for the door Menu 751 Set the days that the time zone will be active Menu 752

Using outputs with time zones Select desired output & select event type 58 time zone Menu 411 Select output event assignment (e.g. time zone 2) Menu 412 Select output polarity Menu 413 Select output time parameter Menu 414 Select time zone and set time frame for that time zone Menu 751 Select the days of the week that the time zone will operate Menu 752 Operating a door with a single digit code Set user pin length to 0 ( 0 = variable ) Menu 150 Set user 10 pin code to 5 Menu 112 Set user 10 Area assignment to no area Menu 141 Set output 5 to event type 56-follow pin Menu 411 Set output 5 to 10 in event assignment-( 10 =this user ) Menu 412 Set output 5 to 4 = ( normally open one shot low ) Menu 413 Set output 5 to 000 000 005 000 ( 5 seconds ) Menu 414 Enable output 5 to display status message Menu 415 To open door press 5 and ok. Setting up an Request to exit zone. Select zone and set to Display only ( 14 ) Menu 311 Select an area for the zone Menu 312 Select the door that the zone belongs to. Menu 315

Communications setup Tx 1 used for the e.g. Contact ID Select Tx 1 and set to contact id (default is C.I.D) Menu 540 Enter account number per area Menu 220 Enter base station numbers Menu 511 Test report period Menu 592 Test report route Menu 594 Open/close route Menu 222 Report route(per zone) Menu 316 Status route (system events E.g. low battery, ac fail) Menu 543 Emergency route (keypad fire, panic, medical) Menu 544 Contact ID using GSM Select Tx 1 and set to GSM contact id (default is C.I.D) Menu 540 Enter Account number per area Menu 220 Enter base station numbers Menu 511 Test report period Menu 592 Test report route Menu 594 Open/close route Menu 222 Report route (per zone) Menu 316 Status route (system events E.g. low battery, ac fail) Menu 543 Emergency route (keypad fire, panic, medical) Menu 544

SMS Select Tx 1 and set to sms Menu 540 Enter mobile phone numbers in Menu 511 Test report period Menu 592 Test report route Menu 594 Open/close route Menu 222 Report route (per zone) Menu 316 Status route (system events E.g. low battery, ac fail) Menu 543 Emergency route (keypad fire, panic, medical) Menu 544 SMS using GSM Select Tx1 and set to GSM SMS (12) Menu 540 Enter mobile numbers in Menu 511 To use SMS commands to control the system enter the mobile number/s that you will be sending the command from. Menu 656 Test report period Menu 592 Test report route Menu 594 Open/close route Menu 222 Report route per zone Menu 316 Status route (system events E.g. low battery, ac fail) Menu 543 Emergency route (keypad fire, panic,medical) Menu 544 Domestic dial Default panel to domestic dial (only effects comms programming) Menu 703 Enter phone numbers in Menu 511

Commonly used locations Home area Menu 613 Home area only Menu 612 Add token Menu 120 Add key fob Menu 130 Display area icons Menu 615 Enable Bosch R.F receiver (option 4) Menu 350 Turn off part arm via key fob Menu 622 Turn off audible key fob panic Menu 622 Zone array Menu 301 Operate output manually Menu 401 Output array Menu 402 Panel tamper options Menu 360 Lan scan Menu 602 E.O.L value Menu 340 Disable dialler Menu 521 Service interval Menu 292 Monitor default pin Menu 770 First to open/last to close Menu 771 Rf beep volume Menu 742 Test report time Menu 591 Test report period Menu 592 Test route Menu 594 Time/date Menu 710 Speaker beeps via key fob Menu 213 Strobe flash via key fob Menu 215 Set chime zones Menu 303 Chime mode Menu 206 Chime mode on ( Press and hold the 4 key) to toggle or use Menu 205 Zone silent alarm Menu 318 Invert zone seal Menu 318

Zone test on exit Menu 318 Service mode Menu 708 Start direct link Menu 505 Dial number test Menu 595 History log Menu 702 System trouble Menu 701 Open close after alarm Menu 214 Cancel reports Menu 214 Battery test Menu 791 Open/close reports (per user) Menu 142

System Components Keypads CP050B night arm station CP150B External vandal resistant keypad (large) CP151B External vandal resistant keypad (slim) CP700B Graphic white (non prox) CP701B Graphic white with prox CP710B Graphic black (non prox) CP711B Graphic black with prox Readers PR109B Internal LAN prox reader (black) PR110B Internal LAN prox reader (white) PR111B External LAN prox reader (black) PR112B External LAN prox reader (white) PR116B External LAN Smart Card reader (white) PR115B External LAN Smart Card reader (black) PR114B Internal LAN Smart Card reader (white) PR113B Internal LAN Smart Card reader (black) CM728B Bio metric reader (black) CM729B Bio metric reader (white) Prox credentials PR200 ( Grey token ) PR201 ( Black token with keyring ) PR260 ( clam shell prox card ) PR250 ( ISO prox card ) Smart card credentials PR301 ( Smart card token with keyring ) PR350 ( ISO Smart card ) PR365 ( Adhesive smart card sticker )

System Components Expansion modules CM101B voice module CM195B Multi RF receiver interface CM704B 8/16 zone input expander CM705B universal expansion module CM707B piggy back zone input expander (used with CM705B) CM710B 4 way relay output module CM720B 1 amp power supply module CM743B GSM/GPRS 2G plug on module CM751B TCP/IP interface module CM760B Real time clock module CM797B LAN isolator module Accessories SW500B Solution link software SW501B Site manager software ( customer software ) CM900 Direct link cable CM901 Firmware upgrade cable CM255 Default key module (one time use only) CM940B 6 way programmable relay card. (Can be separated into single cards )